GLORIA ELENA is a 1981 freight ship. The Coast Guard has recorded 19 inspections since 2016, most recently in May 2023, along with 29 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 18 May 2023.

Built
1981
Last inspected
18 May 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 May 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8012566
226879
Flag
MEXICO
Maury page id
psix-226879

Documentation record

Tonnage as PSIX records it18642 - Displacement, Ton
9306 - Convention (Subpart B), Gross Ton
3254 - Convention (Subpart B), Net Ton
13850 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

18 May 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7687875
1 May 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7678784
20 April 2023 PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7669126
27 March 2023 PSC A · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7654206
10 June 2020 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6972785
30 May 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6972279
10 April 2020 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6937867
17 March 2020 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6927853
15 March 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6926800
24 February 2020 Deficiency Check · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6914348
3 February 2020 ISPS Exam · Deficiency Check · ISM Exam · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6901496
11 February 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6620924
16 January 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6609155
30 December 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6604081
22 June 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6452128
21 June 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6452343
16 November 2017 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6307854
20 October 2017 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6291583
16 August 2016 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5974026

Deficiency record · 29

14 - Pollution Prevention › N/A - No Subsystem › VGP: Annual Report
Issued 20 April 2023 Resolved
FOR EACH VESSEL, OWNERS/OPERATORS ARE REQUIRED TO SUBMIT AN ANNUAL REPORT FOR EACH YEAR THEY HAVE ACTIVE PERMIT COVERAGE. VGP 4.4.1 PSCO OBSERVED A NOTICE OF INTENT FROM 2016 BUT NO ANNUAL REPORTS HAVE BEEN SUBMITTED.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 18 May 2023
Resolution: Vessel Resubmitted EPA reports for years dating back to 2017 to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 27 March 2023 Resolved
11134 - Life Saving Appliances - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed 03 ring lifebuoy lights were inop. PSCO expanded inspection of ring lifebuoy lights and discovered the lights had incorrect batteries installed. - 74 SOLAS (20) III/20.2 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2023
Resolution: Vessel submitted class report attesting that all life buoy batters were replaced, and are operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 March 2023 Resolved
07120 - Fire Safety - Such doors shall be arranged so that positive closure is assured by self-closing. PSCO observed self-closing door for emergency escape truck in the engine room would not properly close and latch, allowing for the passage of smoke and flame. - 74 SOLAS II/34(b)(iii) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2023
Resolution: Self-closing mechanism was adjusted and the emergency escape door was found to be operational, and was verified by class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 March 2023 Resolved
03199 - Water/Weathertight Conditions - The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light ground. PSCO observed portside deckline was not painted contrast in color. - ICLL 1966 Annex I/8 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 April 2023
Resolution: Vessel submitted class report attesting to the deck line being repainted black and both port and starboard deck lines and freeboard assignments are in contrast.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 March 2020 Resolved
The condition of the ship and it's equipment be maintained to conform with the provisions of the present regulations to ensure the ship in all respect will remain fit to proceed to sea without danger to the ship and persons on board. Fire doors in engine room are missing latch locking mechanisms. Ship is awaiting parts. Fire doors include; fire door going down the stairs to engine control room. Fire door to shop across from ECR, emergency escape door from ECR and fire door between ECR and engine room. Invoice # 58429, estimated arrival- week 14 of 2020. 74 SOLAS (14) I/II 40bc
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 April 2020
Resolved 10 April 2020
Resolution: Latch locking mechanisms installed. Operation of fire doors verified by flag representative.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 February 2020 Resolved
The periodical surverys reffered to in paragraphs (a)(iii) shall be endorsed on the cargo ship radio certifcate. Certficate was issued 07JUN2019 by Flag, already had surveyors signature on the blocks on back page not allowing blocks to be properly signed and dated when surveys take place.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2020
Resolution: New SOLAS safety radio certificate can be properly signed.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 24 February 2020 Resolved
An annual survey within three months before or after each anniversary date of the certicate including a general inspection of the structure, equipment sysemts, fitting arrangement and material. IOPP issued on 23JAN2020 by Flag, already had surveyors signature on the blocks on back page not allowing blocks to be properly signed and dated when surveys take place.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2020
Resolution: New IOPP can be properly signed and dated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 February 2020 Resolved
One approved cover of a highly visible color capable of protecting the occupants against injury by exposure. There were 2 covers of which were in poor condition for the lifeboats. The covers had gaping holes and duct tape that served as temporary repairs. 74SOLAS III/11.9.xxvi 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2020
Resolved 5 February 2020
Resolution: Vessel provided class report and photos of new lifeboat cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2020 Resolved
All exposed metal parts of electrical machines or equipment which are not intended to be “live” but are liable to become “live” under fault conditions... shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. One electrical outlet next to the Masters office desk was completely pulled off the wall with exposed wires. Cables that were previously used for water pumps on the lower level of the engine room were still present (2 pumps total) and could cause shock if “live” and touched inadvertently. Those cables are dead ended and wrapped in only electrical tape. The attached cable to one of these pumps is heavily worn such that the protective sheathing was broken. Other small junction boxes were loose allowing unprotected parts of cabling to be pulled out. 74SOLAS II-1/27(a)(I)(1) 16bc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 24 February 2020
Resolution: PSC conducted a Deficiency check and cleared the outstanding Defeiciency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 February 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Several fire doors around the ship were in disrepair. The latching bolts were broken, missing or sealed with epoxy when all 3 bolts in each door intended to be operational. The hardware on several doors were broken. Some doors were difficult to close when provided closing arrangements. One did not latch at all (engine control room door) and could be pushed open. The fire doors noted include: the fire door going down the stairs to the engine control room (ECR), the fire door to the shop at the bottom of the stairs, the emergency escape door from ECR, and the fire door between ECR and the engine room. 74 SOLAS(14) I/11 16bc
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 February 2020
Resolved 17 March 2020
Resolution: Extended and re issued form B for shipping time of parts.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 3 February 2020 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company (10.1). And meeting these requirements the company should ensure that (10.2); inspections are held at appropriate intervals (10.2.1); any non-conformity is reported with its possible cause if known (10.2.2); appropriate corrective action is taken (10.2.3); in records of these activities are maintained (10.2.3). The company should identify equipment and technical systems, the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. These measures should include the regular testing of standby arrangements and equipment or technical systems that are not in continuous use (10.3) According to ships procedures M1 - M13, the lifeboats and all associated equipment are visually inspected weekly (10.2.2). As required by ships procedures in accordance with requisition number 151/19, the crew submitted a request for new medication on 28 August 2019; however, the order has not been completed (10.2.3). The ships safety management systems do not include procedures for training on installing the lifeboats canopy. Additionally, procedures are not in place for regular inspections on class a fire doors found in the engine room (10.3) Deficiencies one, two, three, and observations above are objective evidence that the vessel failed to fully implement the requirements of the SMS. An internal audit is required within three months with a focus on crew inspection procedures of the safe life-saving and fire fighting and requisitions. 74 SOLAS 14 IX/ 3.1 ISM 10.1, 10,2, 10.3 705c (3 months)
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2020
Resolved 30 May 2020
Resolution: Received satisfactory internal audit for subject deficiency to clear the deficiency. The internal audit has been uploaded to the documents tab as "ISM Internal Audit - 30May2020."
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 11 February 2019 Resolved
04114 - In cargo ships 5000 tons gross tonnage and upwards, there shall be a self contained emergency source of power. PSCO observed crew unable to start emergency generator after multiple attemps. - 74 SOLAS II-1/26(a)(1) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2019
Resolution: Starter solenoid replaced. Class and USCG attended to test.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 February 2019 Resolved
15105 - A vessel equipped with ballast water tanks that operates in the waters of the U.S. must maintain a ballast water management plan that has been developed specificaly for the vessel and that will allow those responsible for the plans implementation to understand follow the vessel's ballast water management strategy and comply with the requirements of this subpart. Vessel's ballast water management plan does not include all of the necessary provisions listed in 33 CFR 151 Subpart D. 33 CFR 151.2050(g) 50c
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2020
Resolution: Vessel's company updated BWM Plan relating to how to handle ballast water in US waters. According to the vessel's new policy, vessel is not permitted to discharge ballas waster into US waters at all.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 February 2019 Resolved
15105 - The master, owner, operator, agent or PIC of a vessel must ensure the maintenance of records. PSCO observed that the ballast water management record book was missing signature attesting to the accuracy of the information provided. 33 CFR 151.2070(a)(2) 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2020
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 February 2019 Resolved
15105 - Vessels operating within 03 miles nautical miles of the U.S. must conduct routine visual inspections, once per week or voyage and document in official logbook. Inspections are not being conducted nor recorded as required under section 4.1.1.1 in 2013 VGP. 33 USC 1251 40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2020
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 22 June 2018 Resolved
0810-Every ship shall carry appropriate portable atmoshpere testing instrument and suitable means shall be provided for calibration of such instruments. PSCO observed portable gas meters on board were not calibrated for 272 days and no calibration equipment was onboard. 74SOLAS(14)XI-2/7. 40c
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2018
Resolution: Mexican Class Surveyor provided class report attesting that the vessel was provided with a new gas detector, calibration accessories and factory calibration certificate dated 20SEP18.
Electrical › Electric Generation Source (emergency) › Generator
Issued 22 June 2018 Resolved
1499-The Condition of the ship nad its equipment shall be maintained to conform with the provions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed flexible ducting missing between emergency generator cooling radiator and outside vent. 74SOLAS(14)I/II(a). 50a
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2018
Resolved 30 December 2018
Resolution: Class Surveyor onboard witnessed and provided class report identifying repairs made to the emergency generator by means of installing flexible ducting between radiator and vent.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 20 October 2017 Resolved
0160 - IAPP Certificate - Ships constructed before the date of entry into force of Annex VI for such ship's Administration shall be issued with an IAPP Ceritificate. - The ship does not have an IAPP Certificate - MARPOL VI / 6.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2017
Resolution: Recieved confirmation MEXICO is NOT signatory to ANNEX VI of MARPOL.
Documentation › Logs/Records › Oil Record Book
Issued 20 October 2017 Resolved
1710 - Oil Record Book - Each operation of this regualtion shall be full recorded with out delay in the ORB Part I, so that all entries in the book appropiate to that operation are completed. - ORB displays entries exceeding maximum input of OWS system according to IOPP Certificate. All entries observed far exceeded the input since 01JAN17. - MARPOL I / 17.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 November 2017
Documentation › Logs/Records › Oil Record Book
Issued 20 October 2017 Resolved
1710 - Oil Record Book - The company should ensure that all personnel involved in the company's safety management system have an adequate understanding of relevant rules, regulations, codes and guidelines. - Provided with the dificiencies listed on PSC Form B dated 20OCT17, the vessel is not following procedures concerning proper documentation in the Oil Record Book. An external audit concerning the protection of the enviroment is recommended. - SOLAS 74(2014CONS.)IX/3.1 - ISM Code 6.4
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 November 2017
Resolved 16 November 2017
Resolution: Verified external audit, crew training and knowledge of Oil Record Book. Proper modifications were found to be satifactory by Coast Guard personnel.
Documentation › Logs/Records › Oil Record Book
Issued 20 October 2017 Resolved
1710 - Oil Record Book - Each operation of this regulation shall be fully recorded without delay in the ORB Part I, so that all entries in the book appropiate to that operation are completed. Vessel is not correctly labeling discharges to shore reception facilities - MARPOL I / 17.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2017
Resolution: Deficiency rectified to the satisfaction of the U.S Coast Guard
Documentation › Logs/Records › Oil Record Book
Issued 20 October 2017 Resolved
1710 - Oil Record Book - Each completed operation shall be signed by the officer or offices in charge of the operations concerned and each completed page shall be signed by the master of the ship. Master signed incomplete ORB page - MARPOL I / 17.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2017
Resolution: Deficiency rectified to the satisfaction of the U.S. Coast Guard.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 29 November 2016 Resolved
0740-Pumps-Ships must have alternative means of providing water for fire fighting. The vessel's emergency fire pump is inoperable. - SOLAS 74 II-2 Reg 52(b)(ii)- 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 13 December 2016
Resolution: Vessel's fire pumps are fully operational
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 29 November 2016 Resolved
2050- Ships must be outfitted with a self-contained emergency source of power. The emergency generator onboard is inoperable. - SOLAS 74 II-1 Reg. 26 (a)(i) - 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 13 December 2016
Resolution: Vessel overhauled and installed new batteries in the EDG
Navigation › Piloting/Steering › Gyro Compass
Issued 29 November 2016 Resolved
1540 - All ships 500gt and upwards must have a gyro-compass to determine and display their heading. Proper heading between bridge and steering can not be confirmed. SOLAS 14 V reg. 19.2.5 - 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 13 December 2016
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 29 November 2016 Resolved
1581 - The exact position of the rudder if power operated, shall be indicated at the principal steering station. The vessel has different rudder indication at the bridge station and steering controls. - SOLAS 74 Ch. II-1 Reg. 29(a)(iv) - 17abc
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 13 December 2016
Resolution: ABS attested to repairs, full test was completed by PSCOs.
Operations/Management › Pollution › Approved Method for Annex VI Compliance
Issued 29 November 2016 Resolved
1999-MARPOL-Vessels operating in emissions control areas shall carry a written procedure showing how the fuel oil changeover is to be done. The vessel does not have changeover procedures onboard.- MARPOL Annex VI/reg. 14.6
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 13 December 2016
Resolution: Vessel provided proper documentation regarding changeover procedures.
Engineering › Steering Gear System › Rudder
Issued 29 November 2016 Resolved
0936-Safety in General- Indicators for running indication of the motors of electric and electrohydraulic steering gear shall be installed.The power failure alarm for the steering gear system does not work.-74 SOLAS CH.II-I/30
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 13 December 2016
Resolution: Alarms were tested for both steering gears, all sat.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 16 August 2016 Resolved
0820-Accident prevention-There shall be non-conducting mats or gratings front and rear where necessary. The vessel is missing non-conducting mats at several switchboards and control panels throughout the engine room.-74 SOLAS II-I/27(a)(ii)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 29 November 2016
Resolution: Non conducting mats were placed in all apropriate spots.