MAURY USCG vessel records Sign in
← All vessels

RESOLUTION

RESOLUTION is a 1980 offshore supply vessel. The Coast Guard has recorded 68 inspections since 1982, most recently in March 2020, along with 90 deficiencies and 4 casualty investigations between 2010 and 2019.

Records from 1982 to 2020. Most recent: inspection, 4 March 2020.

Built
1980
Last inspected
4 March 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7901966 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE7994
Flag
UNITED STATES
367060750, 367400220, 368162000 (licence lapsed)
Maury page id
psix-51184

Inspections, by type

…with no type recorded13
Years with a record 35 calendar years (1982–2020)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it750 - Convention (Subpart B), Gross Ton
297 - Regulatory (Subpart C or D), Gross Ton
225 - Convention (Subpart B), Net Ton
202 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE7994MMSI 367400220 · cancelled · compulsorily equipped · granted 8 March 2019, cancelled 26 April 2024
WDC6748MMSI 367060750 · expired · compulsorily equipped · granted 5 August 2005, cancelled 10 October 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCY5807MMSI not assigned · expired · voluntarily equipped · granted 22 July 1998, cancelled 27 September 2008 · licensed under a name not among this hull’s recorded names (not shown)
WQZ7042MMSI 368162000 · cancelled · compulsorily equipped · granted 22 January 1998, cancelled 7 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PERSEVERANCE Offshore Supply Vessel · MISLE 49112 · 19 January 2012 · activity 4245971GULF FLEET NO. 66 Offshore Supply Vessel · MISLE 228680 · 20 April 1994 · activity 112420

Inspection history · 68

4 March 2020 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6920118
4 April 2019 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6656232
8 March 2019 Administrative Inspection · Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6639374
8 March 2019 Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6650909
2 October 2018 MTSA Verification · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6553618
20 September 2017 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6275677
1 May 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6236975
16 November 2016 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6077897
10 February 2016 Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5827349
3 November 2015 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6076590
17 August 2015 COI Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5212211
15 October 2014 Deficiency Check · MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4998432
2 July 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4366404
19 January 2012 Damage Survey
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4228823
19 January 2012 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4245971
7 January 2010 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3660542
4 March 2009 Construction Oversight · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3448573
30 September 2008 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3340138
23 January 2007 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2860574
14 June 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390652
1 June 2005 Hull Examination · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2375899
18 May 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2071139
3 July 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1833732
12 August 2002 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1660499
12 July 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215356
21 May 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447104
19 May 2000 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465563
22 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1030964
26 July 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1105282
14 June 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408324
1 June 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 760778
17 May 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210308
31 March 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 67789
11 December 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808600
26 October 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 803837
10 October 1998 Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1413429
11 August 1997 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1116943
3 July 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 220990
3 July 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 224400
3 July 1997 Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1424433
12 January 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1181099
30 July 1995 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875767
20 April 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 112420
21 November 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 79042
20 November 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847782
6 November 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847969
22 July 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848515
13 April 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135316
2 April 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833758
24 March 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145734
20 May 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945766
28 April 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257818
16 March 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262338
9 March 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257624
22 February 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258410
9 January 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952895
26 March 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901338
6 March 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916133
8 March 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 898820
9 December 1988 MARPOL Annex II Examination · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342080
5 April 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343547
10 March 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338773
8 May 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011755
10 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320067
14 March 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306400
25 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285653
2 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974158
26 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966151

Deficiency record · 90

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 March 2019 Resolved
No repairs affecting the safety of the vessel with regard to the hull shall be made without the knowledge of the Officer in Charge of Marine Inspection. Vessel has three 1/4" cracks on weld seams in hull IVO of the port MDE. Vessel completed temp repairs under the guidance and approval from ABS and USCG. Prior to operations proceed directly to dry-dock for permanent repairs. Prior to permanent repairs, vessel shall be inspected and submit a repair proposal to the cognizant OCMI for approval.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2020
Resolution: Vessel has been scrapped.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 March 2019 Resolved
During the underwater survey, the hull plating welds appeared to be deteriorated in the bow between frames 22 and 24 1/2. The interior welds were temporaily repaired in the same manner as the hull welds in the E/R for integrity purposes as no leaks were observed. However, upon this observation the vessel shall be drydocked and conduct a drydock and internal structural exam to assess the extent of the damage and effect permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2020
Resolution: Vessel has been scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 November 2018 Resolved
Fire pump seal is leaking excessively.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 10 March 2019
Resolution: Vessel installed new fire pump.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2018 Resolved
Excess oil has built up in engine room bilges, around both generators and lube oil piping on main engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 11 March 2019
Resolution: Vessel is having OCM serviced in Seattle. MI extended Def until end of March.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2018 Resolved
Properly install fixed wiring for heater in line box to connect it to vessel's electrical system.
Action required: 10 - Deficiency Rectified
Due 6 December 2018
Resolved 10 March 2019
Resolution: Vessel properly installed wiring via junction box to distribution panel and removed extension cord.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 November 2018 Resolved
If additional lighting is necessary in engine room, remove portable lights connected to extension cords and install additional fixed lighting.
Action required: 10 - Deficiency Rectified
Due 6 December 2018
Resolved 10 March 2019
Resolution: Vessel removed extension cord and portable lighting.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 November 2018 Resolved
Circuit lamp test is not operational on engine room alarm panel, no lights lit up upon testing. High temp alarm on Gen #2 did not light up, audible only.
Action required: 705 - Other - as specified
Due 6 December 2018
Resolved 4 March 2020
Resolution: Vessel has been scrapped.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 6 November 2018 Resolved
Oil content meter and alarm on OWS are not operating properly. Repair to proper operation or remove system from vessel.
Action required: 705 - Other - as specified
Due 6 December 2018
Resolved 4 March 2020
Resolution: Vessel has been scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 6 November 2018 Resolved
Rudder angle indicators on port and starboard bridge wings do not align with primary center steering station.
Action required: 10 - Deficiency Rectified
Due 6 December 2018
Resolved 10 March 2019
Resolution: Rudder Angle Indicators on bridge wings were repairs and consistent with main steering station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2018 Resolved
Retro reflective tape on life rings located on starboard bridge wing and port quarter stern need to be replaced.
Action required: 10 - Deficiency Rectified
Due 6 December 2018
Resolved 10 March 2019
Resolution: Retro on stbd bridge winf and port quarter stern were repaired satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 November 2018 Resolved
Watertight door at port maintenance room needs to be adjusted to open and close properly.
Action required: 10 - Deficiency Rectified
Due 6 December 2018
Resolved 10 March 2019
Resolution: Vessels port maintenance dogs were adjusted to open and close. MI confirmed chalk test also. All sat.
Lifesaving › Hand Flares › Expired
Issued 20 September 2017 Resolved
Vessel had 2 expired flares.
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 6 November 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 September 2017 Resolved
Life ring light on portside was inoperable.
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 6 November 2018
Lifesaving › Lifebuoys › Immediately Available
Issued 20 September 2017 Resolved
Vessel had two deck liferings stowed and not readily available and not IAW FCP.
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 6 November 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 September 2017 Resolved
Vessel had expired medicine in first aid kit.
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 6 November 2018
Communications › Public Address System › Loudspeaker
Issued 20 September 2017 Resolved
Vessels front speaker for PA was inpoerable. Vessel was aware and had new one but not installed.
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 6 November 2018
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 November 2016 Resolved
The bilges in the machinery space have an accumulation of oil that creat a fire hazard. Vesel must remove oily water from bilge to the satisfaction of the MI.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 3 January 2017
Resolution: Vessel was cleaned and provided receipt that vac truck removed oil from E/R bilges.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 17 August 2015 Resolved
Prove proper operation of bow thruster engine to include oil pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 16 November 2016
Resolution: Completed Annual Inspection-rectified deficiency.
Fire Fighting › Fire Pumps › Pressure
Issued 17 August 2015 Resolved
Prove proper operation of fire pump pressure gauge on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 16 November 2016
Resolution: Completed Annual Inspection- rectified deficiency.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 August 2015 Resolved
Install blank on forward machine space - 440 panel (near bow thruster)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 24 September 2015
Resolution: cover placed on open breaker space
Lifesaving › Immersion Suits › Marking
Issued 17 August 2015 Resolved
Label all immersion suits with vessel's name
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 24 September 2015
Resolution: All immersion suits on board were marked properly
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 17 August 2015 Resolved
Repair start air alarms on MDE's
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 16 November 2016
Resolution: Completed Annual Inspection- Rectified deficiency.
Engineering › Freshwater System (injector cooling) › Sensor
Issued 17 August 2015 Resolved
Repair high oil temp and high coolant temp alarms on gen #1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 16 November 2016
Resolution: Completed Annual Inspeection-Rectified Deficiency.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 August 2015 Resolved
Submit updated alarm test procdures as tested today
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 2 November 2015
Resolution: Revisions submitted.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 August 2015 Resolved
complete automation tests on port and stbd main engines as listed on approved procedures
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 16 November 2016
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 15 October 2014 Resolved
Provide evidence of a Marine Radio Operator Permit for any crew member that operates a radio. 47CFR80.159
Action required: 705 - Other - as specified
Resolved 3 April 2015
Resolution: permits provided
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 October 2014 Resolved
Update Fire & Safety Plan to include Fire Detection system. Submit to OCMI for review & approval. 46CFR97.36-1
Action required: 705 - Other - as specified
Resolved 16 July 2015
Resolution: FCP correct, verified and approved.
Fire Fighting › Fire Pumps › Pressure
Issued 15 October 2014 Resolved
Prove proper operation of fire pump pressure gauge in wheelhouse. 46CFR95.10-5
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 5 December 2014
Resolution: Witnessed satisfactory operation of pressure gauge.
Lifesaving › Lifebuoys › Serviceable
Issued 15 October 2014 Resolved
Replace port side bridge wing lifebuoy. 46CFR199.70
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 5 December 2014
Resolution: verified new lifebuoy on port stide bridge wing
Electrical › Electric Generation Source (service) › Generator
Issued 15 October 2014 Resolved
Identify & secure lube oil leaks on #2 generator 46CFR111.12-1
Action required: 705 - Other - as specified
Resolved 3 April 2015
Resolution: leaks corrected
Electrical › Electric Generation Source (service) › Generator
Issued 15 October 2014 Resolved
Replace RPM Gauge on #1 generator
Action required: 705 - Other - as specified
Resolved 3 April 2015
Resolution: Gauge replaced
Electrical › Electric Generation Source (service) › Generator
Issued 15 October 2014 Resolved
Replace cotton jacketed hoses with approved SAE J-1942 fuel/oil hoses on #2 generator 46CFR56.60-25(b)
Action required: 705 - Other - as specified
Resolved 17 August 2015
Engineering › Bilge Water Management System › Strainer
Issued 15 October 2014 Resolved
Remove debris & mud in bilge in tunnel near Engine room entrance 46CFR56.50-50
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 5 December 2014
Resolution: mostly cleaned
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 20 January 2012 Resolved
Demonstrate proper function of Port Clutch/Transmission prior to entering into service. Vessel permitted to transit from OSK dock in Nikiski to Homer to effect repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2012
Resolution: Replaced damaged clutch components in kind. Sea trials test satisfactory.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 7 January 2010 Resolved
There was an exhaust leak on the #2 SSDG.
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Electrical › Electric Supply System (service) › Cable
Issued 7 January 2010 Resolved
#2 SSDG had a bad connection to the starting batteries. Required to clean, tighten, or renew.
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 January 2010 Resolved
Repair exhaust leak on #1 SSDG.
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Engineering › Fuel Oil Service System › Hose
Issued 7 January 2010 Resolved
Wear showing on f/o lines of #1 MDE. Provide chafing gear.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Engineering › Fuel Oil Service System › Hose
Issued 7 January 2010 Resolved
F/o hose on #2 MDE was leaking and needs repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 7 January 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 January 2010 Resolved
No current fire system servicing certificate.
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 7 January 2010
Resolution: vessel provided fire service report
Engineering › Steering Gear System › Pump
Issued 7 January 2010 Resolved
There was a leak on the hose for the #2 steering pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Communications › Internal Communications System › Sound-powered Telephone
Issued 7 January 2010 Resolved
Comms were not possible from the ER. There was too much noise to use sound powered phone. Required to provide headset.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Resolution: engine room sound powered phone had jv box installed that allows operator to don hearing protection/isolation sound powered phone to communicate with bridge
Construction/Loadline › Structures › Door
Issued 7 January 2010 Resolved
The dogs on the E/R - Steering watertight door did not close the door properly. Dogs required adjusting to properly close door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 January 2010 Resolved
Bridge window heater were installed using extension cords. Window heaters will be a permanent addition to vessel; therefore are required to be wired to vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 January 2010 Resolved
Stack spaces on main deck were labelled as exits. Remove exit labelling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 January 2010 Resolved
Replace wiring on dryer. Remove extension cords and secure washer and dryer to secure for sea.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 20 January 2010
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 30 September 2008 Resolved
The #2 generated failed to overspeed twice. Determined that the flap was failing to close on the intake.
Condition: Improper/Lack of Maintenance
Due 30 September 2008
Resolved 30 September 2008
Resolution: Lubricated the flap and generater sucessfully oversped on two separate attempts.
Stability › Watertight Integrity › General
Issued 30 September 2008 Resolved
Starboard escape hatch had a piece of gasket hanging loose from the door.
Condition: Unknown
Due 30 September 2008
Resolved 30 September 2008
Resolution: Pressed gasket back into place.
Engineering › Steering Gear System
Issued 3 July 2003 Resolved
Repair/test proper operation of steering gear to the satisfaction of the attending ABS surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2003
Resolution: Received fax stamped by ABS stating the deficiency was corrected.
Unknown
Issued 21 May 2001 Resolved
PROVIDE REPAIR PROPOSAL TO MSC FOR PERMENENT REPAIRS TO P-TANKS #4, #5, AND#6.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Unknown
Issued 21 May 2001 Resolved
1. THE FOLLOWING DRYBULK TANKS ARE RE-RATED TO 40 PSI MAWP: #4 P-TANK, #5 P-TANK, AND #6 P-TANK. REPAIR PROPOSAL IS BEING EXAMINED BY MSC. FINAL ACTION PENDS. USE OF THESE TANKS SHALL BE DISCONTINUED BY 22AUG01. FINAL REPAIRS TO BE WITNESSED BY AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Deck/Cargo
Issued 19 May 2000 Resolved
01. THE FOLLOWING DRYBULK TANKS RE-RATED TO 40PSI MAWP. 1) STBD_x001C_ VOID #3 P-TANK #4. 2) PORT VOID #3 P-TANK #5. 3) STBD VOID #3 P-TANK #6._x001C_ FEASIBILITY OF PERMANATE RE-RATING BEING EXAMINED BY MSC. FINAL ACTION PENDS.
Condition: Unknown
Due 19 May 2001
Resolved 22 May 2001
Lifesaving
Issued 14 June 1999 Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH USCG DISTRICT POLICY. RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS DATED 12NOV98. TO SATISFACTION ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Electrical
Issued 10 October 1998 Resolved
INSTALL EMERGENCY LIGHTING TO ILLUMINATE ELECTRICAL POWER PANEL AND BATTERYSTARTED GENERATOR.
Condition: Unknown
Due 25 October 1998
Resolved 18 November 1998
Lifesaving
Issued 10 October 1998 Resolved
RENEW THE 2 LIFE RINGS ON BRIDGE AND RENEW RETRO ON THE 2 LIFE RINGS ON THECARGO DECK. THE LIFE RINGS ON THE BRIDGE WERE DRY ROTTED.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Construction/Loadline
Issued 10 October 1998 Resolved
RENEW GASKET ON E/R WTD TO BOW-THRUSTER PASSAGEWAY. EXISTING GASKET HAS A_x001C_ 4 INCH GAP.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Lifesaving
Issued 10 October 1998 Resolved
LABEL THE LIFE JACKET LOCKERS IN THE CREW'S ACOMMODATION ROOMS.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Deck/Cargo
Issued 10 October 1998 Resolved
PROVIDE VERIFICATION OF PRESSURE TEST ON FUEL AND LIQUID MUD HOSES.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Engineering
Issued 10 October 1998 Resolved
ENSURE PROPER OPERATION OF ENGINEERING AUTOMATION AND CONTROL SYSTEM.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Lifesaving
Issued 10 October 1998 Resolved
RENEW ALL 12 DISTRESS SIGNALS, EXPIRATION DATES ARE 11/98.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Engineering
Issued 10 October 1998 Resolved
ENSURE PROPER CONTAINMENT AROUND STARBOARD DAY AND #2 FUEL TANKS VENTS. THEEXISTING CONTAINMENT DOES NOT COVER THESE VENTS AND A 5 GAL BUCKET CAN NOT FIT.
Condition: Unknown
Due 10 November 1998
Resolved 18 November 1998
Deck/Cargo
Issued 10 October 1998 Resolved
PROVIDE VERIFICATION OF PRESSURE TEST OF THE 6 DRY BULK TANK AND 2 PRESSUREVESSEL'S RELIEF VALVES
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Electrical
Issued 10 October 1998 Resolved
REPAIR ELECTRICAL CONNECTION ON ANCHOR WINDLASS. WIRING JUNCTION BOX ON WINDLASS IS BROKEN.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Construction/Loadline
Issued 10 October 1998 Resolved
PROVIDE W/T FITTING TO DISCONTINUED THROUGH BLKHD PIPE IN WAY OF COLLISION BLKHD.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Lifesaving
Issued 10 October 1998 Resolved
REMOVE FUEL OIL AND WATER FROM BOW-THRUSTER PASSAGEWAY BILGE.
Condition: Unknown
Due 25 October 1998
Resolved 18 November 1998
Documentation
Issued 10 October 1998 Resolved
UPDATE FUEL OIL TRANSFER PROCEDURES IN ACCORDANCE 33 CFR 156.00
Condition: Unknown
Due 10 November 1998
Resolved 18 November 1998
Lifesaving
Issued 10 October 1998 Resolved
RENEW 4 LIFE JACKET LIGHTS (EXPIRED)
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998
Unknown
Issued 10 October 1998 Resolved
UPDATE VESSEL'S ENGINEERING AUTOMATION TEST PROCEDURES AND HAVE APPROVED BYTHE COAST GUARD.
Condition: Unknown
Due 10 October 1998
Resolved 10 October 1998
Fire Fighting
Issued 30 July 1995 Resolved
PROVE PROPER OPERATION OF SMOKE DETECTION CABINET IN WHEELHOUSE.
Condition: Unknown
Due 30 July 1995
Resolved 30 July 1995
Fire Fighting
Issued 30 July 1995 Resolved
PROVE PROPER OPERATION OF FIRE PUMP PRESSURE GAUGE IN WHEELHOUSE.
Condition: Unknown
Due 30 July 1995
Resolved 30 July 1995
Navigation
Issued 24 March 1993 Resolved
REPAIR FURUNO RADAR ON BRIDGE OR REMOVE.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 24 March 1993 Resolved
PROVIDE UPDATED OR NEW EPIRB.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Navigation
Issued 24 March 1993 Resolved
REPAIR FOLLOW UP STEERING ON BRIDGE OR REMOVE.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 24 March 1993 Resolved
REPAIR PUBLIC ADDRESS SYSTEM ON BRIDGE.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Construction/Loadline
Issued 24 March 1993 Resolved
MAKE PROPER REPAIRS TO BILGE AND BALLAST DISCHARGE IN WAY OF CHECK VALVE AND DISCHARGE POINT FLANGE AT NEXT DRYDEOCK PERIOD.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Documentation
Issued 24 March 1993 Resolved
PROVIDE 33 CFR 0-199.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Fire Fighting
Issued 9 January 1992 Resolved
INSTALL FIXED 20LB CO2 FOR PAINT LOCKER.
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992
Lifesaving
Issued 9 January 1992 Resolved
REPLACE TWENTY-FIVE (25) BLANK CHARGES FOR SHOULDER LINE THROWING GUN.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Fire Fighting
Issued 9 January 1992 Resolved
SERVICE THREE (03) DRY CHEMICAL FIRE EXTINGUISHERS LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 9 January 1992 Resolved
REPAIR FORWARD BILGE ALARM LOCATED IN BOW THRUSTER PASSAGEWAY AND PROVE PROPER OPERATION.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Fire Fighting
Issued 9 January 1992 Resolved
PROVIDE ONE UL APPROVED 50 FOOT FIRE HOSE (1 1/2" X 50')
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Lifesaving
Issued 9 January 1992 Resolved
REPLACE EPIRB BATTERY.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Navigation
Issued 9 January 1992 Resolved
PROVIDE CURRENT TIDE TABLES AND SAILING DIRECTIONS.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Fire Fighting
Issued 9 January 1992 Resolved
REPAIR FIRE ALARM (PYROTRONICS) AND PROVE PROPER OPERATION.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Lifesaving
Issued 9 January 1992 Resolved
PROVIDE ONE(1) ADDITIONAL COAST GUARD APPROVED LIFE PRESERVER.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Deck/Cargo
Issued 9 January 1992 Resolved
PROVE PROPER OPERATION OF SIX (06) SAFETY RELIEF VALVES FOR BULK TANKS.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Deck/Cargo
Issued 9 January 1992 Resolved
REPAIR BRAKE FOR PORT WINDLASS AND PROVE PROPER OPERATION OF BRAKE AND ANCHOR.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Engineering
Issued 9 January 1992 Resolved
PROVE PROPER OPERATION OF HIGH WATER TEMPERATURE ALARMS FOR PORT AND STARBOARD MAIN DIESEL ENGINES, AND GENERATORS.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Engineering
Issued 9 January 1992 Resolved
REPAIR PORT AND STARBOARD REMOTE SHUTDOWNS FOR MDE'S AND PROVE PROPER OPERATION .
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Navigation
Issued 10 March 1988 Resolved
INSTALL PROPER NAVIGATION LIGHT LAMP SOCKET AND LAMP, AS ORIGINALLY EQUIPPED, WITH THE APPROVED NAVIGATION LIGHTING SYSTEM. SEE 46 CFR 111.75-17(D) & PERKO PRODUCT LITERATURE.
Condition: Unknown
Due 10 March 1988
Resolved 10 March 1988

Casualty record · 4

27 August 2010Routine · role: Involved in a Marine Casualty · activity 3844598
19 January 2012Routine · role: Involved in a Marine Casualty · activity 4245971
30 July 2013Routine · role: Acknowledged Pollution Source · activity 4676901
8 March 2019Routine · role: Involved in a Marine Casualty · activity 6650909
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.