Records from 1984 to 2006. Most recent: operational control imposed, 12 October 2006.
Inspection history · 27
19 September 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2781957
15 September 2006
PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2779293
12 September 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2776117
3 September 2006
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2767547
29 August 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2764319
25 August 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2759240
27 July 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2726609
26 July 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2725135
26 July 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2731346
26 July 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3880633
12 June 2006
Ballast Water Examination · ISPS II Exam · PI Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2677701
9 February 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2289571
7 February 2005
NPV Safety Exam · ISPS II Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2283539
20 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1852521
8 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1840350
7 January 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1476048
28 December 2001
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1474384
31 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 148512
30 March 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 276355
5 March 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 489700
20 October 1995
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 383635
4 June 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 367450
30 January 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 341332
6 January 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 327673
21 May 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 316248
31 December 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 520547
6 November 1984
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 298840
Documentation › Certificates/Documents › International Load Line Certificate
Issued 3 September 2006
Resolved
03SEP06 - International Load Line Certificate Expired. Deficiency to be rectified prior to departure to the satisfaction of Class and the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2006
Resolution: International Load Line Certificate was extended. 01 Deficiency cleared.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 25 June 2006
Resolved
The forced ventilation systms responsible for cooling and maintaing the air in a satisfactory condition is not adequate as it is only operating at a low setting and only then on the starboard side of the vessel. Site: ILO-147 pg. 33-4 and pg. 40-4
NOTE: Prior to departure the vessel was seized by US Marshalls; the deficiency is due 30 days from date that it departs Charleston.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 29 September 2006
Resolution: The forced ventilation system is in satisfactory condition throughout the ship.
Documentation
Issued 20 October 1995
Resolved
OIL TRANSFER PROCEDURES NOT COMPLETE PER 33 CFR 155.720-760. CORRECT PRIORTO BUNKERING OR NEXT U.S. PORT.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Documentation
Issued 30 January 1991
Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL OF THE INFORMATION REQUIRED BY 33 CFR 155.720._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Documentation
Issued 6 November 1984
Resolved
VESSEL DID NOT HAVE ANY OIL TRANSFER PROCEDURES ONBOARD AT ALL.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Documentation
Issued 6 November 1984
Resolved
VESSEL DID NOT HAVE AN OIL RECORD BOOK PART 1 (MACHINERY SPACE OPERATION) ONBOARD. VESSEL WAS KEEPING A LOG OF DISCHARGE WITH A LOG BOOK GIVING TO THE SHIP BY THE COMPANY WHO MADE THE OILY WATER SEPERATER.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984