USNS YANO is a 1980 freight ship. The Coast Guard has recorded 109 inspections since 1996, most recently in February 2022, along with 155 deficiencies — 4 with no resolution recorded — and 6 operational controls, 1 with no removal date recorded.

Records from 1996 to 2022. Most recent: inspection, 23 February 2022.

Built
1980
Last inspected
23 February 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7825409 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
433041
Flag
UNITED STATES
—
Maury page id
psix-433041

Inspections, by type

…with no type recorded33
…past their stated due date2
Years with a record 22 calendar years (1996–2022)
The 109 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25900 - Dead Weight, Ton
59458 - Displacement, Ton
61221 - Convention (Subpart B), Gross Ton
18477 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BUFFALO 410 Tank Barge · MISLE 953633 · 27 January 2017 · activity 6079689USNS SHUGHART Freight Ship · MISLE 431934 · 26 March 2001 · activity 745568USNS SEAY Public Freight · MISLE 502200 · 26 March 2001 · activity 745568USS TISDALE Public Vessel, Unclassified · MISLE 363298 · 25 February 1996 · activity 61829USS VANDEGRIFT (FFG 48) Public Vessel, Unclassified · MISLE 437330 · 25 February 1996 · activity 61829

Inspection history · 109

23 February 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7400516
11 March 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6640075
20 December 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6601091
7 November 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6581306
6 September 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6533609
2 July 2018 Permit to Proceed · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6475403
31 January 2018 Permit to Proceed
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6347723
20 November 2017 ACP Additional Oversight – Risk Assessment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6314376
6 September 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6262148
29 August 2017 ISM SMC Audit
Administrative · Commandant (CG-5P-TI) · Activity 6307441
28 June 2017 ACP Additional Oversight – Risk Assessment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6190405
14 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6181653
30 January 2017 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6075890
27 January 2017 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6078760
27 January 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6079689
24 January 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6083098
2 June 2016 Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952961
19 May 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5884474
4 March 2016 ACP COI Oversight · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5824329
25 July 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5213896
29 May 2012 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4317624
10 January 2011 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3920198
10 April 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3449840
28 October 2008 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3354547
1 April 2008 ACP Annual Oversight
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3174824
18 December 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3117487
19 September 2007 In-Service Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3061388
27 July 2007 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3008725
19 October 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2803843
1 June 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2667603
13 March 2006 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2602485
15 February 2006 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2587332
2 December 2005 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2547085
22 November 2005 Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2541905
26 October 2005 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2523787
25 October 2005 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2541920
14 September 2005 Drydock Extension
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2547751
19 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2432327
6 July 2005 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2419879
2 May 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2333725
21 April 2005 Deficiency Check
Physical examination · Activities Europe · Activity 2407310
14 April 2005 Damage Survey
Physical examination · Activities Europe · Activity 2333820
7 April 2005 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2332946
2 April 2005 Type not recorded
No type recorded · Activities Europe · Activity 2361034
25 March 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2319217
22 March 2005 Type not recorded
No type recorded · Activities Europe · Activity 2324298
29 January 2005 Administrative Inspection · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2289036
10 November 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2431831
26 July 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2153259
6 July 2004 Deficiency Check · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2160603
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104904
4 May 2004 Type not recorded
No type recorded · Activities Europe · Activity 2058747
4 May 2004 Type not recorded
No type recorded · Activities Europe · Activity 2438800
21 April 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2049005
19 April 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2063909
17 February 2004 Administrative Inspection
Administrative · Activities Europe · Activity 2015409
11 February 2004 Type not recorded
No type recorded · Activities Europe · Activity 2008975
10 February 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2004118
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997524
8 January 2004 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1980187
22 December 2003 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1972109
7 November 2003 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1949147
8 October 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1923722
25 September 2003 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1912763
16 September 2003 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1905966
16 September 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1906060
5 September 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1897732
3 September 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1900925
15 May 2003 Type not recorded
No type recorded · Activities Europe · Activity 1798728
13 May 2003 Type not recorded
No type recorded · Activities Europe · Activity 1798727
12 May 2003 Type not recorded
No type recorded · Activities Europe · Activity 1798729
19 April 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1785225
9 April 2003 Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1768371
20 February 2003 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1747775
24 September 2002 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1691890
9 April 2002 Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1602854
15 November 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1076764
18 June 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1065391
6 April 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1370115
26 March 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 745568
20 March 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1058313
27 February 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1433792
2 February 2001 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1058401
1 February 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1395611
22 January 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1057163
8 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 825228
27 October 2000 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1361789
11 July 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 523445
12 May 2000 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 818770
1 May 2000 Deficiency Check · Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361498
3 March 2000 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361348
11 February 1999 COI Inspection
Physical examination · Activities Europe · Activity 1372498
6 July 1998 Deficiency Check
Physical examination · Activities Europe · Activity 792701
5 April 1998 Re-Inspection
Physical examination · Activities Europe · Activity 1421484
2 October 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1372006
18 August 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 182346
16 May 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 71559
5 April 1997 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1419743
14 February 1997 Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1414756
31 December 1996 Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1102301
30 September 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1145621
30 June 1996 Construction Oversight · Reflagging & Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1093039
20 May 1996 Damage Survey · Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1101768
31 March 1996 Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1080811
12 March 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 886264
5 March 1996 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1398414
1 March 1996 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1447540
25 February 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 61829
17 February 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 164887

Deficiency record · 155

Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 28 November 2017 No resolution recorded
History substandard condition of both vessels, and lack of plans or progress in correcting deficiencies and conditions of class. Removed COI.
Action required: 705 - Other - as specified
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 June 2017 Resolved
E-gen did not self start upon darken ship condition. SOLAS 74 (14 Amend.) II-1/43.3.1.2
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 June 2017 Resolved
Class 3 watertight door was unable to be remotely operatetd from remote operating station. SOLAS 74 (14 Amend.) II-1/13.8.1
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 June 2017 Resolved
Class 3 watertight door in auxilary cooler room had no visual light indicator for opening/closing. SOLAS 74 (14 Amend.) II-1/13.8.2
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Discharge Outlets
Issued 28 June 2017 Resolved
Deluge foam firefighting system sprinkler heads found missing on several waetherdeck outlets. SOLAS 74 (14 Amend.) II-2/14.1
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 28 June 2017 Resolved
Fixed Foam system actuator covers found frozen in place making them unable to be operated. SOLAS 74 (14 Amend.) II-2/14.1
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Communications › Radio Communications › EPIRB
Issued 28 June 2017 Resolved
Hydrostatic Release for EPIRB expired. SOLAS 74 (14 Amend.) IV/7.1.6.4
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Fire Fighting › Structural - Horizontal Zones › General
Issued 28 June 2017 Resolved
Several horizontal zone fire boundary doors did not close properly. SOLAS 74 (14 Amend.)II-2/14.2.1.1.1
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Lifesaving › Lifebuoys › Serviceable
Issued 28 June 2017 Resolved
Several life bouy hand lines deteriorated and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 28 June 2017 Resolved
Improper installation/lack of fire stop material in through hull area surrounding post manufacturing installation of wiring in battery room.
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Construction/Loadline › Structures › Superstructure
Issued 28 June 2017 Resolved
Hand Rail on 01Deck Catwalk wasted creating an unsafe condition.
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Construction/Loadline › Structures › Scuttle
Issued 28 June 2017 Resolved
Hinge on emergency escape scuttle from radio room found wasted making it an unsafe condition. SOLAS 74(14 Amend.) II-2/13.1.2
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Construction/Loadline › Structures › Superstructure
Issued 28 June 2017 Resolved
Handrail on stbd side liferaft embarkation area wasted/holed creating an unsafe condition. ILL Reg 25
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Fire Fighting › Ventilation Systems › Ducts
Issued 28 June 2017 Resolved
Exhaust Vent 02-015-2 restricted by piece of linen obstructing airflow. SOLAS 74('14 Amend.) II-2/14.1.1
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 28 June 2017 Resolved
Several ventilation covers rusted into fixed position making them inoperable. SOLAS 74('14 Amend.) II-2/14.1.1
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 June 2017 Resolved
Several watertight doors not creating appropriate seal and are in need of adjustment. ILL Reg 12
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Deck/Cargo › Cargo Stowage › General
Issued 28 June 2017 Resolved
Cargo Securing 'D' rings on weather decks found rusted into stationary position. SOLAS 74('14 Amend.) VI/5.1
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Lifesaving › Lifebuoys › Size
Issued 28 June 2017 Resolved
Bridge wing life bouys installed with traditional vs. bridge bouys. LSA Code II/2.1.1.7
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Lifesaving › Line-Throwing Appliances › Instructions/Diagrams
Issued 28 June 2017 Resolved
Line throwing gun instructions did not include how to charge system. LSA CODE VII/7.1.1.4
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Fire Fighting › Fire Hydrants › Condition
Issued 28 June 2017 Resolved
Multiple Fire stations found with water in fire hoses after charging firepump but before opening valves indicating a potential leak by. SOLAS 74('14 Amend.)II-2/10.2.1.4.2
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Fire Fighting › Means of Escape › Blocked
Issued 28 June 2017 Resolved
Emergency Egress form Boatswain hold found blocked with gear. SOLAS 74('14Amend.) II-2/13.1.2
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: Rcvd report from Class attesting to proper opperation. Verified by attending MI.
Engineering › Bilge Water Management System › Valve
Issued 28 June 2017 Resolved
Indicator Valve for OT7 MOV does not indicate valve position. SOLAS 74(Amend. 2014) II-1/35-1.2.4
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Engineering › Bilge Water Management System › Strainer
Issued 28 June 2017 Resolved
OT9 Bilge foot pickup missing strainer. SOLAS 74(Amend. 14) II-1/35-1.2 ABS RULES 4/4/3/5.7
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 28 June 2017 Resolved
Crane annual inspection was not completed. Limit switches for both aft cranes were inoperable.
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Reported to Class and accepted as Condition of Class.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 19 June 2017 No resolution recorded
During periods of high water, unless moored to a shoreside facility or mooring buoys all deep draft vessels must have three means to hold position. Vessel lost port anchor on 13 June 2017. While the [name withheld] reads above 8 feet on its Carollton guage, your vessel is required to have assist tugs of adequate horsepower while transiting the lower Mississippi River.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2017 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 19 June 2017 No resolution recorded
On 16 June 2017, the vessel experienced a failure of the exhaust hydraulic valve system on the #6 cylinder. Provide a report from your classification society attesting to the proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2017 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 January 2017 Resolved
Provide risk assessemnt for voyage to Port Arthur.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2017
Resolution: Risk assessment provided.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 January 2017 Resolved
Fuel oil fill system to tank 7-280-1 allowed fuel oil to spill into cargo hold #2 - e-deck. Provide a proposal to the Authorized Classification Society and the Coast Guard on how the vessel will identify and rectify the problem, prior to the issuance of COI.
Action required: 705 - Other - as specified
Resolved 8 February 2017
Resolution: Fuel oil system repaired to satisfaction of both ABS & USCG.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 January 2017 Resolved
Fuel oil fill system to tank 7-280-1 allowed fuel oil to spill into cargo hold #2 - e-deck. Repair fuel oil fill system and demonstrate proper operation to the satisfaction of the Authorized Classification Society and the Coast Guard, prior to the issuance of new COI and prior to filling tank 7-280-1.
Action required: 705 - Other - as specified
Resolved 8 February 2017
Resolution: Fuel oil system repaired to satisfaction of ABS & USCG.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 4 August 2016 No resolution recorded
Vessel’s Authorized Classification Society has not completed approval of engine automation. The vessel must have a fully manned engine room until the automation is approved. Provide class report to USCG when all testing is completed.
Action required: 705 - Other - as specified
Engineering › Steering Gear System › Feedback Unit
Issued 10 January 2011 Resolved
Prove proper operation of the steering phase failure alarms.
Action required: 705 - Other - as specified
Resolved 15 February 2011
Resolution: ABS has taken responsibility for the alarms.
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 April 2008 Resolved
Prove proper operation of 3cm Radar prior to u/w operations.
Action required: 705 - Other - as specified
Resolved 1 May 2008
Resolution: After recieving tech report for 3 cm radar vessel was attended and proper operation of the radar was observed.
Engineering › Compressed Air System (start air) › Valve
Issued 13 March 2006 Resolved
Provide proof of shopbench testing of all air receiver relief valves.
Due 30 April 2006
Resolved 13 June 2006
Resolution: CG 835 cleared by Sector Delaware Bay inspectors 13June06
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2006 Resolved
Renew frayed wire rope on accomodation ladder.
Due 30 April 2006
Resolved 1 June 2006
Resolution: CG 835 cleared by Sector Delaware Bay inspectors.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 March 2006 Resolved
Upon activation of vessel, and prior to getting underway, conduct satisfactory fire & boat drills.
Action required: 705 - Other - as specified
Resolved 14 February 2007
Engineering › Steam Boiler (auxiliary/waste heat) › Rear Wall/Side Wall Tubes
Issued 2 December 2005 Resolved
Conduct hydrostatic tests of No. 1 & No. 2 auxiliary boilers to 1.25 times the MAWP, in accordance with 46 CFR 61.05-10(c), in the presence of a USCG marine inspector.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 15 February 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 23 November 2005 Resolved
Vessel to depart Baltimore, MD, and proceed directly to Boston, MA, via the Chesapeake Bay and East coast to arrive no later than 1 Dec 05. Vessel shall exchange ballast before arriving in Boston, MA. Upon arrival in Boston, MA, the vessel shall immediately notify the local OCMI of dry-docking and intended repairs.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 2 December 2005
Resolution: Examined ballast water log and found that vessel had exchanged ballast for all tanks.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 6 July 2005 Resolved
Replace 32 expired or damaged food rations to meet minimum requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Items replaced.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 6 July 2005 Resolved
Replace 21 expired or damaged water rations to meet minimum requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Items replaced.
Lifesaving › Lifeboat Equipment › Portable Fire-extinguishing Equipment
Issued 6 July 2005 Resolved
Service lifeboat extinguishers for each boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Items serviced.
Lifesaving › Inflatable Liferafts › Servicing
Issued 6 July 2005 Resolved
Conduct required annual servicing on all inflatable liferafts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Liferafts serviced by approved facility.
Lifesaving › Launching Appliances › Falls
Issued 6 July 2005 Resolved
Conduct required testing of all lifeboat davits and falls.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2006
Resolution: Completed satisfactory weight testing of all lifeboats, davits and falls.
Communications › Radio Communications › EPIRB
Issued 6 July 2005 Resolved
Provide updated and current registration for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Registration updated.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 6 July 2005 Resolved
Replace and service both expired SARTs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: New batteries installed.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 6 July 2005 Resolved
Prove proper operation and launching of all lifeboats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Liferafts serviced by approved service facility.
Communications › Internal Communications System › Sound-powered Telephone
Issued 6 July 2005 Resolved
Prove proper operation of lifeboat public address system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2005
Resolution: PA system operations but talk back system has intermittent problems. Vessel to address in dry-docking.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 July 2005 Resolved
Conducted required annual servicing of all fire extinguishers onboard the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Annual servicing conducted.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pressure
Issued 6 July 2005 Resolved
Prove proper operation of sprinkler and AFFF system.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2006
Resolved 15 February 2006
Fire Fighting › Fixed Fire Detection System › Approval
Issued 6 July 2005 Resolved
Prove proper operation of fire and smoke detection system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: New system installed and tested - See activity #2523787.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 July 2005 Resolved
Provide updated and approved fire control plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: New plan submitted and approved for sister ship USNS Shughart. Verification should again take place at next annual exam after dry-docking.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 6 July 2005 Resolved
Prove proper operation of audible alarms for steering gear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2005
Resolution: Tested prior to getting underway.
Engineering › Steering Gear System › Valve
Issued 6 July 2005 Resolved
Repair hydraulic leaks in overhead fill line, oil filters, and at pilot valves on each system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2006
Resolution: Examined forward and aft hydraulic rooms and found leaks satisfactorily repaired.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 6 July 2005 Resolved
Repair leaking A/C discharge line from engine control room that is creating an electrical hazard and flooding on deck below.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Line repaired.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 6 July 2005 Resolved
Renew/replace oil soaked lagging throughout engine room - booster pump room, FOP, pre-cool SW pump #1, Aux bilge pump, FO filter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 6 July 2005 Resolved
Secure loose/open electrical connection in FOP room on aft bulkhead and remove deadend wire from behind main FOP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 6 July 2005 Resolved
Repair loose/open connection of fuel oil transfer pump - PI 267.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2005 Resolved
Repair weep in SW Cooling line forward on main engine lower level starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2006
Resolution: Examined and found satisfactory.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 July 2005 Resolved
Repair open electrical box fitting in generator room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 July 2005 Resolved
Repair leak in #3 FO filter on main diesel generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Engineering › Steam System (auxiliary) › Piping
Issued 6 July 2005 Resolved
Repair leaking aux steam line by door and over generator #2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Line replaced.
Engineering › Compressed Air System (start air) › Piping
Issued 6 July 2005 Resolved
Repair leaking heat exchanger on main air compressor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 6 July 2005 Resolved
Repair stack cooling drain lines in aux generator room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2006
Resolution: Examined and found satisfactory.
Engineering › Bilge Water Management System › Valve
Issued 6 July 2005 Resolved
Secure/renew remote actuated valve and deck plating near emergency bilge suction panel starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 July 2005 Resolved
Reconnect remote valve trick wheel in shaft alley - MD5B15.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2005 Resolved
Repair leaking ME jacket water cooler #2 heat exchanger.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2006
Resolution: Examined and found satisfactory by ABS surveyor.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 6 July 2005 Resolved
Conduct abandon ship drill prior to activation.
Action required: 705 - Other - as specified
Resolved 22 November 2005
Operations/Management › Drills/Instruction › Fire
Issued 6 July 2005 Resolved
Conduct fire drill prior to activation.
Action required: 705 - Other - as specified
Resolved 22 November 2005
Resolution: Fire drill conducted in galley.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 July 2005 Resolved
Vessel to complete additional annual inspection during the regularly scheduled ABS annual surveys in Jan 06 or prior to its activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2006
Resolution: Annual scheduled for 14Mar06.
Engineering › Feedwater/Condensate Water System › Piping
Issued 14 April 2005 Resolved
Supply document on 1) Specifications of the pipe used to make the required spool piece. 2) The welding procedures used to fabricate the spool piece. 3) The name and qualifications of the welder who performed the welding.
Condition: Unknown
Due 30 April 2005
Resolved 21 April 2005
Resolution: Received requested infomation.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Report of Potential Vessel Casualty
Issued 14 April 2005 Resolved
Submit a CG 2692 for the engine room flooding.
Condition: Unknown
Due 30 April 2005
Resolved 28 April 2005
Resolution: Recieved 2692
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 7 April 2005 Resolved
Prior to vessel sailing after arrival at next U.S. port, but no later than next scheduled dry dock (31Oct05), make modifications to the fixed CO2 fire fighting systems to match approved drawings dated March 17, 2005 by the CG Marine Safety Center. The installation, workmanship, and testing shall be to the satisfaction of attending CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2005
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 25 March 2005 Resolved
10cm developed an error in the processing board, display continued to work.
Condition: Unknown
Due 25 March 2005
Resolved 25 March 2005
Resolution: Sperry tec completed repairs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2004 Resolved
Ensure wires in overhead between # 3 and # 4 MDG's are run correctly using proper wire supports and banding. Remove all plastic tie wraps.
Condition: Improper Installation
Due 23 October 2004
Resolved 22 September 2004
Engineering › Feedwater/Condensate Water System › Piping
Issued 6 July 2004 Resolved
Complete temporary repair to include welding a doubler plate over holded area of condesate drain piping located on port side in overhead of cooler room.
Condition: Improper/Lack of Maintenance
Due 23 October 2004
Resolved 1 September 2004
Engineering › Feedwater/Condensate Water System › Piping
Issued 6 July 2004 Resolved
Complete permanent repairs to temp repair on condensate piping, port side overhead in cooler room at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 October 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 6 July 2004 Resolved
Provide an approved CO2 system installation drawing for the engine room.
Condition: Unknown
Due 23 November 2004
Resolved 7 April 2005
Resolution: Received approved drawings.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 6 July 2004 Resolved
Prove proper operation of overspeed trip indication on # 3 MDG.
Condition: Improper/Lack of Maintenance
Due 23 October 2004
Resolved 22 September 2004
Electrical › Electric Generation Source (service) › Panelboard
Issued 6 July 2004 Resolved
Repair/Replace # 2 ADG alarm panel acknowledge switch and alarm indication panel.
Due 23 November 2004
Resolved 17 October 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2004 Resolved
Repair/Replace leaking genset cooling lines on all MDG's.
Condition: Improper/Lack of Maintenance
Due 23 October 2004
Resolved 1 September 2004
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 6 July 2004 Resolved
Renew all exterior foam activation buttons at each foam hose reel with watertight switchs/push buttons
Condition: Improper/Lack of Maintenance
Due 23 November 2004
Resolved 17 October 2004
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 July 2004 Resolved
Prove proper operation of all Cargo Hold fire detection modules prior to loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 July 2004 Resolved
Prove proper operation of the 01 hoistable deck cargo hold 4, A deck aft, and cargo hold # 3 bottom of ramp on port side lights
Due 30 August 2004
Resolved 1 September 2004
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 6 July 2004 Resolved
Prove proper operation/automation of # 2 boiler.
Due 23 October 2004
Resolved 22 September 2004
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 July 2004 Resolved
Clear fault by replacing sensor and test alarm on the following detector: Fan 79, CH 5, A Deck, Fr 174: Duct 5-2-1D.
Due 1 October 2004
Resolved 17 October 2004
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 6 July 2004 Resolved
Renew two embarkation aids that failed during testing on port side.
Due 3 September 2004
Resolved 3 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2004 Resolved
Renew/Repair spool piece on fresh water cooler # 1 sea water inlet.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 24 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2004 Resolved
Secure wires with proper banding on 05 level stbd side between new and old houses.
Condition: Improper Installation
Due 3 September 2004
Resolved 3 September 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2004 Resolved
Repair wiring conduit leading into supply fan in the incinerator room.
Condition: Damaged By Earlier Event
Due 3 September 2004
Resolved 3 September 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 6 July 2004 Resolved
Provide instructions and piping diagrams that meet 46 CFR 95.15-10(h) for incinerator room CO2 system.
Condition: Improper Installation
Due 3 September 2004
Resolved 3 September 2004
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 July 2004 Resolved
Provide a non-conductive deck covering in front of Engine Room Ventilation Starter switchboard.
Condition: Improper Installation
Due 3 September 2004
Resolved 3 August 2004
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 July 2004 Resolved
Provide a non-conductive deck covering in the rear of the main switchboard in accordance with 46 CFR 111.30-11.
Condition: Improper Installation
Due 3 September 2004
Resolved 3 August 2004
Engineering › Steam System (main) › Piping
Issued 6 July 2004 Resolved
Repair steam leak by entrance door in purifier room.
Condition: Damaged By Earlier Event
Due 3 September 2004
Resolved 3 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2004 Resolved
Repair/Renew saltwater temperature inlet nipple on S/W cooler # 2.
Due 3 September 2004
Resolved 3 September 2004
Lifesaving › Buoyant Smoke Signals › General
Issued 6 July 2004 Resolved
Properly place stbd lifebuoy smoke signal to allow it to fall unobstructed into the water.
Condition: Improper Installation
Due 3 September 2004
Resolved 3 August 2004
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 6 July 2004 Resolved
Repair 03 level fire door to allow it to close when released.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 3 August 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 6 July 2004 Resolved
Renew key glass on emergency gear locker # 3.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 3 August 2004
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 4 May 2004 Resolved
Effect repairs to the #9 and #11 cylinder heads and prove proper operation of the main diesel engine prior to departure from the Port of Rota to the satisfaction of the cognizant OCMI. Provide a copy of the manufacturer's technical report for review. LEGACY COMPONENT DESC: Cylinder Head
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2004
Resolved 3 June 2004
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 17 February 2004 Resolved
Prove proper operation of the main propulsion engine controls from the pilot house. Engine room shall be manned until fully functional.
Action required: 705 - Other - as specified
Due 3 March 2004
Resolved 3 March 2004
Stability › Watertight Integrity
Issued 8 January 2004 Resolved
Vessel Representative to submit repair proposal for water tight door C227(40)-2 to USCG Activities Baltimore for approval. Upon completion of repairs, make available for test/inspection by USCG/ABS. All repairs must be completed to the satisfaction of USCG prior to sailing LEGACY COMPONENT DESC: Water Tight Door
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2004
Resolution: Conducted operational test of WTD and all associated hydraulics.
Navigation › Piloting/Steering
Issued 22 December 2003 Resolved
Make permanent repairs to the steering gear control system on the bridge.
Due 29 December 2003
Resolved 24 December 2003
Resolution: Conducted satisfactory testing of steering gear control system on the bridge.
Navigation › Collision/Grounding Avoidance
Issued 16 September 2003 Resolved
VESSEL'S SECONDARY RADAR IS INOPERATIVE. LEGACY COMPONENT DESC: Radar
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 10 October 2003
Resolution: Received certified tech report radar fully operational.
Navigation › Collision/Grounding Avoidance
Issued 16 September 2003 Resolved
CONDUCT REPAIRS AND FULL FUNCTION TEST I.A.W. MANUFACTURERS STANDARDS TO SECONDARY 10CM RADAR. TO BE COMPLETED TO THE SATISFACTION OF C.G. MARINE INSPECTOR. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 16 September 2003
Construction/Loadline › Structures
Issued 10 April 2003 Resolved
Repair hydraulic leak on "B" deck, frame 149.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Lifesaving › Lifeboat
Issued 9 April 2003 Resolved
Replace rusted buckets, secure oars and boat hooks, and dewater bilges on all lifeboats.
Action required: 705 - Other - as specified
Due 10 May 2003
Resolved 16 April 2003
Lifesaving › Lifeboat Equipment
Issued 9 April 2003 Resolved
Repair compass on #3 lifeboat.
Action required: 705 - Other - as specified
Due 10 May 2003
Resolved 16 April 2003
Lifesaving › Lifeboat
Issued 9 April 2003 Resolved
Replace peeling retro tape and replace food rations with broken seals on # 2 lifeboat.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Lifesaving › Embarkation Appliances/Stations
Issued 9 April 2003 Resolved
Repair broken emergency light on port embarkation area.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Construction/Loadline › Structures › Scuttle
Issued 9 April 2003 Resolved
Clean and lubricate all working parts including hinges on emergency escape scuttles.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Fire Fighting › Structural Fire Protection - General
Issued 9 April 2003 Resolved
Repair gasket on fire screen door C-227 (40)-2.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Electrical › Electric Supply System (service)
Issued 9 April 2003 Resolved
Reconnect or remove dead end wires on #1 and #2 main generators water cooling sensors.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Fire Fighting › Fire Hydrants
Issued 9 April 2003 Resolved
Tighten or repack fire station valves.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 9 April 2003 Resolved
Repair/ reconnect heat sensor on 05 hold starboard, forward.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 9 April 2003 Resolved
Repair overhead rudder angle indicator on bridge to show correct angle of rudder.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Engineering › Steering Gear System
Issued 9 April 2003 Resolved
Repair limit switch so rudder can move to all angles in hand and NFU modes.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 10 April 2003
Electrical › Lighting (emergency)
Issued 9 April 2003 Resolved
Repair emergency lighting in hospital and hospital toilet space.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Electrical › Lighting (service)
Issued 9 April 2003 Resolved
Repair lights in 02-211-3 and 05-204-1 accomidation spaces.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Fire Fighting › Combustible Materials
Issued 9 April 2003 Resolved
Clean all lint traps and dryers.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 9 April 2003 Resolved
Secure nitrogen bottles in dry stores.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 April 2003 Resolved
Prove proper operation of main engine automation.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Lifesaving › Launching Appliances
Issued 9 April 2003 Resolved
Prove lifeboat fall are of rotation-resistant and corrosion-resistant steel wire rope.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 16 April 2003
Lifesaving › Lifeboat › Hull
Issued 24 September 2002 Resolved
MAKE REPAIRS TO #4 LIFEBOAT.
Due 24 October 2002
Resolved 17 October 2002
Engineering
Issued 15 November 2001 Resolved
MAKE REPAIRS TO FUEL OIL LEAKS ON ALL MAIN DEISEL ENGINE'S FUEL OIL PUMPS IAW WITH MANUFATURER SPECS, PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Engineering
Issued 15 November 2001 Resolved
PROVE CONSISTENT STARTS ON #3 MAIN GENERATOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Lifesaving
Issued 15 November 2001 Resolved
PROVE PROPER SELF CLOSING AND LATCHING OF ALL STAIRTOWER FIRE DOORS IN THE HOUSE, PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Fire Fighting
Issued 6 April 2001 Resolved
PROVIDE PROPER OPERATION OF WARNING ALARM FOR CARGO HOLD FIRE DOOR _x001C_ C-227(40)-2.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Electrical
Issued 6 April 2001 Resolved
MAKE PERMANENT REPAIRS TO LEAK IN #2 AUX GENERATOR'S EXHAUST PIPE._x001C_
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Navigation
Issued 6 April 2001 Resolved
RENEW BROKEN BRIDGE WINDOW, CENTER LINE._x001C_
Condition: Unknown
Due 30 January 2002
Resolved 9 April 2002
Resolution: Bridge window repalced.
Lifesaving
Issued 6 April 2001 Resolved
DEMONSTRATE FIRE AND BOAT DRILL PRIOR TO GETTING UNDERWAY TO THE SATISFACTION OF CG INSPECTOR._x001C_
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Engineering
Issued 6 April 2001 Resolved
RENEW F/O HOSE WITH APPROVED FLAME RETARDANT HOSE OR INSTALL FIRE SLEEVE_x001C_ #1, 2, & 3 AUX GEN_x001C_
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Electrical
Issued 6 April 2001 Resolved
DEMONSTRATE LOAD SHARE AUTOMATION FOR ALL MAIN GENERATORS._x001C_
Condition: Unknown
Due 30 January 2002
Resolved 10 February 2004
Electrical
Issued 6 April 2001 Resolved
DEMONSTRATE AUTOMATION ALARMS/TRIPS FOR #2 MAIN GENERATOR_x001C_
Condition: Unknown
Due 30 January 2002
Resolved 10 February 2004
Electrical
Issued 6 April 2001 Resolved
DEMONSTRATE PROPER BLACKOUT OPS FOR #1 GEN(AUX).
Condition: Unknown
Due 30 January 2002
Resolved 10 February 2002
Lifesaving
Issued 27 February 2001 Resolved
Install handrails that comply with Code of Federal Regulations Title 46, Part 92.25-5 to the deck weather decks that were formerly designated as a Helicopter Facility. Install to satisfaction of USCG Marine Inspector no later than March 13, 2001._x001C_
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Documentation
Issued 27 February 2001 Resolved
Modify the vessels Fire Control Plans to indicate weather decks where a Helicopter Facility was formerly located. Correct to satisfaction of USCG Marine Inspector no later than March 13, 2001._x001C_
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Lifesaving
Issued 1 February 2001 Resolved
PROVE PROPER OPERATION OF LIFE BOAT DAVIT'S RAM ASSIST TO SATISFACTION OF USCG MARINE INSPECTOR._x001C_
Condition: Unknown
Due 1 February 2001
Resolved 2 February 2001
Construction/Loadline
Issued 27 October 2000 Resolved
Provide ballast tanks 6-317-1 & 6-317-2 gas free for inspection. Vessel is prohibited from sailing until ballast tanks have been inspected to the satisfaction of attending Marine Inspector.
Condition: Unknown
Due 1 November 2000
Resolved 3 November 2000
Construction/Loadline
Issued 27 October 2000 Resolved
Provide current analysis report for the clay from all four fixed ballast tanks or provide original test coupon for tank 8-251-2 for inspection. (Chain to original coupons wasted trough and original test coupons lost in clay). Correct prior to 30Nov00._x001C_
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Lifesaving
Issued 27 October 2000 Resolved
Renew the Life Boat Falls for Life Boats 1-4 and make ready for load test required by 46CFR199.190 AND 46CFR199.45._x001C_
Condition: Unknown
Due 30 January 2001
Resolved 2 February 2001
Engineering
Issued 27 October 2000 Resolved
Prepare the #1 AUX Boiler for a Hydro to 1.25 the MAWP and a fireside inspection. Boiler shall not be operated until Hydro and fireside inspection has been completed to the satisfaction of attending Marine Inspector._x001C_
Condition: Unknown
Due 30 October 2000
Resolved 22 November 2000
Navigation
Issued 1 May 2000 Resolved
Complete examination of the vessel's rudder IAW 46 CFR 61.20-23. Any foundworn or not within wear limits must be renew or repaired.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Lifesaving
Issued 1 May 2000 Resolved
Replace No. 4 Lifeboat Boat falls. Falls must be within proper length.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Engineering
Issued 1 May 2000 Resolved
Complete examination of shaft bearing clearances IAW 46 CFR 61.20-23. Any found worn or not within tolerances must be renew or repaired.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 1 May 2000 Resolved
Complete ISE. Make all remaining tanks be ready for inspection.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 1 May 2000 Resolved
Complete examination of all seachest and sea valves remaining on the list during UWILD. Any valves found damaged or worn are to be renew or replaced.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Lifesaving
Issued 3 March 2000 Resolved
Provide evidence that lifeboat falls are of sufficient length to meet 46CFR199.153(d).
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Construction/Loadline
Issued 3 March 2000 Resolved
Prove proper operation of water tight door to shaft alley.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Documentation
Issued 3 March 2000 Resolved
Complete UWILD examination to the satisfaction of attending CG Marine Inspector.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Electrical
Issued 3 March 2000 Resolved
Prove proper operation of Emergency Generator auto start and load transfer,IAW 46CFR112.20-10.
Condition: Unknown
Due 17 March 2000
Resolved 12 March 2000
Documentation
Issued 3 March 2000 Resolved
Complete Internal Structural Examination to the satisfaction of the attending CG Marine Inspector.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Fire Fighting
Issued 11 February 1999 Resolved
Prove proper operation of the cargo hold gas detection system. (part of thesmoke detection system)
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 11 February 1999 Resolved
Propve proper operation of the no. 4 lifeboat fall brake. Under 100% load, brake slips.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 5 April 1998 Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF 15 PPM OILY WATER SEPARATOR (OWS) FOR THE MACHINERY SPACE.
Condition: Unknown
Due 5 April 1998
Resolved 5 April 1998
Navigation
Issued 5 April 1998 Resolved
REPAIR GYROCOMPASS REPEATER LOCATED ON STARBOARD BRIDGE WING.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Lifesaving
Issued 5 April 1998 Resolved
DEMONSTRATE THAT THE ACCESS DOOR TO THE CO2 ROOM CAN BE OPENED BY ONE PERSON. IN THE EXISTING CONDITION IT IS NOT POSSIBLE FOR TWO PEOPLE TO OPEN THE DOOR. IT APPEARS THAT THIS CONDITION IS CAUSED BY AN AIR IMBALANCE.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Construction/Loadline
Issued 14 February 1997 Resolved
VESSEL MAY NOT LOAD CARGO UNTIL APPROVED MODIFICATIONS TO THE BILGE SYSTEM MOV'S ARE MADE AND INSPECTED TO THE SATISFACTION OF THE LOCAL OCMI. THE MOV'S MUST REMAIN ACCESSABLE TO THE CREW AT ALL TIMES UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.