Records from 1984 to 2007. Most recent: operational control imposed, 22 January 2007.
Inspection history · 56
22 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2859610
22 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2861612
12 September 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2776183
2 November 2004
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2232703
15 January 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1985369
5 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1981303
28 October 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1937785
3 October 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1928762
2 October 2003
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1919382
12 May 2003
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1792073
11 May 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1791137
9 May 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2004099
6 December 2002
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1713287
30 July 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 292228
27 January 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 520863
25 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286720
29 June 2000
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051641
11 July 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 430419
10 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 416864
10 June 1998
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1431971
11 July 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 405159
1 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72080
31 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 402160
21 July 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 393590
20 July 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 380637
23 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 525731
11 October 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 864465
2 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 80127
2 August 1994
Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1174687
7 November 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 472753
17 September 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 360913
28 July 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1155851
6 May 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1136221
21 October 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 436380
12 May 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 958225
19 December 1991
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 952528
11 February 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1225001
13 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925514
17 January 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 923591
11 September 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 469989
27 February 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1194395
14 January 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 327930
14 January 1989
Certificate of Compliance
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1210602
26 July 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 324536
4 January 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 320328
4 January 1988
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1315175
31 May 1987
MARPOL Annex II Examination
Physical examination · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335562
9 January 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 313727
9 January 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1005446
7 July 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 310066
18 May 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 512411
31 December 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 306239
31 December 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 995104
6 September 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 304147
23 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 441032
25 April 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 296266
Lifesaving › Lifejacket/PFD (General)
Issued 2 October 2003
Resolved
Fwd lifejacket sotwage box is missing 4 jackets and shall be resupplied IAW safety equipment cert to class satisfaction prior to departing the port of NY. LEGACY COMPONENT DESC: Quantity
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 28 October 2003
Resolution: GL Calss report states that this issue has been resolved to their satisfaction, details not provided.
Fire Fighting › Fixed Deck Foam System
Issued 2 October 2003
Resolved
Instructions for fixed foam system missing and key crewmembers ([name withheld]) not familiar with the system operation. Demonstrate to sufficient knowledge of this system and correct documentation to satisfaction of GL. LEGACY COMPONENT DESC: Main Control Station
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 2 October 2003
Pollution Prevention/Response › Prevention Equipment
Issued 2 October 2003
Resolved
ODME Sampling pump found OOC and class not aware. GL has imposed a condition of class on this system for correction no later than 12/7/03. LEGACY COMPONENT DESC: Oily Mixture Discharge Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2003
Resolved 15 January 2004
Resolution: Received class report from GL satisfying requirement.
Deck/Cargo › Holds/Tanks
Issued 2 October 2003
Resolved
Crew unfamiliar and unable to properly prove proper operations of this system, nor able to calibrate this system. GL has imposed a condition of class on this system for correction no later than 12/7/03. LEGACY COMPONENT DESC: Fixed Gas Detection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2003
Resolved 15 January 2004
Resolution: Received class report from GL satisfying requirement.
Operations/Management › Navigation Safety
Issued 2 October 2003
Resolved
Aft towing arrangement lighted marker bouy light is non functional and corroded beyond repair. GL has imposed a condition of class on this system for correction no later than 12/7/03. LEGACY COMPONENT DESC: Towing Maintenance/Failure/Reporting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2003
Resolved 15 January 2004
Lifesaving › Launching Appliances
Issued 2 October 2003
Resolved
Stbd side lifeboat davits limit switches are not working and shall be repaired to satisfation of GL prior to departing the port of NY. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 3 October 2003
Electrical › Electric Generation Source (emergency)
Issued 2 October 2003
Resolved
Key crew members (Chief Engineer [name withheld] and all other lesser engineers) found unfamiliar with starting the emergency generator via emergency means. Instructions also missing and not posted as required.GL has imposed a condition of class on this system for correction no later than 12/7/03. LEGACY COMPONENT DESC: Power Requirement
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 December 2003
Resolved 15 January 2004
Resolution: Received class report from GL satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 2 October 2003
Resolved
Bilge water seperator found unable to automatically trip as required by MARPOL I at 15PPM. Instead it was tripping at 34 PPM and this also claimed by ChEng as "The way it worked". GL has imposed a condition of class on this system for correction prior to 12/7/03. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2003
Resolved 15 January 2004
Resolution: Received class report from GL satisfying requirement.
Electrical › Lighting (service)
Issued 2 October 2003
Resolved
Numerous lights thruout the engine spaces, the excape trunks, the rotating warning beacon lamps for fire and engine alarm systems, and thruout the vessel as a whole found in disrepair and lack of maintenance. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 29 October 2003
Resolution: GL class report received this date claims this condition has been rectifiied.
Operations/Management › Vessel Safety Management
Issued 2 October 2003
Resolved
Vessel shal submit to a full and impartial external audit of its SMS prior to departing the port of NY and submit the results of this audit to COTP NY prior to departing the port of NY. LEGACY COMPONENT DESC: External Certification/Verification/Control
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 29 October 2003
Resolution: GL class report received this date claims this had been accompished on October 6, 2003.
Electrical › Electrical Distribution System (service)
Issued 12 May 2003
Resolved
Junction boxes on main deck show wastage at electrical cable conduit connection. Repair to the satisfaction of class. SOLAS 74/78 II-1/45. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 January 2004
Resolution: Cleared with class report on 02 Oct 03 by NYCMI.
Fire Fighting › Structural Fire Protection - General
Issued 12 May 2003
Resolved
Most stairway doors do not close/latch. SOLAS 74/78 II-2/46 & 47. Correct to the satisfaction of class. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 January 2004
Resolution: Cleared with class report on 02 Oct 03 by NYCMI.
Deck/Cargo › Inert Gas System
Issued 6 December 2002
Resolved
Cargo tanks 5-6-9 over 8% oxygen (SOLAS 74/78 amended Ch. II-2 Reg 62) Prior to cargo ops, maintain oxygen level below 8% and properly operating IGS alarms and shutdowns to satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2002
Resolution: Oxygen levels below 8% on all cargo tanks. All IGS alarms and shutdowns operating properly.
Deck/Cargo
Issued 6 December 2002
Resolved
Excessive flammable materials, oil, rags, wood in Cargo Pump room (SOLAS 74 Ch. II-2/2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2002
Resolution: Materials removed from cargo pump room.
Engineering
Issued 6 December 2002
Resolved
Fuel/oil leaks in engine room, with plastic drip buckets. SOLAS 74 Ch. II-2/2. Repair permanently to sat. of class.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Deck/Cargo › Cargo Heating
Issued 6 December 2002
Resolved
Steam leaks on deck (3 different areas) SOLAS 74 ammended Ch. I Reg 11. Repair permanently to sat. of class by compliance date**.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Deck/Cargo
Issued 6 December 2002
Resolved
Excessive hydraulic leaks in Cargo Pump Room on control lines for remote valves.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Deck/Cargo › Inert Gas System
Issued 6 December 2002
Resolved
Control air leak on IGS main deck remote valve. SOLAS 74 ammended Ch II-2 Reg 62. Repair permanently.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Engineering
Issued 6 December 2002
Resolved
Steam leaks in Engine Room on boiler superheater valve and IGS fan steam turbine. SOLAS 74 amended Ch. I Reg 11 Ch. II-2 Reg 62. Repair permanently.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Engineering › Compressed Air System (control)
Issued 6 December 2002
Resolved
Portable duct for cooling of air compressors in Engine Room. (SOLAS 74 Ch I Reg 11). Class to verify operation of compressor cooling. LEGACY COMPONENT DESC: Compressor
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Engineering
Issued 6 December 2002
Resolved
Portable fan used for cooling engine automation system in main engine room control. (SOLAS 74 Ch II-1 Reg 26 ) Class to verify proper operation and cooling of engine automation system.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Deck/Cargo › Holds/Tanks
Issued 6 December 2002
Resolved
#1 Cargo tank over fill alarm inoperable. (33 CFR 155.480) Prior to loading liquid cargo in US make repairs to satisfaction of USCG Marine Inspector. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Action required: 705 - Other - as specified
Resolved 6 December 2002
Lifesaving
Issued 30 July 2001
Resolved
Sprinkler on (outboard side) of port side lifeboat is missing a 6ft sectionof their piping._x001C_ SOLAS 74 Chp. III Reg.46_x001C_ _x001C_
Condition: Unknown
Due 9 August 2001
Resolved 6 December 2002
Resolution: Sprinkler piping on port side lifeboat in place.
Fire Fighting
Issued 11 July 1997
Resolved
SOLAS 74 REG II/51._x001C_ STAIRWELL FIRE DOORS NOT PROPERLY CLOSING._x001C_ ADJUST ALL DOORS TO PROPERLY CLOSE NLT 11AUG97.
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Deck/Cargo
Issued 11 July 1997
Resolved
33 CFR 157.400._x001C_ NO EMERGENCY LIGHTERING EQUIPMENT O/B._x001C_ HAVE ALL REQUIRED EQUIPMENT O/B NLT 11AUG97.
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Navigation
Issued 11 July 1997
Resolved
33 CFR 157.440._x001C_ NO AUTOPILOT ALARM INSTALLED._x001C_ INSTALL ALARM BY 27NOV97.
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Fire Fighting
Issued 6 May 1993
Resolved
PROVIDE CLASSIFICATION SOCIETY REPORT ATTESTING TO THE SATISFACTORY OPERATION OF THE VESSEL'S EMERGENCY FIRE PUMP AND SATISFACTORY SYSTEM WATEROUTPUT AND PRESSURE.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Deck/Cargo
Issued 6 May 1993
Resolved
PRIOR TO NEXT U.S. PORT HYDROSTATICALLY TEST VESSEL'S CARGO PIPING TO 1 1/2MAWP.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Navigation
Issued 12 May 1992
Resolved
Demonstrate proper operation of the ARPA prior to departure from the Port of Houston.
Condition: Unknown
Due 18 May 1992
Resolved 18 May 1992
Navigation
Issued 12 May 1992
Resolved
Demonstrate proper operation of the rudder angle indicator prior to departure from the Port of Houston.
Condition: Unknown
Due 18 May 1992
Resolved 18 May 1992
Fire Fighting
Issued 17 January 1990
Resolved
PROVIDE FIXED CO2 SYSTEM FOR PLANT LOCKER OR REMOVE LOCKER.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Deck/Cargo
Issued 17 January 1990
Resolved
CARGO MONITOR DISCHARGE SYSTEM NOT WORKING PROPERLY. MAKE PROPER REPAIRS.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Deck/Cargo
Issued 17 January 1990
Resolved
IG SYSYTEM TIED INTO CARGO PUMP BOILER. SYSTEM SHOULD BE CHECKED BY CLASSIFICATION SOCIETY FOR PROPER OPERATION.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Navigation
Issued 14 January 1989
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MOST CURRENT ED OF U.S. TIDAL CURRENT TABLES, OR ITS FOREIGN EQUIV, AS REQUIRED BY 33 CFR 164.33(A)(3)(II) WAS NOT O/B. THE VSL HAD O/B U.S. TIDAL CURRENT TABLES DTD 1988. THE MOST CURRENT ED OF U.S. TIDAL CURRENT TABLES IS DTD 1989.
Condition: Unknown
Due 14 January 1989
Resolved 14 January 1989
Navigation
Issued 25 April 1984
Resolved
A CURRENTLY CORRECTED COPY OF THE U.S. COAST PILOT, VOL 3 OR ITS EQUVILANT AS REQUIRED BY 33 CFR 164.33 (A)(2)(I), WAS NOT ON BOARD. THE VESSEL HAD ON BOARD COAST PILOT PUBLISHED BY GERMANY DATED 1982 WITH NO CORRECTIONS.
Condition: Unknown
Due 25 April 1984
Resolved 25 April 1984
Unknown
Issued 25 April 1984
Resolved
THE OIL TRANSFER PROCEDURES REQUIRED BY 33 CFR 155.720 DID NOT MEET THE REQUIREMENTS OF 33 CFR 155.750, IN THAT THEY DID NOT CONTAIN: DUTIES BY TITLE, TOPPING OFF INST., VALVE INST., PROCEDURES FOR EMPTYING CONTAINMENT.
Condition: Unknown
Due 25 April 1984
Resolved 25 April 1984
Unknown
Issued 25 April 1984
Resolved
THE POLLUTION PROHIBITION PLACARD IN THE MACHINERY SPACES, REQUIRED BY 33 CFR 155.450 WAS NOT POSTED.
Condition: Unknown
Due 25 April 1984
Resolved 25 April 1984
Navigation
Issued 25 April 1984
Resolved
THE MOST RECENT, AVAILABLE AND CURRENTLY CORRECTED COPY OF THE TIDAL CURRENT TABLES OR ITS EQUIVALENT, AS REQUIRED BY 33 CFR 164.33(A)(3)(II) WAS NOT ON BOARD.
Condition: Unknown
Due 25 April 1984
Resolved 25 April 1984