MAURY USCG vessel records Sign in
← All vessels

GEORGIA S

GEORGIA S is a 1981 freight ship. The Coast Guard has recorded 92 inspections since 1984, most recently in February 2011, along with 45 deficiencies and 7 operational controls, 1 with no removal date recorded.

Records from 1984 to 2011. Most recent: inspection, 25 February 2011.

Built
1981
Last inspected
25 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8009521 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228271
Flag
PANAMA
—
Maury page id
psix-228271

Inspections, by type

…with no type recorded64
Years with a record 27 calendar years (1984–2011)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30187 - Dead Weight, Ton
59897 - Displacement, Ton
20053 - Convention (Subpart B), Gross Ton
20053 - Regulatory (Subpart C or D), Gross Ton
8500 - Convention (Subpart B), Net Ton
8500 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHEROKEE Industrial Vessel · MISLE 55594 · 3 February 2007 · activity 2866754FORT BRAGG Towing Vessel · MISLE 486812 · 3 February 2007 · activity 2866754ZHEN HUA 16 Freight Ship · MISLE 871818 · 3 February 2007 · activity 2866754DEBBIE ANN Commercial Fishing Vessel · MISLE 171414 · 13 July 2003 · activity 1882668

Inspection history · 92

25 February 2011 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3951892
28 January 2011 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3934764
17 December 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3912599
22 January 2010 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3667886
15 December 2008 ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3380099
3 June 2008 MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3225838
14 December 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3115591
16 November 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3099514
28 May 2007 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2943624
3 February 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2866754
8 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2852130
30 October 2006 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2810369
9 August 2006 Random ISPS/MTSA-No PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2741473
26 January 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2574105
11 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2532894
26 October 2005 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2522286
24 October 2005 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2522446
14 October 2005 PII Safety Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2514308
21 March 2005 Ballast Water Examination · ISPS II Exam · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2315312
16 March 2005 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2311788
27 October 2004 PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2229274
1 July 2004 ISPS II Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2115337
29 April 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2055129
21 April 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2049448
7 March 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2019832
16 January 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1989564
1 December 2003 Damage Survey
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1959366
2 October 2003 Passenger/Freight Vessel Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1919650
13 July 2003 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1882668
16 June 2003 Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1818699
8 April 2003 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1770674
1 April 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1766620
24 March 2003 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1761972
23 March 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1789401
3 October 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1684275
5 April 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1602151
2 November 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 295099
3 October 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 294193
6 August 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292479
17 September 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 282158
16 March 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 275713
11 September 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 13063
10 September 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 432654
1 April 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 426833
19 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 186844
19 December 1998 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 807562
16 October 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 421386
8 September 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 420108
27 June 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 73873
9 May 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 34199
9 May 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 415639
4 September 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 407492
25 March 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 401818
18 September 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 395451
9 September 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 395119
13 May 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 391241
1 October 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 383284
7 September 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 645619
6 September 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 467207
1 September 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 382268
1 September 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 645622
25 March 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 376449
26 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 369908
3 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 369037
30 May 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 83702
29 April 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 366375
1 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 360667
27 July 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 510153
19 May 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 358376
24 September 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 445922
24 May 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 350852
10 October 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 346341
13 July 1991 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 503023
10 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493111
29 October 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 340021
10 October 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 339725
21 April 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 523711
27 October 1989 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 333969
17 April 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 329822
13 December 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 327305
9 July 1988 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 523768
16 January 1988 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 320734
9 May 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 315973
12 April 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 315363
13 October 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 503946
6 June 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 517058
25 January 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 306615
2 October 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 507900
13 May 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 511578
17 November 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 298892
13 June 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 526919
17 May 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 534615

Deficiency record · 45

Lifesaving › Lifeboat › Fender
Issued 25 February 2011 Resolved
0610; Both lifeboats were inspected on 2/23/10 for their annual inspection. During the inspection the canopy covers were not addressed nor were the canopy support bars. The skates were not listed as being inadequate. Skates were found in such condition that they may shatter upon impact. FWD middle sheave on P/LB davit is not work and seats in both boats are rotten, 17 A/B.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2011
Resolution: Inspected by Class and Condition of Class was issued. Repairs will be made during dry-dock and 2/25 life rafts were installed as temporary measures approved by Flag State.
Navigation › Piloting/Steering › Marine Charts
Issued 25 February 2011 Resolved
1560; Voyage plan was not signed by any Deck Officers and echo-depth sounder was not turned on for continuous soundings or recording during voyage, 70 A/B.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 25 February 2011 Resolved
0660; All lifejackets are tie type. New requirements require all lifejackets a positive means of closure which do not require knots, LSA 2010, 2.2.1.5.4, 70 A/B.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 February 2011 Resolved
0330; Sewage treatment plan is not being maintained in accordance with manufacturer's requirements. Daily, weekly, monthly, semi-annual, annual and chlorine test have not been carried out. In addition one pipe is leaking and tubes for tablets are patched, 70 A/B.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 25 February 2011 Resolved
0900; Conduit line leading into forward Bos'n store holed and wastage around weld. Ventilation ducting for conveyor belt in forward Bos'n store water pin holes and wastage found, 70 A/B.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Documentation › Logs/Records › Oil Record Book
Issued 25 February 2011 Resolved
1710; Oil Record Book has not been filled out properly. Since November 2009, part III has not been filled out during bunkering. Codes 11.1, 11.2 and 11.3 have not been used correctly and new requirements under MEPC 187 (59) were not on board. Code "D" item number 13, 13 and 15.3 have not been filled in properly, 70 A/B.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 25 February 2011 Resolved
1705; Local contact number for SOPEP Appendix II re not being filled in, 70 A/B.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 25 February 2011 Resolved
2199; Incinerator re-factory needs repaired and waste oil tank temperature control and thermostat are patched with fiberglass, 70 A/B.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 25 February 2011 Resolved
2120; Food mixed with plastics was found in containers at the final collection point prior to disposal into the sea. Plastic covers over bunker stations are also falling apart allowing plastic items to go into the sea. Mixed items of all type are being incinerated. Some items may contain plastic and metal items, which can cause damage to the incinerator, 70 A/B.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 25 February 2011 Resolved
0799; All photo luminescent placards in the engine room and other areas throughout the vessel are non-operational. They will not stay lighted very long, 70 A/B.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Fire Fighting › Means of Escape › Blocked
Issued 25 February 2011 Resolved
0700; Galley door entrance / exit is being blocked by table and no longer meets fire plan, 70 A/B.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 March 2011
Resolved 26 February 2011
Resolution: Addressed by the attending Classification Society Representative.
Navigation › Piloting/Steering › Gyro Compass
Issued 17 December 2010 Resolved
Vessel must have a working Gyro compass. Vessels Gyro compass is inoperable. Vessel required to send in Tech report attesting to the repair and proper operation of the vessels Gyro compass. To be verified by the Coast Guard. Site: 33CFR164.35(d)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2011
Resolution: Vessel submitted Tech report attesting to the proper operation of the vessels Gyro Compass. Technician repaired and tested the vessels Gyro Compass and repeaters, all found satisfactorily.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 30 October 2006 Resolved
Freezer door latch found to be inoperable.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 8 January 2007
Resolution: Witnessed proper repairs made to freezer door latches.
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 30 October 2006 Resolved
Shower in hospital space found to be inoperable.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 8 January 2007
Resolution: Witnessed proper repairs made to shower.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 October 2006 Resolved
Deck flooring/tile on main deck inside hallway was deteriorated and warped causing a tripping/falling hazard.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 8 January 2007
Resolution: Witnessed proper repairs made to vessel''s deck.
Engineering › Steering Gear System › Motor
Issued 26 January 2006 Resolved
Steering leaks from upper bearing seal into rudder void. Approx. 1 Liter per day. Class to attend and survey steering equipment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2006
Resolution: Fax recived Class Report attesting to leak in steering gear being small and arrangements remain efficient meantime. Suitalbe condition of class imposed for seals to be renewed in upcoming dry dock in March 2006.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 October 2005 Resolved
Heat lamps installed over the hydraulic storage tank for the steering gear and over the emergency fire pump. Ship to have class approve the installation of all heat lamps.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 26 October 2005
Resolution: Class Report recieved.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 October 2005 Resolved
Sea water cooling to auxiliary generator has a hole with clamp and rubber patch. Hole is located in pipe lower level engine room, above shaft in way of frame 15. Repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 26 October 2005
Resolution: Class Report recieved.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 14 October 2005 Resolved
Fresh water cooler for main engine piston has soft patch on the end bell, lower drain. Make repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 26 October 2005
Resolution: Class Report recieved.
Engineering › Compressed Air System (start air) › Piping
Issued 14 October 2005 Resolved
Sea water inlet for the #1 high pressure staring air compressor has a rubber patch. Make repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 26 October 2005
Resolution: Class Report recieved.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 October 2005 Resolved
During the review of the Oil Record Book (ORB) entries have been made of the Oil Water Separator use going through the 100 PPM. ORB entry should be D15.2 versus D 15.1. Vessel is still using old type ORB. Vessel to have ORB #88252 reviewed by Flag to ensure proper entries are being made.
Action required: 705 - Other - as specified
Due 9 November 2005
Resolved 10 November 2005
Resolution: New oil record book issued to vessel via ships agent while CG inspectors onboard, no entries made at this time.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 14 October 2005 Resolved
Fireman suits are holed and have the foil face flaking off. Replace the suits next US port after going foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2005
Resolution: Class Report received.
Operations/Management › Drills/Instruction › Fire
Issued 14 October 2005 Resolved
Port State Control Officer witnessed two (2) fire drills that were unsatisfactory. A third drill was conducted which was satisfactory.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 14 October 2005
Resolution: A third drill was conducted which was satisfactory.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 14 October 2005 Resolved
With the findings of items #2, #3, #4 and #6, Master is to provide proof that non conformity report has been sent to the Designated Person Ashore (DPA) and that the DPA has provide the ship with his response.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2005
Resolved 15 October 2005
Resolution: Received proof that nonconformity report has been sent and return comments from DPA provide.
Navigation › Piloting/Steering
Issued 21 April 2004 Resolved
Gyro Compass is inoperable. 33CFR 164.35d (.11r) LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2004
Resolved 29 April 2004
Resolution: RECEIVED DOCUMENTATION VIA FAX THAT THE GYRO COMPASS WAS REPAIRED BY MACKAY COMMUNICATIONS. REPAIRS MADE ON 4/20/2004.
Deck/Cargo › Mooring/Anchoring
Issued 16 January 2004 Resolved
Vessel wishes to enter port on Jan 17, 2004 with both anchors frozen and inoperable. Prior to departing port vessel must provide a written statement from the master verifying that the vessel is fit for route. LEGACY COMPONENT DESC: Anchor
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2004
Resolution: Statement recieved from master showing vessel fit for route.
Construction/Loadline › Hull
Issued 24 March 2003 Resolved
Vessel grounded due to outgoing tide while moored and discharging cargo. Condition of class issued 23 March 2003 the vessel is required to conduct an underwater damage survey prior to next U.S. port to the satisfaction of attending class surveyor.(condition of class on file at SAVMS) LEGACY COMPONENT DESC: Bottom Plating
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2003
Resolution: REC''D PROPER DOCUMENTATION
Electrical › Lighting (service)
Issued 3 October 2002 Resolved
Numerous passageway and berthing flourescent light fixtures missing covers. Provide ACTNY fax copy of order invoice. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 17 October 2002
Resolved 13 November 2002
Resolution: Received fax copy of invoice and letter from master stating all lights have been repaired as of 08 NOV 2002.
Lifesaving › Launching Appliances › Hand Gear
Issued 3 October 2002 Resolved
Forward griping blocks partially seized and difficult to haul boat in to ship. Crew fixed on the spot.
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 3 October 2002
Resolution: Crew fixed on the spot.
Engineering › Compressed Air System (start air) › Compressor
Issued 3 October 2002 Resolved
Generator emergency air compressor inop. Compressor would turn over momentarilly but not start.
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 3 October 2002
Resolution: Crew fixed on the spot.
Fire Fighting › Fire Main › Condition
Issued 5 April 2002 Resolved
HUGE CRACK IN THE FIREMAIN NEAR THE #4 CARGO HOLD. RESULT IS LOSS OF WATER PRESSURE FOR FIRE FIGHTING CAPABILITIES.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2002
Resolved 6 April 2002
Resolution: CREW CUT AND WELDED IN A NEW PIECEOF PIPING. SYTEM TESTED FOR LEAKS AND PROPER WATER PRESSURE, ALL SAT.
Lifesaving
Issued 3 October 2001 Resolved
Several required lifeboat items missing from both lifeboats (Port-seat markings,rations,survival manual,radar reflector,flashlight w/ extra batteries,seasickness bags,3 tin openers. Starboard-seat markings,survival manual,seasickness bags,radar reflector,3 tin openers).
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Navigation
Issued 8 September 1998 Resolved
MANUVERING FACT SHEET NEEDS EFFICTIVE RANGE FOR BOW THRUSTER AND PROPER WARNING ADDED AS PER 33CFR164.35
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 9 May 1998 Resolved
REPLACE 61 RATIONS IN PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Lifesaving
Issued 9 September 1996 Resolved
PROVIDE AN OPERATIONAL EPIRB AS REQUIRED BY SOLAS 74 IV/7.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Lifesaving
Issued 13 May 1996 Resolved
Properly install weak links on all inflatable liferafts IAW SOLAS III, reg 38.6.2.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 13 May 1996 Resolved
Remove all paint and other flammables from the starboard side locker. Thiscompartment is not dedicated as a paint locker. All flammables must be stowed in the Port side paint locker.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Fire Fighting
Issued 13 May 1996 Resolved
Make repairs to the fire main piping where there are leaks around the couplings. Leaks were observed in way of cargo hatches #3 and #4 on the starboard side main deck. Lloyds surveyor onboard approved repairs and tested fire main satisfactory.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 1 September 1995 Resolved
Replace all hoses for hand bilge pumps on both the port and starboard lifeboats. Both the suction and discharge hoses were wasted.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Lifesaving
Issued 1 September 1995 Resolved
Repair/renew wasted port openings for provision lockers in both lifeboats. Vessel was unable to open the provision lockers. In addition, the wing nuts were wasted making it impossible to secure the provision lockers for sea.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Documentation
Issued 1 September 1995 Resolved
The M/V GEORGIA S was in violation of 33 CFR 155.720 when their oil transfer procedures were incomplete. The items missing were list of products transferred, means of communication, and procedures for emptying containment.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Documentation
Issued 10 October 1990 Resolved
A vio of 33CFR155.820 in that the vsl did not have a written record of the date and results of the most recent test of the oil transfer system as req by 33CFR156.170._x001C_ _x001C_
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Navigation
Issued 13 December 1988 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE STEERING GEAR BLOCK DIAGRAM REQ. BY 33 CFR 164.35(K) WAS NOT POSTED ON THE BRIDGE.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Navigation
Issued 13 December 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Navigation
Issued 12 April 1987 Resolved
A VIO OF 33CFR164.11(R) IN THAT THE SECONDARY RADAR REQ BY 33CFR164.37(A) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/W IN THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 12 April 1987
Resolved 12 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.