Records from 1996 to 2022. Most recent: inspection, 23 February 2022.
Inspection history · 119
23 February 2022
Special Consideration · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7400482
16 February 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7141199
23 September 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7063877
15 September 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7060777
29 August 2020
Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7046427
21 July 2020
COI Inspection · Ballast Water Examination · ACP COI Oversight · Re-Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6984813
24 June 2020
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6985629
20 December 2018
ACP COI Oversight · Periodic Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6601074
6 September 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6533633
23 July 2018
ACP Additional Oversight – Risk Assessment · Special · Administrative Inspection · Permit to Proceed
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6488334
29 January 2018
Permit to Proceed · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346303
20 November 2017
ACP Additional Oversight – Risk Assessment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6314391
19 October 2017
ACP Additional Oversight – Risk Assessment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293572
19 October 2017
ISM SMC Audit
Administrative · Commandant (CG-5P-TI) · Activity 6307360
10 September 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6264681
26 July 2017
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6216324
8 June 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6188850
2 February 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6081845
18 August 2016
Deficiency Check · ISM Oversight · Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5974050
2 April 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5845805
24 March 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5839876
15 March 2016
Administrative Inspection · Internal Structural Exam · Drydock Exam · ACP COI Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5833754
27 June 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4370002
11 June 2012
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4330114
4 January 2011
In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3922384
28 December 2010
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3917439
10 April 2009
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3449893
3 April 2008
ACP Annual Oversight
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176621
26 February 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2892668
19 October 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2803805
15 September 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2778967
15 September 2006
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2779221
16 August 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2750015
13 June 2006
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2677802
31 May 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2666247
15 February 2006
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2587337
25 October 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2531716
25 October 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2538385
25 July 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2440733
15 July 2005
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2427902
8 May 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2516660
6 May 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2352799
19 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2337746
7 April 2005
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2329255
14 March 2005
Ballast Water Examination · MTSA Verification · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2283467
20 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104833
1 June 2004
Examination of Repairs · Damage Survey · Permit to Proceed
Physical examination · Activities Europe · Activity 2125707
1 May 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2065118
17 March 2004
Permit to Proceed
Administrative · Activities Europe · Activity 2028825
5 March 2004
Type not recorded
No type recorded · Activities Europe · Activity 2020386
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997514
11 September 2003
Periodic Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1901668
28 August 2003
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1881156
1 August 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1889769
29 April 2003
Type not recorded
No type recorded · Activities Europe · Activity 1798730
21 April 2003
Type not recorded
No type recorded · Activities Europe · Activity 1798724
7 April 2003
Type not recorded
No type recorded · Activities Europe · Activity 1777568
24 July 2002
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1651899
26 February 2002
Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1489363
7 February 2002
Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1484741
21 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 79495
23 July 2001
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1444614
17 May 2001
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1064468
15 May 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1063389
26 March 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 745568
16 March 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1373383
27 February 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1393622
5 February 2001
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1058406
12 January 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1061050
10 January 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 102854
7 September 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1429390
13 July 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1052005
21 June 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1050915
23 May 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 818135
17 May 2000
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1376175
22 February 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 477039
10 May 1999
Re-Inspection
Physical examination · Activities Europe · Activity 1427655
8 December 1998
Type not recorded
No type recorded · Activities Europe · Activity 79150
25 August 1998
Deficiency Check
Physical examination · Activities Europe · Activity 796839
13 July 1998
Deficiency Check
Physical examination · Activities Europe · Activity 794551
22 May 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1126449
3 May 1998
COI Inspection
Physical examination · Activities Europe · Activity 1368729
24 March 1998
Type not recorded
No type recorded · Activities Europe · Activity 79243
11 February 1998
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1111283
23 January 1998
Type not recorded
No type recorded · Activities Europe · Activity 25303
2 August 1997
Type not recorded
No type recorded · Activities Europe · Activity 232276
26 June 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 444732
17 June 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 84358
17 June 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1407918
16 June 1997
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 777200
11 June 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 773839
6 June 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 773671
22 May 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1460958
17 May 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 105394
16 May 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1093408
16 May 1997
Examination of Repairs · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1100165
15 March 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1095540
8 March 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 135972
14 February 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1105746
20 January 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1099468
5 January 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1097420
20 December 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1093758
14 December 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1092597
6 December 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1091654
3 December 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1186618
19 November 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 870282
8 November 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1171722
1 November 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 857258
10 October 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 841789
20 September 1996
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1134543
30 August 1996
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 937561
13 August 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 124179
2 August 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2838
23 July 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1087645
2 May 1996
Hull Examination · Reflagging & Initial Certification · Initial Certification · Construction Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1421165
26 February 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 25960
24 February 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 58949
23 February 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 38707
5 February 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 118452
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. #1 life boat doors would not operate effectively and need to be freed. Complete repairs to the satisfaction of the RO prior to departing anchorage.
74 SOLAS (14) I/11(a)
Action required: 705 - Other - as specified
Resolved 21 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. # 3 life boat steering would not operate properly. Complete repairs to the satisfaction of the RO.
74 SOLAS (14) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2020
Resolved 21 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. #1 generator caught fire due fuel leak from fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 September 2020
Resolution: ABS accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 July 2020
Resolved
One of the engine rooms ventilation stack dampers did not operate.
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2020
Resolved 22 July 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 July 2020
Resolved
The steering sytem port forward hydaulic atuator flex hose needs replaced.
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2020
Resolved 22 July 2020
Resolution: 4374344
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 21 July 2020
Resolved
Gyro repeaters not reflecting heading incaccurate by 20 plus degrees
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 21 July 2020
Resolved
Incinerator listed on IOPP but is inoperable.
74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2020
Resolved
2 saltwater cooling pumps are missing motors.
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 July 2020
Resolved
#2 generator has excessiv e oil leaking from the turbos oil drain line
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 21 July 2020
Resolved
Oily water separator content meter does not have means for testing the 15ppm alarm
74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 21 July 2020
Resolved
Crew not sounding all IOPP for A 3.1 tanks as required.
74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
09 - Working and Living Conditions › 091 - Living Conditions › Laundry
Issued 21 July 2020
Resolved
dryer #3 is missing panel causing electrical hazard.
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2020
Resolved
Portable fire extinguisher not serviced annually on 03 deck new house laundry room
74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 July 2020
Resolved
found switch cover missing located at door outside incinerator space.
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2020
Resolved
Found 11 extinguishing brackets missing spares, verify quantity of spares on ship are adequate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 July 2020
Resolved
Two hydro static release installed upside down on port side helo deck
74 Solas I Reg 11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 July 2020
Resolved
On 03 deck located at engine room casing door, handle broke and needs to be replaced
74 Solas I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 27 July 2020
Resolution: 4374344
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 20 November 2017
No resolution recorded
History substandard condition of both vessels, and lack of plans or progress in correcting deficiencies and conditions of class. Removed COI.
Action required: 705 - Other - as specified
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 July 2017
Resolved
PROVIDE PROPER OPERATION OF THE FIRE DETECTION SYSTEM THROUGHOUT THE VESSEL, IDENTIFY ROOT CAUSE OF DETECTION FAULTS.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017. See MISLE documents for report.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 26 July 2017
Resolved
The Lube oil sounding tube on the Port side "A" deck behind entrance to the steering gear room is missing cap and self closing valve.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 July 2017
Resolved
Several I-Lights Throughout the ship are inoperative (Steering gear rm, Escape trunks, Thruster rm, etc)
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Self-contained Breathing Apparatus › Quantity
Issued 26 July 2017
Resolved
Several EEBD's have broken seals and must be replaced (Upper eng rm store room Escape trunk, Steering gear rm)
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2017
Resolved
#11 Aft Deck Machinery MRG pump cables are exposed with circuit energized.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 26 July 2017
Resolved
Gagged Lube oil sight glass valves on the steering gear and MDE Cylinder oil service tanks.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 26 July 2017
Resolved
The Forward A1 Ladder well has a ventilation isolation contactor exposed and missing its cover.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Fire Hoses › Condition
Issued 26 July 2017
Resolved
Fire station 3-187-2 missing Fire nozzle, 2-186-2 all hoses are disconnected, 7-200-1 missing hoses + nozzles + spanner wrench, Stbd side wx deck lifeboat fire station missing nozzle and the majority of fire hose nozzles throughout the vessel are dry rotted.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 26 July 2017
Resolved
Engine Room store room engineers assistance alarm is missing, Escape trunk door does not close, E-lighting is out and Debris is scattered throughout the entire escape route.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 July 2017
Resolved
Emergency escape vestibule A-127-2 is missing the latch handle and self closing assembly
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 26 July 2017
Resolved
The local steering gear rudder angle indicator cannot be seen from emer steering operating station.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 July 2017
Resolved
Class 3 Hydraulic WTD 2-114-2 gasket material needs to be renewed
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2017
Resolved
Bosn store room A-365-0 has dead end wires connected to a surge protector
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Fire Fighting › Fire Hydrants › Location/Position
Issued 26 July 2017
Resolved
Fire station 3-211-1 has double stacked plug valves with the discharge facing up. Plug direction should face horizontal.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Communications › Public Address System › Broadcast Location
Issued 26 July 2017
Resolved
Vessels PA System is inoperable.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 26 July 2017
Resolved
Steering gear alarms on the bridge are inoperable.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 26 July 2017
Resolved
AUTOMATED TEST PROCEDURES FOR FIRE DETECTION SYSTEM NEEDS REVISION TO INCLUDE PROCEDURES FOR ADDRESSING FAULTS.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: ABS Class Surveyor has included this deficiency as a Condition of Class, report # NO3371038 dated 11AUG2017.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 July 2016
Resolved
Vessel Authorized Classification Society (ABS) has dropped the ACCU Note due to automation issues in the engine room. When vessel is in an operational status or underway the vessels engine room must be fully manned until the ACCU Note is reinstated. Provide a copy of the Class Certificate to USCG to show that the ACCU Noted as be added.
Action required: 705 - Other - as specified
Resolved 14 April 2017
Resolution: This ISM ABS non conformity was corrected for the ACCU notation and mannning requirements. #2SSDG Diesel COntrol Cabinet -Parts installed tested satisfactory.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 July 2016
Resolved
Excessive oil (HFO) on cargo/vehicle Hold #4E and aft end of #4D, approx 200 gallons. Vessel is to provide proof that the HFO has been cleaned in the areas noted and from all associated piping. USCG to examine area prior to departure. Rose boxes need to be reexamined upon return to New Orleans.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 30 August 2016
Resolution: Def corrected. Received pictures from Port engineer showing satisfactory removal and clean up of rose boxes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 June 2012
Resolved
Properly terminate dead end cable from previous battery charger to rescue boat
Action required: 705 - Other - as specified
Resolved 24 July 2012
Resolution: Received conformation from ABS that deficiency has been corrected.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 11 June 2012
Resolved
Provide prop guard and report showing proper operation of engine (no cooling water through tattle tale)
Action required: 705 - Other - as specified
Resolved 24 July 2012
Resolution: Received conformation from ABS that deficiency has been corrected.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 11 June 2012
Resolved
Provide report showing repair and proper operation of fire detection system - showing ground in cargo hold 3
Action required: 705 - Other - as specified
Resolved 3 October 2012
Resolution: Received conformation from ABS that deficiency has been corrected.
Communications › Radio Communications › EPIRB
Issued 11 June 2012
Resolved
Provide new hydrostatic release and NOAA registration for EPIRB
Action required: 705 - Other - as specified
Resolved 24 July 2012
Resolution: Received conformation from ABS that deficiency has been corrected.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 April 2008
Resolved
3 cm rdr is inop.
Action required: 705 - Other - as specified
Resolved 1 May 2008
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 13 June 2006
Resolved
Make permanent repairs to bilge piping in E/R. Repair soft patch on pipe.
Action required: 705 - Other - as specified
Due 13 July 2006
Resolved 7 July 2006
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 13 June 2006
Resolved
Provide Service report and written confirmation of proper installation for all life rafts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2006
Resolution: Installation letter sent 15 June 2006, verified installation on 7 July 2006.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 June 2006
Resolved
Provide service report for all fixed fire extinguishing systems
Due 13 July 2006
Resolved 7 July 2006
Resolution: completed
Fire Fighting › Combustible Materials › Linings
Issued 13 June 2006
Resolved
Provide fire blanket for galley (missing from storage container).
Due 13 July 2006
Resolved 7 July 2006
Resolution: corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 June 2006
Resolved
Replace expired batteries in ring buoy lights (lights operational)
Due 13 July 2006
Resolved 7 July 2006
Resolution: corrected
Lifesaving › Inflatable Liferafts › Container Marking
Issued 13 June 2006
Resolved
Provide legible life raft instructions on fwd life raft.
Due 13 July 2006
Resolved 7 July 2006
Resolution: corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 13 June 2006
Resolved
Provide mallet to break glass on hose reel activation station 01-262-1
Condition: Improper Installation
Due 13 July 2006
Resolved 7 July 2006
Resolution: installed
Communications › Alarms/Indicators › General Alarm
Issued 13 June 2006
Resolved
Prove proper operation of general alarms outside of paint locker & fwd foam room
Due 13 July 2006
Resolved 7 July 2006
Resolution: corrected
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 13 June 2006
Resolved
Prove proper operation of alarms for ramp doors on weather deck and A deck
Due 13 July 2006
Resolved 7 July 2006
Resolution: corrected
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 June 2006
Resolved
Prove proper operation of battle lanterns and flashlights in repair lockers
Due 13 July 2006
Resolved 7 July 2006
Resolution: corrected
Communications › Radio Communications › Satellite Communications Capability
Issued 25 July 2005
Resolved
The monitor on the Simple Telex Over Radio (SITOR) is inoperable. Vessel is restricted to sea area A1 until SITOR monitor is repaired.
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 25 October 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 7 April 2005
Resolved
Prior to vessel sailing, but no later than next dry dock availability (30 Sep 05), make modifications to the fixed CO2 fire fighting systems to match approved drawings dated March 17, 2005 by the Coast Guard Marine Safety Center. The installation, workmanship, and testing shall be to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 25 October 2005
Construction/Loadline › Markings › Load Line Mark
Issued 14 March 2005
Resolved
Repaint load line and load draft marks with contrasting color, due next dry-dock.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 19 September 2005
Fire Fighting › Fixed Fire Detection System › Approval
Issued 14 March 2005
Resolved
Provide approval of the modifications made to the fire detection system
Action required: 705 - Other - as specified
Due 15 June 2005
Resolved 30 June 2005
Resolution: MSC approved letter reviewed regarding modifications made to the fire detection system. Deficiency cleared
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 14 March 2005
Resolved
Prove proper operation of cargo hold fans prior to loading cargo.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2005
Resolved 6 May 2005
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 14 March 2005
Resolved
Submit for approval for the boiler automation procedures.
Action required: 705 - Other - as specified
Due 15 June 2005
Resolved 12 May 2005
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 14 March 2005
Resolved
Make all pressure vessels available for inspection per 46 CFR 61.10 at the next drydocking or prior to vessel operation which ever comes first.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 19 September 2005
Engineering › Steam Boiler (auxiliary/waste heat) › Firebox Brick
Issued 14 March 2005
Resolved
Conduct fireside & waterside exams on aux boilers at next drydock or prior to operating vessel which ever comes first.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 19 September 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 February 2005
Resolved
Amend and submit for approval for the fire control plan
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 25 October 2005
Engineering › Pressure Vessel › Marking and Stamping
Issued 1 February 2005
Resolved
Provide documentation to prove all PVs are approved.
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 6 May 2005
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 1 February 2005
Resolved
Relace bearing on the aux generator and show proper operation.
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 17 March 2005
Resolution: Fixed.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2005
Resolved
Repair light fixture aft of the focale port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 17 March 2005
Resolution: Fixed.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 1 February 2005
Resolved
Repair any hydraulic leaks and clean windless machinery room.
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 6 May 2005
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 June 2004
Resolved
Prove proper operation of all remote operated F/O shut-off valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2004
Resolution: Verified item cleared via e-mail from vessel Master. T.G. [name withheld], LT
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2004
Resolved
Ensure all electrical wiring runs have approved fire stop installed where required.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2004
Resolution: Cleared via e-mail from Master. T. G. [name withheld], [name withheld]
Electrical › Lighting (service) › Lighting Fixture
Issued 1 June 2004
Resolved
Prove proper operation of stbd navigation light and mast head light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2004
Resolution: Cleared via e-mail from master. T.G. [name withheld], [name withheld]
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 1 June 2004
Resolved
Prove proper operation of doppler speed log feeding ARPAs (fwd).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2004
Resolution: Cleared via e-mail from Master. T. G. [name withheld], [name withheld]
Electrical › Electric Generation Source (service) › Power Requirement
Issued 1 June 2004
Resolved
Prove proper operation of #1, #2, #3, #4 ship service generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2004
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 17 March 2004
Resolved
Provide list of all items to be repaired or corrected while in shipyard prior to repairs
Condition: Damaged By Earlier Event
Due 22 April 2004
Resolved 18 March 2005
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 17 March 2004
Resolved
Conduct no repairs or alterations to shipboard firefighting systems without Coast Guard approval.
Condition: Damaged By Earlier Event
Due 22 April 2004
Resolved 18 March 2005
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 17 March 2004
Resolved
Prior to departure from anchorage test general alarm and remote generator engine stop and record in ships log.
Condition: Damaged By Earlier Event
Due 22 April 2004
Resolved 18 March 2005
Communications › Radio Communications
Issued 11 September 2003
Resolved
Update EPIRB registration with NOAA. LEGACY COMPONENT DESC: EPIRB
Due 11 October 2003
Resolved 6 October 2003
Electrical › Electrical Distribution System (service)
Issued 11 September 2003
Resolved
Provide safety cover for open breaker in radio room panel EP101 and supercargo laundry panel 02-161-2. LEGACY COMPONENT DESC: Circuit Breaker
Due 28 September 2003
Resolved 6 October 2003
Electrical › Electrical Distribution System (service)
Issued 11 September 2003
Resolved
Repair latch to distribution panel ES-52(1) door located near B5 door. LEGACY COMPONENT DESC: Distribution Panel Door
Due 28 September 2003
Resolved 6 October 2003
Resolution: Added twist-lock screws to replace latch.
Electrical › Lighting (service)
Issued 11 September 2003
Resolved
Connect or remove wire to exterior light, outboard starboard side 06 deck forward. LEGACY COMPONENT DESC: Wiring
Due 11 October 2003
Resolved 6 October 2003
Resolution: Wire removed and hole filled.
Fire Fighting › Structural - A Class Divisions
Issued 11 September 2003
Resolved
Adjust closing mechanism to following doors and fire doors properly close when released: main fire door 04 deck forward passageway, 04-190-2, 03-177-2, and unlicensed messroom exterior door. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 28 September 2003
Resolved 6 October 2003
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 11 September 2003
Resolved
Repair head and shower in spare unlicensed stateroom 03-188-8 and deck toilet 03-188-0.
Due 6 November 2003
Resolved 18 March 2005
Fire Fighting › International Shore Connection
Issued 11 September 2003
Resolved
Provide missing bolts for international shore connection. LEGACY COMPONENT DESC: Bolts
Condition: Unknown
Due 28 September 2003
Resolved 6 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 11 September 2003
Resolved
Prove proper operation of all emergency egress hatches in the cargo holds. LEGACY COMPONENT DESC: Emergency Egress
Condition: Improper/Lack of Maintenance
Due 28 September 2003
Resolved 6 October 2003
Fire Fighting › Miscellaneous Items
Issued 11 September 2003
Resolved
Provide missing spanner wrenches for fire stations: E-266-2 and E-280-0. LEGACY COMPONENT DESC: Spanner Wrench
Due 28 September 2003
Resolved 6 October 2003
Fire Fighting › Ventilation Systems
Issued 11 September 2003
Resolved
Prove proper operation of vent fire dampers E-280-2 and A-329-2. Remove object inserted into vent damper E-280-2. LEGACY COMPONENT DESC: Fire Dampers
Due 28 September 2003
Resolved 6 October 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 September 2003
Resolved
Change and label all eyewash stations in cargo holds. LEGACY COMPONENT DESC: Eyewash Stations
Due 28 September 2003
Resolved 6 October 2003
Lifesaving › Lifebuoys
Issued 11 September 2003
Resolved
Remove lifeline from lifebuoy at starboard gangway. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 28 September 2003
Resolved 6 October 2003
Construction/Loadline › Structures › Superstructure
Issued 11 September 2003
Resolved
Repair wasted sheet metal along starboard side bottom of aft house located in passageway between two houses.
Due 6 November 2003
Resolved 18 March 2005
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 11 September 2003
Resolved
Repair as original 36" piece of pipe in way of saltwater sprinkling/AFFF on overhead of "A" deck in area of frame 225.
Due 30 November 2003
Resolved 18 March 2005
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 11 September 2003
Resolved
Prove proper operation of #2, 3, and 4 SSMDG.
Due 7 April 2004
Resolved 18 March 2005
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 11 September 2003
Resolved
Prove proper operation of the safety devices in way of #1 and #2 auxiliary water tube boilers.
Due 31 October 2003
Resolved 18 March 2005
Lifesaving › Lifeboat › Markings
Issued 11 September 2003
Resolved
Properly mark each lifeboat with a boat number and a means of identifying SHUGHART as the vessel to which they belong; markings must be plainly marked or painted so that the markings are visible from above the boat.
Due 18 October 2003
Resolved 14 March 2005
Lifesaving › Lifeboat
Issued 28 August 2003
Resolved
Renew lifeboat windows in way of hazed and weathered glazing. LEGACY COMPONENT DESC: Hatches
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 6 October 2003
Pollution Prevention/Response › Prevention Equipment
Issued 28 August 2003
Resolved
Provide mirrors to witness position of remote operated valves located in lower cargo deck rose boxes.
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 6 October 2003
Electrical › Electrical Distribution System (service)
Issued 24 July 2002
Resolved
REPAIR/RENEW RATCHET CHARGING HANDLE ON # 3 AUX GENERATOR AND BOWTHRUSTER CIRCUIT BREAKERS LOCATED ON AUX SWITCHBOARD LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 24 August 2002
Resolved 23 August 2002
Deck/Cargo › Mooring/Anchoring
Issued 24 July 2002
Resolved
REPAIR LEAKS ON # 12 AND # 13 SERVO PUMPS IN STEERING GEAR COMPARTMENT. LEGACY COMPONENT DESC: Winch
Condition: Unknown
Due 24 August 2002
Resolved 23 August 2002
Deck/Cargo › Holds/Tanks
Issued 24 July 2002
Resolved
REPAIR/REPLACE UV TRIPS: AS-21 AFT MISC. VENT TRIP, MS-100 CARGO HOLDS 3 AND 4 VENT TRIP, MS-105 CARGO HOLDS 3 AND 4 VENT TRIP. LEGACY COMPONENT DESC: Venitlation Fans
Condition: Unknown
Due 24 August 2002
Resolved 23 August 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 24 July 2002
Resolved
REPAIR/REPLACE HIGH JACKET WATER ALARMS ON # 1 AND # 2 AUX GENERATORS. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 24 August 2002
Resolved 23 August 2002
Communications › Alarms/Indicators
Issued 24 July 2002
Resolved
REPAIR/REPLACE ALARM HORNS IN ENGINE SPACES AND BEACON LIGHT IN STEERING GEAR COMPARTMENT. LEGACY COMPONENT DESC: Engineers'''''''''''''''' Assistance-needed Alarm
Condition: Unknown
Due 24 August 2002
Resolved 23 August 2002
Navigation › Piloting/Steering
Issued 24 July 2002
Resolved
PROVE PROPER OPERATION OF PORT BRIDGE WING - CONTROL TRANSFER. LEGACY COMPONENT DESC: Control Transfer
Due 24 August 2002
Resolved 23 August 2002
Engineering › Bilge Water Management System
Issued 24 July 2002
Resolved
REPAIR/REPLACE VALVE OT-5B12. MISSING VALVE ACTUATOR. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 24 August 2002
Resolved 23 August 2002
Communications › Alarms/Indicators
Issued 24 July 2002
Resolved
PROVE PROPER OPERATION OF ALL CARGO HOLD BILGE HIGH LEVEL ALARMS. LEGACY COMPONENT DESC: Bilge Alarm
Due 24 August 2002
Resolved 23 August 2002
Lifesaving
Issued 23 July 2001
Resolved
INSTALL PERMANENT MEANS OF COMMUNICATION AT EMERGENCY CONTROL STAION FOR MAIN PROPULSION ENGINE.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Electrical
Issued 23 July 2001
Resolved
ELIMINATE DEAD GROUND ON PANEL (L/01) IN WINDLASS MACHINE RM SWICTH #12 OF CARGO VENTILATION FAILURE ALARM SYSTEM.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Electrical
Issued 23 July 2001
Resolved
RENEW/REPAIR BROKEN KW METERS FOR #2 AND #3 SHIP SERVICE GENERATORS.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Electrical
Issued 23 July 2001
Resolved
RENEW BROKEN SALT WATER COOLING WATER PIPING TO OIL COOLERS ON #2,#3 AND #4SHIP SERVICE GENERATORS PRIOR TO OPERATING.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Electrical
Issued 23 July 2001
Resolved
RENEW FUEL HOSES ON ALL MAIN GENERATORS THAT ARE NOT CG APPROVED FIRE RESISTANT HOSE OR INSTALLED APPROVED FIRE SLEEVE, PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Electrical
Issued 23 July 2001
Resolved
REPAIR MAJOR OIL LEAK ON #2 GENERATOR PRIOR TO OPERATING THE GENERATOR.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Fire Fighting
Issued 23 July 2001
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS TO SATISFACTION OF CG INSPECTOR, PRIORTO GETTING UNDERWAY.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Navigation
Issued 23 July 2001
Resolved
ALIGN ALL RUDDER ANGLE INDICATORS TO READ ACTUAL RUDDER ANGLE PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Lifesaving
Issued 23 July 2001
Resolved
DEMOSTRATE PROPER OPERATION OF #3 LIFEBOAT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Documentation
Issued 23 July 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Fire Fighting
Issued 23 July 2001
Resolved
ELIMINATE FAULT ALARM ON FIRE CONTROL PANEL AS A RESULT OF THE DISABLED CARBON MONOXIDE DETECTION SYSTEM.
Condition: Unknown
Due 26 September 2001
Resolved 26 February 2002
Resolution: Cleared based on systems manufactures service report faxed to detail this date.
Fire Fighting
Issued 23 July 2001
Resolved
PROVE PROPER OPERATION OF ALL FIRE DOORS.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Lifesaving
Issued 16 March 2001
Resolved
RENEW ALL PIPE INSULATION IN COFFERDAM # 8-227-(21) 0. INSULATION IS SATURATED WITH OIL.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Lifesaving
Issued 16 March 2001
Resolved
RENEW ALL PIPE INSULATION IN COFFERDAM # 8-248-0. INSULATION IS SATURATED WITH OIL._x001C_
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Lifesaving
Issued 27 February 2001
Resolved
Install handrails that comply with Code of Federal Regulations Title 46, Part 92.25-5 to the deck weather decks that were formerly designated as a Helicopter Facility. Install to satisfaction of USCG Marine Inspector no later than March 13, 2001._x001C_
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Documentation
Issued 27 February 2001
Resolved
Modify the vessels Fire Control Plans to indicate weather decks where a Helicopter Facility was formerly located. Correct to satisfaction of USCG Marine Inspector no later than March 13, 2001._x001C_
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Engineering
Issued 7 September 2000
Resolved
DEMOSTRATE 1.5 MAWP HYDROSATIC TEST OF WASTE HEAT BOILER AFTER THE SCHEDULED RE-TUBING AND PRIOR TO OPERATING THE BOILER.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Engineering
Issued 7 September 2000
Resolved
DEMOSTRATE PROPER POPPING PRESSURE OPERATION ON #2 AUX BOILER SAFETY VALVESPRIOR TO ROUTINE OPERATION OF BOILER.
Condition: Unknown
Due 20 November 2000
Resolved 20 November 2000
Documentation
Issued 17 May 2000
Resolved
PROVIDE SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Engineering
Issued 17 May 2000
Resolved
PROVE PROPER OPERATION OF #2 BOILER AUTOMATION.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Navigation
Issued 17 May 2000
Resolved
PRIOR TO PROCEEDING TO OPEN OCEAN ENSURE GMDSS IS OPERATIONAL.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Engineering
Issued 17 May 2000
Resolved
DEMOSTRATE CORRECT POPPING OF WASTE HEAT (STACK) BOILER PRESSURE SAFETY VALVES AFTER BOILER REPAIRS ARE COMPLETE.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Electrical
Issued 17 May 2000
Resolved
WIRE ALL ENGINEROOM VENTILATION FANS TO AUTOMATICALLY SHUTDOWN DURING ACTIVATION OF THE ENGINEROOM CO2 SYSTEM.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Navigation
Issued 10 May 1999
Resolved
Repair faulty hydraulic oil level sensor on stbd steering pump system, testalarm, and fax results to EURMI._x001C_
Condition: Unknown
Due 20 June 1999
Resolved 19 May 1999
Lifesaving
Issued 3 May 1998
Resolved
Provide dates of fuel change for each lifeboat.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Provide copies of fire servicing reports & foam analysis.
Condition: Unknown
Due 3 July 1998
Resolved 11 May 1998
Documentation
Issued 3 May 1998
Resolved
Provide current copies of: 46 CFR 1 to 40, 46 CFR 90 to 139, & 33 CFR.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Engineering
Issued 3 May 1998
Resolved
Repair excessive exhaust leaks on #2 Main Diesel Generator in way of the cylinder exhaust gas bellows.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Construction/Loadline
Issued 3 May 1998
Resolved
Demonstrate proper operation of Shaft Alley "high-high" bilge alarm.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Navigation
Issued 3 May 1998
Resolved
Prove proper operation of EOT power failure alarm.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Engineering
Issued 3 May 1998
Resolved
Repair and prove proper operation of shunt trip for engineroom ventilation breaker. Until this is corrected, temporary notices are to be posted at all engineroom CO2 discharge stations indicating that ventilation must be shut-off before discharing CO2.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Lifesaving
Issued 3 May 1998
Resolved
Make permanent repairs to #2 lifeboat hull.
Condition: Unknown
Due 3 July 1998
Resolved 11 May 1998
Unknown
Issued 3 May 1998
Resolved
Provide proper documentation of fully compliant chemical testing program. Marine employer is not authorized to operate after 03JUN98 unless this requirement has been cleared to the satisfaction of an attending USCG Marine Inspector.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Lifesaving
Issued 3 May 1998
Resolved
Conduct full load suspension and release test for #1 & #3 lifeboats.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Lifesaving
Issued 3 May 1998
Resolved
Total persons allowed on board is limited to 57 until 47 additional lifejackets are provided.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Electrical
Issued 3 May 1998
Resolved
Repair/replace unreliable UPS for general alarms. UPS has history of failure and is not working at this time. Batteries temporarily installed to supply General Alarm circuit must be checked daily.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Documentation
Issued 3 May 1998
Resolved
Provide Coast Guard approved fire control plan or submit plan to MIO Europefor approval.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Electrical
Issued 3 May 1998
Resolved
Demonstrate proper operation of reverse power trip for #2 Auxiliary Diesel Generator.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Engineering
Issued 22 May 1997
Resolved
MAKE PROPER REPAIRS AND PROVE PROPER OPERATION TO THE MAIN PROPULSION AIR START SYSTEM. PROVIDE WRITTEN REPORT OF PAST AND PRESENT PROBLEMS WITH A FINAL RESOLUTION.
Condition: Unknown
Due 20 June 1997
Resolved 27 May 1997
Lifesaving
Issued 16 May 1997
Resolved
LOWER, RELEASE AND OPERATE BOTH STBD LIFEBOATS.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
LOWER, RELEASE AND OPERATE BOTH PORT LIFEBOATS.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Engineering
Issued 16 May 1997
Resolved
REPAIR SIGHT GLASS FOR #2 BOILER.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Construction/Loadline
Issued 16 May 1997
Resolved
PROVE PROPER OPERATION OF ALARMS ON WTDs B-227(55)-2, E-263-2, AND SHAFT ALLEY DOOR.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Fire Fighting
Issued 16 May 1997
Resolved
TEST FIRE DETECTION SYSTEM.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Fire Fighting
Issued 16 May 1997
Resolved
REMOVE PLASTIC HOSE FROM SPRINKLER HEADS IN CARGO HOLDS AT BULKHEADS C-297-1, C-263-1, AND D-227-1.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Electrical
Issued 16 May 1997
Resolved
RENEW ALL FUEL/SUCTION/RETURN LINES FOR SS GENERATORS DAMAGED.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
CONDUCT FIRE AND BOAT DRILLS TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
INSTALL SUITABLE NOTICE ON THE WHEEL FOR THE HELMSMAN AT AFTER STEERING STATION TO INDICATE RIGHT/LEFT RUDDER.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Fire Fighting
Issued 16 May 1997
Resolved
PROVIDE DOOR CLOSER FOR FSD PASSAGE A-195-0/DRIVE THRU A-213-2.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Electrical
Issued 16 May 1997
Resolved
PROVIDE COPY OF LOG ENTRIES FOR TEST OF TRIPS OF ALL DIESEL GENERATORS.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Electrical
Issued 16 May 1997
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP, LUBE OIL AND HIGH TEMP ALARMS FORTHE EMERGENCY GENERATOR.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
PROVIDE OPEN/CLOSE LABELS FOR EMERGENCY ECR ESCAPE DOOR HANDLES.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
PROVIDE INSTRUCTIONS AND MARKINGS FOR STEERING GEAR CHANGEOVER IAW 46CFR97.37-33.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
PROVIDE EVACUATION SIGNS AT CO2 ALARMS IN ENGINEROOM AND ECR IAW 46CFR97.37-9.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Electrical
Issued 16 May 1997
Resolved
PROVIDE WORK PLATFORM FOR EMERGENCY GENERATOR FOR INSPECTION AND MAINTENANCE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Fire Fighting
Issued 16 May 1997
Resolved
CORRECT DISCREPANCIES ON ENGINE ROOM CO2 SYSTEM INSTRUCTION PLACARD AS IT DOES NOT MATCH SYSTEM.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Engineering
Issued 16 May 1997
Resolved
PROVIDE COPY OF LOGBOOK ENTRIES FOR TEST OF ALARMS, SHUTDOWNS, AND OVERSPEED TRIP OF MAIN ENGINE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
POST INSTRUCTIONS, IN AT LEAST 1/2" HIGH LETTERS AND FIGURES, IN THE STEERING ENGINE ROOM RELATING, IN ORDER, THE DIFFERENT STEPS TO BE TAKEN INCHANGING TO THE EMERGENCY STEERING GEAR.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Construction/Loadline
Issued 16 May 1997
Resolved
PROVE PROPER OPERATION OF WTD 2-114-2 OF IN REMOTE AND LOCAL POWER CONTROLS; LOCAL MANUAL CONTROL IS OPERATIONAL.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Engineering
Issued 15 March 1997
Resolved
SSDG PRIME MOVERS #1&4 EXPERIENCED CRANKCASE EXPLOSIONS DUE TO BEARING FAILURES. UPON REPAIR, PROVE PROPER OPERATION OF #1&4 SSDG IN ALL MODES OFOPERATION INCLUDING LOAD SHARING & SHEDDING.
Condition: Unknown
Due 15 March 1997
Resolved 15 March 1997
Engineering
Issued 20 December 1996
Resolved
Crop and renew wasted seawater cooling discharge piping at frame station 182 to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Construction/Loadline
Issued 14 December 1996
Resolved
Provide documentation, from the manufacturer, that the bilge dewatering valves for the ships cargo hold dewatering system are certified waterproof.
Condition: Unknown
Due 14 December 1996
Resolved 14 December 1996
Construction/Loadline
Issued 14 December 1996
Resolved
Prior to cargo operations, prove proper operation of the ships cargo hold dewatering system to the cognizant OCMI.
Condition: Unknown
Due 14 December 1996
Resolved 14 December 1996
Fire Fighting
Issued 14 December 1996
Resolved
Relocate or add an additional light or alarm for the general alarm system in the emergency generator room. Prove operation of same.
Condition: Unknown
Due 14 December 1996
Resolved 14 December 1996
Construction/Loadline
Issued 6 December 1996
Resolved
Prove proper operation of ships cargo hold dewatering system in both remote& manual modes. To be completed prior to vessel departing the port of Hampton Roads and not later than 5JAN97.
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Construction/Loadline
Issued 6 December 1996
Resolved
Provide documentation from the manufacturer that the EIM motor operated valves for the ships cargo hold dewatering system are certified waterproof not later than 5JAN96.
Condition: Unknown
Due 13 December 1996
Resolved 13 December 1996
Lifesaving
Issued 8 November 1996
Resolved
Vessel is not to load or carry cargo until the fixed fire and combustible gas detection system for the cargo holds is repaired and demonstrated to the attending Marine Inspector, not later than 06 DEC 96.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Engineering
Issued 1 November 1996
Resolved
PROVIDE CLASS SOCIETY REPORT ON DAYTANK FRACTURE REPAIRS (2-213-0 FWD BULKHEAD), AND TESTING.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Fire Fighting
Issued 23 July 1996
Resolved
Install additional CO2 sirens in the fixed Engine Room CO2 system,as noted;1ea. engineer's workshop, 1 ea. mid level fwd bulkhead,_x001C_ 1 ea. Stb diesel eng room fwd bulkhead, 1 ea. Stb aux mach room upper levelNASSCO eng change number 7120 E-06
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Construction/Loadline
Issued 2 May 1996
Resolved
Repair ballast system remote controls. Demonstrate proper operation of the entire ballast system. _x001C_
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Fire Fighting
Issued 2 May 1996
Resolved
Provide additional sirens for the fixed CO2 system in the engineroom: 1 each engineer's workshop; 1 each mid-level forward bulkhead; 1 each stbd diesel engineroom forward bulkhead; and 1 each stbd auxiliary machinery room upper level (NASSCO engineering change number 7120 E-06). _x001C_
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996