MAURY USCG vessel records
← All vessels

USNS SHUGHART

USNS SHUGHART is a 1980 freight ship. The Coast Guard has recorded 22 inspections since 2016, most recently in February 2022, along with 37 deficiencies — 1 with no resolution recorded — and 2 operational controls, 1 with no removal date recorded.

Records from 2016 to 2022. Most recent: inspection, 23 February 2022.

Built
1980
Last inspected
23 February 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 February 2022
…with no type recorded2
Operational controls 1 with no removal date recorded
Years with a record 6 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7825394
431934
Flag
UNITED STATES
Maury page id
psix-431934

Documentation record

Tonnage as PSIX records it25900 - Dead Weight, Ton
59458 - Displacement, Ton
59387 - Convention (Subpart B), Gross Ton
18477 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

23 February 2022 Special Consideration · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7400482
16 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7141199
23 September 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7063877
15 September 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7060777
29 August 2020 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7046427
21 July 2020 COI Inspection · Ballast Water Examination · ACP COI Oversight · Re-Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6984813
24 June 2020 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6985629
20 December 2018 ACP COI Oversight · Periodic Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6601074
6 September 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6533633
23 July 2018 ACP Additional Oversight – Risk Assessment · Special · Administrative Inspection · Permit to Proceed
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6488334
29 January 2018 Permit to Proceed · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346303
20 November 2017 ACP Additional Oversight – Risk Assessment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6314391
19 October 2017 ACP Additional Oversight – Risk Assessment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293572
19 October 2017 ISM SMC Audit
Administrative · Commandant (CG-5P-TI) · Activity 6307360
10 September 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6264681
26 July 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6216324
8 June 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6188850
2 February 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6081845
18 August 2016 Deficiency Check · ISM Oversight · Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5974050
2 April 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5845805
24 March 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5839876
15 March 2016 Administrative Inspection · Internal Structural Exam · Drydock Exam · ACP COI Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5833754

Deficiency record · 37

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. #1 life boat doors would not operate effectively and need to be freed. Complete repairs to the satisfaction of the RO prior to departing anchorage. 74 SOLAS (14) I/11(a)
Action required: 705 - Other - as specified
Resolved 21 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. # 3 life boat steering would not operate properly. Complete repairs to the satisfaction of the RO. 74 SOLAS (14) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2020
Resolved 21 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. #1 generator caught fire due fuel leak from fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 September 2020
Resolution: ABS accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 July 2020 Resolved
One of the engine rooms ventilation stack dampers did not operate. 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2020
Resolved 22 July 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 July 2020 Resolved
The steering sytem port forward hydaulic atuator flex hose needs replaced. 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2020
Resolved 22 July 2020
Resolution: 4374344
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 21 July 2020 Resolved
Gyro repeaters not reflecting heading incaccurate by 20 plus degrees 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 21 July 2020 Resolved
Incinerator listed on IOPP but is inoperable. 74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2020 Resolved
2 saltwater cooling pumps are missing motors. 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 July 2020 Resolved
#2 generator has excessiv e oil leaking from the turbos oil drain line 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 21 July 2020 Resolved
Oily water separator content meter does not have means for testing the 15ppm alarm 74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 21 July 2020 Resolved
Crew not sounding all IOPP for A 3.1 tanks as required. 74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
09 - Working and Living Conditions › 091 - Living Conditions › Laundry
Issued 21 July 2020 Resolved
dryer #3 is missing panel causing electrical hazard. 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2020 Resolved
Portable fire extinguisher not serviced annually on 03 deck new house laundry room 74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 July 2020 Resolved
found switch cover missing located at door outside incinerator space. 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2020 Resolved
Found 11 extinguishing brackets missing spares, verify quantity of spares on ship are adequate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 July 2020 Resolved
Two hydro static release installed upside down on port side helo deck 74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 July 2020 Resolved
On 03 deck located at engine room casing door, handle broke and needs to be replaced 74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 20 November 2017 No resolution recorded
History substandard condition of both vessels, and lack of plans or progress in correcting deficiencies and conditions of class. Removed COI.
Action required: 705 - Other - as specified
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 July 2017 Resolved
PROVIDE PROPER OPERATION OF THE FIRE DETECTION SYSTEM THROUGHOUT THE VESSEL, IDENTIFY ROOT CAUSE OF DETECTION FAULTS.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017. See MISLE documents for report.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 26 July 2017 Resolved
The Lube oil sounding tube on the Port side "A" deck behind entrance to the steering gear room is missing cap and self closing valve.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 July 2017 Resolved
Several I-Lights Throughout the ship are inoperative (Steering gear rm, Escape trunks, Thruster rm, etc)
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Self-contained Breathing Apparatus › Quantity
Issued 26 July 2017 Resolved
Several EEBD's have broken seals and must be replaced (Upper eng rm store room Escape trunk, Steering gear rm)
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2017 Resolved
#11 Aft Deck Machinery MRG pump cables are exposed with circuit energized.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 26 July 2017 Resolved
Gagged Lube oil sight glass valves on the steering gear and MDE Cylinder oil service tanks.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 26 July 2017 Resolved
The Forward A1 Ladder well has a ventilation isolation contactor exposed and missing its cover.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Fire Hoses › Condition
Issued 26 July 2017 Resolved
Fire station 3-187-2 missing Fire nozzle, 2-186-2 all hoses are disconnected, 7-200-1 missing hoses + nozzles + spanner wrench, Stbd side wx deck lifeboat fire station missing nozzle and the majority of fire hose nozzles throughout the vessel are dry rotted.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 26 July 2017 Resolved
Engine Room store room engineers assistance alarm is missing, Escape trunk door does not close, E-lighting is out and Debris is scattered throughout the entire escape route.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 July 2017 Resolved
Emergency escape vestibule A-127-2 is missing the latch handle and self closing assembly
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 26 July 2017 Resolved
The local steering gear rudder angle indicator cannot be seen from emer steering operating station.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 July 2017 Resolved
Class 3 Hydraulic WTD 2-114-2 gasket material needs to be renewed
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2017 Resolved
Bosn store room A-365-0 has dead end wires connected to a surge protector
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Fire Hydrants › Location/Position
Issued 26 July 2017 Resolved
Fire station 3-211-1 has double stacked plug valves with the discharge facing up. Plug direction should face horizontal.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Communications › Public Address System › Broadcast Location
Issued 26 July 2017 Resolved
Vessels PA System is inoperable.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 26 July 2017 Resolved
Steering gear alarms on the bridge are inoperable.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 26 July 2017 Resolved
AUTOMATED TEST PROCEDURES FOR FIRE DETECTION SYSTEM NEEDS REVISION TO INCLUDE PROCEDURES FOR ADDRESSING FAULTS.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 July 2016 Resolved
Vessel Authorized Classification Society (ABS) has dropped the ACCU Note due to automation issues in the engine room. When vessel is in an operational status or underway the vessels engine room must be fully manned until the ACCU Note is reinstated. Provide a copy of the Class Certificate to USCG to show that the ACCU Noted as be added.
Action required: 705 - Other - as specified
Resolved 14 April 2017
Resolution: This ISM ABS non conformity was corrected for the ACCU notation and mannning requirements. #2SSDG Diesel COntrol Cabinet -Parts installed tested satisfactory.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 July 2016 Resolved
Excessive oil (HFO) on cargo/vehicle Hold #4E and aft end of #4D, approx 200 gallons. Vessel is to provide proof that the HFO has been cleaned in the areas noted and from all associated piping. USCG to examine area prior to departure. Rose boxes need to be reexamined upon return to New Orleans.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 30 August 2016
Resolution: Def corrected. Received pictures from Port engineer showing satisfactory removal and clean up of rose boxes.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.