MAURY USCG vessel records Sign in
← All vessels

CAPE WRATH

CAPE WRATH is a freight ship. The Coast Guard has recorded 116 inspections since 1984, most recently in June 2024, along with 128 deficiencies — 9 with no resolution recorded —, 4 operational controls, 1 with no removal date recorded and 7 casualty investigations between 2019 and 2024.

Records from 1984 to 2024. Most recent: operational control imposed, 28 June 2024.

Built
Not recorded
Last inspected
28 June 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7826166 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227729
Flag
PANAMA
303940000 (licence lapsed)
Maury page id
psix-227729

Inspections, by type

…with no type recorded36
…past their stated due date3
Years with a record 32 calendar years (1984–2024)
The 116 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)650.0 ft × 105.8 ft × 44.5 ft
Registered tonnagegross 51,960 / net 36,090
ITC dimensions (L × B × D)650.0 ft × 105.8 ft × 44.5 ft
ITC tonnagegross 51,960 / net 36,090
BuilderNot recorded
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36090 - Convention (Subpart B), Net Ton
51960 - Convention (Subpart B), Gross Ton
32772 - Dead Weight, Gross Ton
53652 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WRGJMMSI 303940000 · expired · compulsorily equipped · granted 2 November 1993, cancelled 2 November 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 116

28 June 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7944455
3 April 2024 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7890587
28 March 2024 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7886439
28 March 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8009541
15 March 2024 Type not recorded
No type recorded · Activities Europe · Activity 7889706
14 January 2024 Type not recorded
No type recorded · Activities Europe · Activity 7852525
17 November 2023 ISM SMC Audit · Deficiency Check · Damage Survey
Physical examination · Activities Europe · Activity 7826645
5 November 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7820791
4 November 2023 Type not recorded
No type recorded · Activities Europe · Activity 7832096
3 August 2023 Type not recorded
No type recorded · Activities Europe · Activity 7764540
17 July 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7752846
15 July 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7743116
8 July 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7737779
8 July 2023 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7737786
8 July 2023 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7738433
7 July 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7736330
19 May 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7692048
7 March 2023 Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7648733
23 December 2022 Examination of Repairs · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7622173
17 November 2022 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7595943
14 October 2022 MTSA/ISPS Verification · Annual Inspection · ACP COI Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557162
22 February 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7399070
21 January 2022 ACP Drydock Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7383631
14 January 2022 Permit to Proceed
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7394812
10 November 2021 Administrative Inspection · MTSA/ISPS Verification · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7343750
10 November 2021 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7389538
18 October 2021 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7334642
1 April 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7167197
31 March 2021 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7166433
18 September 2020 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7060640
17 September 2020 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7060305
18 February 2020 MTSA Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6913672
9 October 2019 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6831501
20 September 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6817378
20 September 2019 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6818678
16 July 2019 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6751967
1 May 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6674387
3 April 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6654874
9 January 2019 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6607680
28 August 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6525397
26 May 2018 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6449116
6 February 2018 DAPI Audit · MTSA Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6351781
29 January 2018 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6345332
9 November 2016 Annual Inspection · ACP COI Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6038285
19 January 2016 MTSA/ISPS Verification · DAPI Audit · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5813878
26 October 2014 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5013773
28 August 2014 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4967895
15 August 2014 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4956784
23 April 2009 MTSA Verification · DAPI Audit · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3458766
15 April 2009 MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3453244
20 February 2009 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3421195
11 July 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3264491
14 March 2008 ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3164368
19 March 2007 Administrative Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2888270
26 January 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2859694
7 October 2005 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2513630
1 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480847
1 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480866
18 August 2005 ACP Periodic Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2468208
8 June 2005 MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2393752
22 October 2004 ACP Periodic Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2227065
3 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087432
23 May 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2094748
15 February 2004 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2020375
15 February 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2072105
29 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996174
29 September 2003 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1916128
27 January 2003 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1736254
19 March 2002 Internal Structural Exam · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1677717
9 January 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1476895
6 April 2001 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1061895
21 March 2001 Inclining Experiment · Deadweight Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1408568
21 March 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1452757
10 August 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1053543
8 March 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436360
18 February 2000 Deficiency Check · Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426330
17 February 1999 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1384081
6 October 1998 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 801418
10 September 1998 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1408171
24 April 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123956
3 March 1998 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1392878
9 September 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1112963
18 June 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1110878
19 May 1997 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1385945
18 February 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1107171
22 January 1997 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1377925
1 November 1996 Administrative
Administrative · Activities Europe · Activity 1165708
5 August 1996 Type not recorded
No type recorded · Activities Europe · Activity 54344
26 April 1996 Administrative
Administrative · Activities Europe · Activity 1080852
28 February 1996 COI Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1353880
22 January 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 876935
17 November 1995 Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1380349
13 August 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 168607
13 August 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 220839
29 March 1995 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 833685
18 September 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 142560
1 August 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 11129
15 April 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 68674
7 April 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 33998
3 March 1994 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1166899
20 January 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855128
10 January 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852356
13 May 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1132639
14 May 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 350736
8 October 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 534266
4 March 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 342252
29 October 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 438132
4 May 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 336907
1 March 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 335586
10 August 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 531601
2 March 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 328813
24 August 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 525390
25 February 1988 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 321587
26 April 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 301655
11 October 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 298449
21 May 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 296389

Deficiency record · 128

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2024 No resolution recorded
The machinery, boilers and other pressure vessels, and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. During inspection, ship’s crew stated that there was no determination made for the cause to the multiple blackouts that occurred during the transit to and from Europe. It was also noted at some point there were fuel boost pumps installed for the generators and have since been removed but the controls remained in the ECR. Crew believes this could be the causative factor for the black outs. Trouble shoot generator to identify cause of failures and make repairs. SOLAS 74/81/83 Amended II-2/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 June 2024 No resolution recorded
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. LPCO2 gaging system has inaccurate gauge and showed 110% full. Crew stated that the level was approximately 65%, which was enough for all spaces with the exception of #5 cargo deck. 74 SOLAS 20 II-2/14.2.1.2 a
Action required: 30 - Ship detained
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 June 2024 No resolution recorded
- A ‘critical maintenance list’ of 73-line items, items was provided to the Coast Guard the day of the inspection. These items pertain to the major issues with a variety of critical equipment and key safety systems onboard including machinery, propulsion, and watertight integrity. All items are to be rectified to the satisfaction of the attending ABS surveyor (with CG oversight). Any deviations from this time frame for rectification form specific listed items must be agreed upon by both ABS and CG. ISM Code A/10.1 MARAD-CG MOU VIII ABS Rules for Classification, Part 1A, Section 1.1 and 1.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2024 No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in 91.27-1(a) and (b) and your Certificate of Inspection must be endorsed. Vessel's COI has an expiration date of 31 Jan 2027 and is required to complete annual inspections within a 3 month before or after each anniversary date. Vessel failed to have annual inspection completed by 01 May 2024. 46 CFR 91.27-5 c
Action required: 30 - Ship detained
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 June 2024 No resolution recorded
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence in deficiencies # 1, 2, and 3, the vessel is not in substantial compliance with relevant conventions. An external SMS audit conducted by the vessel’s RO should be conducted prior to being released from detention. This audit should be focused to include engineering preventative maintenance program, procedures, reporting to company, sufficient spare parts and company engagement for maintenance/repairs needed. In addition, this audit should include a focus on ISM clauses 6.1 and 9.1. 74 SOLAS 20 IX/3.1 ISM Code 10.1
Action required: 30 - Ship detained
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 28 June 2024 No resolution recorded
Pilot ladder winch reel as currently arranged does not meet the applicable statutory requirements. The pilot ladder is not secured at the deck level >915mm horizontally inward from the ship’s side, and weight of the pilot ladder can still be partially hanging on the reel. ABS to carry out full evaluation of onboard pilot embarkation arrangements against the applicable standards. 74 SOLAS 20 V/23.1.1.2 IMO Resolution A.1045(27), 7.4 a
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2024 Resolved
While transiting through the Sector Virginia regulated navigation area, your vessel must have tug assist by at least (2) tugs with an aggregate total horsepower of at least 6,000 HP or 40 ton bollard pull.
Action required: 705 - Other - as specified
Due 4 April 2024
Resolved 30 March 2024
Resolution: Vessel made it safely into port.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2024 No resolution recorded
While pressure testing the port side S/W elbow (def 30) observed an approximate 3 inch crack on the 20" discharge/outlet piping of the outboard raw water cooler. Make permanent repairs or provide acceptable temporary repair proposal to USCG & ABS. SOLAS 74/81/83 Amend II-1/26.3 (Update- Temp repair authorized to sail to Port of Baltimore.)
Action required: 15 - Rectify deficiencies by next port
Due 25 March 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 March 2024 No resolution recorded
High pressure CO2 for firefighting system protecting the incinerator space found with one empty cylinder and the paint store cylinder found half empty during annual servicing. Make repairs to incinerator CO2 system, refilling the empty cylinder and verify the CO2 cylinder for the paint store has remained full. 74 SOLAS 74/81/83 II-2/5 & 7
Action required: 15 - Rectify deficiencies by next port
Due 25 March 2024 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 March 2024 No resolution recorded
Deck 5 ramp (at bulkhead deck) forward section two locking pins/securing devices were removed to secure ramp for return voyage. Replace damaged securing devices and make permanent repairs. SOLAS 74/81/83 Amended II-1/25-9.4
Action required: 15 - Rectify deficiencies by next port
Due 25 March 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 November 2023 Resolved
Properly repair engine room door to cargo deck 5 to make reasonably gas-tight. SOLAS 74/81/83 Amended II-2/5.1.4
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2024
Resolution: New door fabricated and inspected by ABS/MI's.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2023 Resolved
Properly stow O2 & Acetylene cylinders in authorized location(s). SOLAS 74/81/83 Amended II-2/51 (Update- O2/Acetelyne stowed on cargo deck. Cargo deck 5 fans shall be operating while underway.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2024
Resolution: Stowage racks installed outside engine room on cargo deck. ABS to update DG-DOC.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 November 2023 Resolved
The following areas shall be cleaned of oil soaked trash/debris: - MDE top of scavenge air box below turbos; - Oil soaked sorbent around JW cooling pipe (aft DG #5); - Open buckets of oil near air receivers; - Bilges/voids under Deck 5 ramp hydraulic rams; - Under emergency fire pump discharge valve. SOLAS 74am (04ConsEd) II-2/4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2024
Resolution: Areas sufficiently cleaned.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 November 2023 Resolved
Aft peak tank valve found with piping into E/R removed and valve dripping. Determine reason piping was removed and reinstall or blank. SOLAS 74am (20ConsEd) II-1/3-1 Update- valve/piping are for cargo deck drains.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2024
Resolution: Valve replaced and piping reinstalled.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 November 2023 Resolved
Repair/replace pin holed fuel piping found in purifier flat marked with 25-23 and secure tank flange leaking directly above. SOLAS 74am (20ConsEd) II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2024
Resolution: Repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 November 2023 Resolved
On day of inspection, only 1 of 5 generators were identified as a reliable power generation source. SSDG#1 requires manual priming to start from a cold condition. SSDG#3 is down for unknown reasons. SSDG#4 and SSDG#5 will not stay on line and intermittently shutdown due to possible fuel pressure issues. Trouble shoot generators to identify cause of failures and make repairs.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 31 January 2024
Resolution: Witnessed SSDG's 1-4 running with successful PSTP testing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2023 Resolved
Installed power management automation system was failing to properly adjust/share generator loads causing blackouts and losses of propulsion. Crew identified failed phase current transformers for SSDG’s #3 & #5 within electrical switchboard and which required “jumping” connections. This alone should not cause failure of the power management system. Identify root cause and make appropriate repairs.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 31 January 2024
Resolution: Witnessed SSDG's running under load, in parallel and with successful PSTP testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 November 2023 Resolved
Observed Auxiliary Lube Oil purifier in alarm status. When questioned, engineer stated temperature probe needed to be moved from other purifiers to make operational. Replace malfunctioning temperature probe. In addition, fuel purifiers may not be operating at manufacturer’s recommended fuel throughput. Follow manufacturer’s recommendations or provide confirmation from manufacturer that a lower throughput is acceptable.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 1 December 2023
Resolution: Observed temperature probes installed in all 04 purifiers and functional.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 November 2023 Resolved
The following areas found with excessive fuel/oil accumulation: tank top under and around main engine/shaft alley, fuel transfer room, purifier room, under SSDG's, aft generator flat, under generator lube oil strainers and bilge in workshop near generator flat. Drain pipe to oily waste tank from oily machinery parts cleaning basin in workshop near generators found cut and allowed to drain straight to bilge. Main engine piston cooling chambers on port side found with flexible hoses to drain to deck level onto sorbent pads. Properly clean all areas of excessive fuel and oily waste.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 5 March 2024
Resolution: Conducted E/R walk-through. Bilges, decks, bulkheads found sufficiently cleaned of fuel/oil accumulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 November 2023 Resolved
Main cooling water pump starboard was tested on standby automatic start. With port pump running, manual valve between both pumps was opened. Observed starboard pump shaft begin to spin indicating failure of check valve between pumps. Weight on check valve handle was not installed. Upon automatic start of pump, excessive vibration was observed and temperature of pump shaft seal rose from 16C to 30C within ten minutes. Port pump was running all day w/ temperature at 16C when starting test. Shutdown starboard due to temperature rise. Trouble shoot heat rise/vibration/valve failures and make repairs.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 31 January 2024
Resolution: Witnessed stbd pump running without steady temperature. Vibration was satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 November 2023 Resolved
Observed portable diaphragm pumps and flexible hoses (some with oil residue) at tank top deck. When questioned, engineers stated the installed sludge pump and sewage pumps were not operational. The dedicated bilge water pump (with a garden hose attached to prime pump) wasn’t able to pull suction from rose boxes. Portable pumps and hoses were used to transfer via sounding tubes of sludge from tank to tank, sewage/grey water from tank to tank. Crew must use back-up general service/fire/bilge pump to transfer oily bilge slops to oily waste tank. Repair/replace non-operational or failing pumps.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 6 March 2024
Resolution: On 05MAR24 observed operation of newly installed sewage pump and bilge pump and remote shutdowns. On 06MAR24 observed installation of new sludge transfer pump. Could not test full function due to empty sludge tanks.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 17 November 2023 Resolved
Oil content meter for OWS was recently replaced by Chief Engineer. No notification was made to IOPP issuing authority (ABS). No valid calibration certificate found. Provide calibration certificate and notify ABS.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 1 December 2023
Resolution: Observed new OCM installed with calibration certificate. ABS surveyors tested OWS system with crew.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 November 2023 Resolved
The grey water and black water skin valves both leak by as identified by crew and confirmed by testing with divers. Grey water tank overflowed into bilge and sludge tanks through interconnected tank vent piping manifold. Questioned crew if any other skin valves were not working properly. It is suspected the main cooling water valve to stbd pump off sea chest is not closing fully. Make repairs/replace leaking skin valves.
Action required: 30 - Ship detained
Due 17 November 2023
Resolved 31 January 2024
Resolution: ABS witnessed satisfactory testing of new valves and verified IACS witnessed shop testing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2023 Resolved
Plastic waste receptacles for used and oily rags found in machinery spaces. Replace with waste receptacles constructed of non-combustible materials.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2023
Resolved 11 January 2024
Resolution: New metal containers for waste and oily rags placed in engine room.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 17 November 2023 Resolved
Focused SMS audit required prior to departure from port. This audit shall focus on the deficiencies marked as SMS Related to include engineering preventative maintenance program, unauthorized repairs/alterations/procedures, reporting to company, sufficient spare parts and company engagement for maintenance/repairs needed.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2023
Resolved 5 March 2024
Resolution: MI's attended closing meeting of ISM Audit on 26FEB24. Final report to be submitted to ACTEUR.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 November 2023 Resolved
Low oil pressure alarmed when testing free-fall lifeboat engine. Investigate cause and make repairs. (Update- Upon testing FFLB engine failed to stop with stop button- corrected) (Update 2- Water ingress identified around stern plate at cort-nozzle, further inspection by BW found GRP cracks on internal GRP layer)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2023
Resolved 6 March 2024
Resolution: MI's inspected fiberglass repairs and tested FFLB in the water. No water ingress identified and engine performed satisfactory. Witnessed simulated launch by primary and emergency controls. Conducted 110% overload test on holding hook.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 July 2023 Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. Systems of this type include the following: Steering Systems. Bilge and Ballast Systems. Tank Vent and Sounding Systems. Overboard Discharges and Shell Connections. Pipe and Pressure Systems. Liquefied Petroleum Gas For Cooking and Heating. Fix and verify proper operation of vessels propulsion equipment. Provide class report to CG Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 15 July 2023
Resolved 17 July 2023
Resolution: Class report sent attesting to completion of repair and testing, finding #1227.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 July 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and readily available for immediate use. During in-water maneuvering test of the freefall lifeboat, the main/primary steering was found to not be working properly. Steering via the emergency tiller verified as working as designed/intended. Make permanent repairs to the main/primary steering to the satisfaction of the attending ABS surveyor prior to departure from the next port of call (reported to be Beaumont, TX).
Action required: 15 - Rectify deficiencies by next port
Due 14 July 2023
Resolved 24 July 2023
Resolution: Per ABS report no. 5952411, an ABS surveyor attended the vessel while berthed in Beaumont and verified that the main steering operation of the FFLB had been restored with OEM parts and proven to be fully operational.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water discharge
Issued 10 March 2023 Resolved
To discharge ballast water into the waters of the United States, the master, owner, operator, agent, or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standards in 151.2030 (a) [e.g. install and use a CG-approved ballast water treatment system] or ballast with water from a U.S. public water system as described in 151.2025(a)(2), according to the schedule in paragraph (b) of this part. The Cape Wrath completed a scheduled dry dock in 2022, and thus is past its compliance date as listed in 151.2035 (b). The vessel’s ballast water records indicate that seawater was taken on in Bayonne, NJ and subsequently discharged in Baltimore, MD in January 2023. The vessel is not equipped with a ballast water treatment system; thus, this water was not managed via one of the allowable methods in 33 CFR 151.2025. Provide a corrective action plan for how the subject vessel will meet the U.S. ballast water regulations moving forward, taking into account the vessel’s purpose of providing sealift service for worldwide deployment. *Note: 151.2025 (a)(3) – ballast water exchange >200nm from any shore – is not a permissible ballast water management method for the subject vessel, as this is only a permitted ballast water management method for vessels not yet past their compliance date. Updated 4/24/23: the due date for this deficiency has been extended to 5/24/23, to facilitate updates to the BWMP to accurately reflect the permissible ballast water management options under 33 CFR 151 for this vessel based on the implementation schedule in 33 CFR 151.2035. Updated 5/19/23: the due date for this deficiency has been extended to 6/10/23, as discussions are reportedly still on-going with MARAD and Crowley regarding this matter, and the vessel has received turbo-activation orders.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 7 July 2023
Resolution: Crowley submitted an updated BWMP which states that vessel will use U.S. public water system (PWS) water to comply with the ballast water management requirements of 33 CFR 151. Unmanaged ballast to be retained onboard or discharged ashore.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 March 2023 Resolved
A minimum of 2 two-way portable radiotelephone apparatus for each fire party for fire-fighter’s communication shall be carried onboard. Those two-way portable radiotelephone apparatus shall be of an explosion-proof or intrinsically safe type. The label for the Motorola fire-fighter radios onboard indicate that a NNTN4852A battery must be used in order to meet explosion-proof / intrinsically safe requirements. However, the batteries currently used with the radios are of different types (NNTN4497DR and NNTN4970A). Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. A PO has been issued for ten (10) Motorola NNTN4852A batteries. Update 4/26/23: Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 8/1/23. Reportedly the aforementioned radio batteries have a long lead-time with current estimated delivery date of 7/25.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 7 July 2023
Resolution: Appropriate firefighter radio batteries were provided onboard to the satisfaction of the attending ABS surveyor, as reported in ABS report no. 5916865.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2023 Resolved
A vessel at anchor shall exhibit where it can best be seen: at or near the stern, an all-around white-light. Aft starboard anchor light is alarming as inoperable on the navigation light panel on the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 24 March 2023
Resolution: Per ABS report no. 5734103, the light was proven fully operational in the presence of the attending Surveyor and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 10 March 2023 Resolved
All ships of 150 gross tons and upwards shall have a daylight signaling lamp not solely dependent upon the ship’s power supply. Daylight signaling lamp is missing battery power pack. Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. A PO has been issued for a new daytime signaling lamp with appropriate backup battery pack.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 26 April 2023
Resolution: Per ABS report no. 5786590, a new ALDIS lamp kit was provided and tested to the satisfaction of the attending ABS Surveyor.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 March 2023 Resolved
Maintenance, testing, and inspection shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Portable containers or portable tanks containing foam concentrate, excluding protein based concentrates, less than 10 years old, that remain factory sealed can normally be accepted without the periodical foam control tests required in MSC.1/Circ.1312 being carried out. ChemGuard AR-AFFF portable foam containers in the DC lockers have a date stamp of 2006, and there is no record of periodical foam testing being carried out. Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. A PO has been issued for six new 20L foam canisters/units. Update 4/26/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 5/24/23. Reportedly the aforementioned 20L foam canisters should be delivered onboard shortly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 26 April 2023
Resolution: Per ABS report no. 5786590, the foam containers were replaced to the satisfaction of the attending ABS Surveyor.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 10 March 2023 Resolved
Systems and equipment used to meet the requirements of this regulation (LRIT) shall confirm to performance standards and functional requirements not inferior to those adopted by the Organization. A Conformance test report should be issued, on satisfactory completion of a conformance test. At time of attendance, there was no objective evidence available onboard of a valid LRIT conformance test report for the current installed equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 24 March 2023
Resolution: Per ABS report no. 5734103, the LRIT was tested by a recognized 3rd party specialist and conformance report provided to the attending ABS Surveyor for review and found in satisfactory operational condition at this time.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 March 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in divisions. Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The ventilation and fire damper panels on the bridge and at the fire control station (ballast control room) have various bulbs not properly functioning when tested. Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. The crew continues to troubleshoot and address some of the malfunctioning/inoperable light indicators at this time.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 26 April 2023
Resolution: Per ABS report no. 5786590, both panels were lamp tested at this time in the presence of the attending ABS Surveyor and found satisfactory with all bulbs found illuminated.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 10 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. At time of attendance on 10 March 2023, multiple radio equipment forming part of the GMDSS suite (examples: MF/HF, INMARSET-C, etc.) lists a date of 25 July 2003.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 24 March 2023
Resolution: Per ABS report no. 5734103, a technician attended the vessel and updated the digital display to reflect the current date to the satisfaction of the attending Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 November 2021 Resolved
Ships shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Administration. Port steering pump inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 November 2021
Resolution: ABS statutory finding no. 1176 opened on 11/15/21. On 12/8/21, ABS report attests to pump motor being overhauled and reinstalled, and steering gear rested to the attending surveyor's satisfaction.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 10 November 2021 Resolved
All arrangements used for pilot transfer shall efficiently fulfill their purpose of enabling pilots to embark and disembark safely. The appliances shall be kept clean, properly maintained and stowed and shall be regularly inspected to ensure they are afe for use [2.1]. Arrangements shall be provided to enable the pilot to embark and disembark safely on either side of the ship [3.1]. Starboard and port side accommodation ladders found with significant wastage/corrosion near turntable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: ABS statutory finding no. 1177 opened on 11/15/21. On 12/8/21, ABS report attests to port ladder taken temporarily out of service pending permanent repairs at DD, and temp repairs completed to starboard ladder, with permanent repairs scheduled for DD.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 November 2021 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: [.1] structural fire protection, including fire-resisting divisions, and protections of openings in these divisions. Starboard door on aft side of accommodation will not close and latch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: ABS statutory finding no. 1178 opened on 11/15/21. On 12/8/21, ABS report attests that the door was adjusted and tested to the attending surveyor's satisfaction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 November 2021 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Light can be seen coming through the door from the galley to exterior and a section of the gasket has popped out of its seating on the door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: ABS statutory finding no. 1179 opened on 11/15/21. On 12/8/21, ABS report attests to that the gasket materiel was refitted and door verified weathertight to the attending surveyor's satisfaction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021 Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Battery charger alarm system in electrical equipment room (#432) found with open junction box. Also, multiple light fixtures in engine room found broken/missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 15 November 2021
Resolution: ABS statutory finding no. 1180 opened on 11/15/21. On 12/8/21, ABS report attests that junction box cover in overhead verified as installed to the satisfaction of the attending surveyor [name withheld] light covers on order for dry-dock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 November 2021 Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization (MSC Circ 1432) and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Monthly inspections of fixed fire detection and alarm system shall to carried out to ensure that a sample of detectors are tested so that all devices have been tested within five years (MSC Circ 1432/5.10). Periodical testing of heat detectors using proper equipment and procedures is not being carried out at requisite intervals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 15 November 2021
Resolution: ABS statutory finding no. 1181 opened on 11/15/21. On 12/8/21, ABS report attests to fire detection system procedures for periodic testing provided to attending surveyor and sampling of detectors tested satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 November 2021 Resolved
Watertight doors of satisfactory construction may be fitted in watertight bulkheads dividing cargo between deck spaces. Watertight door for B deck ramp B5 found with hydraulic leak at connection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 15 November 2021
Resolution: ABS statutory finding no. 1182 opened on 11/15/21. On 12/8/21, ABS report attests to replacement of the leaking hydraulic hose to the satisfaction of the attending surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2021 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules. Deterioration of exterior insulation of SSDG exhaust trunk. Possible exhaust leak into confined space. 46 CFR 58.05-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 21 April 2021
Resolution: See attached ACS report in this activity documents section.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021 Resolved
The termination of each cable must be sealed to prevent the entrance of electrolyte by spray or creepage. Dead end wires were found in the purifier room, forward bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 21 April 2021
Resolution: See attached ACS report in this activity documents section.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 April 2021 Resolved
It is the intent of this subpart that the accommodations provided for officers and crew on all vessels must be securely constructed, properly lighted, heated, drained, ventilated, equipped, located, arranged, and insulated from undue noise, heat, and odors. Drainage pipe coming from port side truck work shop was wasted. Location was approximately 5ft above the waterline.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 21 April 2021
Resolution: See attached ACS report in this activity documents section.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 April 2021 Resolved
Main inlets and outlets of all ventilation systems shall be capable of being closed from outside the space in the event of a fire. Noted accommodation spaces had pull closure operation / inoperable and missing label.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 21 April 2021
Resolution: See attached ACS report in this activity documents section.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 April 2021 Resolved
Each Administration shall, in accordance with the provisions of section A-I/14, hold companies responsible for the assignment of seafarers for service on their ships in accordance with the provisions of the present Convention, and shall require every such company to ensure that each seafarer assigned to any of its ships holds an appropriate certificate in accordance with the provisions of the Convention and as established by the Administration and its ships are manned in compliance with the applicable safe manning requirements of the Administration. Provide MMC for all crew members upon activation of vessel. STCW Reg I/14.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 April 2021 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. The drills of the crew shall take place within 24 hrs of the ship leaving a port if more than 25% of the crew have not participated in drills on board that particular ship in the previous month. Vessel unable to complete drills while in ROS status. Conduct drills upon activation of vessel. SOLAS 74 (2014) III/19.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 18 September 2020 Resolved
Each vessel must have the following equipment, A gyrocompass. Vessel reported that the gyrocompass was providing inaccurate readings while departing port. Prove proper operation to the attending class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2020
Resolution: Received Radio Holland and ABS Reports attesting to the repair of the Gyro Compass
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 February 2020 Resolved
Prior to departure and upon activation provide valid crew licenses and documents.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 September 2020
Resolution: Inspected all crew licenses and document for vessel prior to vessel getting u/w for turbo activation.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 February 2020 Resolved
Upon activation and prior to departure conduct satisfactory fire and abandon ship drills.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 September 2020
Resolution: Witnessed satisfactory fire and abandon ship drill prior to vessel getting u/w for turbo activation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 February 2020 Resolved
Prove proper operation of port/aft cargo hold H/W float switch.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2020
Resolution: Conducted satisfatory test of Float switch. All sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Segregation of oil and water ballast
Issued 18 February 2020 Resolved
Clean fwd and Starboard aft bilge wells in main cargo hold, and determine source of oily contamination in both locations.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2020
Resolution: Attended vessel and inspected clean bilge wells. Origional source of spill was after pressing up F/O tanks with a failed gasket on holding tank. Tank gasket was replaced. All sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 October 2019 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. The drills of the crew shall take place within 24 h of the ship leaving a port if more than 25% of the crew have not participated in abandon ship and fire drills on board that particular ship in the previous month. Upon activation and prior to getting underway, conduct satisfactory fire and abandon ship drills. SOLAS (2014) III/19.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2020
Resolution: witnessed drills.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 20 September 2019 Resolved
Each vessel of 10,000 gross tons or more must have, in addition to the radar system under § 164.35(a), a second marine radar system that operates independently of the first. Provide this office with Class Report attesting to the satisfactory condition of the newly install secondary radar.
Action required: 10 - Deficiency Rectified
Due 20 September 2019
Resolved 20 September 2019
Resolution: This deficiency was rectified on 20SEP2019. Port Engineer provided a copy of the Class Surveyor report via email, ALL SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 September 2019 Resolved
Every officer in charge of a navigational watch serving on a seagoing ship of 500 gross tonnage or more shall hold a certificate of competency. Every officer in charge of an engineering watch in a manned engine-room or designated duty engineer officer in a periodically unmanned engine-room of a seagoing ship powered by main propulsion machinery of 750kw or more shall hold a certificate of competency. Upon activation and prior to getting underway, provide crew licenses and documents IAW vessel COI. STCW II/1 and STCW III/1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2020
Resolution: Inspected licenses, all sat.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 May 2018 Resolved
Provide proof of and verify crew license, documents.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2018
Resolved 9 January 2019
Resolution: Verified valid crew licenses and documents.
Operations/Management › Drills/Instruction › Fire
Issued 26 May 2018 Resolved
Complete Fire and Abandonship drills.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2018
Resolved 9 January 2019
Resolution: Witnessed satisfactory fire and abandonship drill.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 August 2014 Resolved
Upon activation: provide notification to OCMI, Provide crew list and mariner documents as per COI requirements for verification and demonstrate crew competency IWO fire and boat drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2015
Resolution: This was cleared on 26 October 2014 when vessel was activated for Ebola Crisis and did not get checked off in MISLE.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 April 2009 Resolved
Repair the following Explosion proof fixtures in the cargo decks; B-deck, frm 51, stbd side; A-deck, frm 163, port side.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2009
Resolved 21 May 2009
Resolution: new fixtures installed.
Operations/Management › Drills/Instruction › Fire
Issued 23 April 2009 Resolved
Prior to activation, complete satisfactory fire and boat drills in the presence of CG marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2009
Resolved 26 September 2009
Resolution: satisfactory fire and boat drills completed.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 April 2009 Resolved
Prior to activation, provide licenses and mariner documentsfor officers and crew.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2009
Resolved 26 September 2009
Resolution: licenses and documents reviewed and witness satisfactory fire and boat drill.
Lifesaving › Hand Flares › Expired
Issued 23 April 2009 Resolved
Provide 12 rocket flares.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2009
Resolved 21 May 2009
Resolution: new flares provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 April 2009 Resolved
Provide spare Batteries (3) for life boat VHF radios.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2009
Resolved 21 May 2009
Resolution: three new batteries provided.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 April 2009 Resolved
Demonstrate proper operation of OWS following commission of new system.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2009
Resolved 26 September 2009
Resolution: new OWS operation demonstrated.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 23 April 2009 Resolved
Provide proof of valid non-tank vessel response plan. Interim approval expired 21APR08.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 23 April 2009
Resolution: Approval letter provided.
Construction/Loadline › Structures › Deck Plating
Issued 20 February 2009 Resolved
Found a whole, approx. 1/4 inch diameter, in the bottom of containment box located on deck above exterior door for the incinerator room.
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 15 April 2009
Resolution: Repairs completed.
Construction/Loadline › Structures › End Bulkhead
Issued 20 February 2009 Resolved
IVO paint locker door (2ft to right) the bulkhead is wasted at interesection with deck. <see narative fro additional information>
Due 31 March 2009
Resolved 15 April 2009
Resolution: Repairs completed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 March 2008 Resolved
Conduct proper fire and boat drills to satisfaction of USCG Marine Inspector prior to departure, subsequent to activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2009
Resolution: Completed satisfactory fire and boat drills.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 14 March 2008 Resolved
Reinstall all life boat and rescue boat provisions and equipment as well as and reinstallation of life rings/life buoys IAW approved fire control plan locations prior to departure subsequent to activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2009
Resolution: Inspected life boat equipment and found satisfactory.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 14 March 2008 Resolved
Prove installation of life raft inspection/identification cards into designated tubes for the four (4) newly installed life rafts
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Resolution: Installed in new rafts
Fire Fighting › Fire Hydrants › Condition
Issued 14 March 2008 Resolved
Install new spanner wrench into FS # 14 (fwd, portside) as required. Ensure spanner wrenches are installed in all fire stations
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Resolution: New spanner wrench provided.
Fire Fighting › Fire Hydrants › Location/Position
Issued 14 March 2008 Resolved
Re-stencil fire stations with fire station #; Renew lifebuoy stenciling as needed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 11 July 2008
Resolution: re-stincled.
Construction/Loadline › Structures › Door
Issued 14 March 2008 Resolved
Make weather tight, open penetrations in door to “old radio battery room” where door handle has been removed (Port side, fwd; aft of life raft davit).
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 11 July 2008
Resolution: Has been made weather tight.
Construction/Loadline › Structures › Ventilators
Issued 14 March 2008 Resolved
Renew steel work around ventilation closures/fire dampers as needed on weather deck. Renew fire damper gaskets as needed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 20 February 2009
Resolution: Examined renewed ventilation and fire damper areas and found all areas in satisfactory condition.
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 14 March 2008 Resolved
Provide proof of water tight integrity of rescue boat I.W.O. rudder post and engine exhaust penetrations of rescue boat shell/hull.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Resolution: proven watertight
Electrical › Electrical Distribution System (service) › Switch
Issued 14 March 2008 Resolved
Renew rescue boat davit limit switch.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Resolution: Limit switch operating properly.
Electrical › Electric Supply System (service) › Cable
Issued 14 March 2008 Resolved
Renew ground connection on rescue boat davit motor for personnel protection
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 11 July 2008
Resolution: New ground strap installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2008 Resolved
Inspect life buoy/life ring lights where fitted, to prove proper operation (port side aft lighted life ring light is inoperable).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Resolution: lights operable
Engineering › Steering Gear System › Feedback Unit
Issued 14 March 2008 Resolved
Prove proper operation of steering gear hydraulic oil sump low level alarm to sound on navigational bridge as required.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 11 July 2008
Resolution: Proper operation demonstrated.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 14 March 2008 Resolved
Renew rubber/dielectric matting in front of emergency switchboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 11 July 2008
Resolution: New matting provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2008 Resolved
Renew lines/attachments on bridge wing life buoy/light smoke device. Lines are wasted by UV light.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Resolution: Lines renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 March 2008 Resolved
Renew cracked/broken light covers in F/O transfer space and purifier spaces to prevent exp. Hazard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 11 July 2008
Resolution: New covers installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 March 2008 Resolved
Prove dead ending and/or remove wiring associated with old/replaced MSD sewage transfer pump for reasons of crew safety.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 11 July 2008
Resolution: Old wiring removed.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 14 March 2008 Resolved
Prove proper repair of F/O leak on suction side (1/2” F/O supply line @ 90 degree elbow) and coolant leak IWO hose fitting near hot start.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 15 April 2009
Resolution: repairs completed.
Construction/Loadline › Hull › Bottom Plating
Issued 7 March 2002 Resolved
Prior to sailing, repair all bottom plating in 5C, 5S, and 4S DB SWB tanks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Construction/Loadline › Hull
Issued 7 March 2002 Resolved
Empty, clean, gas free and make ready for inspection 6C DB fuel tank.
Due 7 April 2002
Resolved 19 March 2002
Operations/Management › Drills/Instruction
Issued 9 January 2002 Resolved
CONDUCT PROPER ABANDON SHIP DRILL PRIOR TO SAILING. LEGACY COMPONENT DESC: Abandon Ship
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2003
Operations/Management › Drills/Instruction
Issued 9 January 2002 Resolved
CONDUCT PROPER FIRE DRILL PRIOR TO SAILING. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2003
Engineering › Bilge Water Management System
Issued 9 January 2002 Resolved
PROVE PROPER OPERATION OF THE FOLLOWING BILGE ALARMS: (1) ALL AIR ACTUATED ALARMS ON # 1 DECK. (2) 2 FOWARD MOST AIR ACTUATED ALARMS ON # 5 DECK. UNTIL THIS REQUIREMENT IS MET, SHIP'S CREW SHALL REGULARLY PATROL THESE DECKS.
Condition: Unknown
Due 1 March 2002
Resolved 12 April 2002
Lifesaving
Issued 6 April 2001 Resolved
PRIOR TO VESSEL SAILING, RENEW P/SIDE FREE-FALL LOCKING PAD AND P/SIDE SKIDLOCK HYDRAULIC LINE FOR L/B FREE FALL DAVIT ASSEMBLY. "P/SIDE LOCATIONS" ARE RELATIVE TO CONSTRUCTION OF L/B
Condition: Unknown
Due 30 April 2001
Resolved 16 April 2001
Lifesaving
Issued 21 March 2001 Resolved
LAUNCH FREE FALL LIFEBOAT AND OPERATE RETRIEVAL SYSTEM.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Lifesaving
Issued 21 March 2001 Resolved
REPAIR RESCUE BOAT DAVIT LIMIT SWITCH AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Lifesaving
Issued 21 March 2001 Resolved
PROVIDE NEW STABILITYLETTER, TRIM AND STABILITY BOOKLET AND LOADLINE CERTIFICATE
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Fire Fighting
Issued 21 March 2001 Resolved
PROVE PROPER OPERATION OF SMOKE DETECTION SYSTEM ON ALL CARGO DECKS.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Lifesaving
Issued 8 March 2000 Resolved
CONDUCT PERMANENT REPAIRS TO RESCUE BOAT KEEL COOLER
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Documentation
Issued 8 March 2000 Resolved
ENSURE FIRE CONTROL PLAN REFLECTS LOCATION OF FIRE EXTINGUISHERS, AND HOSESUPON COMPLETION OF DECK RENEWALPROJECT. TEMPORARILY EXTEND EVERY THIRD FIRE STATION HOSE 50' IWO DECKS 2, 5, 10 'TIL THIS ITEM IS CLEARED. IAW TEMPORARY STABILITY LETTER DATED 12APR00 NO CARGO MAY BE CARRIED.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Lifesaving
Issued 17 February 1999 Resolved
Conduct weight test to the new stern launched lifeboat cable that was installed 01APR99. Conduct weight test for lifeboat lifting gear. To be completed to the satisfaction of the attending marine inspector and the cognizant OCMI.
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Lifesaving
Issued 17 February 1999 Resolved
Conduct a thourough inspection and make permanent repairs to the fiberglassand metal components as necessary in way of the lifting gear on the stern launched lifeboat and its associated attachment points. To be completed to the satisfaction of the attending marine inspector and the cognizant OCMI.
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Navigation
Issued 3 March 1998 Resolved
PRIOR TO GETTING U/W, PROVIDE UPDATED CHARTS & PUBS FOR INSPECTION BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Unknown
Issued 3 March 1998 Resolved
PRIOR TO GETTING U/W, PROVIDE MEDICINE IN HOSPITAL FOR INSPECTION BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Fire Fighting
Issued 22 January 1997 Resolved
Provide smoke alarm servicing report. To be submitted prior to departure.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Electrical
Issued 22 January 1997 Resolved
Properly dead end electrical cable, deck 11, starboard ladder (hold access).
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Lifesaving
Issued 22 January 1997 Resolved
Provide 24 hand held flares. To be supplied prior to departure.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Electrical
Issued 22 January 1997 Resolved
Properly dead end electrical cable, deck 1, frame 120 (light missing overhead).
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Electrical
Issued 22 January 1997 Resolved
Repair or replace brackets for electrical cable, deck 10, frame 20, centerline.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Lifesaving
Issued 22 January 1997 Resolved
Properly indicate General Alarm bells, 1st and 2nd decks.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Lifesaving
Issued 22 January 1997 Resolved
Provide 12 rocket propelled flares. To be supplied prior to departure.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 22 January 1997 Resolved
Provide fire alarm servicing report. To be provided prior to departure.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Navigation
Issued 22 January 1997 Resolved
Prove proper operation of lose of steering alarm.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 22 January 1997 Resolved
Provide low pressure CO2 servicing report. To be provided prior to departure.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Lifesaving
Issued 22 January 1997 Resolved
Provide smoke for the port and starboard bridge wings. To be provided prior to departure.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 22 January 1997 Resolved
Provide high pressure CO2 servicing report. To be provided prior to departure.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Fire Fighting
Issued 22 January 1997 Resolved
Provide portable fire extinguisher servicing report. To be provided prior to departure.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Fire Fighting
Issued 22 January 1997 Resolved
Replace handles for two fire dampers, deck 12 (outside laundry & outside chief mates office).
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Lifesaving
Issued 28 February 1996 Resolved
MAKE PERMANENT REPAIRS TO ESCAPE CRAFT FIBERGLASS COVER AND RUB RAIL. REPAIRS TO BE COMPLETED AS PER MANUFACTURER'S RECOMMENDATIONS.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 28 February 1996 Resolved
PROVE PROPER OPERATION OF ESCAPE CRAFT RELEASE MECHANISM.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 28 February 1996 Resolved
MAKE PERMANENT REPAIRS TO ESCAPE CRAFT WATER SPRAY SYSTEM. REPAIRS TO BE COMPLETED TO MANUFACTURER'S RECOMMENDATIONS.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Engineering
Issued 22 January 1996 Resolved
Provide machinery logs/problem reports and associated automation documents and materials for review in conjunction with conducting sea trial for approval of automation procedure to satisfaction of attending inspector at time of 1996 COI.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Accommodation/Occupational Safety
Issued 29 March 1995 Resolved
Install exhaust vent stack for fwd battery room one meter above the overhead of the battery room as required for moderate size battery, 46CFR111.15-10(d)(2)(i)(ii)(iii)(iv)
Condition: Unknown
Due 15 July 1996
Resolved 21 May 1995
Electrical
Issued 29 March 1995 Resolved
install approved intrinsically safe or explosion proff light fixtures in the fwd and aft battery rooms and the paint locker as per 46CFR111.105-41 for battery rooms and 46CFR111.105-43 paint lockers.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 29 March 1995 Resolved
Install large radius rollers in rescue boat davit base to prevent cables from chaffing on davit base while lowering and raising the the boat. Structually reinforce davit base opening for roller installation.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Accommodation/Occupational Safety
Issued 29 March 1995 Resolved
Install forced exhaust ventilation in paint locker 46CFR92.15-10(a)(b)(e).
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Navigation
Issued 1 March 1990 Resolved
PER-ARRIVAL EQUIPMENT TEST/EMERGENCY STEERING DRILL NOT CONDUCTED AND LOGGED.
Condition: Unknown
Due 4 May 1990
Resolved 1 March 1990
Navigation
Issued 1 March 1990 Resolved
VESSEL'S #1 RADAR SYSTEM NOT OPERATING.
Condition: Unknown
Due 4 May 1990
Resolved 1 March 1990
Navigation
Issued 1 March 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 May 1990
Resolved 1 March 1990
Documentation
Issued 1 March 1990 Resolved
OIL TRANSFER PROCEDURES NOT ON BOARD.
Condition: Unknown
Due 4 May 1990
Resolved 1 March 1990

Casualty record · 7

1 May 2019Routine · role: Involved in a Marine Casualty · activity 6674387
8 July 2023Routine · role: Involved in a Marine Casualty · activity 7738433
3 August 2023Routine · role: Involved in a Marine Casualty · activity 7764540
4 November 2023Routine · role: Involved in a Marine Casualty · activity 7832096
14 January 2024Routine · role: Involved in a Marine Casualty · activity 7852525
15 March 2024Routine · role: Involved in a Marine Casualty · activity 7889706
28 March 2024Routine · role: Involved in a Marine Casualty · activity 8009541
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.