Records from 1983 to 2005. Most recent: inspection, 25 March 2005.
Inspection history · 85
25 March 2005
Plan Review (Other than "T")
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2319569
22 September 2004
Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2192324
26 September 2003
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1914113
4 August 2003
Annual Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1864012
28 January 2003
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1736612
14 November 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1720178
6 November 2002
Annual Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1701901
25 October 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1708936
13 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1661059
14 May 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1616790
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607024
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607063
8 January 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1476388
8 August 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370351
29 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070066
29 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822367
25 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443069
11 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823752
9 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050498
17 August 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426261
11 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112274
1 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082567
19 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120562
11 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129266
20 November 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805235
24 August 1998
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396982
24 August 1998
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1441409
2 July 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1128559
26 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122527
13 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1107235
9 January 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1119997
20 August 1997
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1375101
24 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1104502
3 February 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1103631
20 December 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1095830
31 October 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1174737
7 October 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457393
1 October 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1383340
24 August 1996
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355934
2 November 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1190536
20 September 1995
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 875177
18 August 1995
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1459188
13 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186833
28 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 63183
14 December 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148362
6 December 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138578
2 November 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1176758
28 September 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387614
15 February 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 99277
24 August 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393977
8 October 1992
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1251800
22 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 154498
25 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 159736
31 January 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 108146
5 January 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 9728
19 November 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 942278
1 October 1991
Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248781
28 August 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252712
12 July 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 936018
10 May 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1221509
14 March 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1245031
7 January 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 907456
23 October 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1218491
15 August 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 911581
14 August 1990
Drydock Extension · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 907684
5 March 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234262
12 February 1990
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 915668
5 December 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215020
27 September 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009242
30 August 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350816
8 August 1988
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1044901
14 October 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1322850
4 September 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1003046
2 September 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1311141
16 December 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1022966
25 September 1986
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1009983
20 May 1986
Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1305982
18 October 1985
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1305800
6 September 1985
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 988394
16 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983619
4 January 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976320
28 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284558
13 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976996
23 September 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973052
23 September 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281199
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 September 2003
Resolved
Clear all outstanding conditions of class.
Due 29 December 2003
Resolved 22 September 2004
Construction/Loadline › Hull
Issued 4 August 2003
Resolved
Complete phase II of hull exam prior to next rig move. Provide copies of all 3rd party service reports (divers, ABS, etc.) to MSO Port Arthur. LEGACY COMPONENT DESC: Weld
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2003
Resolution: ABS completed underwater portion.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 4 August 2003
Resolved
Ensure portable fire extinguisher numbers are restenciled if they've been painted over. Review 46CFR subpart G & remark items as applicable. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Resolved 30 October 2003
Stability › Watertight Integrity
Issued 4 August 2003
Resolved
Ensure tight fit on WTDs, particularly third level accommodation spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2003
Electrical › Electrical Distribution System (service)
Issued 4 August 2003
Resolved
Replace duct tape with blanks in breaker box in galley/stores area. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 4 August 2003
Resolved
Repair hole in ceiling in galley & p-tank rooms.
Action required: 705 - Other - as specified
Resolved 30 October 2003
Construction/Loadline › Hull
Issued 4 August 2003
Resolved
Replace/repair suction strainer and ladder wrung in #8 drill water tank.
Action required: 705 - Other - as specified
Resolved 30 October 2003
Construction/Loadline › Hull
Issued 4 August 2003
Resolved
Renew ladder brace (wrung) in preload 1A and renew sheared bracket in hull bottom.
Action required: 705 - Other - as specified
Resolved 30 October 2003
Operations/Management
Issued 4 August 2003
Resolved
Complete any outstanding requirements from SS H #6 (ABS).
Action required: 705 - Other - as specified
Resolved 20 October 2003
Lifesaving › Lifeboat
Issued 4 August 2003
Resolved
Repair port lifeboat. Small fracture in upper shell, aft (non-structural). LEGACY COMPONENT DESC: Hull
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 30 October 2003
Construction/Loadline › Penetrations
Issued 7 November 2002
Resolved
RENEW DIESEL FUEL VENT AFT OF ACCOMADATION SPACE ON PORT SIDE.
Due 7 December 2002
Resolved 14 November 2002
Resolution: OIM ATTESTED TO REPAIR.
Construction/Loadline › Structures
Issued 7 November 2002
Resolved
CROP AND RENEW, BACK TO GOOD STEEL, (MIN 18"X18") WATERTIGHT DOOR STBD SIDE, THIRD DECK.
Due 7 December 2002
Resolved 14 November 2002
Resolution: OIM ATTESTED TO REPAIR.
Fire Fighting › Means of Escape
Issued 7 November 2002
Resolved
ON STBD AFT LEG, REPLACE MISSING LADDER SECTIONS.
Due 7 December 2002
Resolved 14 November 2002
Resolution: OIM ATTESTED TO REPAIR.
Fire Fighting › Fire Main › Condition
Issued 7 November 2002
Resolved
RENEW FIRE MAIN PIPING AT FIRE STATION #1 (NEAR HELO DECK).
Due 7 December 2002
Resolved 14 November 2002
Resolution: OIM ATTESTED TO REPAIR.
Construction/Loadline › Penetrations
Issued 7 November 2002
Resolved
CROP AND RENEW ELECTRICAL CONDUIT NEAR AFT AREAS OF HOUSE (PORT & STBD).
Due 7 December 2002
Resolved 14 November 2002
Resolution: OIM ATTESTED TO REPAIR.
Construction/Loadline
Issued 8 August 2001
Resolved
CROP AND RENEW SOUNDING TUBE FOR DRILL WATER TANK #3
Condition: Unknown
Due 8 September 2001
Resolved 6 September 2001
Construction/Loadline
Issued 8 August 2001
Resolved
crop and renew ladder in void #7
Condition: Unknown
Due 8 September 2001
Resolved 6 September 2001
Construction/Loadline
Issued 8 August 2001
Resolved
Ensure proper operation of all equilizer valves.
Condition: Unknown
Due 8 September 2001
Resolved 6 September 2001
Construction/Loadline
Issued 8 August 2001
Resolved
crop and renew wastd longitudinal pre-load #3A, Crop and insert holed area in bulkhead dividing pre-load tanks 3 and 3A.
Condition: Unknown
Due 30 September 2001
Resolved 6 September 2001
Construction/Loadline
Issued 8 August 2001
Resolved
CONDUCT NDE OF CRITICAL CONNECTIONS, LEG TO CAN AND UNDER CAN SWIM-BY, PROVIDE COPY OF REPORT AND DIVERS VIDEO TO [name withheld].
Condition: Unknown
Due 8 October 2001
Resolved 23 October 2001
Construction/Loadline
Issued 8 August 2001
Resolved
CROP AND RENEW VENT GOOSE NECK FOR PRE-LOAD TANK #1A
Condition: Unknown
Due 8 September 2001
Resolved 6 September 2001
Lifesaving
Issued 17 August 1999
Resolved
CROP AND RENEW WASTED AND HOLED HAND RAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 17 September 1999
Resolved 13 September 1999
Lifesaving
Issued 17 August 1999
Resolved
RENEW LIFE LINES ON BOTH LIFE BOATS.
Condition: Unknown
Due 24 August 1999
Resolved 13 September 1999
Unknown
Issued 17 August 1999
Resolved
MAKE MUD PIT DOORS SELF CLOSING AND GAS TIGHT.
Condition: Unknown
Due 17 September 1999
Resolved 13 September 1999
Fire Fighting
Issued 17 August 1999
Resolved
REPLACE WEATHER TIGHT DOOR ON PAINT LOCKER AND PROVIDE OPERATING INSTRUCTIONS FOR IT'S FIXED CO2 SYSTEM.
Condition: Unknown
Due 17 September 1999
Resolved 13 September 1999
Unknown
Issued 17 August 1999
Resolved
REPLACE MAIN DECK REFUELING STATION HOSE AND PROVIDE DEAD MAN TYPE NOZZLE.
Condition: Unknown
Due 17 August 1999
Resolved 13 September 1999
Unknown
Issued 17 August 1999
Resolved
RE-WORK FUEL OIL SUPPLY AND RETURN LINE BETWEEN FUEL OIL DAY TANK AND HALIBURTON SKID UNIT. NO SECTION OF NON-METALIC FLEXIBLE FUEL LINES TO EXCEED 30" IN LENGTH.
Condition: Unknown
Due 17 September 1999
Resolved 13 September 1999
Construction/Loadline
Issued 24 August 1998
Resolved
COMPLETE PHASE II OF SEILDD.
Condition: Unknown
Due 24 August 1998
Resolved 24 August 1998
Lifesaving
Issued 20 August 1997
Resolved
CONDUCTED TOTAL RIG SHUTDOWN FROM ALL SWITCH LOCATIONS. WHILE TEST IS BEINGCONDUCTED TEST EMERGENCEY GEN FOR ONE HOUR.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Documentation
Issued 24 April 1997
Resolved
CONDUCT DEADWEIGHT SURVEY PER MSC REQUIREMENT OF LETTER DATED 21APR97, SER#HI-9701251.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 7 October 1996
Resolved
Crop and renew uppper barkets in aft bulkhead at frame 13 of Drill Water tank #6. Number 4,5,6 counting from outboard.
Condition: Unknown
Due 7 October 1996
Resolved 28 October 1996
Documentation
Issued 7 October 1996
Resolved
Provide copy of ABS inspection report on spud can and installation of new genset/top drive systems.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Documentation
Issued 7 October 1996
Resolved
Provide data as required to determine lightship changes per standards of Marine Safety Technical Note 04-95.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Construction/Loadline
Issued 7 October 1996
Resolved
Complete Phase II (leg to can) inspection and provide proposal for inspection.
Condition: Unknown
Due 7 October 1996
Resolved 28 October 1996
Construction/Loadline
Issued 7 October 1996
Resolved
Crop and renew wasted metal in way of man hole of transverse bulkhead at frame 11 in Drill Water #6.
Condition: Unknown
Due 7 October 1996
Resolved 28 October 1996
Documentation
Issued 7 October 1996
Resolved
Provide a copy of NDT and diver reports on spud can inspection.
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Construction/Loadline
Issued 24 August 1996
Resolved
GAUGE & MAKE REPAIR PROPOSAL FOR THE FIRST FOUR WASTED HORIZONTAL STIFFENERS ON THE BOTTOM OF PRELOAD TANK #2 ON THE OUTBOARD SIDE SHELL.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
GAUGE & MAKE REPAIR PROPOSAL FOR RENEWAL OF WASTED SIDE SHELL STIFFENERS INFORWARD OUTBOARD SECTION OF PRELOAD TANK #2 AT FRAME #19.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
COMPLETE WELDING REPAIRS TO NEW OVERHEAD PLATING IN DRILL WATER TANK #5.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
INSTALL STRAINER ON MAIN SEA CHEST VALVE.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
MAKE READY FOR INTERNAL EXAM DRILL WATER TANKS #6-8.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
REPLACE AS NECESSARY ALL WASTED LADDER RUNGS IN PRELOAD TANKS #1A, 2A & 3.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
REPLACE WASTED REACH RODS IN PRELOAD TANKS #1A & 2.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
FREE UP STIFF CHECK VALVE IN PRELOAD TANK #1.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
ENSURE CHECK VALVES IN PRELOAD TANKS #1 & 3 CLOSE COMPLETELY.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
REPAIR SIDE SHELL INSET & WASTED FRAMES AS MARKED IN PRELOAD TANK #3.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Construction/Loadline
Issued 24 August 1996
Resolved
MAKE PROPER INSERT REPAIR TO INSET AT PRELOAD TANK #2 BILGE KNUCKLE BETWEENFRAMES #22 & 23 ON OUTBOARD SIDE. RENEW ALL BROKEN STIFFENERS IN SAME AREA.
Condition: Unknown
Due 24 August 1996
Resolved 24 August 1996
Fire Fighting
Issued 28 September 1994
Resolved
PROVIDE COAST GUARD APPROVAL OF CO2 INSTALLATION IN MOTOR ROOM.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Fire Fighting
Issued 28 September 1994
Resolved
PROVIDE CLASS A DOOR FOR THIRD DECK DOORWAY TO STAIRWELL.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 28 September 1994
Resolved
CORRECT THE FOLLOWING ITEMS FOR LIFEBOAT #1: OVERHAUL/REPAIR CORRODED SEATBELTS, PROVIDE 12 ADD'L BAGS OF WATER, PROVIDE ADD'L PAINTER, RENEW LIFELINE.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 28 September 1994
Resolved
CORRECT THE FOLLOWING ITEMS FOR LIFEBOAT #2: REPAIR AFT INTERNAL LAMP, REPAIR HELM WINDOW, PROVIDE ADD'L PAINTER.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 28 September 1994
Resolved
PROVIDE SIX ADD'L HAND HELD PARACHUTE FLARES FOR RIG.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 28 September 1994
Resolved
RESTENCIL PERSONNEL CAPACITY ON ALL FOUR LIFERAFTS.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 28 September 1994
Resolved
RENEW FLEXIBLE DISCHARGE HOSE FOR CO2 SYSTEM FOR PAINT LOCKER.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Engineering
Issued 15 February 1994
Resolved
CRANE BREAKER PANEL DESTROYED ALONG WITH NUMEROUS OTHER BREAKERS.
Condition: Unknown
Due 8 January 2002
Resolved 8 January 2002
Resolution: Cleared to update vsl file
Electrical
Issued 24 August 1993
Resolved
INSTALL PURGE INDICATOR ON AUX. MUD PUMP CONTROLLER ON DRILLERS CONSOLE.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Electrical
Issued 24 August 1993
Resolved
PROVE PROPER OPERATION OF TORQUE GAUGE PURGE INDICATOR.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Electrical
Issued 24 August 1993
Resolved
PROVIDE EXPLOSION PROOF J-BOX FOR 440V PLUG/RECEPTACLE PORT SIDE DRILL FLOOR.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Construction/Loadline
Issued 24 August 1993
Resolved
MAKE MASTER DUMP VALVE, CANS, AND LEG TO CAN CONNECTIONS AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Deck/Cargo
Issued 24 August 1993
Resolved
CROP, RENEW, AND HYDRO BULK AIR DRYER.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 24 August 1993
Resolved
RENEW MARKINGS ON BOTH LIFEBOATS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 24 August 1993
Resolved
PROPERLY MARK ALL GENERAL ALARM BELLS AND CONTACT MAKERS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Electrical
Issued 24 August 1993
Resolved
INSTALL EXPLOSION PROOF MOTOR FOR MUD PIT EXHAUST FAN.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Navigation
Issued 24 August 1993
Resolved
PROVIDE STERN LIGHT.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 24 August 1993
Resolved
HYDRO ALL AIR BOTTLES IN BOTH LIFEBOATS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 24 August 1993
Resolved
REPAIR HELO DECK PERIMITER LIGHTS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 24 August 1993
Resolved
REPAIR BOTH OXYGEN METERS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 24 August 1993
Resolved
OPERATE BOTH LIFEBOATS IN THE WATER.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Unknown
Issued 24 August 1993
Resolved
MAKE RIG AIR RECEIVERS AND RELIEF VALVES AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 24 August 1993
Resolved
MAKE MUD PIT DOORS TO OPEN INTO MUD PUMP ROOM, SELF CLOSING, AND GAS TIGHT.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Electrical
Issued 24 August 1993
Resolved
PROVE PROPER OPERATION OF ALL REMOTE SHUTDOWNS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 1 October 1991
Resolved
RENEW SMOKE SIGNAL FOR RING BUOY LOCATED AT PORT LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1991
Resolved 19 November 1991
Electrical
Issued 1 October 1991
Resolved
PROVIDE AN APPROVED HAZARDOUS LOCATIONS GENERAL ALARM BELL IN THE MUD PITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1991
Resolved 19 November 1991
Deck/Cargo
Issued 1 October 1991
Resolved
MAKE APPROVED REPAIRS TO DRY BULK TANK ON MAIN DECK, SERIAL# 12025, IN AREAOF HEAVY PITTING IN LOWER PORTION OF TANK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Lifesaving
Issued 1 October 1991
Resolved
PROVIDE EMBARKATION LIGHT FOR STBD LIFERAFT STATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Engineering
Issued 1 October 1991
Resolved
RENEW RELIEF VALVE FOR AIR RECEIVER #106086 IN MACHINERY SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Lifesaving
Issued 1 October 1991
Resolved
REPLACE GENERAL ALARM ON DRILL FLOOR WITH GENERAL ALARM APPROVED FOR HAZARDOUS LOCATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1991
Resolved 19 November 1991
Deck/Cargo
Issued 28 August 1991
Resolved
HYDRO AND INTERNALLY EXAMINE AIR RECEIVERS AND BULK TANKS. TEST AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Lifesaving
Issued 28 August 1991
Resolved
POST NEW FIRE CONTROL PLAN.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Lifesaving
Issued 28 August 1991
Resolved
WEIGHT TEST LIFEBOATS #1 & #2, OPERATE LIFEBOATS IN WATER, TEST WATER SPRAYSYSTEM, INSPECT LIFEBOAT WINCHES, DAVIT ASSEMBLIES AND DISENGAGING APPARATUS.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Lifesaving
Issued 28 August 1991
Resolved
RENEW LIFELINES ON RING BOUYS LOCATED AT #1 LIFEBOAT STATION AND STBD LIFERAFT STATION.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Lifesaving
Issued 28 August 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Navigation
Issued 28 August 1991
Resolved
REPAIR STARBOARD NAV. LIGHT (WATER TIGHT).
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Electrical
Issued 28 August 1991
Resolved
SECURE MUD AGITATOR WIRE IN MUD PIT.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Lifesaving
Issued 28 August 1991
Resolved
TEST TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Electrical
Issued 28 August 1991
Resolved
WOOD BLOCK GENERAL ALARM BATTERIES.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Engineering
Issued 28 August 1991
Resolved
REPLACE OIL TRANSFER HOSE WITH A HOSE RATED FOR OIL SERVICE.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Lifesaving
Issued 28 August 1991
Resolved
REPLACE BATTERY IN EPIRB.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Deck/Cargo
Issued 28 August 1991
Resolved
REPLACE LOAD RATING CHART ON AFT CRANE CONTROL BOX.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Electrical
Issued 28 August 1991
Resolved
REPLACE WIRE ON SHALE SHAKER GAS DETECTOR WITH ARMORED OR [name withheld].
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Electrical
Issued 28 August 1991
Resolved
RELABLE FIRE STATIONS 1,5 AND 12.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Electrical
Issued 28 August 1991
Resolved
LABEL CIRCUIT BREAKER #24 IN A/C PANEL 220 AND IN CRANES.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Electrical
Issued 28 August 1991
Resolved
TEST EMERGENCY LIGHTS AND GENERAL ALARM BELLS. CONDUCT 2 HOUR LOAD TEST ON GENERAL ALARM BATTERIES DURING TEST.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Accommodation/Occupational Safety
Issued 28 August 1991
Resolved
MAKE BOTH GAS TIGHT DOORS TO MUD PIT SELF CLOSING.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Construction/Loadline
Issued 28 August 1991
Resolved
PROPERLY SEAL BULKHEAD PENETRATIONS TO MUD PIT ROOM.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Unknown
Issued 14 August 1990
Resolved
PROVIDE LAST HYDROSTATIC TEST DATE FOR BOTH FIXED AND PORTABLE FIREFIGHTINGSYSTEMS/EXTINGUISHERS. TO BE COMPLETED TO THE SATISFACTION OF THE [name withheld], TX.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
UPDATE FIRE AND LIFESAVING PLAN TO MATCH ACTUAL EQUIPMENT ONBOARD. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
STRIP AND CLEAN BOTH LIFEBOATS. TO BE COMPLETED TO THE SATISFACTION OF THEOCMI, PORT ARTHUR, TX.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
END-FOR-END FALLS FOR PORT LIFEBOAT. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
INSTALL APPROVED NAVIGATION LIGHTS AND TEXTURES. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
HAVE ALL LIFERAFTS SERVICED BY AN APPROVED FACILITY, PROVIDE PROOF OF SERVICING TO [name withheld].
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
PROVIDE DOCUMENTATION OF ANNUAL WEIGHT TESTS (WITH WEIGHTS LISTED) FOR FIXED CO2 CYLINDERS. TO BE COMPLETED TO THE SATISFACTION OF THE [name withheld], TX.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
REPLACE COVER ON TOP OBSTRUCTION LIGHT ON BOW. TO COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
PROVIDE CURRENT CRANE EXAM CERTIFICATES FOR ALL CRANES. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Unknown
Issued 14 August 1990
Resolved
PROVIDE ONBOARD 12 RED ROCKET PROPELLED FLARES VICE HAND-HELD FLARES. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Fire Fighting
Issued 30 August 1989
Resolved
HAVE HYDROSTATIC TEST OF NITROGEN CYLINDER FOR HELO DECK B-V FIRE EXT. CONDUCTED.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989
Resolved
DEMONSTRATE PROPER OPERATION OF MUD PUMP RELIEF VALVES ON BOTH MUD PUMPS IAW 46 CFR 54.15-10.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
REPLACE MISSING GUARD ON #2 DC GENERATOR BLOWER MOTOR IAW 46 CFR 58.60-13.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
REMOVE GROUND INDICATION FROM MAIN AC SWITCHBOARD (GROUND IS SUSPECTED TO BE IN INBOARD SUBMERSIBLE PUMP MOTOR) IAW 46 CFR SUBPART 111.05.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
RESTORE TO PROPER OPERATION EMERGENCY LIGHTS IN THE FOLLOWING MACHINERY SPACE LOCATIONS: (A)OVER #4 GENERATOR (B)OVER DC DISTRIBUTION PANEL. REPAIRSHORTS TO EMERGENCY LIGHTS AT #28 FIRE STATION ON 2ND DECK AND BETWEEN RMS 303 AND 304 IAW 46 CFR 112.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Engineering
Issued 30 August 1989
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION / OR HYDROSTATICALLY TEST DRILL FLOOR AIR RECEIVER AND DEMONSTRATE PROPER OPERATION OF RELIEF VALVE IAW 46 CFR 61.10-5.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Documentation
Issued 30 August 1989
Resolved
PROVIDE PROOF OF APPROVED FIRE CONTROL PLAN AND CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
INSTALL JUNCTION BOXES FOR NEW WIRING INSTALLATION IN OVERHEAD OF 2ND DECK TV ROOM (OLD MESS DECK).
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
REMOVE DEAD END WIRE FROM BULKHEAD IN OLD GALLEY ON 2ND DECK ADJACENT TO FIRE STATION #32.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Engineering
Issued 30 August 1989
Resolved
MAKE AVIALABLE FOR INTERNAL INSPECTION / OR HYDROSTATICALLY TEST BARITE TANK "B" AND CEMENT TANK "D" AND DEMONSTRATE PROPER OPERATION OF RELIEF VALVES IAW 46 CFR 61.10-5.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Fire Fighting
Issued 30 August 1989
Resolved
LABEL BOTH SUBMERSIBLE PUMP MOTOR CONTROLLERS AS "FIRE PUMP".
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989
Resolved
RENEW FLEXIBLE RUBBER COUPLING ON INBOARD SUBMERSIBLE PUMP PIPING.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Unknown
Issued 2 September 1987
Resolved
REPAIR OR REPLACE THE WASTED METAL ON THE RED FOX SANITARY SYSTEM.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Electrical
Issued 2 September 1987
Resolved
REPLACE OR REPAIR THE BATTERY BOX FOR THE GENERAL ALARM BATTERIES.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Electrical
Issued 2 September 1987
Resolved
TEST THE OVERSPEED SHUTDOWN ON DIESEL NO. 1.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Electrical
Issued 2 September 1987
Resolved
TEST THE HIGH TEMPERATURE ALARMS ON NUMBERS 1, 2, 3, AND 4 DIESELS.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Unknown
Issued 2 September 1987
Resolved
MAKE THE AIR TANK ON THE DRILL FLOOR AVAILABLE FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Unknown
Issued 2 September 1987
Resolved
MAKE THE BULK TANKS AVAILABLE FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Navigation
Issued 2 September 1987
Resolved
REPLACE THE LENSE COVER ON THE TOP (BOW) OBSTRUCTION LIGHT AND REPAIR INOPERATIVE LOWER OBSTRUCTION LIGHT ON THE PORT SIDE.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Lifesaving
Issued 2 September 1987
Resolved
CONDUCT WEIGHT TEST OF BOTH LIFE CAPSULE DAVITS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Lifesaving
Issued 2 September 1987
Resolved
CONDUCT MANUFACTURER AUTHORIZED REPAIRS TO THE PORT SIDE LIFE CAPSULE IN WAY OF THE STEERING DOME AND THE BASE OF THE PORT SIDE CANOPY SUPPORT.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Navigation
Issued 2 September 1987
Resolved
REPAIR OR REPLACE THE AUTOMATIC FOG HORN LOCATED ON THE ROOF OF THE JACKHOUSE.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Lifesaving
Issued 2 September 1987
Resolved
PLACE ON BOARD 6 ADDITIONAL PARACHUTE FLARES WITH VALID EXPIRATION DATES PRIOR TO MOVING RIG.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Fire Fighting
Issued 2 September 1987
Resolved
PROVIDE EVIDENCE THAT THE FIXED EO2 SYSTEM FOR THE PAINT LOCKER HAS BEEN SERVICED.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Unknown
Issued 2 September 1987
Resolved
REPAIR OR REPLACE THE DEFECTIVE PRESSURE SWITCH FOR THE PURGE AIR SYSTEM UNABLE TO DETECT LOSS OF AIR PRESSURE TO SYSTEM, TO ENSURE THAT SYSTEM IS PRESSURIZED. INSPECTIONS MUST BE MADE FREQUENTLY AND LOGGED ACCORDINGLY.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Documentation
Issued 25 September 1986
Resolved
PENDING COMPLETION OF THE ABOVE REPAIRS PROVIDE ON BOARD AND MAKE AVAILABLETO ALL CRANE OPERATORS, ANY REDUCTIONS IN LIFTING CAPACITIES RECOMMENDED BYTHE MANUFACTURER FOR THE ABOVE CRANES. THE RECOMMENDED CAPACITIES SHALL NOTBE EXCEEDED.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Deck/Cargo
Issued 25 September 1986
Resolved
EFFECT PERMANENT REPAIRS TO APPARENT FRACTURES IN THE PEDISTALS FOR THE PORT AND AFTER CRANES. FRACTURES ARE LOCATED APPROXIMATELY 6"-12" BELOW THE SWING GEAR IN WAY OF THE CONNECTING BRACKETS. REPAIRS SHALL BE IN- ACCORDANCE WITH MANUFACTURERS REPAIR PROCEDURES.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Lifesaving
Issued 6 September 1985
Resolved
TEST OPERATION AND WEIGHT TEST #1 SURVIVAL CAPSUL
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Lifesaving
Issued 6 September 1985
Resolved
SERVICE ALL HYDROSTATIC RELEASES FOR LIFE RAFTS AND PROVIDE #2 LIFE RAFT ON BOARD
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Navigation
Issued 6 September 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Lifesaving
Issued 6 September 1985
Resolved
PROVIDE 1500' OF AUXILARY LINE FOR LINE THROWING APPLIANCE
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Fire Fighting
Issued 6 September 1985
Resolved
PROVIDE A FIRE AXE, EXPLOSIVE GAS DETECTOR, AND OXYGEN DETECTOR FOR EACH FIREMANS OUTFIT
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Lifesaving
Issued 6 September 1985
Resolved
PROVIDE 7 PARACHUTE FLARES TO MAKE A TOTAL OF 12
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Unknown
Issued 13 November 1984
Resolved
INSTALL ASME APPROVED SAFETY RELIEF VALVES ON EACH P-TANK.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Documentation
Issued 13 November 1984
Resolved
PROVIDE AN OIL POLLUTION PLACARD AND POST THE SAME.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Fire Fighting
Issued 13 November 1984
Resolved
MAKE NECESSARY REPAIRS TO ENSURE THAT EACH FIRE PUMP CAN DELIVER WATER AT ACONTINUOUS PITOT PRESSURE OF AT LEAST 40 PSI FROM A MINIMUM OF TWO FIRE HOSE NOZZLES THAT ARE CONNECTED TO THE HIGHEST TWO FIRE HYDRANTS ON THE UNIT.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Lifesaving
Issued 13 November 1984
Resolved
PROVIDE AN AUDIBLE ALARM IN THE SACKROOM AND A VISUAL ALARM IN THE GENERATOR ROOM.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
CHANGE THE GLASS PLATE IN THE REMOTE SHUTDOWN BOX AND PROVIDE A KNOCKER FORTHE VENTILATION SYSTEM.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Electrical
Issued 13 November 1984
Resolved
PROVIDE EYS FITTINGS IN THE DESIGNATED HAZARDOUS LOCATIONS ON THE DRILL FLOOR AND BELOW THE FLOOR.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
PROVIDE A BELT GUARD FOR THE DRILL PRESS AND COLD START AIR COMPRESSOR.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
DESIGNATE THE MASTER IN WRITING.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Lifesaving
Issued 13 November 1984
Resolved
CHANGE THE FUEL IN LIFEBOAT NUMBER TWO.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Lifesaving
Issued 13 November 1984
Resolved
PROVIDE SEVEN (7) MORE CANS OF WATER AND SEVEN (7) CANS OF PROVISIONS FOR LIFEBOAT NUMBER TWO.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Lifesaving
Issued 13 November 1984
Resolved
POST THE LAUNCHING INSTRUCTIONS AT ALL LIFERAFT STATIONS.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Fire Fighting
Issued 13 November 1984
Resolved
PROVIDE A SECOND FIREMAN'S OUTFIT.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Fire Fighting
Issued 13 November 1984
Resolved
PROVIDE FIVE TYPE A SIZE II FIRE EXTINGUISHERS FOR THE LIVING QUARTERS AND STOREROOMS.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
PROVIDE REMOTE SHUTDOWN CAPABILITY FOR THE FUEL OIL TRANSFER PUMPS IN THE GENERATOR ROOM.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
RESET THE OVERSPEEDS ON FIVE (5) GENERATORS TO ACCEPTABLE LIMITS, AND TEST SAME IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
REPAIR THE OVERSPEED DEVICE ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
LABEL THE MOTOR CONTROLLERS THROUGHOUT THE ENGINE SPACES.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 November 1984
Resolved
STENCIL ALL EMERGENCY LIGHTING THROUGHOUT THE RIG WITH A RED LETTER "E".
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984