Records from 1983 to 2005. Most recent: inspection, 7 October 2005.
Inspection history · 93
7 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2509847
21 September 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2546030
12 May 2005
Hull Examination · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2348988
1 June 2004
MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2085352
20 January 2004
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1988963
26 August 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1887904
21 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1783523
21 April 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1774121
5 March 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1755929
12 February 2003
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1771135
28 January 2003
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1736621
13 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1661061
6 June 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1627105
13 May 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1614515
4 September 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1072684
4 April 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418888
23 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1052635
11 July 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1051576
10 July 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1051684
27 June 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 819486
20 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053314
10 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050348
5 May 2000
Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1417057
3 April 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1047587
8 April 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441482
2 October 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806646
11 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 3578
24 April 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465959
9 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788098
18 February 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447801
19 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 57639
9 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121777
7 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121630
4 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776699
28 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781245
23 April 1997
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1404360
10 April 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1105151
1 April 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1101458
8 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765091
25 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092999
23 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 205004
4 June 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1090598
31 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 759188
24 May 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447589
11 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 204201
12 February 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 876307
16 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 112643
16 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 145395
1 June 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 885945
6 May 1995
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444977
20 January 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 868353
10 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 882893
9 January 1995
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1424037
14 December 1994
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840943
2 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 20583
14 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867352
21 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1179838
9 September 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428384
6 October 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1136544
28 September 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1154135
20 September 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 962813
9 September 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442055
29 April 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1159086
26 April 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370603
21 August 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362649
18 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 131373
2 April 1992
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1269859
24 October 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1249619
12 September 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1252544
16 July 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 938953
11 July 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 668424
27 June 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1230763
19 June 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 896970
25 September 1990
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1239181
19 September 1990
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 928205
7 April 1990
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1222818
3 November 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1007625
20 September 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888553
12 September 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887512
12 October 1988
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1200949
2 May 1988
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1352706
29 January 1988
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1324573
11 September 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1315769
15 October 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011293
24 September 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007956
23 September 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010259
24 January 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986129
24 January 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1306072
12 November 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999682
13 September 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991611
25 September 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 978994
11 September 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 978992
15 September 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970685
Construction/Loadline › Structures
Issued 21 April 2003
Resolved
Make permanent repairs to wasted (red hand) deck plating in mud pit room. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Due 21 May 2003
Resolved 19 May 2003
Resolution: Rcvd fax from OIM, [name withheld], that the above item was repaired during Phase II of the drydock.
Communications › Alarms/Indicators
Issued 21 April 2003
Resolved
Ensure general alarm is detected in the shaker space. Recommend installing audible or visual alarm. LEGACY COMPONENT DESC: General Alarm
Due 21 May 2003
Resolved 19 May 2003
Resolution: Recieved fax from OIM, [name withheld], that the above item was corrected during Phase II of the drydock.
Construction/Loadline › Hull
Issued 12 February 2003
Resolved
Complete Phase 2 of SEILODD.
Action required: 705 - Other - as specified
Resolved 30 June 2003
Accommodation/Occupational Safety › Potable Water System
Issued 13 May 2002
Resolved
Repair or replace pressurized hot water heater, mainspace engine room port side due to corrosion and holed. LEGACY COMPONENT DESC: Water Heater
Condition: Unknown
Due 13 June 2002
Resolved 6 June 2002
Pollution Prevention/Response › Prevention Equipment
Issued 13 May 2002
Resolved
Crop and renew to good steel two sewage lines in tool room stbd bow. Holed and improper repairs. LEGACY COMPONENT DESC: Sewage System Piping
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 6 June 2002
Unknown
Issued 5 May 2000
Resolved
Conduct inspection of pressure vessels during Phase II SEILODD.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Construction/Loadline
Issued 5 May 2000
Resolved
In preload #2 where face of bottom long has been cut away add reinforcementplate.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 5 May 2000
Resolved
As required, renew bolts on reach rod packing boxes.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Lifesaving
Issued 5 May 2000
Resolved
Install caps on eye wash station at cement room.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Unknown
Issued 5 May 2000
Resolved
Conduct Phase II SEILODD.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Construction/Loadline
Issued 18 February 1998
Resolved
Conduct NDE of leg-to-can critical connections. Submit dive video and diver's report to [name withheld] to be conducted to the satisfaction of the attending marine inspector or class surveyor.
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Construction/Loadline
Issued 18 February 1998
Resolved
In void tank No.3, renew guides on dump valve body #3 and renew valve diskson dumps #3, 5, and 7.
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Construction/Loadline
Issued 18 February 1998
Resolved
Crop and renew bilge pipe located in compressor room bilge well, approximately 12-inches, to flange connection where wasted.
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Construction/Loadline
Issued 18 February 1998
Resolved
Guage bilge well plating at mid and lower sections at 3-6-9-12 o'clock positions, located in barite P-tank room. Provide report to [name withheld].
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Construction/Loadline
Issued 18 February 1998
Resolved
In void tank No.11, ultrasonically test outboard side stiffeners and crop and renew, as original, if wastage exceeds 25%. Provide report to [name withheld] and renew horizontal stiffeners #1-4 to left of ladder on bulkhead. Crop and renew, as original, landing platform.
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Construction/Loadline
Issued 18 February 1998
Resolved
Make ready for inspection, void tank No.6 and master-dump valve, to the satisfaction of the attending marine inspector or class surveyor.
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Lifesaving
Issued 23 April 1997
Resolved
PROVE PROPER OPERATION AND OR MAINTENANCE OF BOTH LIFEBOAT RELEASE MECHANISM.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Fire Fighting
Issued 23 April 1997
Resolved
ENSURE ALL FIRE NOZZLE SPUD CHAINS ARE FIXED TO NOZZLES.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Electrical
Issued 23 April 1997
Resolved
PROVE PROPER OPERATION OF #5 EMD UPON COMPLETION OF INSTALLATION, IE; OVERSPEED, LOW L/O SHUTDOWN, HI-TEMP ALARMS.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Fire Fighting
Issued 23 April 1997
Resolved
PROVE PROPER OPERATION OF FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Electrical
Issued 23 April 1997
Resolved
PROVE PROPER OPERATION OF PURGE AIR ALARMS (AUDIBLE AND VISUAL) ON RIG FLOOR AT DRILLERS CONSOLE (LOWER UNIT).
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Fire Fighting
Issued 23 April 1997
Resolved
PROVIDE GENERAL QUARTERS ALARMS IN AREA BEHIND FIRE PUMP AND SEWAGE ROOM.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Electrical
Issued 23 April 1997
Resolved
PROVE PROPER OPERATION OF OVERSPEED AND SHUT-DOWNS ON STAND-BY GENERATOR.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Construction/Loadline
Issued 23 April 1997
Resolved
IDENTIFY BILGE PIPING VALVES AT MANIFOLD LOCATION.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Fire Fighting
Issued 23 April 1997
Resolved
CONDUCT FIRE AND BOAT DRILLS TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR. ENSURE INVENTORY OF ALL LIFEBOAT GEAR.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Lifesaving
Issued 23 April 1997
Resolved
PROVE PROPER OPERATION OF THREE AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 23 May 1997
Resolved 12 May 1997
Lifesaving
Issued 24 May 1996
Resolved
PROVIDE RATIONS IN STARBOARD 36-MAN LIFEBOAT OR CHANGE ROUTE TO "OCEANS, NOT ON AN INTERNATIONAL VOYAGE."
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Accommodation/Occupational Safety
Issued 24 May 1996
Resolved
RENEW PRESSURE RELIEF VALVES ON POTABLE AND SANITARY WATER TANKS WITH ASME CODED VALVES RATED AT OR BELOW 100 PSI.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Construction/Loadline
Issued 6 May 1995
Resolved
SUBMIT TO PATMS--ABS REPORTS OF REPAIRS/HYDRO TESTING OF STEEL REPAIRS TO HULL AND DECK.
Condition: Unknown
Due 6 June 1995
Resolved 25 September 1995
Lifesaving
Issued 6 May 1995
Resolved
PREFORM LIFE BOAT DRILLS PRIOR TO NEXT DRILLING OPERATIONS. SUBMIT REPORT LOG AND O.I.M. LETTER TO PATMS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Lifesaving
Issued 6 May 1995
Resolved
PERFORM WEIGHT TEST OF STARBOARD DAVIT LIFE RAFT LAUNCH SYSTEM.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Deck/Cargo
Issued 6 May 1995
Resolved
SUBMIT TO PATMS--ABS CRANE INSPECTION REPORTS.
Condition: Unknown
Due 6 June 1995
Resolved 25 September 1995
Documentation
Issued 6 May 1995
Resolved
SUBMIT TO PATMS--ABS AND NDT REPORTS OF TESTS AND REPAIRS PREFORMED ON ALL THREE (3) SPUD CAN CRITICAL CAN CONNECTIONS.
Condition: Unknown
Due 6 June 1995
Resolved 25 September 1995
Construction/Loadline
Issued 6 May 1995
Resolved
REPAIR NO.2 BILGE PUMP SEAL LOCATED IN MOTOR ROOM.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Documentation
Issued 10 January 1995
Resolved
RESUBMIT REVISED FIRE CONTROL PLAN OF SUBJECT VESSEL AS PER LTR FROM MSO PATMS DTD 20OCT95.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Lifesaving
Issued 9 September 1994
Resolved
Renew drinking water in both lifeboats. Current packs expire in November of 1994, but many are leaking._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1994
Resolved 21 September 1994
Lifesaving
Issued 9 September 1994
Resolved
Provide three additional line throwing guns of the same type presently onboard. (Paines Wessey speedline 25D one-time disposable type._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1994
Resolved 21 September 1994
Documentation
Issued 9 September 1994
Resolved
Provide proof of CG approved construction portfolio or submit existing portfolio for approval._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 9 September 1994
Resolved
Replace all Non- Coast Guard approved ring buoys with CG approved ones and place on location as required by 46CFR108.515_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Documentation
Issued 9 September 1994
Resolved
Amend existing fire control plan to show location of lifesaving equipment; ie. lifeboats, rafts, ringbuoys, line throwing gun, flares, PFD storage, portable radio stowage etc. Reproduce amended plan (reduce if necessary) and mount under glass or laminate. Post in an area accessible to all hands
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 28 September 1993
Resolved
CONDUCT A FIRE AND BOAT DRILL TO INCLUDE OPERATION OF BOTH LIFEBOATS IN WATER AND OPERATION OF SPRINKLER SYSTEMS.
Condition: Unknown
Due 28 September 1993
Resolved 28 September 1993
Fire Fighting
Issued 9 September 1993
Resolved
CROP AND RENEW SECTION OF FIREMAIN PIPING IN HALLIBURTON ROOM IN AREA OF SOFT PATCH.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Electrical
Issued 9 September 1993
Resolved
PROVIDE PROPER SIZED BATTERY BOXES IN MOTOR ROOM FOR 24 VOLT CONTROL.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Electrical
Issued 9 September 1993
Resolved
PROVE OPERATION OF DRILLER KILLER AIR PURGE LOSS ALARM AT DRILLER'S CONSOLE.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Lifesaving
Issued 9 September 1993
Resolved
CONDUCT A FIRE AND BOAT DRILL TO INCLUDE OPERATION OF BOTH LIFEBOATS IN WATER AND OPERATION OF SPRINKLER SYSTEMS.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Accommodation/Occupational Safety
Issued 9 September 1993
Resolved
RENEW PRESSURE RELIEF VALVES ON SANITARY AND POTABLE WATER TANKS WITH ASME APPROVED VALVES RATED AT OR LESS THAN 100 PSI.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Lifesaving
Issued 9 September 1993
Resolved
PROPERLY MARK DAVIT ARM AND CABLE AND BRAKE RELEASE HANDLE TO CORRESPOND WITH INSTRUCTION PLACARDS FOR DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Accommodation/Occupational Safety
Issued 9 September 1993
Resolved
RENEW THREE (3) HOT WATER HEATER RELIEF VALVES WITH PRESSURE/TEMPERATURE RELIEFS RATED AT OR LESS THAN 100PSI/210 DEGREES F.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Electrical
Issued 9 September 1993
Resolved
PROVE OPERATION OF MUD PIT ROOM EXHAUST FAN FLOW SWITCH ALARM. MUST BE WIRED INDEPENDENT OF FAN MOTOR.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Lifesaving
Issued 9 September 1993
Resolved
REPLACE KINKED CABLE FOR STBD DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Engineering
Issued 9 September 1993
Resolved
RENEW FUEL OIL SUPPLY AND RETURN FLEXIBLE HOSES ON ALL FOUR (4) GENERATORS IN ACCORDANCE WITH 46 CFR 56.60-25(c). (USCG APPROVED HOSES)
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Accommodation/Occupational Safety
Issued 9 September 1993
Resolved
MOUNT OPERATING INSTRUCTIONS FOR MARINE SANITATION DEVICE (SEWAGE SYSTEM) TO INCLUDE STORAGE AND HANDLING OF CHEMICALS, SAFETY PRECAUTIONS, AND CHEMICAL ADDITIVE INSTRUCTIONS IAW 33 CFR 159.59
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Accommodation/Occupational Safety
Issued 26 April 1993
Resolved
REPAIR CROSS BRACE ON LADDER IN #8 PRELOAD TANK.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Accommodation/Occupational Safety
Issued 26 April 1993
Resolved
MAKE PERMANENT REPAIRS TO ESCAPE LADDERS ON INSIDE OF LEGS (SECTION MISSINGON STBD LADDER).
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Documentation
Issued 26 April 1993
Resolved
MAKE VESSEL AVAILABLE FOR UNDERWATER PORTION (LEG/MAT CONNECTIONS, ETC.) OFSPECIAL EXAM IN LIEU OF DRYDOCK.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Construction/Loadline
Issued 26 April 1993
Resolved
MAKE THE MAIN DUMP VALVE AND THE SHAKER DUMP VALVE AVAILABLE FOR INTERNAL INSPECTION (ITEMS #1 AND #2 SHALL BE COMPLETED WITHIN 90 DAYS OR AT NEXT RIG MOVE, WHICHEVER IS SOONER).
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Electrical
Issued 12 September 1991
Resolved
REPAIR EXPLOSION PROOF FITTING IN JUNCTION BOX LOCATED IN OVERHEAD BEHIND FWD SHALE SHAKER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Electrical
Issued 12 September 1991
Resolved
REHANG ALL LIGHTS IN OVERHEAD OF MUDPIT AS NEEDED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Electrical
Issued 12 September 1991
Resolved
INSTALL NON-CORROSIVE LINERS FOR BOTH BATTERY BOXES LOCATED OUTSIDE STAND- BY GENERATOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Fire Fighting
Issued 12 September 1991
Resolved
PROVIDE ONBOARD THE VESSEL 8 APPROVED FIRE HOSES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Electrical
Issued 12 September 1991
Resolved
PROVE THE PROPER OPERATION OF THE LOW LUBE OIL PRESSURE SHUTDOWN ON THE _x001C_ #3 & #4 DIESEL GENERATORS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Electrical
Issued 12 September 1991
Resolved
PROVIDE TWO AIR RECEIVER RELIEF VALVES AND TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Documentation
Issued 12 September 1991
Resolved
PROVIDE MSO PORT ARTHUR WITH A COPY OF FIRE SERVICING REPORT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Lifesaving
Issued 12 September 1991
Resolved
MAKE PRESSURE VESSELS AVAILABLE FOR INTERNAL EXAMINATION BY A MARINE INSPECTOR AT COMPLETION OF PRESENT DRILLING OPERATION. THIS DEFICIENCY SHALL BE CLEARED PRIOR TO DEPARTING [name withheld], TEXAS INSPECTION ZONE._x001C_
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Fire Fighting
Issued 12 September 1991
Resolved
PROVIDE PROOF OF SERVICING OF 24 A:B:C TYPE PORTABLE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Construction/Loadline
Issued 12 September 1991
Resolved
PROVE PROPER OPERATION OF THE BILGE SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Unknown
Issued 27 June 1991
Resolved
PROVIDE WIEGHT TEST FOR LIFERAFT DAVIT NO.2 IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 27 June 1991
Resolved 27 June 1991
Unknown
Issued 27 June 1991
Resolved
PROVIDE SATISFACTORY DOCUMENTATION FOR CERTIFICATION OF WIRE ROPE USED IN BOTH LIFERAFT DAVITS (NO.1 AND 2).
Condition: Unknown
Due 27 June 1991
Resolved 27 June 1991
Fire Fighting
Issued 19 September 1990
Resolved
IN THE PRESENCE OF A COAST GUARD INSPECTOR CONDUCT FIRE & ABANDON DRILLS.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Lifesaving
Issued 19 September 1990
Resolved
REPLACE AND PROVE PROPER OPERATION OF LIMIT SWITCHES ON PORT LIFEBOAT WINCH.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Construction/Loadline
Issued 12 September 1989
Resolved
REPAIR/RENEW THE WORN VALVE SEAT FOR THE SKIMMER TANK IN THE BILGE SYSTEM.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Navigation
Issued 12 September 1989
Resolved
INSTALL PRE-FOCUSED CLEAR BULBS IN THE PORT AND STARBOARD RUNNING LIGHTS AND THE STERN RUNNING LIGHT.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Lifesaving
Issued 12 September 1989
Resolved
RECHARGING AIR BOTTLES IN 36 MAN CAPSULE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
INSTALL EMBARKATION LIGHTS AT ALL LIFERAFT STATIONS.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Fire Fighting
Issued 12 September 1989
Resolved
HYDRO AIR BOTTLES AS NEEDED FOR ALL FIREMANS OUTFITS
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Fire Fighting
Issued 12 September 1989
Resolved
REPAIR GAS DETECTOR SYSTEM.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Fire Fighting
Issued 12 September 1989
Resolved
HYDRO CO2 15LB IN GALLEY
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
RENEW THE TYPE SO CABLE ON THE SWACO UNIT ON THE DRILL FLOOR BY THE DOG HOUSE WITH APPROVED CABLE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
CHECK AND POUR ALL THE EYS FITTINGS ON THE DRILL FLOOR ENSURING THAT THE OUTER INSULATION HAS BEEN STRIPPED BACK.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
INSTALL A LOSS OF PURGE AUDIBLE OR VISUAL ALARM ON THE MARTIN DECKER WORK WATCHER IN THE DOG HOUSE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
POUR THE SHALE SHAKER MOTOR EYS FITTINGS ENSURING THAT THE OUTER INSULATIONOF THE CABLE IS STRIPPED BACK.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
CHECK AND POUR ALL EYS FITTINGS IN THE MUDPIT ROOM ENSURING THAT THE OUTER CABLE INSULATION IS STRIPPED BACK.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
RENEW THE TYPE SO CABLE ON THE BRAKE COOLING TANK PUMPS WITH APPROVED CABLE
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
RENEW THE RECEPTICLE BY THE SHALE SHAKER UNITS BY THE DRILL FLOOR SKID BEAMWITH AN APPROVED TURN-LOCK TYPE FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
RENEW THE 24V MAIN DIESEL ENGINE GOVERN OR BATTERIES.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 11 September 1987
Resolved
MAKE READY FOR TEST THE EMERGENCY SHUTDOWNS FOR THE FOUR GENERATORS (OVER- SPEED TRIPS, REVERSE POWERE RELAYS, LOW LUBE OIL PRESSURE TRIP, AND HIGH COOLING WATER TEMPERATURE ALARM). NOTIFY OUR OFFICE ONCE THE ABOVE TESTS CAN BE VERIFIED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Construction/Loadline
Issued 23 September 1986
Resolved
MAKE THE DOORS TO THE MUD PITS VAPOR TIGHT.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Navigation
Issued 23 September 1986
Resolved
PROVE PROPER OPERATION OF THE FOG HORN; HORN IS NOT PRODUCING THE CORRECT DECIBEL LEVEL.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Documentation
Issued 23 September 1986
Resolved
PROVIDE ON BOARD AN OIL TRANSFER PROCEDURE PER 33 CFR 155.720/760.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
PROVIDE A ROTATING LIGHT TO INDICATE A GENERAL ALARM IN THE GENERATOR ROOM DUE TO EXCESSIVE NOISE LEVEL.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
MAKE OPERATIONAL THE OVERSPEED TRIPS ON ALL FOUR (04) GENERATOR SETS. OVERSPEEDS SHALL BE SET TO A SPEED NOT TO EXCEED 115% OF THE RATED ENGINE RPM.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
SET THE REVERSE CURRENT DEVICES ON GENERATOR SETS 1,2 & 4 TO TRIP AT APPROXIMATELY 58HZ.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Deck/Cargo
Issued 23 September 1986
Resolved
PROVIDE MANHOLE COVER DOG THE SAME TYPE AS ON ALL OTHERS. BULK TANK #4 CEMENT.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
REPAIR OR REPLACE THE DAMAGED FAN GUARD ON THE POTABLE WATER PUMP ELECTRIC MOTOR.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Accommodation/Occupational Safety
Issued 23 September 1986
Resolved
PROVIDE A RELIEF VALVE ON THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
PROVIDE REMOTE SHUTDOWNS FOR THE FUEL OIL PURIFIER AND FUEL OIL TRANSFER PUMP PER 46 CFR 111./80-13, OLD "J".
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
PROVIDE "CHICO" IN THE FOLLOWING EYS FITTINGS, LIGHT FIXTURES, MUD PITS & "DOG" HOUSE.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
PROPERLY MOUNT MOTOR CONTROLLER, PORT PUMP, FOR MUD PIT AND PROVIDED REQUIRED BOLT IN THE COVER PLATE.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Electrical
Issued 23 September 1986
Resolved
MAKE OPERATIONAL THE AIR PURGE ALARM FOR THE DRILLER'S CONSOLE.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Accommodation/Occupational Safety
Issued 13 September 1985
Resolved
REPLACE THE RELIEF VALVES TO THE MOTOR ROOM AIR RECEIVER TANKS WITH ONES OF150 OR LESS SET PRESSURE 46CFR54.15 NVC4-78
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Accommodation/Occupational Safety
Issued 13 September 1985
Resolved
OPEN THE DRILL FLOOR AIR RECEIVER FOR COAST GUARD INSPECTION. 46CFR107.231
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Fire Fighting
Issued 13 September 1985
Resolved
SUBMIT FOR APPROVAL FIRE CONTROL PLAN PER 46 CFR 107.305 (VV).
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Fire Fighting
Issued 13 September 1985
Resolved
PROVIDE THE FIRE PROTECTION EQUIPMENT RECORD FOR EXAM PER 46 CFR 109.435.
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Lifesaving
Issued 13 September 1985
Resolved
REPLACE THE FALLS ON THE STARBOARD LITEBOAT LAST REPLACED 1979, PER WHITTAKER MAINTENANCE MANNUAL.
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Navigation
Issued 13 September 1985
Resolved
PROVIDE ONBOARD ONE (1) ADDITIONAL NAVIGATION DAY SHAPE BALL. (COLREGS)
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Documentation
Issued 13 September 1985
Resolved
SUBMIT FOR APPROVAL CLASSIFIED LOCATION PLAN PER 46 CFR110.25-1(K).
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Lifesaving
Issued 11 September 1984
Resolved
REFILL AIR TANKS (ON 50) MAN ESCAPE CAPSULE TO 2950 PSIG.
Condition: Unknown
Due 11 September 1984
Resolved 11 September 1984
Fire Fighting
Issued 11 September 1984
Resolved
PROVIDE SIX (6) ADDITIONAL 1/2"X50' FIRE HOSES.
Condition: Unknown
Due 11 September 1984
Resolved 11 September 1984