Inspection history · 37
22 September 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8238657
15 March 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8104143
10 September 2024
COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7946537
3 July 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7947358
11 October 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7806823
4 May 2023
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7680816
11 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7575645
9 June 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7470265
4 October 2021
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7323702
21 October 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7081507
7 October 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7073492
24 January 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6895405
26 April 2019
Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6671224
4 October 2017
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6282516
31 March 2016
Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5852310
8 February 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4797082
13 June 2013
DAPI Audit
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4619127
2 April 2013
DAPI Audit
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4572684
25 October 2012
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4472101
18 May 2012
Administration
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4314735
13 March 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2886969
13 March 2007
Damage Survey
Physical examination · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 2887066
13 March 2007
Type not recorded
No type recorded · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 2887068
19 September 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2781957
12 September 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2776117
2 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2448886
2 June 2005
Uninspected Other · MTSA Verification · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2381759
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970612
25 May 1999
Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1131657
6 October 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 78886
22 July 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 146696
12 January 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 196610
12 January 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 752483
15 May 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 111653
24 May 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 664335
7 May 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 4759
6 January 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 34704
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2025
Resolved
Annual audit of the VSP. For each annual audit, a letter certified by the Company Security Officer or the VSO stating the date the audit was completed. Vsl has no record of annual VSP Audit. Rectify prior to pushing, pulling, or hauling of barges subject to 46 CFR chapter I, subchapters D, I, O, or carrying certain dangerous cargo in bulk.
33 CFR 104.235 (b) (8)
Action required: 705 - Other - as specified
Due 22 September 2025
Resolved 24 September 2025
Resolution: Vsl represantive sent VSP audit via email.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 September 2025
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. VSL had not tested fire detection system as required. Corrected on the spot.
46 CFR 143.245 (b)
Action required: 10 - Deficiency Rectified
Due 22 September 2025
Resolved 22 September 2025
Resolution: Heat detector tested during inspection.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 September 2024
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)). MI observed a pinhole leak on the valve located on the starboard fire main feed line. Pressure from the fire pump fluctuated between 20 and 40 psi.
//46 CFR 142.325(a)//
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 October 2024
Resolution: MI observed satisfactory test of fire pump using two hydrants.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 September 2024
Resolved
On vessels with more than one operating station, only one of them must be outfitted with a fire detection control panel. Any other operating station must be outfitted with either a fire detection control panel or a remote indicator panel. Upper operating station did not have a fire detection control panel or a remote indicator panel.
//46 CFR 142.330(a)(3)//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2024
Resolution: MI observed installation of fire control panel on upper operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2024
Resolved
Each lifebuoy on a towing vessel must be marked in block
capital letters with the name of the vessel. The name of
the vessel on the starboard bridge wing lifebuoy was
not properly marked.
//46 CFR 141.360(b)(4)//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2024
Resolution: MI observed starboard lifebuoy properly marked.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 September 2024
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to every towing vessel of 7.8 meters (26 feet) or over in length.
Each ship subject to the Bridge-to-Bridge Act must have on board a radio operator who holds a restricted radiotelephone operator permit or higher-class license.
None of the vessel's crew members currently hold the required radio operator permit.
//47 CFR 80.1001(c)//
//47 CFR 80.163//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2024
Resolution: Vessel master had radio operator permit.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 24 September 2024
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. The posted emergency duties and duty stations did not contain sufficient information to meet the requirements
of this section.
//46 CFR 140.405//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2024
Resolution: Vessel updated emergency bill assignments to be in compliance with the regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and
emergency conditions. MI observed that modifications to
the port air compressor did not align with the
manufacturer's specifications.
//46 CFR 143.205(a)//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2024
Resolution: MI observed satisfactory pressure vessel modifications.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2024
Resolved
Each towing vessel must be operated in compliance with 33 CFR parts 101 and 104, as applicable.
Vessel owners or operators must ensure their vessels are operating in compliance with this part. Vessels VSP expired on May 23, 2023. Vessel must rectify this deficiency prior to towing barges subject to 33 CFR 104.
//46 CFR 141.375(a)//
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2024
Resolution: Vessels VSP was approved.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 September 2024
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. The vessel was equipped with four night flares rather than the required six.
//46 CFR 141.375(a)//
Action required: 10 - Deficiency Rectified
Resolved 24 September 2024
Resolution: Vessel had 6 day/night distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2024
Resolved
Each lifejacket must have a whistle firmly secured by a cord to the lifejacket. MI observed lower operating station lifejacket missing a whistle.
//46 CFR 141.340(g)(2)//
Action required: 10 - Deficiency Rectified
Resolved 24 September 2024
Resolution: Vessel provided whistle for lifejacket.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 September 2024
Resolved
Immersion suits carried on towing vessels must meet the requirements of § 199.70(c) and (d) of this chapter.
Each immersion suit or anti-exposure suit must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. Upper operating station immersion suit light was expired.
//46 CFR 141.350(b)//
//46 CFR 199.70(c)(4)(i)//
Action required: 10 - Deficiency Rectified
Resolved 24 September 2024
Resolution: Vessel replaced immersion suit light.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 July 2024
Resolved
46 CFR 136.200(a): A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. Vessel does not have a valid COI on board. VSL shall complete COI inspection prior to towing operations.
Action required: 705 - Other - as specified
Resolved 8 October 2024
Resolution: Completed COI inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 July 2024
Resolved
46 CFR 140.610(b):The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. FWD STBD hatch on aft main deck is not able to close properly, due to missing dog.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2024
Resolved 10 September 2024
Resolution: Objective evidence received, renewed dog on hatch. Attached photo to this activity.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2023
Resolved
Self-igniting flashing floating electric light to be attached to a lifebuoy. Evaluated, tested and found to be in compliance with: ANSI/UL 1196, SOLAS III/7.1.3, and IMO LSA Code (res. MSC.48(66)), and IMO Res. A.689 (as amended through Res. MSC.81(70)). Uses non-replaceable lithium batteries.
MI observed non-lithuim batteries being used on the ring buoy water-light.
46 CFR 161.110/31/0
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 October 2023
Resolved 11 October 2023
Resolution: Crew replaced battery with proper lithium battery
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2023
Resolved
Each distribution panel or switchboard on a towing vessel must be cosntructed to prevent a persons accidental contact with energized parts. MI observed missing blanks in the engine room switchboard.
46 CFR 141.l36 (c)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 October 2023
Resolved 11 October 2023
Resolution: Crew placed blanked slots on the missing panel blanks
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 October 2023
Resolved
Each towing vessl must perform pressure vessel relief valve tests twice every five years, with no more than three years elapsing since last test. MI observed pressure vessel relief valves that had not properly been tested within the required time contraint.
46 CFR 143.245 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 13 October 2023
Resolution: Vessel installed new pressure relief valves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2022
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Vessels portside s/o valve for the engine and starboard side s/o valve for the generator were inop. Repair or replace.
46CFR143.260 (b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 October 2022
Resolution: O/O replaced lines, conducted sat test of fuel shut off.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 October 2020
Resolved
The following alarms must be provided; low hydraulic steering level. Vessel's low hydraulic steering level alarm does not function. 46 CFR 143.230(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 21 October 2020
Resolution: Vessel's hydraulic steering low level alarm was operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2020
Resolved
Each remote valve control must be marked with 1" letters indicating the purpose. Remote fuel shut off valves are not labeled. 46 CFR 143.260(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 21 October 2020
Resolution: Vessel had shut offs labeled.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 October 2020
Resolved
A fixed fire pump must be capable of functioning. Vessel's fixed fire pump is not functioning. Vessel has portable fire pump IAW 142.325(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 12 October 2021
Resolution: Vessels fixed fire pump was fully operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2020
Resolved
Electrical connectors must be suitably installed to prevent them form coming loose. Vessel's STBD bow winch electrical box is hanging and held on by a hose clamp. 46 CFR 143.400(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 21 October 2020
Resolution: Vessel replaced winch motor and electrical box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 October 2020
Resolved
Machinery components exceeding 220 degrees Celsius must be insulated. STBD outboard exhaust riser has missing lagging. 46 CFR 143.220(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 12 October 2021
Resolution: STBD main engine exahust riser was properly lagged/insulated.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 April 2013
Resolved
Company did not have EAP hotline and policy displayed.
Due 15 May 2013
Resolved 13 June 2013
Resolution: EAP hotline and policy has been displayes.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 2 April 2013
Resolved
Company could not provide documentation showing that supervisors have received the required 1 hour of EAP training. Company could not provide documentation showing that crewmembers have received EAP training prior to assuming duties that are safety sensitive in nature.
Due 15 May 2013
Resolved 13 June 2013
Resolution: All required training has been conducted.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 April 2013
Resolved
Company needs to provide proof that their consortium has received a letter of regulatory compliance.
Due 15 May 2013
Resolved 13 June 2013
Resolution: This item is no longer applicable as per CGHQ
Communications › Alarms/Indicators › General Alarm
Issued 2 June 2005
Resolved
General alarm not audible in all spaces.
Due 6 July 2005
Resolved 14 July 2005
Communications › Visual Communication › Red Warning Signal
Issued 2 June 2005
Resolved
No red warning light in the engine room.
Due 6 July 2005
Resolved 14 July 2005
Lifesaving
Issued 25 May 1999
Resolved
VESSEL MUST BE EQUIPPED WITH AN EPIRB.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Lifesaving
Issued 25 May 1999
Resolved
LIGHTS ON PFD'S HAVE EXPIRED. REQUIRED REPLACEMENT.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999