← All vessels
CAPE WRATH
CAPE WRATH is a freight ship. The Coast Guard has recorded 116 inspections since 1984, most recently in June 2024, along with 128 deficiencies — 9 with no resolution recorded —, 4 operational controls, 1 with no removal date recorded and 7 casualty investigations between 2019 and 2024.
Records from 1984 to 2024. Most recent: operational control imposed, 28 June 2024.
- Built
- Not recorded
- Last inspected
- 28 June 2024
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 116
- Deficiencies
- 128 recorded · 9 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 7 investigations · 2019–2024
Identity
993576
7826166 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRGJ
227729
Flag
PANAMA
303940000 (licence lapsed)
Maury page id
psix-227729
Inspections, by type
…with no type recorded36
…past their stated due date3
Years with a record
32 calendar years (1984–2024)
The 116 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Registered dimensions (L × B × D)650.0 ft × 105.8 ft × 44.5 ft
Registered tonnagegross 51,960 / net 36,090
ITC dimensions (L × B × D)650.0 ft × 105.8 ft × 44.5 ft
ITC tonnagegross 51,960 / net 36,090
BuilderNot recorded
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36090 - Convention (Subpart B), Net Ton
51960 - Convention (Subpart B), Gross Ton
32772 - Dead Weight, Gross Ton
53652 - Displacement, Gross Ton
51960 - Convention (Subpart B), Gross Ton
32772 - Dead Weight, Gross Ton
53652 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WRGJMMSI 303940000 · expired · compulsorily equipped · granted 2 November 1993, cancelled 2 November 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 116
28 June 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7944455
3 April 2024
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7890587
28 March 2024
Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7886439
28 March 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8009541
15 March 2024
Type not recorded
No type recorded · Activities Europe · Activity 7889706
14 January 2024
Type not recorded
No type recorded · Activities Europe · Activity 7852525
17 November 2023
ISM SMC Audit · Deficiency Check · Damage Survey
Physical examination · Activities Europe · Activity 7826645
5 November 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7820791
4 November 2023
Type not recorded
No type recorded · Activities Europe · Activity 7832096
3 August 2023
Type not recorded
No type recorded · Activities Europe · Activity 7764540
17 July 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7752846
15 July 2023
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7743116
8 July 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7737779
8 July 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7737786
8 July 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7738433
7 July 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7736330
19 May 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7692048
7 March 2023
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7648733
23 December 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7622173
17 November 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7595943
14 October 2022
MTSA/ISPS Verification · Annual Inspection · ACP COI Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557162
22 February 2022
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7399070
21 January 2022
ACP Drydock Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7383631
14 January 2022
Permit to Proceed
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7394812
10 November 2021
Administrative Inspection · MTSA/ISPS Verification · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7343750
10 November 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7389538
18 October 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7334642
1 April 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7167197
31 March 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7166433
18 September 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7060640
17 September 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7060305
18 February 2020
MTSA Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6913672
9 October 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6831501
20 September 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6817378
20 September 2019
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6818678
16 July 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6751967
1 May 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6674387
3 April 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6654874
9 January 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6607680
28 August 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6525397
26 May 2018
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6449116
6 February 2018
DAPI Audit · MTSA Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6351781
29 January 2018
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6345332
9 November 2016
Annual Inspection · ACP COI Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6038285
19 January 2016
MTSA/ISPS Verification · DAPI Audit · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5813878
26 October 2014
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5013773
28 August 2014
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4967895
15 August 2014
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4956784
23 April 2009
MTSA Verification · DAPI Audit · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3458766
15 April 2009
MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3453244
20 February 2009
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3421195
11 July 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3264491
14 March 2008
ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3164368
19 March 2007
Administrative Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2888270
26 January 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2859694
7 October 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2513630
1 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480847
1 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480866
18 August 2005
ACP Periodic Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2468208
8 June 2005
MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2393752
22 October 2004
ACP Periodic Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2227065
3 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087432
23 May 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2094748
15 February 2004
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2020375
15 February 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2072105
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996174
29 September 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1916128
27 January 2003
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1736254
19 March 2002
Internal Structural Exam · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1677717
9 January 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1476895
6 April 2001
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1061895
21 March 2001
Inclining Experiment · Deadweight Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1408568
21 March 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1452757
10 August 2000
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1053543
8 March 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436360
18 February 2000
Deficiency Check · Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426330
17 February 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1384081
6 October 1998
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 801418
10 September 1998
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1408171
24 April 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123956
3 March 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1392878
9 September 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1112963
18 June 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1110878
19 May 1997
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1385945
18 February 1997
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1107171
22 January 1997
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1377925
1 November 1996
Administrative
Administrative · Activities Europe · Activity 1165708
5 August 1996
Type not recorded
No type recorded · Activities Europe · Activity 54344
26 April 1996
Administrative
Administrative · Activities Europe · Activity 1080852
28 February 1996
COI Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1353880
22 January 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 876935
17 November 1995
Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1380349
13 August 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 168607
13 August 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 220839
29 March 1995
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 833685
18 September 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 142560
1 August 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 11129
15 April 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 68674
7 April 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 33998
3 March 1994
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1166899
20 January 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855128
10 January 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852356
13 May 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1132639
14 May 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 350736
8 October 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 534266
4 March 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 342252
29 October 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 438132
4 May 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 336907
1 March 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 335586
10 August 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 531601
2 March 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 328813
24 August 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 525390
25 February 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 321587
26 April 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 301655
11 October 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 298449
21 May 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 296389
Deficiency record · 128
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2024
No resolution recorded
The machinery, boilers and other pressure vessels, and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended.
During inspection, ship’s crew stated that there was no determination made for the cause to the multiple blackouts that occurred during the transit to and from Europe. It was also noted at some point there were fuel boost pumps installed for the generators and have since been removed but the controls remained in the ECR. Crew believes this could be the causative factor for the black outs. Trouble shoot generator to identify cause of failures and make repairs. SOLAS 74/81/83 Amended II-2/26.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 June 2024
No resolution recorded
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
LPCO2 gaging system has inaccurate gauge and showed 110% full. Crew stated that the level was approximately 65%, which was enough for all spaces with the exception of #5 cargo deck. 74 SOLAS 20 II-2/14.2.1.2 a
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 June 2024
No resolution recorded
- A ‘critical maintenance list’ of 73-line items, items was provided to the Coast Guard the day of the inspection. These items pertain to the major issues with a variety of critical equipment and key safety systems onboard including machinery, propulsion, and watertight integrity. All items are to be rectified to the satisfaction of the attending ABS surveyor (with CG oversight). Any deviations from this time frame for rectification form specific listed items must be agreed upon by both ABS and CG. ISM Code A/10.1
MARAD-CG MOU VIII
ABS Rules for Classification, Part 1A, Section 1.1 and 1.3
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2024
No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in 91.27-1(a) and (b) and your Certificate of Inspection must be endorsed.
Vessel's COI has an expiration date of 31 Jan 2027 and is required to complete annual inspections within a 3 month before or after each anniversary date. Vessel failed to have annual inspection completed by 01 May 2024. 46 CFR 91.27-5 c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 June 2024
No resolution recorded
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence in deficiencies # 1, 2, and 3, the vessel is not in substantial compliance with relevant conventions. An external SMS audit conducted by the vessel’s RO should be conducted prior to being released from detention. This audit should be focused to include engineering preventative maintenance program, procedures, reporting to company, sufficient spare parts and company engagement for maintenance/repairs needed. In addition, this audit should include a focus on ISM clauses 6.1 and 9.1.
74 SOLAS 20 IX/3.1 ISM Code 10.1
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 28 June 2024
No resolution recorded
Pilot ladder winch reel as currently arranged does not meet the applicable statutory requirements. The pilot ladder is not secured at the deck level >915mm horizontally inward from the ship’s side, and weight of the pilot ladder can still be partially hanging on the reel. ABS to carry out full evaluation of onboard pilot embarkation arrangements against the applicable standards. 74 SOLAS 20 V/23.1.1.2 IMO Resolution A.1045(27), 7.4 a
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2024
Resolved
While transiting through the Sector Virginia regulated navigation area, your vessel must have tug assist by at least (2) tugs with an aggregate total horsepower of at least 6,000 HP or 40 ton bollard pull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2024
No resolution recorded
While pressure testing the port side S/W elbow (def 30) observed an approximate 3 inch crack on the 20" discharge/outlet piping of the outboard raw water cooler. Make permanent repairs or provide acceptable temporary repair proposal to USCG & ABS. SOLAS 74/81/83 Amend II-1/26.3 (Update- Temp repair authorized to sail to Port of Baltimore.)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 March 2024
No resolution recorded
High pressure CO2 for firefighting system protecting the incinerator space found with one empty cylinder and the paint store cylinder found half empty during annual servicing. Make repairs to incinerator CO2 system, refilling the empty cylinder and verify the CO2 cylinder for the paint store has remained full. 74 SOLAS 74/81/83 II-2/5 & 7
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 March 2024
No resolution recorded
Deck 5 ramp (at bulkhead deck) forward section two locking pins/securing devices were removed to secure ramp for return voyage. Replace damaged securing devices and make permanent repairs. SOLAS 74/81/83 Amended II-1/25-9.4
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 November 2023
Resolved
Properly repair engine room door to cargo deck 5 to make reasonably gas-tight. SOLAS 74/81/83 Amended II-2/5.1.4
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2023
Resolved
Properly stow O2 & Acetylene cylinders in authorized location(s). SOLAS 74/81/83 Amended II-2/51
(Update- O2/Acetelyne stowed on cargo deck. Cargo deck 5 fans shall be operating while underway.)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 November 2023
Resolved
The following areas shall be cleaned of oil soaked trash/debris:
- MDE top of scavenge air box below turbos;
- Oil soaked sorbent around JW cooling pipe (aft DG #5);
- Open buckets of oil near air receivers;
- Bilges/voids under Deck 5 ramp hydraulic rams;
- Under emergency fire pump discharge valve.
SOLAS 74am (04ConsEd)
II-2/4.1
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 November 2023
Resolved
Aft peak tank valve found with piping into E/R removed and valve dripping. Determine reason piping was removed and reinstall or blank. SOLAS 74am (20ConsEd)
II-1/3-1
Update- valve/piping are for cargo deck drains.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 November 2023
Resolved
Repair/replace pin holed fuel piping found in purifier flat marked with 25-23 and secure tank flange leaking directly above. SOLAS 74am (20ConsEd)
II-1/3-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 November 2023
Resolved
On day of inspection, only 1 of 5 generators were identified as a reliable power generation source. SSDG#1 requires manual priming to start from a cold condition. SSDG#3 is down for unknown reasons. SSDG#4 and SSDG#5 will not stay on line and intermittently shutdown due to possible fuel pressure issues. Trouble shoot generators to identify cause of failures and make repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2023
Resolved
Installed power management automation system was failing to properly adjust/share generator loads causing blackouts and losses of propulsion. Crew identified failed phase current transformers for SSDG’s #3 & #5 within electrical switchboard and which required “jumping” connections. This alone should not cause failure of the power management system. Identify root cause and make appropriate repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 November 2023
Resolved
Observed Auxiliary Lube Oil purifier in alarm status. When questioned, engineer stated temperature probe needed to be moved from other purifiers to make operational. Replace malfunctioning temperature probe. In addition, fuel purifiers may not be operating at manufacturer’s recommended fuel throughput. Follow manufacturer’s recommendations or provide confirmation from manufacturer that a lower throughput is acceptable.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 November 2023
Resolved
The following areas found with excessive fuel/oil accumulation: tank top under and around main engine/shaft alley, fuel transfer room, purifier room, under SSDG's, aft generator flat, under generator lube oil strainers and bilge in workshop near generator flat. Drain pipe to oily waste tank from oily machinery parts cleaning basin in workshop near generators found cut and allowed to drain straight to bilge. Main engine piston cooling chambers on port side found with flexible hoses to drain to deck level onto sorbent pads. Properly clean all areas of excessive fuel and oily waste.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 November 2023
Resolved
Main cooling water pump starboard was tested on standby automatic start. With port pump running, manual valve between both pumps was opened. Observed starboard pump shaft begin to spin indicating failure of check valve between pumps. Weight on check valve handle was not installed. Upon automatic start of pump, excessive vibration was observed and temperature of pump shaft seal rose from 16C to 30C within ten minutes. Port pump was running all day w/ temperature at 16C when starting test. Shutdown starboard due to temperature rise. Trouble shoot heat rise/vibration/valve failures and make repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 November 2023
Resolved
Observed portable diaphragm pumps and flexible hoses (some with oil residue) at tank top deck. When questioned, engineers stated the installed sludge pump and sewage pumps were not operational. The dedicated bilge water pump (with a garden hose attached to prime pump) wasn’t able to pull suction from rose boxes. Portable pumps and hoses were used to transfer via sounding tubes of sludge from tank to tank, sewage/grey water from tank to tank. Crew must use back-up general service/fire/bilge pump to transfer oily bilge slops to oily waste tank. Repair/replace non-operational or failing pumps.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 17 November 2023
Resolved
Oil content meter for OWS was recently replaced by Chief Engineer. No notification was made to IOPP issuing authority (ABS). No valid calibration certificate found. Provide calibration certificate and notify ABS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 November 2023
Resolved
The grey water and black water skin valves both leak by as identified by crew and confirmed by testing with divers. Grey water tank overflowed into bilge and sludge tanks through interconnected tank vent piping manifold. Questioned crew if any other skin valves were not working properly. It is suspected the main cooling water valve to stbd pump off sea chest is not closing fully. Make repairs/replace leaking skin valves.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2023
Resolved
Plastic waste receptacles for used and oily rags found in machinery spaces. Replace with waste receptacles constructed of non-combustible materials.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 17 November 2023
Resolved
Focused SMS audit required prior to departure from port. This audit shall focus on the deficiencies marked as SMS Related to include engineering preventative maintenance program, unauthorized repairs/alterations/procedures, reporting to company, sufficient spare parts and company engagement for maintenance/repairs needed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 November 2023
Resolved
Low oil pressure alarmed when testing free-fall lifeboat engine. Investigate cause and make repairs. (Update- Upon testing FFLB engine failed to stop with stop button- corrected) (Update 2- Water ingress identified around stern plate at cort-nozzle, further inspection by BW found GRP cracks on internal GRP layer)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 July 2023
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. Systems of this type include the following:
Steering Systems.
Bilge and Ballast Systems.
Tank Vent and Sounding Systems.
Overboard Discharges and Shell Connections.
Pipe and Pressure Systems.
Liquefied Petroleum Gas For Cooking and Heating.
Fix and verify proper operation of vessels propulsion equipment. Provide class report to CG Marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 July 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and readily available for immediate use.
During in-water maneuvering test of the freefall lifeboat, the main/primary steering was found to not be working properly. Steering via the emergency tiller verified as working as designed/intended. Make permanent repairs to the main/primary steering to the satisfaction of the attending ABS surveyor prior to departure from the next port of call (reported to be Beaumont, TX).
14 - Pollution Prevention › 148 - Ballast Water › Ballast water discharge
Issued 10 March 2023
Resolved
To discharge ballast water into the waters of the United States, the master, owner, operator, agent, or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standards in 151.2030 (a) [e.g. install and use a CG-approved ballast water treatment system] or ballast with water from a U.S. public water system as described in 151.2025(a)(2), according to the schedule in paragraph (b) of this part.
The Cape Wrath completed a scheduled dry dock in 2022, and thus is past its compliance date as listed in 151.2035 (b).
The vessel’s ballast water records indicate that seawater was taken on in Bayonne, NJ and subsequently discharged in Baltimore, MD in January 2023. The vessel is not equipped with a ballast water treatment system; thus, this water was not managed via one of the allowable methods in 33 CFR 151.2025.
Provide a corrective action plan for how the subject vessel will meet the U.S. ballast water regulations moving forward, taking into account the vessel’s purpose of providing sealift service for worldwide deployment.
*Note: 151.2025 (a)(3) – ballast water exchange >200nm from any shore – is not a permissible ballast water management method for the subject vessel, as this is only a permitted ballast water management method for vessels not yet past their compliance date.
Updated 4/24/23: the due date for this deficiency has been extended to 5/24/23, to facilitate updates to the BWMP to accurately reflect the permissible ballast water management options under 33 CFR 151 for this vessel based on the implementation schedule in 33 CFR 151.2035.
Updated 5/19/23: the due date for this deficiency has been extended to 6/10/23, as discussions are reportedly still on-going with MARAD and Crowley regarding this matter, and the vessel has received turbo-activation orders.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 March 2023
Resolved
A minimum of 2 two-way portable radiotelephone apparatus for each fire party for fire-fighter’s communication shall be carried onboard. Those two-way portable radiotelephone apparatus shall be of an explosion-proof or intrinsically safe type.
The label for the Motorola fire-fighter radios onboard indicate that a NNTN4852A battery must be used in order to meet explosion-proof / intrinsically safe requirements. However, the batteries currently used with the radios are of different types (NNTN4497DR and NNTN4970A).
Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. A PO has been issued for ten (10) Motorola NNTN4852A batteries.
Update 4/26/23: Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 8/1/23. Reportedly the aforementioned radio batteries have a long lead-time with current estimated delivery date of 7/25.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2023
Resolved
A vessel at anchor shall exhibit where it can best be seen: at or near the stern, an all-around white-light.
Aft starboard anchor light is alarming as inoperable on the navigation light panel on the bridge.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 10 March 2023
Resolved
All ships of 150 gross tons and upwards shall have a daylight signaling lamp not solely dependent upon the ship’s power supply.
Daylight signaling lamp is missing battery power pack.
Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. A PO has been issued for a new daytime signaling lamp with appropriate backup battery pack.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 March 2023
Resolved
Maintenance, testing, and inspection shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Portable containers or portable tanks containing foam concentrate, excluding protein based concentrates, less than 10 years old, that remain factory sealed can normally be accepted without the periodical foam control tests required in MSC.1/Circ.1312 being carried out.
ChemGuard AR-AFFF portable foam containers in the DC lockers have a date stamp of 2006, and there is no record of periodical foam testing being carried out.
Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. A PO has been issued for six new 20L foam canisters/units.
Update 4/26/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 5/24/23. Reportedly the aforementioned 20L foam canisters should be delivered onboard shortly.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 10 March 2023
Resolved
Systems and equipment used to meet the requirements of this regulation (LRIT) shall confirm to performance standards and functional requirements not inferior to those adopted by the Organization. A Conformance test report should be issued, on satisfactory completion of a conformance test.
At time of attendance, there was no objective evidence available onboard of a valid LRIT conformance test report for the current installed equipment.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 March 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in divisions. Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
The ventilation and fire damper panels on the bridge and at the fire control station (ballast control room) have various bulbs not properly functioning when tested.
Update 3/24/23: at the request of the operator (communicated by ABS), this deficiency has been extended until 4/24/23. The crew continues to troubleshoot and address some of the malfunctioning/inoperable light indicators at this time.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 10 March 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
At time of attendance on 10 March 2023, multiple radio equipment forming part of the GMDSS suite (examples: MF/HF, INMARSET-C, etc.) lists a date of 25 July 2003.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 November 2021
Resolved
Ships shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Administration.
Port steering pump inoperable.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 10 November 2021
Resolved
All arrangements used for pilot transfer shall efficiently fulfill their purpose of enabling pilots to embark and disembark safely. The appliances shall be kept clean, properly maintained and stowed and shall be regularly inspected to ensure they are afe for use [2.1]. Arrangements shall be provided to enable the pilot to embark and disembark safely on either side of the ship [3.1].
Starboard and port side accommodation ladders found with significant wastage/corrosion near turntable.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 November 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: [.1] structural fire protection, including fire-resisting divisions, and protections of openings in these divisions.
Starboard door on aft side of accommodation will not close and latch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 November 2021
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration.
Light can be seen coming through the door from the galley to exterior and a section of the gasket has popped out of its seating on the door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021
Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist.
Battery charger alarm system in electrical equipment room (#432) found with open junction box. Also, multiple light fixtures in engine room found broken/missing.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 November 2021
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization (MSC Circ 1432) and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Monthly inspections of fixed fire detection and alarm system shall to carried out to ensure that a sample of detectors are tested so that all devices have been tested within five years (MSC Circ 1432/5.10).
Periodical testing of heat detectors using proper equipment and procedures is not being carried out at requisite intervals.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 November 2021
Resolved
Watertight doors of satisfactory construction may be fitted in watertight bulkheads dividing cargo between deck spaces.
Watertight door for B deck ramp B5 found with hydraulic leak at connection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2021
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules. Deterioration of exterior insulation of SSDG exhaust trunk. Possible exhaust leak into confined space. 46 CFR 58.05-1(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021
Resolved
The termination of each cable must be sealed to prevent the entrance of electrolyte by spray or creepage. Dead end wires were found in the purifier room, forward bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 April 2021
Resolved
It is the intent of this subpart that the accommodations provided for officers and crew on all vessels must be securely constructed, properly lighted, heated, drained, ventilated, equipped, located, arranged, and insulated from undue noise, heat, and odors. Drainage pipe coming from port side truck work shop was wasted. Location was approximately 5ft above the waterline.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 April 2021
Resolved
Main inlets and outlets of all ventilation systems shall be capable of being closed from outside the space in the event of a fire. Noted accommodation spaces had pull closure operation / inoperable and missing label.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 April 2021
Resolved
Each Administration shall, in accordance with the provisions of section A-I/14, hold companies responsible for the assignment of seafarers for service on their ships in accordance with the provisions of the present Convention, and shall require every such company to ensure that each seafarer assigned to any of its ships holds an appropriate certificate in accordance with the provisions of the Convention and as established by the Administration and its ships are manned in compliance with the applicable safe manning requirements of the Administration. Provide MMC for all crew members upon activation of vessel. STCW Reg I/14.1
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 April 2021
Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. The drills of the crew shall take place within 24 hrs of the ship leaving a port if more than 25% of the crew have not participated in drills on board that particular ship in the previous month. Vessel unable to complete drills while in ROS status. Conduct drills upon activation of vessel. SOLAS 74 (2014) III/19.3.2
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 18 September 2020
Resolved
Each vessel must have the following equipment, A gyrocompass. Vessel reported that the gyrocompass was providing inaccurate readings while departing port. Prove proper operation to the attending class surveyor.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 February 2020
Resolved
Prior to departure and upon activation provide valid crew licenses and documents.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 February 2020
Resolved
Upon activation and prior to departure conduct satisfactory fire and abandon ship drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 February 2020
Resolved
Prove proper operation of port/aft cargo hold H/W float switch.
14 - Pollution Prevention › 141 - MARPOL Annex I › Segregation of oil and water ballast
Issued 18 February 2020
Resolved
Clean fwd and Starboard aft bilge wells in main cargo hold, and determine source of oily contamination in both locations.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 October 2019
Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. The drills of the crew shall take place within 24 h of the ship leaving a port if more than 25% of the crew have not participated in abandon ship and fire drills on board that particular ship in the previous month. Upon activation and prior to getting underway, conduct satisfactory fire and abandon ship drills. SOLAS (2014) III/19.3.2
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 20 September 2019
Resolved
Each vessel of 10,000 gross tons or more must have, in addition to the radar system under § 164.35(a), a second marine radar system that operates independently of the first. Provide this office with Class Report attesting to the satisfactory condition of the newly install secondary radar.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 September 2019
Resolved
Every officer in charge of a navigational watch serving on a seagoing ship of 500 gross tonnage or more shall hold a certificate of competency. Every officer in charge of an engineering watch in a manned engine-room or designated duty engineer officer in a periodically unmanned engine-room of a seagoing ship powered by main propulsion machinery of 750kw or more shall hold a certificate of competency. Upon activation and prior to getting underway, provide crew licenses and documents IAW vessel COI. STCW II/1 and STCW III/1
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 May 2018
Resolved
Provide proof of and verify crew license, documents.
Operations/Management › Drills/Instruction › Fire
Issued 26 May 2018
Resolved
Complete Fire and Abandonship drills.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 August 2014
Resolved
Upon activation: provide notification to OCMI, Provide crew list and mariner documents as per COI requirements for verification and demonstrate crew competency IWO fire and boat drills.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 April 2009
Resolved
Repair the following Explosion proof fixtures in the cargo decks; B-deck, frm 51, stbd side; A-deck, frm 163, port side.
Operations/Management › Drills/Instruction › Fire
Issued 23 April 2009
Resolved
Prior to activation, complete satisfactory fire and boat drills in the presence of CG marine Inspector.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 April 2009
Resolved
Prior to activation, provide licenses and mariner documentsfor officers and crew.
Lifesaving › Hand Flares › Expired
Issued 23 April 2009
Resolved
Provide 12 rocket flares.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 April 2009
Resolved
Provide spare Batteries (3) for life boat VHF radios.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 April 2009
Resolved
Demonstrate proper operation of OWS following commission of new system.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 23 April 2009
Resolved
Provide proof of valid non-tank vessel response plan. Interim approval expired 21APR08.
Construction/Loadline › Structures › Deck Plating
Issued 20 February 2009
Resolved
Found a whole, approx. 1/4 inch diameter, in the bottom of containment box located on deck above exterior door for the incinerator room.
Construction/Loadline › Structures › End Bulkhead
Issued 20 February 2009
Resolved
IVO paint locker door (2ft to right) the bulkhead is wasted at interesection with deck. <see narative fro additional information>
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 March 2008
Resolved
Conduct proper fire and boat drills to satisfaction of USCG Marine Inspector prior to departure, subsequent to activation.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 14 March 2008
Resolved
Reinstall all life boat and rescue boat provisions and equipment as well as and reinstallation of life rings/life buoys IAW approved fire control plan locations prior to departure subsequent to activation.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 14 March 2008
Resolved
Prove installation of life raft inspection/identification cards into designated tubes for the four (4) newly installed life rafts
Fire Fighting › Fire Hydrants › Condition
Issued 14 March 2008
Resolved
Install new spanner wrench into FS # 14 (fwd, portside) as required. Ensure spanner wrenches are installed in all fire stations
Fire Fighting › Fire Hydrants › Location/Position
Issued 14 March 2008
Resolved
Re-stencil fire stations with fire station #; Renew lifebuoy stenciling as needed.
Construction/Loadline › Structures › Door
Issued 14 March 2008
Resolved
Make weather tight, open penetrations in door to “old radio battery room” where door handle has been removed (Port side, fwd; aft of life raft davit).
Construction/Loadline › Structures › Ventilators
Issued 14 March 2008
Resolved
Renew steel work around ventilation closures/fire dampers as needed on weather deck. Renew fire damper gaskets as needed.
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 14 March 2008
Resolved
Provide proof of water tight integrity of rescue boat I.W.O. rudder post and engine exhaust penetrations of rescue boat shell/hull.
Electrical › Electrical Distribution System (service) › Switch
Issued 14 March 2008
Resolved
Renew rescue boat davit limit switch.
Electrical › Electric Supply System (service) › Cable
Issued 14 March 2008
Resolved
Renew ground connection on rescue boat davit motor for personnel protection
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2008
Resolved
Inspect life buoy/life ring lights where fitted, to prove proper operation (port side aft lighted life ring light is inoperable).
Engineering › Steering Gear System › Feedback Unit
Issued 14 March 2008
Resolved
Prove proper operation of steering gear hydraulic oil sump low level alarm to sound on navigational bridge as required.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 14 March 2008
Resolved
Renew rubber/dielectric matting in front of emergency switchboard.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2008
Resolved
Renew lines/attachments on bridge wing life buoy/light smoke device. Lines are wasted by UV light.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 March 2008
Resolved
Renew cracked/broken light covers in F/O transfer space and purifier spaces to prevent exp. Hazard.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 March 2008
Resolved
Prove dead ending and/or remove wiring associated with old/replaced MSD sewage transfer pump for reasons of crew safety.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 14 March 2008
Resolved
Prove proper repair of F/O leak on suction side (1/2” F/O supply line @ 90 degree elbow) and coolant leak IWO hose fitting near hot start.
Construction/Loadline › Hull › Bottom Plating
Issued 7 March 2002
Resolved
Prior to sailing, repair all bottom plating in 5C, 5S, and 4S DB SWB tanks.
Construction/Loadline › Hull
Issued 7 March 2002
Resolved
Empty, clean, gas free and make ready for inspection 6C DB fuel tank.
Operations/Management › Drills/Instruction
Issued 9 January 2002
Resolved
CONDUCT PROPER ABANDON SHIP DRILL PRIOR TO SAILING. LEGACY COMPONENT DESC: Abandon Ship
Operations/Management › Drills/Instruction
Issued 9 January 2002
Resolved
CONDUCT PROPER FIRE DRILL PRIOR TO SAILING. LEGACY COMPONENT DESC: Fire
Engineering › Bilge Water Management System
Issued 9 January 2002
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING BILGE ALARMS: (1) ALL AIR ACTUATED ALARMS ON # 1 DECK. (2) 2 FOWARD MOST AIR ACTUATED ALARMS ON # 5 DECK. UNTIL THIS REQUIREMENT IS MET, SHIP'S CREW SHALL REGULARLY PATROL THESE DECKS.
Lifesaving
Issued 6 April 2001
Resolved
PRIOR TO VESSEL SAILING, RENEW P/SIDE FREE-FALL LOCKING PAD AND P/SIDE SKIDLOCK HYDRAULIC LINE FOR L/B FREE FALL DAVIT ASSEMBLY. "P/SIDE LOCATIONS" ARE RELATIVE TO CONSTRUCTION OF L/B
Lifesaving
Issued 21 March 2001
Resolved
LAUNCH FREE FALL LIFEBOAT AND OPERATE RETRIEVAL SYSTEM.
Lifesaving
Issued 21 March 2001
Resolved
REPAIR RESCUE BOAT DAVIT LIMIT SWITCH AND DEMONSTRATE PROPER OPERATION.
Lifesaving
Issued 21 March 2001
Resolved
PROVIDE NEW STABILITYLETTER, TRIM AND STABILITY BOOKLET AND LOADLINE CERTIFICATE
Fire Fighting
Issued 21 March 2001
Resolved
PROVE PROPER OPERATION OF SMOKE DETECTION SYSTEM ON ALL CARGO DECKS.
Lifesaving
Issued 8 March 2000
Resolved
CONDUCT PERMANENT REPAIRS TO RESCUE BOAT KEEL COOLER
Documentation
Issued 8 March 2000
Resolved
ENSURE FIRE CONTROL PLAN REFLECTS LOCATION OF FIRE EXTINGUISHERS, AND HOSESUPON COMPLETION OF DECK RENEWALPROJECT. TEMPORARILY EXTEND EVERY THIRD FIRE STATION HOSE 50' IWO DECKS 2, 5, 10 'TIL THIS ITEM IS CLEARED. IAW TEMPORARY STABILITY LETTER DATED 12APR00 NO CARGO MAY BE CARRIED.
Lifesaving
Issued 17 February 1999
Resolved
Conduct weight test to the new stern launched lifeboat cable that was installed 01APR99. Conduct weight test for lifeboat lifting gear. To be completed to the satisfaction of the attending marine inspector and the cognizant OCMI.
Lifesaving
Issued 17 February 1999
Resolved
Conduct a thourough inspection and make permanent repairs to the fiberglassand metal components as necessary in way of the lifting gear on the stern launched lifeboat and its associated attachment points. To be completed to the satisfaction of the attending marine inspector and the cognizant OCMI.
Navigation
Issued 3 March 1998
Resolved
PRIOR TO GETTING U/W, PROVIDE UPDATED CHARTS & PUBS FOR INSPECTION BY USCG MARINE INSPECTOR.
Unknown
Issued 3 March 1998
Resolved
PRIOR TO GETTING U/W, PROVIDE MEDICINE IN HOSPITAL FOR INSPECTION BY USCG MARINE INSPECTOR.
Fire Fighting
Issued 22 January 1997
Resolved
Provide smoke alarm servicing report. To be submitted prior to departure.
Electrical
Issued 22 January 1997
Resolved
Properly dead end electrical cable, deck 11, starboard ladder (hold access).
Lifesaving
Issued 22 January 1997
Resolved
Provide 24 hand held flares. To be supplied prior to departure.
Electrical
Issued 22 January 1997
Resolved
Properly dead end electrical cable, deck 1, frame 120 (light missing overhead).
Electrical
Issued 22 January 1997
Resolved
Repair or replace brackets for electrical cable, deck 10, frame 20, centerline.
Lifesaving
Issued 22 January 1997
Resolved
Properly indicate General Alarm bells, 1st and 2nd decks.
Lifesaving
Issued 22 January 1997
Resolved
Provide 12 rocket propelled flares. To be supplied prior to departure.
Fire Fighting
Issued 22 January 1997
Resolved
Provide fire alarm servicing report. To be provided prior to departure.
Navigation
Issued 22 January 1997
Resolved
Prove proper operation of lose of steering alarm.
Fire Fighting
Issued 22 January 1997
Resolved
Provide low pressure CO2 servicing report. To be provided prior to departure.
Lifesaving
Issued 22 January 1997
Resolved
Provide smoke for the port and starboard bridge wings. To be provided prior to departure.
Fire Fighting
Issued 22 January 1997
Resolved
Provide high pressure CO2 servicing report. To be provided prior to departure.
Fire Fighting
Issued 22 January 1997
Resolved
Provide portable fire extinguisher servicing report. To be provided prior to departure.
Fire Fighting
Issued 22 January 1997
Resolved
Replace handles for two fire dampers, deck 12 (outside laundry & outside chief mates office).
Lifesaving
Issued 28 February 1996
Resolved
MAKE PERMANENT REPAIRS TO ESCAPE CRAFT FIBERGLASS COVER AND RUB RAIL. REPAIRS TO BE COMPLETED AS PER MANUFACTURER'S RECOMMENDATIONS.
Lifesaving
Issued 28 February 1996
Resolved
PROVE PROPER OPERATION OF ESCAPE CRAFT RELEASE MECHANISM.
Lifesaving
Issued 28 February 1996
Resolved
MAKE PERMANENT REPAIRS TO ESCAPE CRAFT WATER SPRAY SYSTEM. REPAIRS TO BE COMPLETED TO MANUFACTURER'S RECOMMENDATIONS.
Engineering
Issued 22 January 1996
Resolved
Provide machinery logs/problem reports and associated automation documents and materials for review in conjunction with conducting sea trial for approval of automation procedure to satisfaction of attending inspector at time of 1996 COI.
Accommodation/Occupational Safety
Issued 29 March 1995
Resolved
Install exhaust vent stack for fwd battery room one meter above the overhead of the battery room as required for moderate size battery, 46CFR111.15-10(d)(2)(i)(ii)(iii)(iv)
Electrical
Issued 29 March 1995
Resolved
install approved intrinsically safe or explosion proff light fixtures in the fwd and aft battery rooms and the paint locker as per 46CFR111.105-41 for battery rooms and 46CFR111.105-43 paint lockers.
Lifesaving
Issued 29 March 1995
Resolved
Install large radius rollers in rescue boat davit base to prevent cables from chaffing on davit base while lowering and raising the the boat. Structually reinforce davit base opening for roller installation.
Accommodation/Occupational Safety
Issued 29 March 1995
Resolved
Install forced exhaust ventilation in paint locker 46CFR92.15-10(a)(b)(e).
Navigation
Issued 1 March 1990
Resolved
PER-ARRIVAL EQUIPMENT TEST/EMERGENCY STEERING DRILL NOT CONDUCTED AND LOGGED.
Navigation
Issued 1 March 1990
Resolved
VESSEL'S #1 RADAR SYSTEM NOT OPERATING.
Navigation
Issued 1 March 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 1 March 1990
Resolved
OIL TRANSFER PROCEDURES NOT ON BOARD.
Casualty record · 7
1 May 2019Routine · role: Involved in a Marine Casualty · activity 6674387
8 July 2023Routine · role: Involved in a Marine Casualty · activity 7738433
3 August 2023Routine · role: Involved in a Marine Casualty · activity 7764540
4 November 2023Routine · role: Involved in a Marine Casualty · activity 7832096
14 January 2024Routine · role: Involved in a Marine Casualty · activity 7852525
15 March 2024Routine · role: Involved in a Marine Casualty · activity 7889706
28 March 2024Routine · role: Involved in a Marine Casualty · activity 8009541
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.