Records from 1984 to 2007. Most recent: inspection, 5 November 2007.
Inspection history · 55
5 November 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3093098
1 November 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3091289
14 February 2006
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2583101
13 February 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2582263
13 February 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2584660
8 February 2006
PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2581056
6 February 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2580420
2 February 2005
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 2285377
21 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2245495
17 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2243267
15 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2242526
18 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2307284
18 July 2004
Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2136973
14 July 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2133151
13 July 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2132270
12 July 2004
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2130006
5 July 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2122317
5 July 2004
STCW 95 Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2122453
30 June 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2116615
29 June 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2116089
28 June 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2113429
28 June 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2114644
28 June 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2120976
9 April 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1771184
17 January 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1479544
17 July 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 279855
31 January 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274121
30 July 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 431210
22 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421450
16 December 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410984
6 December 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 410756
20 April 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 402836
17 December 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 716478
6 December 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 177388
2 December 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 716850
13 December 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 373382
13 December 1994
Uninspected Other
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 839042
4 September 1994
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 370182
5 November 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 362287
16 October 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 361739
15 October 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 646036
20 August 1992
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 352692
25 April 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 350276
8 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 343653
20 March 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 335963
7 November 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 495149
13 March 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 329017
1 June 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 491791
5 January 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 320556
10 April 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 497394
22 November 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 505839
27 May 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 437330
6 August 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 303587
1 August 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 303416
29 May 1984
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 532738
Construction/Loadline › Hull › Collision Chock
Issued 14 February 2006
Resolved
Damage to starboard deck above No. 5 topside ballast tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2006
Resolution: Refer to NKK class report, which are scanned into the Documents Tab.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 8 February 2006
Resolved
The No. 1 and No. 2 Generators have fuel oil leaks at the duplex strainers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 15 February 2006
Resolution: Received class report stating fuel leaks have been repaired.
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 8 February 2006
Resolved
The No. 1 Generator has a water leak at the fresh water pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 15 February 2006
Resolution: Received class report stating fresh water pump casing has been replaced.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 July 2004
Resolved
Doors in stairwell are self-closing and being held open. Class to address issue and verify proper operation.
Due 12 August 2004
Resolved 18 July 2004
Resolution: All stairwell doors are free and operate properly.
Fire Fighting › Fire Main › Condition
Issued 28 June 2004
Resolved
Firemain stbd-side fwd of #2 cargo hold is holed and unable to maintain sufficient pressure. Cite:SOLAS 74 (unamend) Ch.II-2/Reg.5(c). Repair prior to departure to the satisfaction of the attending class surveyor..
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 30 June 2004
Resolution: Rcvd class rpt attesting to the repairs. Def. cleared.
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 28 June 2004
Resolved
(01) drain plug missing per lifeboat, (02) buckets missing from port lifeboat, (01) boathook missing from stbd lifeboat, (01) whistle missing from stbd lifeboat, & no illumination for each lifeboat magnetic compasses. Cite: SOLAS 74 (unamend) Ch.III/Reg.II (a) & (c). To be corrected prior to departure by providing reciept of purchases..
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2004
Resolved 30 June 2004
Resolution: MSO PHILADELPHIA PERSONNEL WITNESSED REQUIRED ITEMS WITHIN LIFEBOATS. DEF. CLEARED.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 28 June 2004
Resolved
Vessels charts and light list were found not to be corrected up to date, need notice to mariners week 17 thru present. Cite: 33 CFR 164.33 (a) (1) (ii) &( 2) (ii). To be corrected prior to departure by providing receipt of purchase.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2004
Resolved 30 June 2004
Resolution: MSO PHILADELPHIA PERSONNEL WITNESSED REQUIRED NTM''S O/B THE VSL. DEF. CLEARED.
Navigation › Piloting/Steering › Magnetic Compass
Issued 28 June 2004
Resolved
Vessel's magnetic compass was found to be substantially discrepant with that of the gyro compass, thus requiring recalibration of said compass; i.e. Gyro: 094 degrees vs. Mag: 064 degrees. Cite: SOLAS 74 (unammend) Ch.5/Reg.12 (c) & 33 CFR 164.35 (b) & (c). To receive tech. report prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2004
Resolved 30 June 2004
Resolution: MSO PHILADELPHIA RECIEVED TECH REPORT FOR GRYO COMPASS.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 28 June 2004
Resolved
No record in garbage logbook or disposal receipts found for disposal of plastics since 06 MAR 2004. Cite: MARPOL 73/78 , Annex 5/Reg.9 & 33CFR 151.55. To be reviewed by local U.S. Coast Guard after 90 days to ensure compliance with said requirement.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 8 February 2006
Resolution: CG Marine Inspector examined garbage log book and disposal reciepts. All items examined found satisfactory.
Operations/Management › Drills/Instruction › Fire
Issued 28 June 2004
Resolved
Crew unable to perform satisfactory fire drill. Cite: SOLAS 74 (unamend) Ch.II-2/Reg.85. Crew to perform satisfactory fire drill to the sartisfaction of attending Coast Guard boarding members prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2004
Resolution: MSO PHILADELPHIA PERSONNEL WITNESSED SATISFACTORY FIRE DRILL. DEF. CLEARED.
Fire Fighting › Firemans Outfit
Issued 17 January 2002
Resolved
While conducting a fire drill, crew members arrived on scene with empty air bottles on their SCBA's. Master and crew were coached on how to properly conduct fire drills and the importance of material readiness was firmly stressed. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Condition: Placed in Improper Service
Due 23 January 2002
Resolved 23 January 2002
Resolution: Conducted a followup fire drill on the vessel. Fire drill was performed to the satisfaction of the inspectors.
Navigation › Piloting/Steering
Issued 17 January 2002
Resolved
Vessel was given a deviation to enter for an inoperable gyro compass on 17Jan02. During the examinationit was noted that the gyro compass was in very poor condition due to lack of maintenance. PORMS required master to submit a nonconformity report to the company, and to recieve feedback LEGACY COMPONENT DESC: Gyro Compass
Condition: Improper/Lack of Maintenance
Due 24 January 2002
Resolved 24 January 2002
Resolution: Recieved technicians report stating that the gyro compass has been repaired. Allowed vessel to depart.
Fire Fighting
Issued 17 July 2000
Resolved
Prove proper operation of the emergency fire pump. SOLAS 74 II-2/52. Correct prior to departure.
Condition: Unknown
Due 22 July 2000
Resolved 22 July 2000
Fire Fighting
Issued 17 July 2000
Resolved
Update fire plan and separate location of fire man's outfits. SOLAS 74 II-2/52. Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 22 July 2000
Resolved 22 July 2000
Fire Fighting
Issued 17 July 2000
Resolved
Install fixed gas extinguishing system for cargo holds or remove combustible cargo. SOLAS 74 II-2/52. Install prior to departure.
Condition: Unknown
Due 22 July 2000
Resolved 22 July 2000
Fire Fighting
Issued 6 December 1997
Resolved
PROPERLY CONDUCT PERMANENT REPAIRS TO FIRE MAIN PIPING,_x001C_ BETWEEN #2 AND #3 CARGO HOLDS ON STARBOARD SIDE MAIN DECK. _x001C_ TEMPORARY REPAIRS WERE MADE PRIOR TO DEPARTURE.
Condition: Unknown
Due 16 December 1997
Resolved 16 December 1997
Lifesaving
Issued 6 December 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Navigation
Issued 20 March 1990
Resolved
VESSELS NOS CHARTS 18720, 18740, 18746, 18749, 18751 WERE NOT CORRECTED TO TO DATE AS REQUIRED BY 33CFR164.33(A)(1)(II). U.S. COAST PILOT VOL 7 AND CG LIGHT LIST VOL IV ALSO NCTD. AS REQUIRED BY 33CFR164.33(A)(2)(II).
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Documentation
Issued 20 March 1990
Resolved
SOLAS SAFETY EQUIPMENT AND RADIOTELEGRAPHY CERTIFICATES EXPIRED.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Navigation
Issued 13 March 1989
Resolved
CHART 18746 NOT CORRECTED TO DATE. CORRECTIONS REQUIRED BY 33CFR164.33(A)(1).
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989