Records from 2005 to 2025. Most recent: inspection, 17 September 2025.
Inspection history · 50
17 September 2025
Deficiency Check · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8230985
15 March 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8094337
17 January 2025
Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8067533
17 October 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8020368
1 November 2023
Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7815304
11 July 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7739594
10 January 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7619225
27 September 2022
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7566963
10 January 2022
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7375366
3 November 2021
Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7344456
29 September 2020
Internal Structural Exam · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7067533
10 October 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6831194
15 January 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6613410
8 January 2019
Periodic Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6606668
22 November 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6646989
5 September 2018
Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6532492
10 October 2017
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6281936
14 November 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6040569
2 November 2016
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6034023
6 September 2016
Administrative Inspection · Drydock Extension
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6000570
13 October 2015
Cargo Tank Internal · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5741465
9 October 2015
Examination of Repairs · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5739231
10 June 2015
Administrative Inspection · Examination of Repairs · Special
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5156430
16 October 2014
MTSA Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5006359
9 February 2014
Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4797028
8 February 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4797082
8 October 2013
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4731305
28 August 2013
MTSA Verification · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4699265
4 December 2012
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4495947
13 December 2011
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4207025
14 September 2011
Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4145246
10 December 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3908300
23 September 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3855651
22 September 2010
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3858608
16 September 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3851231
12 September 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3849414
14 August 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3825484
2 December 2008
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3372931
9 July 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3262513
24 June 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3246545
14 June 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3238553
3 June 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3260811
15 October 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3080338
30 January 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2863831
27 January 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2863810
25 August 2006
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2759519
13 April 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2624022
11 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2512077
28 September 2005
Hull Examination · Internal Structural Exam · Initial Certification · Cargo Tank Internal · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2522304
2 August 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2449043
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 September 2025
Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have a mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section. Cargo containment below 1S, 2S, 1P, 2P transfer connections had inoperable drain valves. Correct prior to loading cargo at transfer connections associated with containment that has malfunctioning valves.
33 CFR 155.310(a)
Action required: 705 - Other - as specified
Resolved 17 September 2025
Resolution: Attended and witnessed drain valves operating or blank flanged with drain valve open.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 17 September 2025
Resolved
Each cargo tank of a tank barge must have a high-level indicating device, unless the barge complies with 46 CFR 39.2009(a). The high-level indicating device must—indicate visually the level of liquid in the cargo tank when the liquid level is within a range of 1 meter (3.28 feet) of the top of the tank. 5S float level gauge does not fully seat into water due to foreign object in bottom of float cylinder.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 29 September 2025
Resolution: Received objective evidence of repairs. all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 November 2023
Resolved
On a tank barge, each cargo tank must be equipped with an overfill device that, is an installed high-level indicating device that meets the requirements of 46 CFR 39.2003(b)(1), (2), and (3). Vessel's meter gauge on the 01 STBD Tank was found damaged and inoperable.
Control Action: Prior to commencing cargo ops in the 01 STBD Tank. 33CFR155.480 (b)(3)
Action required: 705 - Other - as specified
Due 14 November 2023
Resolved 9 November 2023
Resolution: Vessel rep replaced meter stick, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 January 2022
Resolved
Any tank vessel equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with at minimum one remote manual shutdown station, conspiculously marked, located at the midpoint of vessel, or 100 feet from the engine. Vessel was unable to perform operational test of shutdown.
46 CFR 32.50-35
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2022
Resolution: Vessel demonstrated remote shutdowns to attending MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 September 2020
Resolved
Port rake hatch wasted; repair/replace to satisfaction of CGMI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2020
Resolved 22 October 2020
Resolution: Replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 September 2020
Resolved
P6 void hatch was found to have missing / wasted dog closure. Repair / replace to saitisfaction of CGMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 13 October 2020
Resolution: Replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 29 September 2020
Resolved
S2 cargo metering stick unable to demonstrate proper function. Repair/replace to satisfaction of CGMI prior to conducting cargo operations involving S2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 13 October 2020
Resolution: Replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 January 2019
Resolved
Cargo pump relief valves and pressure gage shall be tested at least once a year. Both relief valves and gages were last tested 4AUG17. Barge has 7 days to rectify.
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 15 January 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 8 January 2019
Resolved
A tank barge with a capacity of 250 or more barrels must have a containment around hose connection points. Discharge hose current configuration has the connection outside containment on aft starboard discharge. Provide containmnet under connection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 January 2019
Deck/Cargo › Cargo Stowage › General
Issued 10 June 2015
Resolved
Provide temporary repairs to drain lines to cargo tanks (X3) IWO holes/wastage to the satisfaction of marine inspector. This is to conducted prior to cargo operations. Cite: 46 CFR 32.60-1(a).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: Wasted/holed areas were de-rusted and polished, and two pack splash zone epoxy was placed on these areas.