MAURY USCG vessel records
← All vessels

IGUANA II

IGUANA II is a 1981 tank barge. The Coast Guard has recorded 115 inspections since 1983, most recently in April 2010, along with 77 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2004 and 2009.

Records from 1983 to 2010. Most recent: inspection, 7 April 2010.

Built
1981
Last inspected
7 April 2010
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 7 April 2010
…with no type recorded41
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 28 calendar years (1983–2010)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

228652
Flag
UNITED STATES
Maury page id
psix-228652

Documentation record

Tonnage as PSIX records it11083 - Regulatory (Subpart C or D), Net Ton
8314 - Convention (Subpart B), Net Ton
23000 - Dead Weight, Ton
11295 - Regulatory (Subpart C or D), Gross Ton
12271 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

Inspection history · 115

7 April 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3711133
6 August 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3557028
4 August 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3558198
10 June 2009 MTSA Verification · Deficiency Check · Administrative Inspection · Ballast Water Examination · Periodic Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3500470
17 September 2008 Ballast Water Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3326620
4 April 2008 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3177358
3 April 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3176955
24 March 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3170989
3 October 2007 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3072197
26 September 2007 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3066797
19 July 2007 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3020273
1 February 2007 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2865323
15 January 2007 Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2857172
3 October 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2792857
22 June 2006 COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2687687
9 June 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2674760
25 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2633129
29 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2542601
23 August 2005 MARPOL Annex I Examination · Re-Inspection · MTSA Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2468804
5 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2350200
22 November 2004 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2245743
29 October 2004 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2231199
18 October 2004 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2224498
23 September 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2203360
8 July 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2162212
4 June 2004 MTSA Verification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2098172
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979844
26 August 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1887885
6 August 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1868404
17 April 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1775727
19 December 2002 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1721269
30 August 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1668677
1 August 2002 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1657238
12 July 2002 MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1647814
20 June 2002 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1633901
6 May 2002 Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1613466
26 April 2002 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1609746
30 January 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1482630
21 December 2001 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1473622
17 October 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1074185
26 July 2001 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1467786
24 July 2001 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1070194
9 October 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 74587
9 October 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1415472
28 July 2000 Re-Inspection · MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1444419
16 November 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441584
28 July 1999 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1459546
2 February 1999 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1125854
30 October 1998 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 804831
10 July 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 84621
21 May 1998 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1449064
12 May 1998 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1125376
22 December 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 667082
15 December 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 781437
6 December 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 124771
6 December 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 166758
6 December 1997 Damage Survey
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 776307
2 December 1997 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1116005
2 September 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1119947
12 June 1997 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1383587
2 June 1997 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 773654
29 January 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1368033
2 June 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1084957
16 May 1996 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1182977
9 April 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1456365
23 December 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 485991
29 September 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 462030
16 June 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 503876
26 April 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1360093
13 February 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 513233
14 October 1994 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1174143
15 April 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1434124
3 December 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 537083
2 June 1993 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1387360
21 May 1993 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1143861
2 April 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 357332
15 December 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1140619
13 November 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 456097
20 August 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 503161
30 June 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 953578
6 May 1992 COI Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1256604
29 April 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 168328
13 February 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 521750
12 February 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 137649
29 January 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 953914
25 June 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1221087
13 May 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1225250
3 April 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 909609
4 February 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 508029
26 June 1990 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 490648
14 May 1990 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1219377
16 February 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 518410
22 January 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1222614
10 August 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 493988
17 May 1989 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 969249
28 April 1989 Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1202479
11 January 1989 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 481771
29 July 1988 Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1037566
7 July 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 436551
28 January 1988 MARPOL Annex II Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1019957
21 October 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 498217
19 June 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 317006
4 June 1987 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308329
14 March 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 529825
2 October 1986 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1007336
18 August 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 466052
2 February 1986 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 438396
16 October 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 446215
10 October 1985 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 986546
22 May 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1287313
3 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 301231
17 January 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283710
6 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283782
2 December 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971444
30 November 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971060

Deficiency record · 77

Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 11 June 2009 Resolved
Provide proof that the vessel has a closed gauging arrangement where the liquid level in the tank can be determined for the full range of liquid levels in the tank; where the HIGH LEVEL & OVERFILL LEVEL audible and visual alarms are not lower than the percent capacities IAW 46 CFR 39.20-7.
Action required: 705 - Other - as specified
Due 11 July 2009
Resolved 9 July 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 June 2009 Resolved
Provide proper markings to the vessel's Cargo piping.
Action required: 705 - Other - as specified
Due 11 July 2009
Resolved 7 July 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 10 June 2009 Resolved
Provide "EMERGENCY SHUTDOWN STATION" sign at the emergency shutdown station IAW 46 CFR 153.296.
Action required: 705 - Other - as specified
Due 11 July 2009
Resolved 7 July 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 June 2009 Resolved
Provide proof that all cargo system/piping gauges have been either renewed or calibrated within the last 12 months.
Action required: 705 - Other - as specified
Due 11 July 2009
Resolved 7 July 2009
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 10 June 2009 Resolved
Provide proof that fuel oil transfer system (fixed and flexible; from barge to shore and barge to tug) meets the requirements of 33 CFR 155 & 156; to be completed PRIOR TO CONDUCTING ANY FUEL OIL TRANSFERS.
Action required: 703 - Prior to bunkering operations
Due 11 July 2009
Resolved 13 June 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 June 2009 Resolved
Provide machinery guard to the aft (at sea) 125 KW generator.
Action required: 705 - Other - as specified
Due 11 July 2009
Resolved 7 July 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 17 September 2008 No resolution recorded
Several sections of dpiing and valve handles were noted to be excessively worn. Required renewal by 06DEC09
Condition: Improper/Lack of Maintenance
Due 6 December 2009 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 17 September 2008 Resolved
Vessel's SMPEP does not have USCG approval letter onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2008
Resolved 18 September 2008
Resolution: Received copies of valid approval ltrs for SOPEP,SMPEP, & VRP.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 September 2008 Resolved
EAP information not avialable in crew common area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2008
Resolved 18 September 2008
Resolution: Received confirmation from vsl master of required EAP contact information posted in crew common area.
Deck/Cargo › Cargo Heating › General
Issued 19 July 2007 Resolved
Master/Barge Rep are to provide proof or show operation of boiler for thermal fluid heater.
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 3 October 2007
Resolution: Received 3rd party report stating the boiler for the thermal fluid heater is operating properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2006 Resolved
remove or repair loose wiring in generator room.
Condition: Improper/Lack of Maintenance
Due 16 July 2006
Resolved 13 July 2006
Resolution: Cleared
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Air Cleaner
Issued 22 June 2006 Resolved
Secure air intake bracket.
Condition: Improper/Lack of Maintenance
Due 16 July 2006
Resolved 13 July 2006
Resolution: Secured air intake
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 June 2006 Resolved
Replace all UV damaged line on ring lifebouys
Condition: Improper/Lack of Maintenance
Due 16 July 2006
Resolved 13 July 2006
Resolution: Replace line on liferings
Lifesaving › Immersion Suits › Retroreflective Material
Issued 22 June 2006 Resolved
Replace worn retro tape on immersion suits.
Condition: Improper/Lack of Maintenance
Due 16 July 2006
Resolved 13 July 2006
Resolution: Replace retroflective tape
Construction/Loadline › Structures › Door
Issued 22 June 2006 Resolved
Missing hinge pin keepers on watertight doors
Condition: Improper/Lack of Maintenance
Due 16 July 2006
Resolved 13 July 2006
Resolution: Replace cotter pins on doors
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 June 2006 Resolved
Post correct donning placard for type of lifejackets carried onboard
Condition: Improper/Lack of Maintenance
Due 16 July 2006
Resolved 13 July 2006
Resolution: Purchased new lifejackets
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 22 June 2006 Resolved
Needs to paint background and side screens on navigation lights mat black
Condition: Improper Installation
Due 16 July 2006
Resolved 13 July 2006
Resolution: Painted mat black
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 19 October 2004 Resolved
Properly stencil cargo piping.
Due 2 November 2004
Resolved 29 October 2004
Resolution: Received photos verifying the Cargo Piping is properly marked. Faxed CG-835 to [phone withheld] clearing the deficiency. MSO Charleston issued the deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 19 October 2004 Resolved
[name withheld] Shutdown on #5 cargo pump.
Due 2 November 2004
Resolved 12 March 2021
Resolution: Received photos verifying the Emergency Shutdown on #5 Cargo Pump is properly marked. Faxed CG-835 to [phone withheld] clearing the deficiency. MSO Charleston issued the deficiency.
Electrical › Electric Generation Source (service)
Issued 6 August 2003 Resolved
Replace missing data plate on #1 generatorl
Due 25 August 2003
Resolved 26 August 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 6 August 2003 Resolved
Replace missising bowls under fuel filters on #2 generator and the at sea generator.
Due 25 August 2003
Resolved 26 August 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 6 August 2003 Resolved
Make permanent connection from halon bottle hose to paint locker. LEGACY COMPONENT DESC: Piping
Due 25 August 2003
Resolved 26 August 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 6 August 2003 Resolved
Replace/repair broken halon discharge nozzle in lower stbd knock. LEGACY COMPONENT DESC: Nozzle
Due 25 August 2003
Resolved 26 August 2003
Deck/Cargo › Cargo Stowage
Issued 1 August 2002 Resolved
Tank domes on #1 port and #4 port cargo tanks are leaking air around gasket sealing surface. LEGACY COMPONENT DESC: Dome tops
Due 22 August 2002
Resolved 21 August 2002
Resolution: All conditions met.
Engineering › Compressed Air System (control)
Issued 1 August 2002 Resolved
Service air line under #3 pump room is wasted. Needs to be cut out and renewed. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 22 August 2002
Resolved 21 August 2002
Resolution: All conditions met.
Construction/Loadline
Issued 1 August 2002 Resolved
P & S battery boxes are wasted. Renew boxes. Due date extended. LEGACY COMPONENT DESC: Deck battery box
Condition: Improper/Lack of Maintenance
Due 13 September 2002
Resolved 17 April 2003
Resolution: Received statement from [name withheld] that the battery boxes have been replaced with new ones.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 1 August 2002 Resolved
Demonstrate proper operation of #1 cargo pump remote shutdown. LEGACY COMPONENT DESC: Cargo Pump
Due 22 August 2002
Resolved 21 August 2002
Resolution: All conditions met.
Electrical › Electric Generation Source (service)
Issued 1 August 2002 Resolved
Demonstrate proper operation of stbd generator and all shutdowns.
Due 22 August 2002
Resolved 21 August 2002
Resolution: All conditions met.
Electrical › Electric Generation Source (service)
Issued 1 August 2002 Resolved
Demonstrate proper operation of port generator shutdowns. Extended from original date of 22 Aug.
Due 29 August 2002
Resolved 29 August 2002
Resolution: Witnessed proper operation of all port generators shutdown and alarms.
Deck/Cargo › Cargo Stowage
Issued 1 August 2002 Resolved
Properly label all cargo tanks. LEGACY COMPONENT DESC: Tank top hatches
Condition: Improper/Lack of Maintenance
Due 22 August 2002
Resolved 21 August 2002
Resolution: All conditions met.
Electrical › Electric Generation Source (service)
Issued 1 August 2002 Resolved
Demonstrate to attending C.G. inspector proper J/W temp scaling of stbd gen nlt 13 Sep. 02
Due 13 September 2002
Resolved 10 September 2002
Documentation › Certificates/Documents
Issued 12 July 2002 Resolved
IOPP was expired. LEGACY COMPONENT DESC: IOPP Certificate
Due 12 July 2002
Resolved 12 July 2002
Resolution: Conducted IOPP survey. Issued new IOPP and notified them that a we would be issueing a Letter of Warning.
Engineering › Compressed Air System (start air)
Issued 6 May 2002 Resolved
Conduct hydrostatic test or internal exam of all pressure vessels as per 46 CFR 61.10. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Unknown
Due 22 June 2002
Resolved 22 June 2002
Resolution: Conducted internal examination. Issued amendment.
Deck/Cargo
Issued 26 July 2001 Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THERMAL FLUID HEATER TO COGNIZANT [name withheld] HEATER INOP DUE TO LEAKING OF AFT TUBE BANK.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Engineering
Issued 9 October 2000 Resolved
INSPECT/REPAIR OUTBOARD BOILER FOR POSSIBLE TUBE LEAKAGE. IF TUBE LEAKAGE IS FOUND, BOILER MUST BE REPAIRED AND RE-HYDROSTATICALLY TESTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 October 2000
Resolved 9 October 2000
Unknown
Issued 9 October 2000 Resolved
RENEW OVERHEAD INSULATION IN THE DECK HOUSE LOCATED ABOVE THE AUXILLIARY BOILERS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 October 2000
Resolved 9 October 2000
Deck/Cargo
Issued 28 July 1999 Resolved
Make permanent repairs to expansion joint on exhaust piping on number 2 cargo pump engine.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 15 December 1997 Resolved
CRACK IN BARGE'S HULL; STBD SIDE, AMIDSHIPS. BARGE IS SINGLE HULLED, CRACKDAMAGED INTEGRITY OF #4 STBD CARGO TANK.
Condition: Unknown
Due 31 January 1998
Resolved 19 December 1997
Construction/Loadline
Issued 6 December 1997 Resolved
Vessel allided with bumper system and dock causing a 3-4" crack in way of #4 starboard cargo tank. Issued one CG-835 to make permanent repairs priorto carring cargo and NLT 07JAN98.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Deck/Cargo
Issued 12 June 1997 Resolved
REPAIR LEAK TO INBOARD COMPRESSOR ENGINE FOR I.G. SYSTEM. UNTIL REPAIRED, AND APPROVED DO NOT USE INBOARD ENGINE. TO BE DONE TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR. TO BE COMPLETED NLT 12JUL97.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Deck/Cargo
Issued 9 April 1996 Resolved
REPAIR AND REFURBISH PRESSURE/VACUUM BULLET VENT VALVES IWO CARGO TANKS 1P,2P, 4P, AND 3S.
Condition: Unknown
Due 8 May 1996
Resolved 6 June 1996
Accommodation/Occupational Safety
Issued 9 April 1996 Resolved
MAKE READY FOR INTERNAL EXAMINATION BY A QUALIFIED MARINED INSPECTOR ALL AIR RECEIVERS ON BOARD (2 IN PORT MACHINERY SPACE AND 1 IN STBD MACHINERY SPACE)
Condition: Unknown
Due 8 May 1996
Resolved 6 June 1996
Fire Fighting
Issued 14 October 1994 Resolved
Provide valid proof of servicing of fixed firefighting system.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 15 April 1994 Resolved
MAKE PERMANENT REPAIRS TO WATERTIGHT DOOR FOR EMERGENCY GEAR LOCKER ON MAINDECK. THESE REPAIRS TO BE DONE AT NEXT DRYDOCK. TEMP REPAIRS ARE TO BE DONE NO LATER THAN 01MAY94.
Condition: Unknown
Due 15 April 1994
Resolved 15 April 1994
Fire Fighting
Issued 15 April 1994 Resolved
PROVE PROPER OPERTION OF CHECK VALVE ON HALON SYSTEM. THESE REPAIRS TO BE DONE AT THE NEXT DRYDOCK.
Condition: Unknown
Due 15 April 1994
Resolved 15 April 1994
Accommodation/Occupational Safety
Issued 21 May 1993 Resolved
MAKE PERMANENT REPAIRS TO WASTED AREAS TO VENT DUST IN GENERATOR ROOM.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Deck/Cargo
Issued 21 May 1993 Resolved
PROVE PROPER OPERATION OF FUEL OIL PUMP ON THERMAL HEATER #80-105.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Deck/Cargo
Issued 21 May 1993 Resolved
PROVE PROPER OPERATION OF AUTOMATION SYSTEM FOR THERMAL HEATER 80-104.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Documentation
Issued 29 January 1992 Resolved
AFTER OBTAINING APPROVAL OF VAPOR RECOVERY SYSTEM AND TRANS. PROCEDURES, REQUEST AN AMENDED CERTIFICATE OF INSPECTION IAW 39.10-13(E)
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Documentation
Issued 29 January 1992 Resolved
PROVIDE A REVISED OIL TRANSFER PROCEDURE COMPYLING W/THE REQUIREMENTS OF 46CFR 39.30-1 AND 33 CFR 155.750
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Deck/Cargo
Issued 29 January 1992 Resolved
PROVIDE APPROVED PLANS FOR VAPOR RECOVERY SYSTEM: ELECTRICAL AND PIPING. COMPLY WITH ALL COMMENTS PRETAINING TO THESE PLANS.
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Deck/Cargo
Issued 3 April 1991 Resolved
PROVIDE PROOF OF HYDROSTATICALLY TESTING OF CARGO PIPING PRIOR TO NEXT LOADING AS REQUIRED BY 33 CFR 156.170
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Deck/Cargo
Issued 3 April 1991 Resolved
MAKE PERMANENT REPAIRS TO #2 TWO PORT ULLAGE COVER DOGS.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Engineering
Issued 3 April 1991 Resolved
PROPERLY MARK EMERGENCY SHUTDOWN MASTER STATION.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Deck/Cargo
Issued 3 April 1991 Resolved
PERMANENTLY MARK (GWL) SAFE WORKING LOAD ON STARBOARD BOOM.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Electrical
Issued 3 April 1991 Resolved
MAKE PERMANENT REPAIRS AND SHOW PROPER OPERATION OF LOW LUBE OIL, HIGH FRESH WATER TEMP, OVERSPEED ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Engineering
Issued 14 May 1990 Resolved
RENEW FUEL FILTER BOWL ON EMERGENCY GENERATOR.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Engineering
Issued 14 May 1990 Resolved
REMOVE ALL PETLOCKS FROM GENERATOR FUEL OIL FILTERS AND INSTALL PLUGS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Documentation
Issued 22 January 1990 Resolved
CREDIT DRYDOCK DUE 04JUN92. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Electrical
Issued 28 April 1989 Resolved
REPAIR FUEL LINE TO #1 S/S GENERATOR.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Accommodation/Occupational Safety
Issued 28 April 1989 Resolved
REPAIR VENT CLOSUREFOR PAINT LOCKER.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
MAKE REPAIRS TO D.C. CABLES CONNECTION SPLICES IN BATTERY BANK COMPARTMENT BY MAKING CONTINUOS RUN OF WIRE OR HAVE CONNECTORS INSIDE A JUNCTION BOX.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
CHECK ALL ELECTRICAL BOXES & PLUG ALL BLANK OPENINGS WHERE EXIST.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Lifesaving
Issued 2 October 1986 Resolved
REPAIR OR REPLACE PORT EMBARKATION LIGHT.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Deck/Cargo
Issued 2 October 1986 Resolved
CLEAN BOTH CARGO MANIFOLD CONTAINMENT BOXES OF EXCESS CARGO.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Deck/Cargo
Issued 2 October 1986 Resolved
PERFORM HYDRO ON CARGO PIPING TO 1.5 TIMES MAWP TO THE SATISFACTION OF THE COGNIZANT [name withheld] 30 DAYS.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
REMOVE BOTH SAFETIES FROM THERMAL HEATING UNITS AND BENCH TEST AND SEAL TO THE SATISFACTION OF THE COGNIZANT OCMI AT DRYDOCKING.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Electrical
Issued 2 October 1986 Resolved
INSTALL CIRCUIT BREAKER OR BLANK IN ELECTRICAL PANEL 3P 122 IN CREW'S MESS.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Deck/Cargo
Issued 2 October 1986 Resolved
REPAIR OR REPLACE SIGHT GLASS VALVE HANDLES ON DAY TANKS (CARGO HEATING OILAND AUXILIARY GENERATOR).
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Fire Fighting
Issued 10 October 1985 Resolved
SERVICE FIXED AND PORTABLE FIRE EXTINGUISHERS AND PROVIDE SERVICING REPORT.
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985
Deck/Cargo
Issued 10 October 1985 Resolved
REPAIR SEWAGE CLORINE INJECTION PUMP.
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985
Deck/Cargo
Issued 10 October 1985 Resolved
REVISE OIL TRANSFER PROCEDURE
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985
Engineering
Issued 6 October 1984 Resolved
REPLACE THE RELIEF VALVE TO THE #2 UPPER PORT AIR RECEIVER ND PROVE OPERATIONAL.
Condition: Unknown
Due 6 October 1984
Resolved 6 October 1984
Electrical
Issued 6 October 1984 Resolved
TEST THE EMERGENCY TRIPS TO DIESEL GENERATOR #1.
Condition: Unknown
Due 6 October 1984
Resolved 6 October 1984
Deck/Cargo
Issued 6 October 1984 Resolved
PROVE OPERATIONAL THE HIGH TEMPERATURE ALARM TO THE IGS FRESH WATER SYSTEM.
Condition: Unknown
Due 6 October 1984
Resolved 6 October 1984
Engineering
Issued 6 October 1984 Resolved
CONDUCT A FIRESIDE EXAM OF BOTH THERMAL FLUID HEATERS AS REQUIRED BY 46 CFR61.30.
Condition: Unknown
Due 6 October 1984
Resolved 6 October 1984
Deck/Cargo
Issued 6 October 1984 Resolved
PERFORM AN INTERNAL INSPECTION OF ALL CARGO TANKS AT BARGES NEXT DRYDOCKING
Condition: Unknown
Due 6 October 1984
Resolved 6 October 1984

Casualty record · 2

8 July 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2162212
4 August 2009Routine · role: Involved in a Marine Casualty · activity 3558198
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

VIRGINIA BAY (2004), BLUE HORIZON (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record