MAURY USCG vessel records Sign in
← All vessels

GULF FLEET NO. 66

GULF FLEET NO. 66 is a 1983 offshore supply vessel. The Coast Guard has recorded 41 inspections since 1985, most recently in June 2005, along with 63 deficiencies — 2 with no resolution recorded —.

Records from 1985 to 2005. Most recent: inspection, 23 June 2005.

Built
1983
Last inspected
23 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8301125 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBY3774
228680
Flag
UNITED ARAB EMIRATES
366756140 (licence lapsed)
Maury page id
psix-228680

Inspections, by type

…with no type recorded7
…past their stated due date2
Years with a record 16 calendar years (1985–2005)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1137 - Dead Weight, Ton
451 - Regulatory (Subpart C or D), Gross Ton
307 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBY3774MMSI 366756140 · cancelled · compulsorily equipped · granted 16 September 1998, cancelled 5 May 2003
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RESOLUTION Offshore Supply Vessel · MISLE 51184 · 20 April 1994 · activity 112420

Inspection history · 41

23 June 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2400161
14 August 2002 Administrative Inspection
Administrative · Activities Europe · Activity 1661267
19 October 1998 Administrative
Administrative · Activities Europe · Activity 801749
8 October 1998 Type not recorded
No type recorded · Activities Europe · Activity 802349
21 February 1998 Deficiency Check · COI Inspection
Physical examination · Activities Europe · Activity 783884
29 January 1998 Deficiency Check
Physical examination · Activities Europe · Activity 783885
16 January 1998 Administrative
Administrative · Activities Europe · Activity 1368552
15 November 1997 Re-Inspection
Physical examination · Activities Europe · Activity 1116975
30 July 1997 Type not recorded
No type recorded · Activities Europe · Activity 1116788
19 March 1997 Administrative
Administrative · Activities Europe · Activity 1096160
18 March 1996 Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884612
29 February 1996 Hull Examination · COI Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1353878
10 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189284
27 May 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171188
20 April 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 112420
9 March 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 220714
11 January 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 851560
20 November 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160149
11 October 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1162989
12 August 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844257
14 December 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135310
20 October 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254423
20 July 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268219
20 May 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256275
16 March 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952315
30 November 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256865
1 February 1991 Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933417
19 October 1990 Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 908613
26 July 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1242713
26 January 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978186
12 December 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921536
12 December 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232504
19 October 1988 COI Inspection · MARPOL Annex II Examination · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199772
21 January 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320735
22 November 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308090
21 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012028
29 October 1986 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019061
30 July 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986292
25 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995331
2 October 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301684
4 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982342

Deficiency record · 63

Construction/Loadline › Hull › Bottom Plating
Issued 8 October 1998 No resolution recorded
Gauge bottom plating, sideshell, deck, structural bulkheads, side longs. and stiffeners. Submit report to MIO EUROPE with repair proposal.
Condition: Unknown
Due 8 December 1998 — due date passed with no resolution recorded
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving › Buoyant Smoke Signals › General
Issued 8 October 1998 No resolution recorded
Due to overall condition of the vessel and vessel operating in Nigeria - Inspection for certification must be conducted prior to the vessel being returned to service. COI on file at MIO EUROPE.
Condition: Unknown
Due 8 December 1998 — due date passed with no resolution recorded
Resolution: Vessel Reflagged Deficiencies no longer apply.
Documentation
Issued 21 February 1998 Resolved
Prove proper operation of oily water separator. Until fixed, vsl MUST: 1)Lock overboard discharge 2)Designate an oily water "slop" tank 3) Trans all bilge water to slop tank 4) Document all bilge transfers in Oil Record Book 5) Doc all tran all slops to an approved shoreside reception facility.
Condition: Unknown
Due 26 May 1998
Resolved 26 May 1998
Lifesaving
Issued 15 November 1997 Resolved
Remove improper wiring and antennas throughout vessel. Vessel's port holes are not to be obstructed.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Fire Fighting
Issued 15 November 1997 Resolved
Provide proper number of approved fire hoses as required by 46 CFR 95 and vessel's COI. Hoses to be hydrostatically tested to 100 PSI and stenciled with vessel's name. Hoses to remain connected to hydrants at all times.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Navigation
Issued 15 November 1997 Resolved
Prove proper operation of vessel's installed fathometer.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Lifesaving
Issued 15 November 1997 Resolved
Conduct crew training of vessel's line throwing device and enter into vessel's log book.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Navigation
Issued 15 November 1997 Resolved
Prove proper operation of vessel's installed gyro compass.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Accommodation/Occupational Safety
Issued 15 November 1997 Resolved
Properly secure laundry dryer to its foundation.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Fire Fighting
Issued 15 November 1997 Resolved
Install approved portable fire extinguishers IAW 46 CFR 95 and vessel's_x001C_ COI. Extinguishers to be properly mounted throughout vessel.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Fire Fighting
Issued 15 November 1997 Resolved
Install fire pump discharge gauge in vessel's wheelhouse and prove proper operation.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Engineering
Issued 15 November 1997 Resolved
Test proper operation of main diesel engine and ship service generator highjacket water alarms. Enter satisfactory results in log book.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Electrical
Issued 15 November 1997 Resolved
Inform MIO Europe if vessel installed with fuel oil day tank low level alarm & electrical swithcboard reverse power interlocks. If installed, conduct tests and fax satisfactory results to MIO Europe.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Accommodation/Occupational Safety
Issued 15 November 1997 Resolved
Prove proper operation of all pressure vessel relief valves. Valves to be removed and bench tested. Fax satisfactory results to MIO Europe.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Accommodation/Occupational Safety
Issued 15 November 1997 Resolved
Reinstall the interior door handle to the galley reefer box and test properoperation.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Navigation
Issued 15 November 1997 Resolved
Provide an updated deviation table for the magnetic compasss and post in vessel's wheelhouse.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Navigation
Issued 15 November 1997 Resolved
Provide/prove proper operation of navigation light failure alarm panel. Vslrequired to have a navigation light indicator panel IAW 46 CFR 111.75-17(b).
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Navigation
Issued 15 November 1997 Resolved
Provide/prove proper operation of vessel's signal light IAW 46 CFR 111.75-18.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Lifesaving
Issued 15 November 1997 Resolved
Provide oars and rowlocks for vessel's rescue boat.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Lifesaving
Issued 15 November 1997 Resolved
Provide adult lifejackets as required by COI. PFD's must be properly markedand stowed IAW 46 CFR 199.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Lifesaving
Issued 15 November 1997 Resolved
Provide and attached manufacturers name/data plate to vessel's rescue boat.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Construction/Loadline
Issued 15 November 1997 Resolved
Repair, adjust and prove proper operation of vessel's watertight doors. All WTD gaskets to be in servicable condition and properly installed. When vsl underway, all watertight doors below decks shall remain secured. Remove all non approved securing devices from all WTD's.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Lifesaving
Issued 15 November 1997 Resolved
Conduct abandon ship drill. Enter satisfactory results in vessel's log bookand fax report to MIO Europe.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Accommodation/Occupational Safety
Issued 15 November 1997 Resolved
Make all crew accommodation spaces sanitary. Galley extractor requires degreasing. Laundry room bulkheads require approved panels/coverings. Missing/broken airconditioning/ventilation louvers require replacement as original.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Documentation
Issued 30 July 1997 Resolved
Provide complete ABS inspection report for the reinspection period of 28DEC96 thru 28APR97.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Fire Fighting
Issued 20 November 1993 Resolved
REPLACE OR HYDRO-TEST TWO FIXED CO2 BOTTLES WHICH ARE OVERDUE FOR HYDRO- TESTING PRIOR TO 20DEC93.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Lifesaving
Issued 20 November 1993 Resolved
PROVIDE PERMANENT JUNCTION BOX FOR STBD/PORT LIFERAFT ILLUMINATION PRIOR TOVESSEL OPERATION.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Navigation
Issued 20 November 1993 Resolved
REPAIR FORE AND AFT BRIDGE RUDDER ANGLE INDICATORS TO REFLECT TRUE RUDDER POSITION, PRIOR TO 20DEC93 OR NEXT VOYAGE.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Engineering
Issued 20 November 1993 Resolved
PROVIDE FLASH PROTECTION BOWLS FOR ALL RACOR OIL FILTERS PRIOR TO 20DEC93.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Deck/Cargo
Issued 20 November 1993 Resolved
PROVE PROPER OPERATION OF TOWING WINCH TO SATISFACTION OF USCG INSPECTOR PRIOR TO 20DEC93. WINCH NOT TO BE USED UNTIL THIS REQT IS CLEARED.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Deck/Cargo
Issued 20 November 1993 Resolved
PROVIDE PROPER ANCHOR FOR PORT SIDE. VESSEL NOT TO BE OPERATED UNTIL THIS REQT IS CLEARED.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Fire Fighting
Issued 20 November 1993 Resolved
PROVIDE PROPER APPLICATORS FOR #4 & #5 E/R FIRE STATIONS, PRIOR TO 20DEC93.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Deck/Cargo
Issued 20 November 1993 Resolved
PROVIDE APPROVED RELIEF VALVES FOR #4 & #6 STBD DRY BULK P-TANKS. TANKS SHALL NOT BE USED UNTIL THIS REQT IS CLEARED.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Lifesaving
Issued 20 November 1993 Resolved
PROVIDE PERMANENT CRADLE AND ILLUMINATION FOR RESCUE BOAT TO THE SATISFACTION OF USCG PRIOR TO 20DEC93.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Documentation
Issued 20 November 1993 Resolved
PROVIDE COPY OF OIL TRANSFER PROCEDURES PRIOR TO 20DEC93 AND NEXT TRANSFER OPS.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Lifesaving
Issued 20 November 1993 Resolved
CONDUCT FIRE AND BOAT DRILLS UPON RETURN OF CREW TO VESSEL PRIOR TO NEXT VOYAGE.
Condition: Unknown
Due 20 November 1993
Resolved 20 November 1993
Electrical
Issued 20 October 1992 Resolved
PROVIDE LIGHT COVERS FOR FIXTURES IN RUDDER ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Navigation
Issued 20 October 1992 Resolved
PROVIDE RULES OF THE ROAD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 20 October 1992 Resolved
REPAIR/REPLACE EMERGENCY LOUDSPEAKER SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Lifesaving
Issued 20 October 1992 Resolved
CONDUCT MAN OVERBOARD DRILL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Accommodation/Occupational Safety
Issued 20 October 1992 Resolved
REPAIR/REPLACE MOTOR FOR ENGINE ROOM VENTILATION SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 20 October 1992 Resolved
REPAIR OVERSPEED FOR STARBOARD GENERATOR AND PROVE PROPER OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Accommodation/Occupational Safety
Issued 20 October 1992 Resolved
REPAIR STARBOARD REEFER MOTOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Accommodation/Occupational Safety
Issued 30 November 1991 Resolved
MAKE ALL SIX DRY BULK TANKS AVAILABLE FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 30 November 1991
Resolved 30 November 1991
Documentation
Issued 19 October 1990 Resolved
OBTAIN U.S. COAST GUARD APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Documentation
Issued 19 October 1990 Resolved
OBTAIN U.S. COAST GUARD APPROVED AUTOMATION SERVICING AND TESTING PLANS.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Deck/Cargo
Issued 19 October 1990 Resolved
HAVE P-TANKS DUST FREE AND CERTIFIED GAS FREE BY A MARINE CHEMIST FOR INSPECTION AT NEXT CREDIT DRYDOCK.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Fire Fighting
Issued 12 December 1989 Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Accommodation/Occupational Safety
Issued 12 December 1989 Resolved
PROVIDE A PROPER RELIEF VALVE FOR THE HOT WATER HEATER, TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Engineering
Issued 12 December 1989 Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR AND OBTAIN U.S. COAST GUARD ENDORSEMENT TO INT'L OIL POLLUTION PREVENTION (IOPP) CERTIFICATE (ANNUAL SURVEY), TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Engineering
Issued 12 December 1989 Resolved
DEMONSTRATE PROPER OPERATION OF PORT MAIN ENGINE OVERSPEED ALARM, TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Construction/Loadline
Issued 12 December 1989 Resolved
DEMONSTRATE PROPER WATERTIGHT SEAL OF FORWARD ENGINEROOM WATERTIGHT DOOR, TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Fire Fighting
Issued 22 November 1987 Resolved
INSPECT FIXED CO2 SYSTEM FOR MACHINERY SPACE AND PROVIDE SERVICE REPORT.
Condition: Unknown
Due 22 November 1987
Resolved 22 November 1987
Electrical
Issued 25 March 1986 Resolved
REPAIR OR RENEW OVERSPEED TRIPPING DEVICE ON STARBOARD GENERATOR. MAINTAIN LIVE WATCH UNTIL REPAIRED.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Deck/Cargo
Issued 25 March 1986 Resolved
REPAIR OR REPLACE INOPERATIVE SWITCH FOR FUEL OIL TRANSFER DUMP REMOTE SHUTDOWN, MAINTAIN LIVE WATCH UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Navigation
Issued 25 March 1986 Resolved
REPAIR OR RENEW EMERGENCY RUDDER ANGLE INDICATOR IN ENGINE ROOM AND PROVE ITS OPERATION. COMPLY WITH PRIOR TO 25APR86.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Navigation
Issued 4 February 1985 Resolved
REPAIR OR RENEW EMERGENCY RUDDER ANGLE INDICATOR IN ENGINE ROOM.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Lifesaving
Issued 4 February 1985 Resolved
PROVIDE BATTERY TO OPERATE EMERGENCY LIGHT.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Electrical
Issued 4 February 1985 Resolved
REPAIR OR RENEW WINDSHIELD WIPER ON FORWARD SIDE OF WHEELHOUSE.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Unknown
Issued 4 February 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, GULF FLEET NO. 66, DN661148 AND ARE TO BE COMPLIED WITH BY 04MAR85.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Electrical
Issued 4 February 1985 Resolved
REPAIR OR RENEW BOTH EMERGENCY LIGHTS AND CONNECTIONS BOXES FOR LIFERAFTS REPAIR OR RENEW TWO EMERGENCY LIGHTS IN WHEELHOUSE AND LIGHT IN FOSCILE DECK REPAIR OR RENEW EMERGENCY LIGHT AT ENGINE ROOM EXIT STBD SIDE .
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Unknown
Issued 4 February 1985 Resolved
RENEW THREE HOLED FIRE HOSES. RENEW THREE FIREMAIN VALVES WITH NATIONAL STANDARD FIRE HOSE THREADS (9) NINE THREADS PER INCH.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Electrical
Issued 4 February 1985 Resolved
RENEW OR REPAIR STARTER FOR STARBOARD SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985

Ownership record