Records from 1991 to 2026. Most recent: inspection, 20 July 2026.
Documentation record
Registered dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
ITC tonnagegross 219 / net 65
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
219 - Convention (Subpart B), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
65 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 51
20 July 2026
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8442646
30 September 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8244428
6 August 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8204111
25 July 2024
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7966803
28 November 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7830396
31 August 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7781899
30 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7602324
24 November 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7356775
11 August 2021
Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7282339
18 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7096907
18 April 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6974753
19 August 2019
Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6792640
15 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6142575
19 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4818507
26 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4391419
18 June 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4347714
13 June 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4342960
5 January 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3920925
16 December 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3914783
3 December 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3903844
23 July 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3543126
21 July 2009
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3541340
17 July 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3540938
28 January 2009
Internal Structural Exam · Construction Oversight · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3401332
30 September 2008
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3335883
21 May 2007
Examination of Repairs · Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2936689
19 June 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2685277
21 June 2005
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2397023
24 August 2004
Administrative Inspection · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2174504
30 January 2004
Examination of Repairs · Damage Survey
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1997900
29 January 2004
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1997379
24 June 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1825239
24 June 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1635733
16 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1479948
22 June 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362256
17 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439075
3 June 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468069
25 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381269
10 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114130
11 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780400
6 June 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421357
18 March 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 774604
11 June 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371422
16 June 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355298
28 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 63183
5 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1178739
22 July 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1178059
23 June 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1332535
23 June 1993
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461523
23 June 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1268436
24 June 1991
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification · Plan Review "T" Boat
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252537
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2025
Resolved
At all inspections special attention shall be paid to ensure that no fire hazards exist. Vessel's port generator's oil pressure sensor was leaking fluid and significant amount of oil was present under both generators.
46 CFR 176.25-10(b)Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 7 August 2025
Resolution: Provided proof of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 August 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed hazardous places such as rotating machinery. Port generator's crankshaft pulley was not protected by a cover, guard, or rail.
46 CFR 177.35-15 Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 7 August 2025
Resolution: Guard installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 August 2025
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to determine they are in operating condition such as generators. Vessel's starboard generator was unable to start.
46 CFR 176.25-15
Action required: 10 - Deficiency Rectified
Resolved 7 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 November 2022
Resolved
Buoyant apparatus must not have any evident defects in workmanship. Port Life buoy had hole in outer shell.
Action required: 10 - Deficiency Rectified
Due 30 November 2022
Resolved 30 November 2022
Resolution: replaced life float
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2022
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Port exhaust bracket was cracked
Action required: 10 - Deficiency Rectified
Due 30 November 2022
Resolved 30 November 2022
Resolution: welder fixed crack
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 November 2022
Resolved
If individual wires, rather than cable are used in systems greater than 50 volts, wire must be in conduit.
Conduit on wiring going into pressure switch on potable water head tank was not installed
Action required: 10 - Deficiency Rectified
Due 30 November 2022
Resolved 30 November 2022
Resolution: removed and sealed dead-end wire
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 November 2022
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precautions against hazards that might endanger the vessel and the persons being transported. Dead end wire (cut and exposed) located in between engine room and laundry space.
Action required: 10 - Deficiency Rectified
Due 30 November 2022
Resolved 30 November 2022
Resolution: dead-end wire was fixed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 November 2022
Resolved
Watertight bulkheads must be capable of remaining watertight. Copper piping cut on both ends between laundry and galley, leaving three openings between spaces.
Action required: 10 - Deficiency Rectified
Due 30 November 2022
Resolved 30 November 2022
Resolution: pipe was removed and hole was sealed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 November 2022
Resolved
Weathertight door must be provided for each opening located in a deck house. Wire penetration located in deck house was not weathertight
Action required: 10 - Deficiency Rectified
Due 30 November 2022
Resolved 30 November 2022
Resolution: penetrations were sealed
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 November 2021
Resolved
All machinery and equipment must be maintained to afford adequate protection from causing fire and machinery failure; hoses on each of the MDE's were chaffing. Chaffing protection was added on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 November 2021
Resolution: Chaffing protection added in noted locations.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 November 2021
Resolved
Rotating machinery must be properly protected by cover, guard, or rail; MDE #3 had exposed rotating machinery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 November 2021
Resolution: Guard added over rotating machinery.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 November 2021
Resolved
All machinery and equipment must be maintained to afford adequate protection from causing fire; port generator fuel fileter was missing flame shield.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 November 2021
Resolution: Flame shield added.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 November 2021
Resolved
Exhaust piping must be properly supported; two hanger bolts were missing in the support of exhaust piping for MDE #1. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 November 2021
Resolution: Hanger bolts added.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 November 2021
Resolved
A vessel must carry up-to-date charts; charts were missing most recent three (03) weeks of corrections from NTM, corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 November 2021
Resolution: Chart corrections made.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 March 2009
Resolved
Procure and maintain onboard updated light list.
Due 30 April 2009
Resolved 21 July 2009
Resolution: Corrections were made to the satisfactory of the attending Marine Inspector.
Engineering › Pressure Vessel › Relief Valve
Issued 31 March 2009
Resolved
Pressure relief valve for hot water heater must have 100 psi prv vice the 150 psi prv that is installed. Replace prv.
Due 30 April 2009
Resolved 21 July 2009
Resolution: Corrections were made to the satisfactory of the attending Marine Inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 31 March 2009
Resolved
1 one lifering was unservicable. Replace with a new one.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2009
Lifesaving › Rescue Boat › Length
Issued 21 May 2007
Resolved
Rescue platform was 24" from the waterline while deployed. Required repairs were made to ensure it reached below the waterline while in a loaded condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2007
Engineering
Issued 17 August 2000
Resolved
REPLACE CHAFED FUEL LINE ON NO.2 MAIN ENGINE.
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Engineering
Issued 17 August 2000
Resolved
REPLACE CHAFED NO.2 REDUCTION GEAR OIL LINE TO PRESSURE GAUGE.
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Engineering
Issued 17 August 2000
Resolved
REWELD PORT GENERATOR EXHAUST PIPING AT THROUGH HULL PENETRATION.
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Navigation
Issued 17 August 2000
Resolved
PROVIDE POSITIVE MEANS OF SECURING TWO RUDDER PINS.
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Documentation
Issued 23 June 1994
Resolved
RE-MARK VESSELS LOADLINE PLIMSOLL THAT HAS PARTIALLY WORN OFF STBD SIDE OF HULL.
Condition: Unknown
Due 23 July 1994
Resolved 22 July 1994
Navigation
Issued 23 June 1994
Resolved
PROVIDE A SECOND VHF-FM RADIO AS REQUIRED BY FCC REGULATION 47 CFR 80.1017_x001C_TO COMPLY WITH BRIDGE TO BRIDGE AND VHF CH.16 MONITORING REQUIREMENTS.
Condition: Unknown
Due 23 July 1994
Resolved 22 July 1994
Lifesaving
Issued 23 June 1994
Resolved
PROVIDE ON BOARD VESSEL, DOCUMENTATION THAT THE VESSELS CREW IS ENROLLED INA RANDOM TESTING PROGRAM AS REQUIRED BY 46 CFR 16.230. THIS INFORMATION IS TO BE CURRENT, FOR CREW MEMBERS ONBOARD DURING ANY COAST GUARD EXAMINATION. _x001C_
Condition: Unknown
Due 23 July 1994
Resolved 22 July 1994
Documentation
Issued 23 June 1994
Resolved
VESSELS ONBOARD LOADLINE CERT.ISSUED 02DEC91, WITH AN EXPIRATION OF 30JUN96CURRENTLY IS INVALID. LOADLINE CERT. HAS NOT BEEN ENDORSED SINCE ORIGINAL ISSUANCE AS PER 46 CFR 42.09-15(d). "VESSELS SUBJECT TO PERIODIC SURVEYS SHALL HAVE THEM WITH THREE MONTHS OF THE CERTIFICATES ANNIVERSARY DATE.
Condition: Unknown
Due 23 July 1994
Resolved 22 July 1994
Engineering
Issued 23 June 1993
Resolved
INSTALL PROPER ASME APPROVED REFIEF VALVES ON BOTH AIR RECIEVERS.
Condition: Unknown
Due 23 July 1993
Resolved 1 July 1993