Records from 1996 to 2006. Most recent: operational control imposed, 15 September 2006.
Inspection history · 20
15 September 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2778967
15 September 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2778973
14 September 2006
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2778018
9 June 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2674690
6 June 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2672217
22 March 2006
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2607348
5 March 2006
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS I Exam · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2596106
5 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2596170
4 June 2004
MTSA/ISPS Verification · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2088916
1 June 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2085270
19 March 2004
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2027527
10 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2024443
5 March 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2019157
7 April 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1769726
17 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 292994
8 May 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289469
1 April 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 426965
29 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 416519
24 September 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395708
8 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392996
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 September 2006
Resolved
During inspection, conducted investigation of forward port side bulwark and gaurdrail damage that was a result of a collision with another vessel while attempting to moore. Port side bulwark and guardrail was found badly damaged and not fit for service. Vessel to have class survey damage and sugest next course of action.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2006
Resolved 21 September 2006
Resolution: Obtained CLASS repport prior to departure.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 14 September 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2006
Resolved 21 September 2006
Resolution: Obatined CLASS report departure.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 June 2006
Resolved
Sea water pipe to condenser cascade tank has 05 bracket patches that are dripping onto switchbox for F/W #1 nozzle cooling pump and control panel for water condenser.
CITE: SOLAS 74 Part C Reg.27(i)1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 September 2006
Resolution: CG attested to proper working order of seawater pipe.
Construction/Loadline › Structures › Door
Issued 9 June 2006
Resolved
Main deck Starboard foward bulkhead accomadation watertight door is not lined up correctively withknife edge and is nothold its seal adequately.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 September 2006
Resolution: CG observed main deck Starboarfd forward bulkhead accomadation watertight door properly aligned.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 5 March 2006
Resolved
Five out of the six self contained breathing apparatus are empty. Recharge all self contained breathing apparatus to the satisfaction of the flag state administration prior to departing the port of NY / NJ.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2006
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 5 March 2006
Resolved
The OWS bilge monitor is not installed IAW the manufactures instructions and is not included on the OWS prints. IAW the manufactures instructions the monitor sampling pipe should discharge directly to the bilge not back to the suction side of the pump. Make repairs and amend prints to the satisfaction of the Flag Administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2006
Resolution: Received class report from GL satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 5 March 2006
Resolved
The ships incinerator has a fuel oil leak at the injection nozzle. Repair the leak to the satisfaction of the Flag Administration prior to using the incinerator.
Due 19 March 2006
Resolved 22 March 2006
Resolution: Received class report from GL satisfying requirement.
Navigation › Piloting/Steering › Gyro Compass
Issued 19 March 2004
Resolved
Vessel had inoperable gyrocompass.
Action required: 705 - Other - as specified
Due 19 March 2004
Resolved 19 March 2004
Resolution: Received technician report attesting to satisfactory operation of vessel''s gyro compass.
Navigation › Piloting/Steering
Issued 5 March 2004
Resolved
06 MAR 04 agent request LOD for M/V CLIO to enter port of Savannah. LOD is granted.
07 MAR 04 tech report shows GYRO can not be repaired until 9 MAR 04. Agent request LOD for vessel to depart and repair GYRO in New Orleans. LEGACY COMPONENT DESC: Gyro Compass
Condition: Placed in Improper Service
Due 7 March 2004
Resolved 1 June 2004
Resolution: Received tech report from [name withheld] satisfying requirement.
Lifesaving
Issued 8 May 2001
Resolved
24 Food rations from lifeboats missing vacuum seal in violation of SOLAS 74/78 Chapter III Regulation 41-8.12.
Condition: Unknown
Due 8 May 2001
Resolved 10 May 2001
Deck/Cargo
Issued 8 May 2001
Resolved
Repair both chain wash valves on focsle in viloation of ILLC.
Condition: Unknown
Due 16 May 2001
Resolved 17 May 2001
Deck/Cargo
Issued 8 May 2001
Resolved
Repair firemain valve on portside aft main deck in violation of Solas 74/78Chapter II-1 Regulation 21.2.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Navigation
Issued 8 May 2001
Resolved
Repair solenoid valve body for #1 steering pump in viloation of Solas 74/78Chapter II-I Regulation 26.1.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Deck/Cargo
Issued 8 May 2001
Resolved
#1 Cargo hold Entrance portside foward is locked and blocked with line in violation of ILO-147.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Engineering
Issued 8 May 2001
Resolved
Flange leaks on seawater pump to evaporator in violation of Solas 74/78 Chapter II-I Regulation 26.1.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Engineering
Issued 1 April 1999
Resolved
Correct freshwater leak from #5 cylander on #3 ssdg._x001C_ _x001C_ Solas 74(A) II-2/26.1
Condition: Unknown
Due 8 May 2001
Resolved 10 May 2001
Fire Fighting
Issued 1 April 1999
Resolved
Provide new fire hose and nozzle for fire station located port side at stackhouse vent._x001C_ SOLAS 74(A) II-2/21
Condition: Unknown
Due 1 April 1999
Resolved 3 April 1999
Lifesaving
Issued 1 April 1999
Resolved
Class to attest to proper operation of port and stbd deadman brake systems._x001C_ SOLAS 74 (A) III-48.10.2
Condition: Unknown
Due 1 April 1999
Resolved 3 April 1999
Lifesaving
Issued 1 April 1999
Resolved
Class to attest to proper operation of port and stbd single point release_x001C_ on lifeboats._x001C_ SOLAS 74(A) III 19.2
Condition: Unknown
Due 1 April 1999
Resolved 3 April 1999
Lifesaving
Issued 1 April 1999
Resolved
Replace lifeboat drinking water (2X120 liters)_x001C_ SOLAS 74(A) III/41.8
Condition: Unknown
Due 1 April 1999
Resolved 3 April 1999
Lifesaving
Issued 1 April 1999
Resolved
Replace 8 unusable lifejackets._x001C_ _x001C_ SOLAS 74(A) III 19.2
Condition: Unknown
Due 1 April 1999
Resolved 3 April 1999
Accommodation/Occupational Safety
Issued 8 July 1996
Resolved
FORWARD LADDER LEADING TO FOSCLE ON STARBOARD SIDE WASTED. (ILO-147)
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996