MAURY USCG vessel records Sign in
← All vessels

ATLIXCO

ATLIXCO is a 1982 freight ship. The Coast Guard has recorded 53 inspections since 1985, most recently in October 2008, along with 23 deficiencies and 3 operational controls.

Records from 1985 to 2008. Most recent: inspection, 4 October 2008.

Built
1982
Last inspected
4 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8005032 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228223
Flag
JAPAN
—
Maury page id
psix-228223

Inspections, by type

…with no type recorded32
Years with a record 22 calendar years (1985–2008)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it41697 - Convention (Subpart B), Gross Ton
41697 - Simplified, Gross Ton
12509 - Convention (Subpart B), Net Ton
36146 - Displacement, Ton
18217 - Dead Weight, Ton
12509 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 6

Inspection history · 53

4 October 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3338446
22 November 2007 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3102772
6 September 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3048684
10 June 2007 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2957124
25 May 2007 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2940030
24 April 2007 NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2914804
1 March 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2880154
23 September 2006 Type not recorded
No type recorded · USCGC TAHOMA (WMEC 908) · Activity 2785314
14 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2648839
21 November 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2539192
21 November 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2546338
25 August 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2474420
15 July 2005 ISPS II Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2427934
16 March 2005 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2311305
19 October 2004 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2223586
25 September 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2204958
20 September 2004 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2199950
6 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2158067
11 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2128925
26 March 2004 Annual Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2033029
16 June 2003 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1818575
17 October 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1691396
29 May 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1622501
24 May 2002 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1620521
4 March 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1490752
1 March 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1490496
4 February 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1483646
3 October 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 294252
28 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294426
2 March 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 287734
29 August 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 281563
5 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 426443
9 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 413575
2 October 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 395767
13 February 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 387677
8 November 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 385091
20 October 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 383941
16 October 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 383691
3 November 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 518636
18 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 368996
10 March 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 365137
7 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 519862
13 May 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 531682
1 March 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 356622
24 March 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 349858
8 August 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 345615
23 January 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 445868
15 June 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 337736
7 November 1988 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 326674
27 June 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 479478
7 October 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 318863
28 December 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 313011
10 January 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300263

Deficiency record · 23

Engineering › Lubricating Oil Service System › Pump
Issued 24 April 2007 Resolved
Vessel's #1 main lube oil pump is excessively leaking at seal. Repair or replace to the satisfaction of attending Classification Society surveyor.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 10 June 2007
Resolution: Received class report attesting to repairs
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 24 April 2007 Resolved
The main jacket cooling water pipe is leaking at the valve directly behind the #1 jacket water pump on port side of engine room. Repair to the satisfaction of attending Classification Society surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2007
Resolution: Permanent repairs were made to the satisfaction of the class surveyor.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 April 2007 Resolved
A temporary pipe was found on the boiler deck, leading from the sludge settling tank into the economizer containment. Vessel must have attending Classification Society surveyor attest to the installation of the pipe.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2007
Resolution: Received class report attesting the temporary pipe being removed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 April 2007 Resolved
A temporary rubber hose was found on the boiler deck, leading into the vessel's bilge. Vessel must have attending Classification Society surveyor attest to the installation of the pipe.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2007
Resolution: Rubber hose was replaced with a permanent steel hose to the satisfaction of class.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 April 2007 Resolved
Two temporary rubber hoses were found leading into aft bilge well. Engineering crew stated that the hoses lead to oil purifier vicinity. Vessel must have Classification Society surveyor inspect and attest to the installation of the hoses.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2007
Resolution: Received class report attesting to the temporary hoses being removed.
Fire Fighting › Fire Main › Condition
Issued 24 April 2007 Resolved
The fire main pipe on the bridge deck, leading to the laundry room and gymnasium, was found to be corroded and holed. Vessel must replace section to the satisfaction of attending Classification Society surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2007
Resolution: Permanant repairs were made to the satisfaction of the Class Society.
Fire Fighting › Combustible Materials › Insulation
Issued 24 April 2007 Resolved
Excessive pooled fuel oil and oil soaked lagging was found near the fuel oil rack on the Vessel's #02 service generator. Vessel must remove pooled oil and replace soaked lagging to the satisfaction of attending Classification Society surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2007
Resolution: Received class report attesting to the soaked lagging being replaced and the leaks were repaired.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 April 2007 Resolved
Desiccator on Oily Water Separator oil content meter is displaying the color white indicating desiccator expiration. Vessel must replace part to the satisfaction of attending Classification Society surveyor, prior to operating Oily Water Separator.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2007
Resolution: Desicator on oil content meter for OWS was renewed to the satisfaction of class.
Engineering › Steam System (main) › Piping
Issued 24 April 2007 Resolved
Steam leak on supply pump from boiler to economizer. Repair to the satisfaction of attending classification society surveyor.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 10 June 2007
Resolution: Received class report attesting to repairs.
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2007 Resolved
Wastage of the vessel's hull in the engine room port side forward under the deck grating was discovered. Have attending classification society surveyor assess and make recommendation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2007
Resolution: Temporary repairs were made to the satisfaction of the class society. Permenant repairs are to be made at the vessels next dry dock.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 April 2007 Resolved
Vessel's fire control plan does not clearly differentiate between class A and class B boundaries. Vessel must make revisions to clearly show difference and have attending Classification Society approve.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 10 June 2007
Resolution: Received class report addressing and updating the fire control plan.
Construction/Loadline › Hull › Hull Plating
Issued 21 November 2005 Resolved
Starboard shell plating between frames 17-20, between decks six and seven, inset from impact with another vessel. No hull penetration noted. Frames and frame welds not compromised based on internal inspection from within cargo hold. Unable to verify external condition of shell plating. Damage is two decks above deck line.
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 22 November 2005
Resolution: NKK Surveyor provided report of survey with satisfactory damage assessment and attested to general seaworthiness of vessel.
Engineering › Freshwater Generation System › Pump
Issued 16 March 2005 Resolved
Freshwater generator has multiple temporary repairs, one of which is leaking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 15 July 2005
Resolution: 15JUL05: FW generator replaced during drydock period of JUN05 to satisfaction of NKK.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 16 March 2005 Resolved
Emergency fire pump is not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2005
Resolved 16 March 2005
Resolution: The EFP was overhauled and performance tested and found to be in order. Inspection was completed by Class Surveyor with copy of report forwarded to USCG Sector Baltimore.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 16 March 2005 Resolved
Load line and draft marks are not painted in a contrasting color to the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 15 July 2005
Resolution: 15JUL05: Loadline and draft marks sandblasted and repainted during drydock period JUN05 to satisfaction of NKK.
Fire Fighting › Fire Main › Condition
Issued 16 March 2005 Resolved
Fire main has a soft patch that is leaking on the discharge side of the main fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 15 July 2005
Resolution: 15JUL05: Fireline extensively repaired during drydock period JUN05 to satisfaction of NKK.
Construction/Loadline › Hull › Hull Plating
Issued 26 March 2004 Resolved
1 foot wide by 4 inch deep indent in starboard quarter hull plating, approximately 100 feet forward of the aft cargo ramp. Address to the satisfaction of class within 30 days.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 26 May 2004
Resolution: Received class report addressing repairs.
Construction/Loadline › Structures › Door
Issued 26 March 2004 Resolved
Upper dog missing from starboard bunkering station watertight hatch penetrating hull. Watertight door leading from cargo deck to bunkering station still watertight. Address to the satisfaction of class within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 11 July 2004
Resolution: Repairs conducted and verified by Marine Inspector.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 26 March 2004 Resolved
Cargo deck smoke detection system is currently being tested by disconnecting piping at test unit on bridge and blowing cigarette smoke into system. Address cargo deck smoke detection testing procedures to the satisfaction of class within 7 days. LEGACY COMPONENT DESC: Fixed smoke detection system testing procedures
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 11 July 2004
Resolution: Resolved on behalf of PS1 [name withheld] of MSO San Juan, PR ([phone withheld]) due to issues with MISLE data entry. PO Baltar stated a service report was summited indicating the smoke detector is in good operational condition.
Fire Fighting
Issued 3 October 2001 Resolved
FIREMANS OUTFIT LIFELINE (TENDING LINE) (2) ARE NOT CONTRUCTED OF FIREPROOFMATERIAL. SOLAS CHAPTER II-2/17.2
Condition: Unknown
Due 8 October 2001
Resolved 1 March 2002
Resolution: cleared via fax.
Fire Fighting
Issued 9 March 1998 Resolved
Emergency fire pump was unable tp start and provide aduquite water pressurewhile team was on board. Repair to the satisfaction of class, fax class report to MSO San Francisco bay. SOLAS 74 unamended II-2 reg 52(b)(ii)
Condition: Unknown
Due 9 March 1998
Resolved 24 March 1998
Fire Fighting
Issued 2 October 1996 Resolved
REPLACE TWO FIRE HOSES THAT ARE BADLY LEAKING/WEEPING.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Accommodation/Occupational Safety
Issued 16 October 1995 Resolved
VESSEL'S TOILET IN THE ENGINE ROOM IS PIPED DIRECTLY OVERBOARD. VESSEL IS TO MAKE TOILET INOPERABLE (WITH O/B VALVE LOCKED) WHILE IN US WATERS AND TOPROVIDE TOILET WITH AN APPROVED MSD OR REMOVE TOILET FROM THE SPACE PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996

Ownership record