Records from 1985 to 2001. Most recent: inspection, 10 May 2001.
Inspection history · 32
10 May 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 289989
27 July 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 727445
21 May 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 277903
10 April 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 91872
15 June 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 416900
17 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 409083
7 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 406620
14 May 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 514585
7 May 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 403398
2 April 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 707274
14 March 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 401919
10 March 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 529179
26 February 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 400983
19 November 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 60792
17 November 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 73324
21 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 182344
22 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 469620
16 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394429
23 April 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 390402
17 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 390475
26 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383350
9 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 707275
8 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 381498
8 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 500387
27 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 374764
5 December 1994
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 511246
3 December 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1181709
3 November 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 707276
24 October 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 371644
24 October 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1459905
16 December 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 482469
9 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 301868
Navigation
Issued 10 May 2001
Resolved
MISSING CHART NUMBER 25670. MUST PROVIDE PRIOR TO DEPARTURE.(33CFR 164.33)NOT CORRECTED RECEIPT PROVIDED WAS FOR CHART 25640.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Fire Fighting
Issued 10 May 2001
Resolved
PAINt LOCKER SPRINKLER VALVE PLACARD NOT STENCELED.(SOLAS 74 II/2/20.1) _x001C_ PROVIDE CLASS REPORT TO U.S.C.G.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Lifesaving
Issued 10 May 2001
Resolved
LIGHT ON ONE RING LIFE BOUY INOPRATIVE. REPLACE LIGHT PRIOR TO DEPARTURE _x001C_(solas 74 AMENDED III/19.2)
Condition: Unknown
Due 10 May 2001
Resolved 15 May 2001
Electrical
Issued 10 May 2001
Resolved
RENEW THE ONE (1) EMERGENCY LIGHTING BATTERY THAT IS CRACKED.(SOLAS 74 AMENDED II-1/43) _x001C_ PROVIDE CLASS REPORT TO U.S.C.G.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Navigation
Issued 15 June 1998
Resolved
REPAIR RUDDER ANGLE INDICATOR LOCATED ON STEERING FLAT TO INDICATE PROPER ANGLE OF DEGREE AND DIRECTION OF RUDDER.
Condition: Unknown
Due 22 June 1998
Resolved 23 June 1998
Engineering
Issued 15 June 1998
Resolved
REPAIR EXHAUST LEAK LOCATED IN FORWARD EMERGENCY PUMP COMPARTMENT ON EXHAUST MANIFOLD.
Condition: Unknown
Due 22 June 1998
Resolved 23 June 1998
Fire Fighting
Issued 26 February 1997
Resolved
MISSING SPANNER WRENCHES IN FIRE BOXES THROUGHOUT MAIN DECK. SOLAS 60
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Electrical
Issued 26 February 1997
Resolved
EMERGENCY GENERATOR HAS AN EXHAUST LEAK. SOLAS 60
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Fire Fighting
Issued 26 February 1997
Resolved
NO INTERNATIONAL SHORE CONNECTION. SOLAS 60
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Engineering
Issued 26 February 1997
Resolved
OWS COULD NOT BE TESTED DUE TO OIL ON THE LINES. MARPOL 73/78
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Fire Fighting
Issued 17 April 1996
Resolved
Repair inoperative emergency fire pump prior to departing port. Solas 74/78 II 2/4.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Navigation
Issued 8 August 1995
Resolved
VSL DID NOT HAVE A MEANS OF DETERMINING THE RUDDER ANGLE FROM THE EMERGENCYSTEERING STATION.
Condition: Unknown
Due 30 September 1995
Resolved 30 September 1995
Accommodation/Occupational Safety
Issued 8 August 1995
Resolved
VSL HAD INSTALLED SEWAGE TANK WITH PIPE ACCESS DIRECTLY OVERBOARD. THE_x001C_ VALVE WAS IN THE OPEN POSITION ALLOWING THE VESSELS SYSTEM TO DISCHARGE_x001C_ DIRECTLY OVERBOARD AS IT TRANSITED INLAND WATERS OF THE UNITED STATES.
Condition: Unknown
Due 8 August 1995
Resolved 9 August 1995
Navigation
Issued 27 January 1995
Resolved
COMMUNICATION FROM ENGINE ROOM AND AFT STEERING TO BRIDGE INOPERABLE._x001C_
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 24 October 1994
Resolved
CHART NUMBER 11376, EDITION 43 OF OCTOBER 23, 1993, WAS NOT UPDATED AND CORRECTED ACCORDING TO NOTICE TO MARINERS, EDITION 38, UPDATE 3223._x001C_ 46 CFR 97.05-59(a)
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Navigation
Issued 24 October 1994
Resolved
THE VESSEL DID NOT HAVE A COPY OF THE U.S. COAST PILOT._x001C_ 46 CFR 97.05-5(c)
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Navigation
Issued 24 October 1994
Resolved
THE VESSEL DID NOT HAVE A COPY OF THE U.S.C.G LIGHT LIST OR ITS FOREIGN EQUIVALENT._x001C_ 46 CFR 97.05-5(d)
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Navigation
Issued 24 October 1994
Resolved
THE VESSEL DID NOT HAVE A COPY OF TIDE TABLES._x001C_ 46 CFR 97.05-5(f)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Navigation
Issued 24 October 1994
Resolved
THE VESSEL DID NOT HAVE A COPY OF TIDAL CURRENT TABLES._x001C_ 46 CFR 97.05-5(g)
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Navigation
Issued 24 October 1994
Resolved
THE VESSEL'S MARINE RADAR WAS INOPERABLE._x001C_
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Navigation
Issued 24 October 1994
Resolved
THE VESSEL DID NOT HAVE A COPY OF INLAND NAVIGATION RULES.
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Engineering
Issued 24 October 1994
Resolved
REPAIR DETERIORATED/LEAKING SALT WATER PIPING FROM MAIN DIESEL ENGINE RAW WATER COOLING PUMP PRIOR TO ENTRY TO NEXT U.S. PORT. ITEM SHALL BE CORRECTED TO THE SATISFACTION OF FLAG ADMINISTRATION CLASS SOCIETY AND COGNIZANT U.S. COAST GUARD OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 24 October 1994
Resolved
RENEW DETERIORATED 30X30 WIRE MESH FLAME SCREEN TO FUEL OIL TANK VENTS LOCATED ON PORT SIDE UPPER DECK. ITEM SHALL BE CORRECTED PRIOR TO ENTRY TO NEXT U.S. PORT TO THE SATISFACTION OF THE COGNIZANT U.S. COAST GUARD OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 24 October 1994
Resolved
REPAIR AND PROVE OPERATION OF INDICATING/OPERATING LIGHTS FOR OILY WATER SEPERATOR AND 15 PPM ALARM.
Condition: Unknown
Due 25 October 1994
Resolved 8 November 1994
Lifesaving
Issued 24 October 1994
Resolved
SERVICE AND INSTALL INFLATABLE LIFE RAFTS TO EACH SIDE OF VESSEL PRIOR TO DEPARTURE FROM THE PORT OF THEODORE, ALABAMA
Condition: Unknown
Due 25 October 1994
Resolved 8 November 1994
Fire Fighting
Issued 24 October 1994
Resolved
REPAIR OR RENEW DEFECTIVE FIRE DAMPER LOCATED IN AFT BRIDGE DECK PORT SIDE VENTILATOR. ITEM SHALL BE COMPLETED TO THE SATISFACTION OF THE FLAG ADMINISTRATION CLASS SOCIETY AND COGNIZANT U.S. COAST GUARD OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 24 October 1994
Resolved
LOCATE, ISOLATE, AND REPAIR ELECTRICAL EARTH GROUND DETECTED ON ELECTRICAL SWITCHBOARD FOR ELECTRICAL DISTRIBUTION LIGHTING CIRCUITS. ITEM SHALL BE CORRECTED TO THE SATISFACTION OF THE FLAG ADMINISTRATION CLASS SOCIETY PRIOR TO ENTRY OF NEXT U.S. PORT.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Lifesaving
Issued 24 October 1994
Resolved
PROVIDE EIGHT LIFE RING BUOYS IN ACCORDANCE WITH FLAG ADMINISTRATION ISSUEDCARGO SHIP SAFETY EQUIPMENT CERTIFICATE.
Condition: Unknown
Due 25 October 1994
Resolved 8 November 1994
Lifesaving
Issued 24 October 1994
Resolved
PROVIDE ONE ADDITIONAL WATERLIGHT FOR RING LIFE BUOY IN ACCORDANCE WITH FLAG ADMINISTRATION ISSUED CARGO SHIP SAFETY EQUIPMENT CERTIFICATE.
Condition: Unknown
Due 25 October 1994
Resolved 8 November 1994
Fire Fighting
Issued 24 October 1994
Resolved
DEMONSTRATE THAT VESSELS FIRE PUMP CAN PRODUCE ADEQUATE FIREMAIN PRESSURE AT EACH FIRE HYDRANT.
Condition: Unknown
Due 25 October 1994
Resolved 8 November 1994
Construction/Loadline
Issued 24 October 1994
Resolved
RENEW SECURING DEVICES TO GOOSENECK VENTS LOCATED ON FORECASTLE DECK AND AFT BRIDGE DECK. ITEMS SHALL BE COMPLETED PRIOR TO ENTRY OF NEXT U.S. PORT TO THE SATISFACTION OF FLAG ADMINISTRATION CLASS SOCIETY AND COGNIZANT U.S.COAST GUARD OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Fire Fighting
Issued 24 October 1994
Resolved
REPAIR AND PROVE OPERATION OF EMERGENCY FIRE PUMP PRIOR TO DEPARTURE OF THEPORT OF THEODORE, ALABAMA.
Condition: Unknown
Due 26 October 1994
Resolved 8 November 1994
Navigation
Issued 24 October 1994
Resolved
RENEW DEFECTIVE BATTERY TO ONE GMDSS EMERGENCY VHF RADIO LOCATED ON BRIDGE.ITEM SHALL BE COMPLETED PRIOR TO ENTRY TO NEXT U.S. PORT TO THE SATISFACTION OF FLAG ADMINISTRATION CLASS SOCIETY AND THE COGNIZANT U.S. COAST GUARD OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Deck/Cargo
Issued 9 May 1985
Resolved
SHIPPING OF CLASS "A" EXPLOSIVES IN CONTAINERS THAT HAVE EXPIRED OR NO CSC APPROVAL CERTIFICATE
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Deck/Cargo
Issued 9 May 1985
Resolved
SHIPPING CLASS B AND C EXPLOSIVES IN CONTAINERS WITH NO PLACARDS
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985