Records from 1984 to 2017. Most recent: inspection, 2 March 2017.
Inspection history · 168
2 March 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6098126
17 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5974883
16 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5974636
16 August 2016
Damage Survey · Construction Oversight · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5979690
22 October 2015
Hull Examination · Underwater Inspection in lieu of Drydock
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5761069
27 August 2015
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5748043
16 July 2015
DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5183958
5 August 2014
Type not recorded
No type recorded · Station Lake Tahoe · USCG Southwest District (CGD-SW) · Activity 4945036
4 August 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4944253
4 August 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4946846
4 August 2014
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4946933
12 June 2014
MTSA Verification · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4877803
21 May 2012
Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4318173
21 May 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4318188
21 May 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4321676
20 December 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4423538
22 July 2011
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4096182
13 October 2010
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3869273
22 February 2010
Deadweight Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3683944
14 April 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3450044
2 September 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3316250
17 June 2008
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3242953
7 April 2008
Inclining Experiment · Construction Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3179363
30 May 2007
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2952208
30 May 2007
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2966434
24 May 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2951225
20 March 2007
COI Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2883331
5 January 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2850987
25 April 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2629563
2 November 2005
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2526946
2 August 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2449343
1 July 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2431048
29 June 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2410529
1 June 2005
Liferaft Servicing
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2376213
3 May 2005
Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353140
11 February 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2291047
10 February 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2292213
11 November 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2239540
2 November 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2233414
10 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2167667
30 July 2004
Damage Survey · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2150798
29 July 2004
MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2134483
20 June 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2109245
18 May 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2060698
11 May 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2072498
11 May 2004
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2073198
17 February 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2008088
9 February 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2003929
8 July 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1840054
20 May 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1751957
24 June 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1635940
1 May 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1611626
29 March 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1597461
13 March 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1493546
15 January 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1478702
16 October 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1074544
16 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075577
6 September 2001
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1465062
5 September 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 143587
25 April 2001
Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373475
1 February 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1059433
4 January 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1397547
27 July 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1389159
25 July 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 167198
21 June 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 819283
1 May 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1369653
22 April 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 49474
20 October 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 76035
30 March 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1085816
26 January 1999
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 791240
11 December 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 811281
24 June 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1127657
19 May 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126373
15 July 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 780673
23 May 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1425906
13 May 1997
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103075
15 April 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1110163
9 February 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1106613
23 January 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1110171
20 December 1996
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870053
14 November 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1183092
6 September 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 12616
6 September 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948741
6 August 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1091910
18 July 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1086496
18 July 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1087179
9 May 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1084400
9 May 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1085181
3 April 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1078467
16 February 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 212144
2 February 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1465235
23 December 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1187683
7 November 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1184132
26 October 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 77581
26 September 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1394396
20 September 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 154541
3 September 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 46092
26 June 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880093
20 June 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880951
18 June 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 25088
29 May 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 151470
2 May 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1338423
5 April 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 841649
1 April 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 118843
29 March 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 181682
12 February 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 20080
29 November 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 867902
29 November 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871320
22 November 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 863899
19 October 1994
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 862366
14 October 1994
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861883
30 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 867068
28 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 170354
24 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 159131
7 September 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1180567
25 August 1994
Examination of Repairs · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1448577
23 August 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 172421
5 August 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 864529
15 July 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 869896
29 June 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 869220
10 June 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861886
5 April 1994
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 856238
25 February 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164682
28 January 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 32257
19 November 1993
Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1434079
21 October 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156099
12 October 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658415
4 October 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156837
4 August 1993
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848049
29 July 1993
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156678
28 July 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1158407
12 June 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 140521
25 May 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1443380
20 May 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658416
30 April 1993
Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 836973
6 April 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 827937
30 March 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834752
8 February 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137435
15 December 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 961067
30 September 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262007
25 August 1992
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1247431
23 August 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 140858
10 August 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 111511
12 May 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257969
6 April 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1258343
29 February 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1261656
13 February 1992
Examination of Repairs · Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 955200
19 January 1992
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 941664
18 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 27191
16 January 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006301
1 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 96316
1 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 107389
29 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 160738
20 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 936143
20 August 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 941349
18 June 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230390
8 April 1991
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 918025
21 May 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220185
10 April 1990
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 918279
18 April 1989
COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1199060
29 November 1988
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1343953
25 August 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043014
14 July 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1031566
20 April 1988
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1196704
13 October 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018198
9 August 1987
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1339384
8 August 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1307307
17 August 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977056
Construction/Loadline › Hull › Bottom Plating
Issued 16 August 2016
Resolved
Vessel operator shall post 24 hour live watch to monitor vessel condition. Vessel operator shall place hull reference marks on hull visible from pier and immediatly report any changes in trim or list to the USCG
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 12 January 2017
Construction/Loadline › Hull › Bottom Plating
Issued 16 August 2016
Resolved
Vessel has a 4 foot by 4.5 foot section of hull cropped out below the waterline in way of port aft galley crossing aft bulkhead into aft compartment. The cofferdam installed in place shall remain in place and kept dry until hull penetartion is renewed to the satisfaction of the attending USCG marine inspector to allow final removal of cofferdam.
Action required: 705 - Other - as specified
Resolved 6 September 2016
Construction/Loadline › Penetrations › Valve Flange
Issued 22 October 2015
Resolved
Air Conditioning through hull valve could not be removed for inspection for AHE. Through hull was capped off until valve can be replaced and inspected.
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 January 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 October 2015
Resolved
Fire extinguisher mount in engine room was incorrect size for extinguisher. Replace with adequate mount for extinguisher size and type
Action required: 705 - Other - as specified
Due 22 November 2015
Resolved 15 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 22 October 2015
Resolved
Submit repair plan for hull plating identified during non-destructive testing to have more than 25% near starboard amidships.
Action required: 705 - Other - as specified
Due 22 November 2015
Resolved 15 January 2016
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 July 2015
Resolved
The bilge alarms in galley, ice room, and fuel compartment are connected twist on type connectors. Install proper crimp type connectors.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 28 September 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 July 2015
Resolved
The high level bilge alarm in fuel compartment is not permanently affixed. Install alarm float so it cannot shift.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 28 September 2015
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 July 2015
Resolved
Most wiring in engine room overhead is held in place to metallic supports with plastic retainers. Install proper metallic clamps where wiring (conductors) crosses metallic supports.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 28 September 2015
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 July 2015
Resolved
Misc 110 volt wiring throughout vessel is not properly supported. Provide proper support/strain relief.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 28 September 2015
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 August 2014
Resolved
Provide valid Certificate of Documentation onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2014
Resolution: Valid COD provided.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 4 August 2014
Resolved
Provide salvage plan for vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2014
Resolution: Salvage plan provided.
Construction/Loadline › Hull › Hull Plating
Issued 4 August 2014
Resolved
Provide 3rd party dive survey of hull post casualty.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2014
Resolution: Witnessed dive survey. Operator to send disk for permanent vessel record.
Electrical › Electric Supply System (service) › Cable
Issued 12 June 2014
Resolved
Ensure all electrical wiring is installed to marine standards/codes. All wiring must be marine grade, properly supported and splices must have pressure type connectors.
Condition: Improper Installation
Due 15 August 2014
Resolved 19 August 2014
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 June 2014
Resolved
Ensure exit's on 2nd deck are properly labeled and main deck illumination is working.
Condition: Improper/Lack of Maintenance
Due 1 July 2014
Resolved 6 August 2014
Resolution: New exit signs provided. illumination satisfactory.
Operations/Management › Drills/Instruction › Fire
Issued 12 June 2014
Resolved
Update station bill assigning a crew member to close engine room ventilation.
Condition: Design Flaw
Due 1 July 2014
Resolved 6 August 2014
Resolution: Revised station bill provided.
Operations/Management › Drills/Instruction › Fire
Issued 12 June 2014
Resolved
Conduct training to ensure all crew members are competent in preforming emergency duty's.
Condition: Design Flaw
Due 1 July 2014
Resolved 6 August 2014
Resolution: Satisfactory drill/training records provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 June 2014
Resolved
In the presence of a Marine Inspector satisfactorily conduct the following drills: Security, Fire and MOB.
Condition: Improper/Lack of Maintenance
Due 15 July 2014
Resolved 16 July 2014
Resolution: Completed MOB drill. Others drills to be completed at next annual.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Report of Potential Vessel Casualty
Issued 21 May 2012
Resolved
Provide proper operation of vessel's port paddle tire to the attending Coast Guard marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 May 2012
Resolution: Provided statement of proper operation of vessel''s port paddle tire.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 21 May 2012
Resolved
Submit statement from Captain of the TAHOE QUEEN of proper operation of port paddle tire after repair completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 May 2012
Resolution: Provided statement from [name withheld] of the TAHOE QUEEN of proper operation of port paddle tire after repair was completed.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 August 2011
Resolved 19 August 2011
Resolution: Received copy of MIS report.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 21 August 2011
Resolved 22 July 2011
Resolution: Training conducted, corrected on the spot.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 26 October 2010
Resolved
Provide cover for 4 x 4 electrical junction box in aft peak space port side on forward bulkhead.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 28 October 2010
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 26 October 2010
Resolved
Remove extension cord providing temporary power to a portable fluorescent lighting fixture in aft peak compartment on the PORT side.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 26 October 2010
Resolution: Fixed on the spot.
Stability › Weathertight Integrity › General
Issued 26 October 2010
Resolved
Replace corroded piping and missing gooseneck vent for the STBD aft Void.
Action required: 705 - Other - as specified
Due 31 December 2010
Resolved 28 December 2010
Construction/Loadline › Penetrations › Weld
Issued 26 October 2010
Resolved
Provide a repair proposal for the PORT and STBD spud wells above and below the waterline.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 30 November 2010
Resolution: Received and accepted repair proposal. See Documents.
Construction/Loadline › Hull › Side Shell
Issued 26 October 2010
Resolved
Provide maintenance proposal to arrest heavy scaling and corrosion in the Fuel Room Port H2O Void on the bottom plating, side shell and longitudinal stiffeners.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 November 2010
Construction/Loadline › Hull › Bottom Plating
Issued 26 October 2010
Resolved
Provide maintenance proposal to arrest heavy scaling & corrosion in Aft Peak at intersection of forward bulkhead and bottom plating at forward end of compartment.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 November 2010
Construction/Loadline › Penetrations › Weld
Issued 26 October 2010
Resolved
Repair PORT & STBD spud well structure.
Action required: 705 - Other - as specified
Due 31 December 2010
Resolved 28 December 2010
Construction/Loadline › Hull › Stiffener
Issued 26 October 2010
Resolved
Renew wasted vertical stiffener at ladder support in the #2 Hold.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 28 December 2010
Stability › Incline Test › General
Issued 25 May 2010
Resolved
Limit passenger count to 300 until new stability letter is issued from the Marine Safety Center, based on the results of the Deadweight Survey conducted on May 25, 2010.
Action required: 705 - Other - as specified
Resolved 10 November 2010
Stability › Incline Test › General
Issued 22 March 2010
Resolved
Provide updated deadweight survey with USCG approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2010
Resolution: See Plan Review Letter in document section of this activity. H2-1001205
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 April 2009
Resolved
Provide blanks for unfilled breaker slots in panel boards through out vessel.
Due 15 April 2009
Resolved 14 April 2009
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2009
Resolved
Properly bundle and support wiring in overhead of engine room which is hanging down.
Due 15 April 2009
Resolved 14 April 2009
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2009
Resolved
Hard wire in HVAC and emergency lights in engine room, forward of main generator.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 5 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2009
Resolved
Remove wirenuts and properly wire in aft compressor, (stbd side of refer room) and behind ice machine.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 5 May 2009
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 April 2009
Resolved
Properly label emergency escape (above and below) from Aft Peak.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 5 May 2009
Fire Fighting › Grease Extraction Hood › General
Issued 14 April 2009
Resolved
Galley range hood is excessively greasy - have professionally cleaned.
Due 15 May 2009
Resolved 5 May 2009
Fire Fighting › Fire Pumps › Arrangement
Issued 14 April 2009
Resolved
Demonstrate proper operation of engine driven fire pump.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 5 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2009
Resolved
Properly secure all (4) engine hot start junction boxes which are hanging by the power wires.
Due 15 April 2009
Resolved 14 April 2009
Resolution: Corrected on the spot.
Engineering › Bilge Water Management System › Not Operational
Issued 14 April 2009
Resolved
Properly mount bilge high water alarm float switches.
Due 15 April 2009
Resolved 14 April 2009
Stability › Incline Test › General
Issued 14 April 2009
Resolved
Noted that some of the ballast weights in #2 void were not secured properly and had shifted during heavy weather. Required vessel to secure all stacks of ballast with nylon ratchet straps.
Due 15 April 2009
Resolved 14 April 2009
Resolution: Corrected on the spot.
Fire Fighting › Fire Hoses › Location
Issued 17 June 2008
Resolved
Label fire station on main deck/aft and mount portable fire extinguisher inside.
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 20 July 2008
Resolution: Fire station labeled and portable fire extinguisher mounted.
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 17 June 2008
Resolved
Provide insulation on engine exhaust manifolds.
Action required: 705 - Other - as specified
Due 11 August 2008
Resolved 29 August 2008
Documentation › Logs/Records › Drug Test Records
Issued 17 June 2008
Resolved
Provide proof of drug and alcohol program.
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 20 July 2008
Resolution: Proof of DAPI audit provided.
Engineering › Lubricating Oil Service System › Gauge
Issued 17 June 2008
Resolved
Repair oil pressure gauge for main engines on navigation bridge.
Action required: 705 - Other - as specified
Due 11 August 2008
Resolved 29 August 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 17 June 2008
Resolved
Label aft peak emergency escape.
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 20 July 2008
Resolution: Emergency escape labeled.
Stability › Incline Test › General
Issued 7 April 2008
Resolved
Submit plans and procedures for approval to the Marine Safety Center to perform an intact stability test on board the M/V TAHOE QUEEN. After receipt of the approved procedures perform the test within 30 days. The vessel is restricted to 250 total passengers of which the 02 deck shall not exceed 50 persons, 100 persons on the 01 deck and 100 on the main deck.
Action required: 705 - Other - as specified
Resolved 8 September 2008
Documentation › Logs/Records › Drug Test Records
Issued 17 March 2008
Resolved
Background checks not conducted in accordance with 49 CFR 40.25.
Due 17 March 2008
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Company policy missing as required by 46 CFR part 16.401.
Due 29 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
MRO drug free determination before returning to work regulations not being followed as required in 49 CFR part 40; crewmember returned to work with only a letter from a SAP. Letter from MRO must be provided.
Due 29 June 2007
Resolved 17 March 2008
Resolution: Employee refered to in original deficency failed last return-to-work drug test and was fired. Company will follow proper protocol in the future.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 29 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Due 29 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 29 June 2007
Resolved 5 June 2007
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 29 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 30 May 2007
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 29 June 2007
Resolved 17 March 2008
Electrical › Electric Supply System (service) › Cable
Issued 20 March 2007
Resolved
Identified unauthorized cable (extension cord) hardwired to electrical outlet in galley for plate warming table. Vessel shall remove cable to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 20 March 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 March 2007
Resolved
Identified loose outlets and outlet box cover in galley, aft stbd staunchen. Vessel shall repair to original to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 20 March 2007
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 20 March 2007
Resolved
Identified forward water heater located in ice room is missing cover for juntion box and terminals. Vessel shall install cover to junction box to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 20 March 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 March 2007
Resolved
Vessel had COI posted in pilot house, inaccessible to passengers. Vessel required to post COI in location accessible to passengers.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 20 March 2007
Fire Fighting › Fire Main › Condition
Issued 25 April 2006
Resolved
Make permanent repairs to fire station on forecastle where holed.
Due 25 April 2006
Resolved 25 April 2006
Resolution: Replaced holed nipple.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 25 April 2006
Resolved
In accordance with the stability letter, properly label second and third decks with the maximum passenger capacity.
Due 25 May 2006
Resolved 5 January 2007
Stability › Weathertight Integrity › General
Issued 3 May 2005
Resolved
Renew broken window in way of port side main deck forward.
Due 3 July 2005
Resolved 29 June 2005
Stability › Weathertight Integrity › General
Issued 3 May 2005
Resolved
Renew the broken window in way of starboard side 2nd deck men's head.
Due 3 July 2005
Resolved 29 June 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 May 2005
Resolved
Repair the hand rail in way of the 2nd deck on starboard forward by the spud winch.
Due 3 July 2005
Resolved 5 May 2005
Fire Fighting › Fire Pumps › Casing
Issued 3 May 2005
Resolved
Replace the missing fire pump housing bolt in 2way of the engine room.
Due 3 July 2005
Resolved 5 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 3 May 2005
Resolved
Repair the hydraulic leak in way of the port engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2005
Resolved 3 May 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 3 May 2005
Resolved
Secured the bilge float switch in galley.
Due 3 July 2005
Resolved 3 May 2005
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 3 May 2005
Resolved
Properly secure the fixed ballast on the port side in the forepeak.
Due 3 July 2005
Resolved 3 May 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2005
Resolved
Properly separate the adult and child PFDs storage on the 3rd deck.
Due 3 July 2005
Resolved 3 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2005
Resolved
Replace twist on type with electric wire conductors and soldering lugs IAW 46CFR183.340
Due 3 July 2005
Resolved 3 May 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 3 May 2005
Resolved
Prove proper operation of the 2nd deck starboard men's head urinal
Due 3 July 2005
Resolved 3 May 2005
Electrical › Lighting (service) › Conductor
Issued 3 May 2005
Resolved
Properly wire the port aft compartment light.
Due 3 July 2005
Resolved 3 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 May 2005
Resolved
Renew the reflective tape on 3 adult PFDs.
Due 3 July 2005
Resolved 3 May 2005
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 11 February 2005
Resolved
Prove proper repair to the starboard paddle wheel shaft prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2005
Resolved 3 May 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 29 July 2004
Resolved
Properly label on both sides the emergency exit from the steering compartment to the main deck.
Action required: 705 - Other - as specified
Due 20 August 2004
Resolved 3 May 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 June 2004
Resolved
Renew as original two cracked paddle wheel observation windows in main deck passenger cabin aft.
Due 10 July 2004
Resolved 14 July 2004
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 25 June 2004
Resolved
Prove proper operation of pressure relief device on stbd hydraulic pump and renew damaged dischage hose from port side of stbd hydraulic pump to SAE J1942 standard prior operating stbd hydraulic pump while carrying pax for hire. Vsl is restricted to operating both paddles with the port hydraulic pump.
Due 10 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 18 May 2004
Resolved
Remove from service and vessel the (4) non- approved extension cords from band equipment area on lower deck. Provide training and oversight of non-crew band members on use of only approved extension cords on board vessel.
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Electrical › Electrical Distribution System (service)
Issued 18 May 2004
Resolved
Provide and install strain relief clamp on power supply wire to refrigeration system cooling water pump. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 18 May 2004
Resolved
Provide test method to demonstrate low oil pressure alarm and shutdown for main engines and generators.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 29 July 2004
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 18 May 2004
Resolved
Restow life jackets in new lockers so that child size life preservers are clearly seperated from adult life preservers.
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 18 May 2004
Resolved
Install permanent contrasting labels to identify the number of life preservers located in new staroge containers on upper deck.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 24 June 2004
Electrical › Electrical Distribution System (service)
Issued 18 May 2004
Resolved
Install cover plate to 110 volt outlet located upper deck bar area behind stanchen at forward bar area adjacent to coffee maker. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Navigation › Piloting/Steering
Issued 11 May 2004
Resolved
Vessel is not to operate until repair on starboard exterior paddle wheel hose is repaired to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Starboard Paddle Wheel Hydraulic Hose Rupture
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2004
Resolution: Vessel representatives had replaced ruptured 3000-psi hose with a 5000-psi hose and fittings. Hydraulic motor is rated at 3000-psi according to Port Engineer [name withheld]
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 May 2003
Resolved
Separate and properly stow child size lifejackets from adult size life jackets.
Due 20 May 2003
Resolved 20 May 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 May 2003
Resolved
Remove un-authorized temporary outlet plug located second deck bar as indicted by attending marine inspector.
Due 20 May 2003
Resolved 20 May 2003
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 May 2003
Resolved
Install cover for 110 volt outlet box located under first deck bar above sink as indicated by attending marine inspector.
Due 20 May 2003
Resolved 20 May 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 May 2003
Resolved
Properly secure wiring from strain and chafing for both forward winch motors.
Due 20 May 2003
Resolved 20 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 20 May 2003
Resolved
Provide and install poitive locking mechanism for sewege discharge piping. LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Due 23 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 May 2003
Resolved
Label unidentified circuit breaker located forward bulkhead bulkhead distribution panel in galley.
Due 23 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 May 2003
Resolved
Renew damaged 110 volt receptacle located on forward cook line in galley.
Due 23 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 May 2003
Resolved
Renew damaged circuit breaker located centerline on aft galley bulkhead.
Due 23 May 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 20 May 2003
Resolved
Remove stereo speaker clamped to fire extinguisher handle in galley.
Due 20 May 2003
Resolved 20 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 20 May 2003
Resolved
Remove hydraulic oil accumulation from forepeak bilge.
Due 20 May 2003
Resolved 20 May 2003
Stability › Intact Righting Energy
Issued 20 May 2003
Resolved
Properly secure lead ballast located in ballast void. LEGACY COMPONENT DESC: Ballast
Due 23 May 2003
Resolved 22 May 2003
Construction/Loadline › Penetrations
Issued 20 May 2003
Resolved
Make watertight two unused deck drain penetrations into ballast void from main deck. LEGACY COMPONENT DESC: Pipe Flange
Due 23 May 2003
Resolved 22 May 2003
Construction/Loadline › Structures
Issued 20 May 2003
Resolved
Renew to like new condition ballast void vent pipe. LEGACY COMPONENT DESC: Air Pipe
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 8 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 May 2003
Resolved
Repair fuel oil leak on starboard engine fuel filter and fuel oil pump as indicated by attending marine inspector.
Due 20 May 2003
Resolved 20 May 2003
Fire Fighting › Combustible Materials
Issued 20 May 2003
Resolved
Remove hydraulic oil accumulation in port aft battery box in engine room.
Due 20 May 2003
Resolved 20 May 2003
Fire Fighting › Combustible Materials
Issued 20 May 2003
Resolved
Repair hydraulic leak from port side hydraulic system isolation valve.
Due 23 May 2003
Resolved 22 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 May 2003
Resolved
Remove abandoned air control throttle selector from both main engines.
Due 23 May 2003
Resolved 29 May 2003
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 May 2003
Resolved
Properly mount junction box for port and starboard engine hotstarts.
Due 23 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 May 2003
Resolved
Properly label un-identified circuit breakers in engine room panelboard located forwrd amidships.
Due 23 May 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 20 May 2003
Resolved
Remove empty 55 gallon drum from engine room or stow properly in area away from machinery.
Due 23 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 May 2003
Resolved
Renew control wire for thruster pump stroking motor on port main engine.
Due 23 May 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 20 May 2003
Resolved
Install exhaust lagging to turbocharger outlet elbow connection on both main engines.
Due 23 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service)
Issued 29 March 2002
Resolved
Relabel circuit box breakers under pilot house. Labels have faded.
Due 29 March 2002
Resolved 29 March 2002
Electrical › Electrical Distribution System (emergency)
Issued 29 March 2002
Resolved
Reconnect wiring conduits along starboard quarter, top deck. LEGACY COMPONENT DESC: Wiring
Due 29 March 2002
Resolved 29 March 2002
Lifesaving › Lifejacket/PFD (General)
Issued 29 March 2002
Resolved
Properly install identification plates on exterior lifejacket lockers and second locker, stbd side main deck. Plates were available for exterior lockers but not installed. Interior locker was missing plate. LEGACY COMPONENT DESC: Storage
Due 29 April 2002
Resolved 18 April 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 29 March 2002
Resolved
Properly install reefer alarm or modify door handle so it cannot lock.
Due 14 April 2002
Resolved 14 April 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2002
Resolved
Properly repair electrical wiring on back on reach-in freezer.
Due 1 April 2002
Resolved 31 March 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2002
Resolved
Properly install marine navigation lights in running lights.
Due 29 April 2002
Resolved 18 April 2002
Lifesaving › Lifebuoys
Issued 29 March 2002
Resolved
Replace stbd lifering on pilothouse.
Due 1 April 2002
Resolved 31 March 2002
Lifesaving › Lifebuoys
Issued 29 March 2002
Resolved
Properly add retroreflective materials to liferings.
Due 7 April 2002
Resolved 7 April 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 29 March 2002
Resolved
Repair/replace retroreflective materials on identified 99 lifejackets (adult) and 9 child lifejackets. Maximum number of persons limited to number of available lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Due 29 April 2002
Resolved 6 June 2002
Lifesaving › Buoyant Apparatus
Issued 29 March 2002
Resolved
Properly install and provide copy of servicing report for missing 100 person IBA. Until IBA properly installed or replacement lifesaving apparatus installed, no more than a maximum of 352 passengers may be carried.
Due 29 April 2002
Resolved 18 April 2002
Engineering › Steering Gear System › Rudder
Issued 29 March 2002
Resolved
Repair port steering gear. Submit repair proposal along with results of investigaton on cause of rudder performance when at hard port.
Due 29 April 2002
Resolved 18 April 2002
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 13 March 2002
Resolved
Repair sewage line that broke on 05Mar02 and ensure a satisfactory test is conducted. Test must be done to the satisfaction of the OCMI/attending Inspector.
Action required: 705 - Other - as specified
Resolved 14 March 2002
Resolution: Conducted satisfactory hydro test of new piping (PVC) at approx. 4-5 psi. Piping and support brackets are satisfactory. Vessel has long term plan to replace PVC with metal piping.
Electrical
Issued 6 September 2001
Resolved
Replace trim lights on perihery of deck house
Condition: Unknown
Due 30 March 2002
Resolved 18 April 2002
Deck/Cargo
Issued 6 September 2001
Resolved
Repair fracture in aft starboard spud housing
Condition: Unknown
Due 6 December 2001
Resolved 10 January 2002
Deck/Cargo
Issued 6 September 2001
Resolved
Replace wiring to port forward and aft starboard spud limit switches
Condition: Unknown
Due 6 December 2001
Resolved 10 January 2002
Navigation
Issued 6 September 2001
Resolved
Repair pin and fitting on port side of rudder crossmember
Condition: Unknown
Due 6 December 2001
Resolved 10 January 2002
Fire Fighting
Issued 25 April 2001
Resolved
UPDATE FIRE CONTROL PLAN.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Deck/Cargo
Issued 25 April 2001
Resolved
REPLACE ALL WIRE CABLES FOR FOUR SPUDS.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Lifesaving
Issued 25 April 2001
Resolved
REPLACE DEFECTIVE TAPE ON LIFE JACKETS.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Lifesaving
Issued 25 April 2001
Resolved
PROVIDE A MEANS FOR QUICK RELEASE FOR ACCESS TO STOWAGE OF LIFE JACKETS IAW46 CFR 117.78(a)(4).
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Accommodation/Occupational Safety
Issued 25 April 2001
Resolved
MAKE GALLEY & STORES AVAILABLE FOR SATISFACTORY SANITATION IN SPECTION IAW 46 CFR 115.818
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Navigation
Issued 4 January 2001
Resolved
Repair/Replace upper port pedestal bearing (housing cracked). Inspect/Tighten all pedestal bearing bolts.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Construction/Loadline
Issued 4 January 2001
Resolved
Provide repair proposal for cracks in lower area of port and stbd after spud wells.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Construction/Loadline
Issued 4 January 2001
Resolved
Adjust/Repair Water tight doors at frame #'s 17, 34, and 43 and prove watertight integrity of each I.A.W. 46 CFR 115.802 (a).
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Electrical
Issued 4 January 2001
Resolved
Insulate shore tie splice located in forepeak tank with appropriate material and support cable with metal supports spaced not more than 24" apart I.A.W. 46 CFR 120.340.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Fire Fighting
Issued 1 May 2000
Resolved
PROVIDE SERVICE REPORT FOR FIRE DETECTION SYSTEM, I.A.W. 46 CFR 118.120.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Electrical
Issued 1 May 2000
Resolved
MAKE PROPER REPAIRS TO THE ELECTRICAL CONDUIT TO THE GALLEY GRILL AND CONVRCTION OVEN.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Fire Fighting
Issued 19 May 1998
Resolved
INSTALL A REMOTE PULL BOX FOR FIXED CO2 SYSTEM LOCATED IN GALLEY (OUTSIDE THE SPACE), AND PROVIDE INSTRUCTIONS FOR THE OPERATION OF THE SYSTEM AT THEPULL BOX.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Construction/Loadline
Issued 23 May 1997
Resolved
CONDUCT SATISFACTORY DEADWEIGHT SURVEY ON VESSEL. UNTIL THIS IS COMPLETED, VESSEL IS RESTRICTED TO CARRYING 435 PASSENGERS.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Construction/Loadline
Issued 23 May 1997
Resolved
PROVIDE RUBBER GASKETS FOR PORT AND STARBOARD POTABLE WATER TANK VOID ACCESS PLATES (4 ACCESSES).
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Construction/Loadline
Issued 13 May 1997
Resolved
VESSEL MAY OPERATE WITH ONLY 435 PASSENGERS UNTIL A NEW DEADWEIGHT SURVEY IS CONDUCTED AND APPROVED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Deck/Cargo
Issued 15 April 1997
Resolved
PROCURE AND ATTACH ANCHOR LINE.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Lifesaving
Issued 15 April 1997
Resolved
HAVE ALL (6) IBA'S SERVICED AND PROVIDE REPORTS TO OFFICE.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Fire Fighting
Issued 15 April 1997
Resolved
PROCURE AND MOUNT (2) APPROVED 50 FOOT, INCH AND A HALF FIRE HOSES. (NO SAIL)
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Lifesaving
Issued 14 November 1996
Resolved
PROVIDE RETROFLECTIVE TAPE FOR 35 ADULT/1 CHILD PERSONAL FLOTATION DEVICES (PFD'S). VESSEL RESTRICTED TO CARRYING 465 ADULT/54 CHILD PASSENGERS UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Navigation
Issued 14 November 1996
Resolved
MAKE REPAIRS TO LEAKS IN HYDRAULIC CROSS OVER LINES IN ENGINE ROOM.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Fire Fighting
Issued 14 November 1996
Resolved
PROVIDE PLACARD FOR FIRE STATION #2.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Lifesaving
Issued 14 November 1996
Resolved
PROVIDE TWO RING BUOYS FOR WEATHER DECK.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Fire Fighting
Issued 6 September 1996
Resolved
INSTALL APPROVED NOZZLES ON ALL FIRE HOSES STATIONED THROUGHOUT VESSEL.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Navigation
Issued 18 July 1996
Resolved
PROVE PROPER OPERATION OF NEW BOW THRUSTER.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Accommodation/Occupational Safety
Issued 18 July 1996
Resolved
UNCLOG DRAIN LEADING FROM GUTTER UNDER SEWAGE LINE IN PORTSIDE GALLEY.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Electrical
Issued 18 July 1996
Resolved
REMOVE WIRE NUTS FROM WIRING BELOW BRIDGE (THREE ON WIRING ON STBD SIDE DECK AND ONE ON FORWARD JUNCTION BOX) AND PROPERLY DEAD-END OR WIRE CRIMP.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Accommodation/Occupational Safety
Issued 18 July 1996
Resolved
PROVIDE SPECIFICATIONS FOR NEW CARPETING NOW IN PLACE ON TOPSIDE DECK AND FORWARD EXTERIOR PART OF SECOND DECK.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Navigation
Issued 9 May 1996
Resolved
FIX HYDRAULIC LEAK ON PORT, AFT HYDRAULIC PUMP DISCHARGE (SUPPLY LINE TO PADDLES) ABOVE ITEM TO BE COMPLETED NO LATER THAN 30JUN96 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 May 1996
Resolved 9 May 1996
Navigation
Issued 3 April 1996
Resolved
Repair or replace the bow thruster which is leaking hydraulic oil into the lake when operated. Do not operate the bow thruster until this item is cleared by a Coast Guard Marine inspector.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Accommodation/Occupational Safety
Issued 3 April 1996
Resolved
Repair the vacuum flush on the toilet in the port side main deck woman's head.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996
Resolved
Adjust the watertight doors at bulkheads 25 and 33 to ensure proper seal ofdoor gasket and tightness of all securing dogs.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Electrical
Issued 3 April 1996
Resolved
Make proper electrical wiring connections with proper wire type, supports, receptical boxes and circuit protection and permanently mount and support the added water treatment system components.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Fire Fighting
Issued 2 February 1996
Resolved
Remove the carpet from under the fire doors from the galley to main deck and in the stair from the main deck leading to the second deck and install metal thresholds.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Deck/Cargo
Issued 23 December 1995
Resolved
Make proper wire rope connections to the standing rigging supporting the bow gangway at the smoke stacks, ensuring that the wire rope clamps have the saddles on the tension side of the splice.
Condition: Unknown
Due 23 December 1995
Resolved 2 January 1996
Fire Fighting
Issued 23 December 1995
Resolved
INSTALL A FIRE SCREEN DOOR AT THE EXIT TO THE GALLEY ON THE STBD SIDE WHICHHAS AN A-15 FIRE RATING. THE LARGE GLASS WINDOW IN THE EXISTING DOOR IS NOT A-15 FIRE RATED.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
Remove insulation in overhead of galley in way of both toilets of the port and starboard main deck toilet rooms. Repair the holes in the overhead by welding or installation of gasketed steel bolts which secure the toilets inplace.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Lifesaving
Issued 23 December 1995
Resolved
PROPERLY MOUNT SPUD LIMIT SWITCHES TO ENSURE THEY ARE SECURELY HELD IN PLACE AND DEMONSTRATE SATISFACTORY OPERATION.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Engineering
Issued 23 December 1995
Resolved
Replace missing insulation on the turbo chargers on the main generator and the port and starboard main engines.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Electrical
Issued 23 December 1995
Resolved
MAKE REPAIRS TO ELECTRICAL WIRING FOR PILOT HOUSE CONTROL CONSOLE BY REPLACING WIRES WHICH HAVE MULTIPLE SPLICES WITH SINGLE PIECES OF WIRE.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Electrical
Issued 23 December 1995
Resolved
REPLACE THE OIL LINE BETWEEN OIL FILTER AND OIL COOLER OF MAIN GENERATOR PRIME MOVER.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Lifesaving
Issued 23 December 1995
Resolved
Install a proper weak link on the port outboard inflatable buoyant apparatus. Have all inflatable buoyant apparatus hydrostatic releases tested or remove them from the vessel and stow the inflatalbe buoyant apparatus in a float free arrangement.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Electrical
Issued 23 December 1995
Resolved
Properly wire and support the wiring for the fire detection system in accordance with 46 C.F.R. Part 183 or remove the system and associated wiring. The system must remain disconnected from the power source until this item is corrected.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Electrical
Issued 23 December 1995
Resolved
Properly wire the vessel security alarm system in accordance with 46 C.F.R.Part 183 or remove system and associated wiring from the vessel. The system must remain disconnected from its power source until this is corrected.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF THE VESSEL'S POTABLE FRESH WATER SYSTEM. PROVIDE A COPY OF AN INSPECTION REPORT FROM THE COUNTY HEALTHDEPARTMENT ACCEPTING THE INSTALLATION PRIOR TO USING THE FRESH WATER FOR COOKING OR DRINKING.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Construction/Loadline
Issued 23 December 1995
Resolved
INSTALL MISSING CHECK VALVES IN BILGE SUCTION LINES IN NUMBER 10 PORTSIDE VOID AND FORWARD GALLEY.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Electrical
Issued 23 December 1995
Resolved
Install an indicator light system for each watertight door which warns whenthe door is open. This system must be installed on the bridge as required by 46 C.F.R. Section 170.255(e). Wiring must be in accordance with 46 C.F.R. Part 183.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Electrical
Issued 23 December 1995
Resolved
DETACH THE WIRING SUPPORTED FROM THE HYDRAULIC PIPING UNDER THE PILOT HOUSEAND PROPERLY SUPPORT SAME.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Engineering
Issued 23 December 1995
Resolved
REPLACE THE BELT GUARD FOR STARBOARD ENGINE-RUN FIRE PUMP WHICH IS MISSING.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Construction/Loadline
Issued 23 December 1995
Resolved
Conduct none destructive testing of welds for port side sewage tank pump out and vent fittings where they penetrate the side of the hull. (dye penetrant testing is acceptable)
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Electrical
Issued 23 December 1995
Resolved
Replace the temporary motor controller cover on the forward refrigeration compressor motor with a proper cover which fits the unit.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
Properly pitch the main sewage line on the port side of the galley overheadto flow forward in all conditions of trim. Repair break in line and clean sewage out of tray under sewage lines ensuring trays drain freely to bilge.
Condition: Unknown
Due 23 December 1995
Resolved 2 January 1996
Navigation
Issued 23 December 1995
Resolved
INSTALL PROPER HIGH STRENGTH BOLTS IN RUDDER BEARING ATTACHMENTS, INSTALL SPACERS ON PORT AND STARBOARD RUDDER PILLOW BLOCKS. CONDUCT SEA TRIALS TO DETERMINE IS RUDDER REPAIRS ARE SATISFACTORY.
Condition: Unknown
Due 23 December 1995
Resolved 2 January 1996
Engineering
Issued 23 December 1995
Resolved
REMOVE PLASTIC HOSE FUEL SIGHT GLASS AND PET COCK FITTINGS ON FUEL TANK ANDINSTALL PROPER AUTOMATIC CLOSING VALVES AND GLASS SIGHT GLASS WITH PROPER PROTECTIVE CAGE.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Engineering
Issued 23 December 1995
Resolved
CONDUCT SEA TRIALS TO ENSURE PORT AND STARBOARD PADDLE WHEEL DRIVES FUNCTION PROPERLY WITHOUT HYDRAULIC OIL LEAKAGE AFTER REPAIR OF DRIVE SEALS.
Condition: Unknown
Due 23 December 1995
Resolved 2 January 1996
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF ALL TOILETS AFTER COMPLETION OF REPAIRS TO TOILETS AND SEWAGE PIPING. ENSURE THAT ALL TOILETS ARE PROPERLYSECURED IN PLACE.
Condition: Unknown
Due 23 December 1995
Resolved 2 January 1996
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
REPLACE THE TWO MISSING VENTILATION LOUVERS ON EXTERIOR OF VESSEL.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Fire Fighting
Issued 23 December 1995
Resolved
INSTALL APPROVED A-15 INSULATION IN THE OVERHEAD OF THE ENTIRE ENGINE ROOM.REPLACE ANY EXISTING INSULATION WHICH IS OIL SOAKED OR NOT SECURED TO THE OVERHEAD.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Electrical
Issued 23 December 1995
Resolved
REPLACE THE WIRE IN THE ENGINE ROOM ON THE PORT SIDE ABOVE THE BATTERY BOXES WHICH WAS BURNED DURING WELDING ON THE EXTERIOR OF THE HULL.
Condition: Unknown
Due 31 January 1996
Resolved 9 January 1996
Navigation
Issued 23 December 1995
Resolved
Replace missing cotter pin on top of port rudder post which was loose.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
REPLACE VENT FAN ON SECOND DECK AFT PORT SIDE OF ACCOMMODATIONS SPACE OR PROPERLY DEAD END AND TAG OUT POWER SUPPLY.
Condition: Unknown
Due 31 January 1996
Resolved 9 January 1996
Construction/Loadline
Issued 23 December 1995
Resolved
Conduct non destructive testing of welding for construction access insert in port longitudinal bulkhead above the new port side sewage tank. (dye penetrant testing is acceptable)
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Electrical
Issued 23 December 1995
Resolved
Properly wire and support wiring for bilge alarm system in accordance with 46 C.F.R. Part 183 or remove system and associated wiring. Bilge alarm system must remain disconnected from the electrical supply until this is corrected.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Engineering
Issued 23 December 1995
Resolved
DEMONSTRATE THE PROPER OPERATION OF ALL MACHINERY AND PUMPS IN THE ENGINE ROOM.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Fire Fighting
Issued 23 December 1995
Resolved
MAKE REPAIRS TO FIRE SCREEN DOOR THRESHOLD ON STARBOARD SIDE ON SECOND DECKTO ELIMINATE EXCESSIVE GAP AT BOTTOM OF DOOR.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
COMPLETE INSTALLATION OF NEW SEWAGE TANKS INCLUDING FILL, VENT AND DISCHARGE PIPING. CONDUCT 5 PSI AIR TEST IN THE PRESENCE OF A COAST GUARD INSPECTOR, COMPLETE CONNECTION OF TOILETS TO NEW SEWAGE TANKS AND DEMONSTRATE OPERATION OF SAME.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Construction/Loadline
Issued 23 December 1995
Resolved
INSTALL CAPS OR PLUGS ON OPEN VALVES IN PIPING ON PORT FORWARD SIDE OF ENGINE ROOM. DEMONSTRATE OPERATION OF THIS PIPING SYSTEM.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Deck/Cargo
Issued 23 December 1995
Resolved
REPAIR THE STARBOARD AFT SPUD WINCH WHICH IS NOT OPERATING.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
LABEL THE EMERGENCY ESCAPE HATCH COVER IN THE MAIN DECK EXIT FROM THE AFT LAZERETTE "EMERGENCY ESCAPE DO NOT BLOCK".
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 23 December 1995
Resolved
Make proper wiring and plumbing connections and repairs to the outside bar area on the upper deck. This bar must remain out of service until the repairs are completed.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Construction/Loadline
Issued 7 November 1995
Resolved
REMOVE SILICONE FILLING AND WELD SEAMS WHERE COAMING MEETS DECK ABOVE STAIRWELLS ON PORT & STARBOARD SIDE GOING TO AND FROM WEATHER DECK.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Engineering
Issued 7 November 1995
Resolved
PROVE OPERATION OF WATER TEMPERATURE/OIL TEMPERATURE GAUGES TO BOTH PORT & STARBOARD MAIN ENGINES.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 7 November 1995
Resolved
PROVIDE BATTERY BOX COVERS, REMOVE BATTERY CHARGERS, AND REMOVE ALL DEAD END WIRING IN WAY OF 3RD DECK (WEATHER DECK), AFT.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 7 November 1995
Resolved
PROVIDE LIGHT COVER FOR FIXTURE IN STORAGE CLOSET LOCATED ON MAIN DECK, STARBOARD SIDE, AFT.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 7 November 1995
Resolved
PROPERLY WIRE HIGH BILGE ALARM WIRING IN AFT COMPARTMENT.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Engineering
Issued 7 November 1995
Resolved
PROVIDE LAGGING FOR EXHAUST LINE TO STARBOARD ENGINE.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 7 November 1995
Resolved
PROPERLY SECURE ALL DEAD WIRING AT FRAME 25 STORAGE AREA, STARBOARD SIDE.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 7 November 1995
Resolved
PROVIDE LIGHT COVER FOR FIXTURE AT FRAMES 21 & 22 (ICEROOM).
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 7 November 1995
Resolved
PROPERLY ATTACH WIRE TO ALTERNATOR TERMINAL ON PORT ENGINE.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 7 November 1995
Resolved
PROPERLY SECURE ELECTRICAL SHORE TIE IN ORDER TO PREVENT CHAFING AGAINST STUFFING TUBE IN FOREPEAK ON STARBOARD SIDE.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Construction/Loadline
Issued 7 November 1995
Resolved
RE-WELD CRACK IN OVERHEAD LONGITUDNAL ALONG CENTERLINE IN FORWARD PART OF GALLEY (FRAME AFT OF WATERTIGHT DOOR).
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Engineering
Issued 7 November 1995
Resolved
PROVIDE MACHINERY GUARDS FOR STARBOARD ENGINE.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 26 September 1995
Resolved
Remove unauthorized temporary wiring throughout galley and engine room. Properly install covers on all junction boxes.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995
Resolved
Provide in water welding repair proposal for repairs to bottom plating and associated framing in way of frames 7 & 8.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Do not use the galley for food preparation until it is completely cleaned and excessive grease removed from appliances and vent ducts. Reinstall deckplates and demonstrate operation of sink sump pumps.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Construction/Loadline
Issued 26 September 1995
Resolved
Make comprehensive proposal for conducting an underwater survey in lieu of drydocking to include: Cleaning of hull, video of hull, reference marking of hull, two way communications with diver, internal inspection of entire hull structure, and opening and inspection of sea valves.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Properly install sewage tanks and piping in accordance with approved plans and cover letter of August 27, 1993. In doing so ensure that sewage pipingdrains down hill to the sewage tanks in all conditions of trim and list.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Reattach mounting bracket for #2 fresh water filter. Demonstrate that all filters are leak free and function properly.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Demonstrate proper operation of the ultra violet fresh water treatment system in accordance with manufacturers instructions. Demonstrate operationof shut off valve when ultra violet lights are not operating.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995
Resolved
Remove portable battery chargers from battery banks and demonstrate that the installed battery charging systems are functioning properly and can maintain the batteries in a charged condition.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Remove the unused PVC sewage pipe on the aft starboard side of the galley. Cap the bulkhead penetration and stop valve.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Replace multiple short pieces of pipe and hose clamps in galley sink drainsand demonstrate operation. Provide for clean out ports to facilitate removing clogs in lines.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995
Resolved
Install pipe plug on unused overboard discharge at frame 9 starboard side.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Electrical
Issued 26 September 1995
Resolved
Properly install lighting fixtures in galley and engineroom with the required UL approved covers, supported by approved mounts.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Remove plastic bag from garbage disposal reinstall proper drip proof housing, repair piping as needed and controller switch cover which is held together with duct tape.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995
Resolved
Remove all dead end and non marine wiring in engine room. Submit updated electrical plans for new electrical wiring systems prior to installation ofany new systems. Provide copy of approved wiring plans for system review bythe marine inspector.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Remove temporary fan taped up in galley.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Make permanent repairs to the fresh water galley sink supply line over the sink with the disposal where a temporary patch was placed on the hot water line.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995
Resolved
Reweld the stuffing tube for the Hydraulic lines on the aft bulkhead of thefor peak where patched.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995
Resolved
Reattach captive chain to fore peak deck hatch cover.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995
Resolved
Remove unauthorized and unused batteries from engine room and engine room trunk.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995
Resolved
Properly support all wiring in the engine room and access trunk to engine room. Wiring must be in runs along bulkheads and overheads attached with acceptable insulated metal wire hangers. Wiring should not be haphazardously attached to other piping systems with plastic wire ties.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995
Resolved
Place all batteries in proper battery boxes with either lead or fiberglass linings.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Properly support A/C cooling water and condensate piping in overhead of engine room.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995
Resolved
Install limber holes in the bottom framing in the galley area to allow for free drainage of the bilges and effective cleaning of the galley bilge.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995
Resolved
Replace bilge strainer in aft peak compartment.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Engineering
Issued 26 September 1995
Resolved
Ensure all hoses for the cooling water systems are double clamped.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Accommodation/Occupational Safety
Issued 26 September 1995
Resolved
Replace missing vent cleaning access cover in galley exhaust vent duct withmetal closure.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Lifesaving
Issued 20 June 1995
Resolved
AS PART OF DRYDOCK EXTENSION GRANTED THROUGH 30NOV95, PROVIDE INFLATABLE BUOYANT APPARATUS'.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Lifesaving
Issued 5 April 1995
Resolved
PROVIDE INFLATABLE BUOYANT APPARATUS' FOR VESSEL.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Lifesaving
Issued 5 April 1995
Resolved
REPLACE BROKEN WATER LIGHT ON LIFEFLOAT
Condition: Unknown
Due 15 May 1995
Resolved 5 May 1995
Electrical
Issued 5 April 1995
Resolved
REMOVE OR PROPERLY DEAD-END WIRING IN FIDLEY AND ENGINE ROOM
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 5 April 1995
Resolved
REMOVE EXCESSIVE GREASE FROM EXHAUST HOOD ABOVE GRILLS AND CONDUCT GENERAL HOUSE KEEPING OF GALLEY
Condition: Unknown
Due 15 May 1995
Resolved 5 May 1995
Electrical
Issued 5 April 1995
Resolved
FABRICATE AND INSTALL COVERS FOR BATTERIES IN FIDLEY
Condition: Unknown
Due 15 May 1995
Resolved 5 May 1995
Electrical
Issued 5 April 1995
Resolved
PERMANENTLY MOUNT BATTERY CHARGER IN FIDLEY AREA
Condition: Unknown
Due 15 May 1995
Resolved 5 May 1995
Construction/Loadline
Issued 5 April 1995
Resolved
REPLACE BILGE ALARM SENSOR IN ZONE 2
Condition: Unknown
Due 15 May 1995
Resolved 5 May 1995
Lifesaving
Issued 5 April 1995
Resolved
INSTALL SPACERS BETWEEN LIFEFLOATS
Condition: Unknown
Due 15 May 1995
Resolved 5 May 1995
Electrical
Issued 19 October 1994
Resolved
PROVIDE BATTERY CAGES OR COVERS FOR BATTERY BANKS, PORT & STBD IN ENGINE ROOM IAW 46 CFR 183.05-20.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Electrical
Issued 19 October 1994
Resolved
PROVIDE PROPER COVERS FOR ALL LIGHTING FIXTURES THROUIGH OUT VESSEL, NOTABLE LOCATIONS-MEN'S HEAD MAIN DECK, LIQUOR LOCKER, DRY STORES PASSAGEWAY, ENTIRE GALLEY, BOTH LADDER PASSAGEWAYS LEADING DOWN INTO GALLEY, ETC.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Fire Fighting
Issued 14 October 1994
Resolved
COMPLETE SERVICING/RENEWAL (I.E., STOP LEAK, PROVIDE MIN. 60 PSI W/2 EFFECTIVE STREAMS). OF ELEC. FIRE PUMP.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Electrical
Issued 30 September 1994
Resolved
1.prove proper operation of main generator.
Condition: Unknown
Due 30 September 1994
Resolved 30 September 1994
Electrical
Issued 30 September 1994
Resolved
provide cg 2692 for item #1
Condition: Unknown
Due 30 September 1994
Resolved 30 September 1994
Electrical
Issued 25 August 1994
Resolved
MAKE PROPER REPAIRS TO STARBOARD GENERATOR FUEL PUMP.
Condition: Unknown
Due 25 September 1994
Resolved 3 September 1994
Electrical
Issued 25 August 1994
Resolved
MAKE PROPER REPAIRS TO SHORE CONNECTION IN WAY OF GANGWAY AND FOREPEAK SPLICE (JUNCTION BOX).
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Fire Fighting
Issued 25 August 1994
Resolved
PROVIDE MATERIAL SPECIFICATIONS FOR FIRE RATED INSULATION INSTALLED ABOVE THE OVERHEAD LIFE PRESERVER STOWAGE.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Construction/Loadline
Issued 25 August 1994
Resolved
RE-MARK STARBOARD MID-BODY DRAFT MARK.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Engineering
Issued 25 August 1994
Resolved
PROVIDE SYNOPSIS OF PERMANENT REPAIRS MADE TO STARBOARD PADDLE WHEEL.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Engineering
Issued 25 August 1994
Resolved
MAKE PERMINANT REPAIRS TO STDB PADDLE WHEEL VSL IS RESTRICTED TO 350 PASSENGERS UNTIL REPAIRS COMPLETED.PRIOR TO GETTING UNDERWAY ONCE REPAIRS ARE COMPLETED OPERATOR IS REQUIRED TO SUBMIT A STATEMENT OF SATISFACTORY UNDERWAY TEST TO MSO SAN FRANCISCO.
Condition: Unknown
Due 25 September 1994
Resolved 30 August 1994
Engineering
Issued 15 July 1994
Resolved
MAKE PERMANENT REPAIRS TO BOW THRUSTER HYDRAULIC LEAK. BOW THRUSTER IS NOT TO BE USED UNTIL THIS REPAIR IS MADE. IN ADDITION TO MAKING BOW THRUSTER INOPERATIVE (DISCONNECTING ELECTRICAL POWER), ALL HYDRAULIC FLUID FROM RESERVOIR MUST BE DRAINED TO PREVENT FUTHER LEAKAGE.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 10 June 1994
Resolved
CLEAN/REMOVE HYDRAULIC OIL (ABOUT 1/2" DEEP), LOCATED BETWEEN FRAMES 6 AND 7, 6" STARBOARD SIDE.
Condition: Unknown
Due 30 June 1994
Resolved 6 July 1994
Engineering
Issued 10 June 1994
Resolved
MAKE REPAIRS TO BOW THRUSTER HYDRAULIC LEAK.
Condition: Unknown
Due 30 June 1994
Resolved 18 July 1994
Construction/Loadline
Issued 10 June 1994
Resolved
PROVIDE BILGE SUCTION STRAINER FOR PIPE LOCATED BETWEEN FRAMES 6 AND 7, 2" STARBOARD OF KEEL.
Condition: Unknown
Due 30 June 1994
Resolved 18 July 1994
Construction/Loadline
Issued 5 April 1994
Resolved
PROVIDE CAPS FOR PIPE ENDS FOR THROUGH-HULL VALVES FOR A/C COOLING PUMP NO LONGER IN USE LOCATED BETWEEN FR 39 AND 40 ON STBD SIDE.
Condition: Unknown
Due 12 April 1994
Resolved 6 June 1994
Fire Fighting
Issued 5 April 1994
Resolved
MOUNT HEAT DECTECTOR IN ENGINE ROOM.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Electrical
Issued 5 April 1994
Resolved
PROPERLY SPLICE WIRES TO ALL BILGE LEVEL ALARMS IN WAY OF WIRE MOUNTS.
Condition: Unknown
Due 12 April 1994
Resolved 6 June 1994
Accommodation/Occupational Safety
Issued 5 April 1994
Resolved
REPLACE ALL FIRE-RATED INSULATION (USED WITHIN THE PFD STOWAGE AREAS) BELOWDECKS.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Construction/Loadline
Issued 5 April 1994
Resolved
PROVIDE MOUNTS FOR SUCTION AND DISCHARGE LINES TO EMERGENCY FIRE/BILGE PUMPS.
Condition: Unknown
Due 12 April 1994
Resolved 6 June 1994
Construction/Loadline
Issued 5 April 1994
Resolved
LABEL EACH INDIVIDUAL BILGE SUCTION AND DISCHARGE LINE AT MANIFOLD IN ENGINE ROOM.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Engineering
Issued 5 April 1994
Resolved
REPAIR FUEL LEAK #2 RETURN LINE ON AUXILIARY GENERATOR ENGINE.
Condition: Unknown
Due 12 April 1994
Resolved 6 June 1994
Electrical
Issued 5 April 1994
Resolved
PROPERLY SPLICE AND MOUNT CABLE TO PORT HYDRAULIC COOLING (WATER) PUMP.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Electrical
Issued 5 April 1994
Resolved
REMOUNT JUNCTION BOX AND LIGHT FIXTURE OVER SINK IN GALLEY.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Electrical
Issued 5 April 1994
Resolved
TAG OR REMOVE DEAD-END CABLE IN PORT STORAGE/FAN ROOM.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Electrical
Issued 5 April 1994
Resolved
REMOUNT LIGHT IN PORT STORAGE/FAN ROOM.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Documentation
Issued 5 April 1994
Resolved
PROVIDE DOCUMENTATION CERTIFYING ADEQUACY (ESPECIALLY REGARDING STABILITY) OF NEWLY CONVERTED SEWAGE TANKS.
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Electrical
Issued 5 April 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF LOW L/O ALARM/CUTOUT TO MAIN GENERATORENGINE.
Condition: Unknown
Due 12 April 1994
Resolved 6 June 1994
Accommodation/Occupational Safety
Issued 5 April 1994
Resolved
PROVIDE ADEQUATE HANGER FOR HYDRAULIC CROSS-OVER LINE AND MAKE INSTALLATIONPERMANENT.
Condition: Unknown
Due 5 May 1994
Resolved 6 June 1994
Navigation
Issued 19 November 1993
Resolved
REINSTALL BOTH DEPTH GAUGES AND PROVIDE A COPY OF THE SERVICING REPORT FOR BOTH.
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Construction/Loadline
Issued 25 May 1993
Resolved
MAKE PERMINANT REPAIR TO HOLE ON MAIN DECK PORT SIDE 1/2" HOLE 7' ABOVE DECK BY FORWARD STAIR CASE.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Construction/Loadline
Issued 25 May 1993
Resolved
MAKE PERMINANT REPAIR TO WATERTIGHT DOOR AT FRAME 7, HOLE IN LIP (KNIFE EDGE)
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Navigation
Issued 30 April 1993
Resolved
REPAIR AS ORIGINAL, STARBOARD HYDRAULIC PIPE TO STERN WHEEL, INWAY OF AFT BULKHEAD THRU HULL PENETRATION.
Condition: Unknown
Due 11 July 1993
Resolved 11 July 1993
Navigation
Issued 30 April 1993
Resolved
REPAIR PROPERLY, POORLY WELDED AND CLIPPED SUPPORT BRACKET FOR STARBOARD STEERING RAM.
Condition: Unknown
Due 30 June 1993
Resolved 6 July 1993
Navigation
Issued 30 April 1993
Resolved
REPAIR FRACTURES IN BOTH PORT AND STARBOARD CORNERS OF AFT PADDLE WHEEL WRAP AROUND SUPPORT.
Condition: Unknown
Due 11 July 1993
Resolved 11 July 1993
Construction/Loadline
Issued 30 April 1993
Resolved
MAKE PROPER BULKHEAD PENETRATIONS IN WAY OF PIPE PENETRATIONS ENG. RM./FUELRM. BULKHEAD.
Condition: Unknown
Due 11 July 1993
Resolved 11 July 1993
Lifesaving
Issued 30 April 1993
Resolved
REPAIRAS ORIGINAL BOW GANGWAY SWIVEL CONNECTION, PROIR TO PASSENGER USE.
Condition: Unknown
Due 30 June 1993
Resolved 6 July 1993
Accommodation/Occupational Safety
Issued 6 April 1993
Resolved
RE-INSTALL PROPER DOOR LATCHES IN MAIN DECK FIRE DOORS. WAIT STAFF MUST NOTTAPE OR MAKE LATCHES INOP IN ANY WAY.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Fire Fighting
Issued 6 April 1993
Resolved
REPLACE THREE 1 1/2" FIRE HOSES WITH ONES THAT MEET THE REQUIREMENTS OF 46 CFR 181,15-10(d)(1)
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Fire Fighting
Issued 6 April 1993
Resolved
PROVIDE TWO ADDITIONAL SPANNER WRENCHES.
Condition: Unknown
Due 14 May 1993
Resolved 21 May 1993
Fire Fighting
Issued 6 April 1993
Resolved
MARK AND NUMBER FIRE STATIONS.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Construction/Loadline
Issued 6 April 1993
Resolved
STENCIL WATERTIGHT DOORS, BOTH SIDES" KEEP CLOSED WHILE UNDERWAY EXCEPT FORTRANSIT."
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Electrical
Issued 6 April 1993
Resolved
REPAIR AND ENCLOSE WIRE RUN TO BAR, UPPER DECK AFT OF LIFEFLOATS.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Electrical
Issued 6 April 1993
Resolved
REPAIR AFT DECK LIGHTS FIXTURES, LOACTED OVER PADDLE WHEELS.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Electrical
Issued 6 April 1993
Resolved
COMPLETE PERMANENT REPAIR TO ELECTRICAL SYSTEM FOR AFT SPUD MOTORS.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Electrical
Issued 6 April 1993
Resolved
REPAIR ELECTRIC LIGHT FIXTURE, PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Lifesaving
Issued 6 April 1993
Resolved
PROVIDE 2 ADDITIONAL CHILD LIFE JACKETS.PERSONS ALLOWED REDUCED TO 530 UNTILL THIS ITEM COMPLETED.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Accommodation/Occupational Safety
Issued 6 April 1993
Resolved
REPAIR FRACTURED WINDOW, PORT SIDE MAIN DECK.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Construction/Loadline
Issued 25 August 1992
Resolved
MAKE PERMANENT REPAIRS TO BOTTOM PLATE, AS ORIGINAL, INWAY OF BOTTOM SHELL AT AFT BULKHEAD AND GLASS BOTTOM AREA OF VSL. COMPLETE AT NEXT DRYDOCK ANDPRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 25 August 1992
Resolved 25 August 1992
Construction/Loadline
Issued 25 August 1992
Resolved
COMPLETE THE APPROVED TEMP REPAIRS TO HOLES INWAY OF AFT BULKHEAD, BOTTOM SHELL AREA.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Construction/Loadline
Issued 25 August 1992
Resolved
COMPLETE APPROVED TEMP REPAIRS TO GLASS BOTTOM AREA OF VSL.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Accommodation/Occupational Safety
Issued 6 April 1992
Resolved
REMOVE PAINT FROM E/R WATERTIGHT DOOR GASKET.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Engineering
Issued 6 April 1992
Resolved
REPLACE REMOTE FUEL SHUT-OFF WITH STRONGER CONNECTION TO REMOTE CABLE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Lifesaving
Issued 6 April 1992
Resolved
REPLACE WATERLIGHT FOR LIFEFLOAT. ITEM SEALED AND OPERATIONAL, BUT CRACKED.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Lifesaving
Issued 6 April 1992
Resolved
RE-LABEL LIFEJACKET STOWAGE TO MATCH PASSENGER DISTRIBUTION: TOP DECK 100 ADULT, 10 CHILD; MID DECK 200 ADULT, 20 CHILD; MAIN DECK REMAINING JACKETS.LABEL SEPARATE STOWAGE FOR CHILD LIFE JACKETS ON TOP DECK.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Navigation
Issued 6 April 1992
Resolved
WELD BULKHEAD PENETRATIONS FOR BOW THRUSTER HYDRAULIC LINES.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Construction/Loadline
Issued 19 January 1992
Resolved
SUBMIT REPAIR PROPOSAL FOR REPAIR OF BORKEN SPUD, AND CRACK IN SPUD SHEATH TO MARINE INSPECTION OFFICE SAN FRANCISCO, CA
Condition: Unknown
Due 19 January 1992
Resolved 19 January 1992
Construction/Loadline
Issued 19 January 1992
Resolved
MAKE PERMANENT REPAIRS TO AFT PORT SPUD AND SPUD SHEATH, ALSO REPAIR CRACKED WELD IN FRAME JUST AFT OF PORT SPUD.
Condition: Unknown
Due 19 January 1992
Resolved 19 January 1992
Electrical
Issued 8 April 1991
Resolved
REMOVE OR PROPERLY TERMINATE EXTRANEOUS WIRING IN AREA UNDER PILOT HOUSE AND IN ENGINE ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Construction/Loadline
Issued 8 April 1991
Resolved
REPLACE BOLTS FOR MANHOLE COVERS. STBD REEFER ROOM, PORT AREA AROUND FUEL TANK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Construction/Loadline
Issued 8 April 1991
Resolved
REPAINT MAXIMUM DRAFT LINES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Documentation
Issued 8 April 1991
Resolved
PROPERLY MOUNT MODIFIED VERSION OF MARPOL V PLACARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Electrical
Issued 8 April 1991
Resolved
PROPERLY BOX AND SECURE BATTERIES IN AREA UNDER PILOT HOUSE AND FOR SPUDS._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Navigation
Issued 8 April 1991
Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Engineering
Issued 8 April 1991
Resolved
INSTALL GUARD FOR SHAFT AREA OF BOW THRUSTER PORT SIDE E/R._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Electrical
Issued 8 April 1991
Resolved
PROVE PROPER OPERATION OF ALARM LIGHT FOR GENERATOR OVERSPEED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Accommodation/Occupational Safety
Issued 8 April 1991
Resolved
SECURE COOKING DEVICES MAIN AND 01 DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Electrical
Issued 8 April 1991
Resolved
REPLACE COVERS JUNCTION BOXES SPECIFICALLY IN AREAS UNDER PILOT HOUSE AND ELECTRONICS ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Electrical
Issued 10 April 1990
Resolved
1 REPAIR/REPLACE STARBOARD VOLT METER ON BRIDGE.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Fire Fighting
Issued 10 April 1990
Resolved
2 REPAIR AND TEST FIRE ALARM PANNEL.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990
Resolved
5 REPLACE ALARM LIGHTS ON MAIN GERERATOR PANNEL IN E.R.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990
Resolved
3 REPAIR AND TEST BILGE ALARM PANNEL.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Navigation
Issued 10 April 1990
Resolved
4 PROVIDE COMPASS DEVIATION CHART.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Construction/Loadline
Issued 20 April 1988
Resolved
1 CLEAN AND PROVIDE ULTRASONIC GAUGINGS OF BOTH HOLDING TANKS. APPROXIMATELY 10 READINGS PER TANK.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Engineering
Issued 20 April 1988
Resolved
2 PERFORM A HYDRO TEST ON AIR RECEIVER AND PROVIDE DOCUMENTATION.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Construction/Loadline
Issued 20 April 1988
Resolved
3 SEAL PERMANENTLY THE HYDRAULIC LINES PENETRATION THE COLLISION BULKHEAD.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Documentation
Issued 20 April 1988
Resolved
6 PROVIDE FCC STATION LICENSE.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Construction/Loadline
Issued 9 August 1987
Resolved
REWELD AROUND THROUGH HULL PIPE FITTINGS BOTH PORT AND STBD COMPARTMENT JUST AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Lifesaving
Issued 9 August 1987
Resolved
PROPERLY LABEL LOCATION OF EMERGENCY ESCAPE HATCH ON GALLEY REAR BULKHEAD OR WATERTIGHT DOOR.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Lifesaving
Issued 9 August 1987
Resolved
REPLACE NET BASKET AS NEEDED ON ONE LIFE FLOAT
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Construction/Loadline
Issued 9 August 1987
Resolved
INSTALLL NEW EMERGENCY ESCAPE HATCH SO AS TO BE ABLE TO OPEN FROM BELOW DECK GALLY STOREROOM.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Lifesaving
Issued 9 August 1987
Resolved
REPLACE ROPE PENDANTS AS NEEDED ON LIFE FLOAT
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Construction/Loadline
Issued 9 August 1987
Resolved
INSTALL LADDER SO AS TO ACCESS EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Lifesaving
Issued 9 August 1987
Resolved
REPLACE AND PROPERLY STENCIL 9 OARS FOR LIFE FLOATS.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Construction/Loadline
Issued 9 August 1987
Resolved
PROVIDE KEEPER CHAINS ON TWO HATCH COVERS MAIN DECK FORWARD.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Engineering
Issued 9 August 1987
Resolved
INSTALL 30X30 WIRE MESH FLAME SCREENS ON ALL FUEL TANKS VENTS.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Electrical
Issued 8 August 1986
Resolved
REPAIR AUTOMATIC TRIP SHUT DOUN CIRCUIT ON AUX GENERATOR AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Construction/Loadline
Issued 8 August 1986
Resolved
MAKE CABLE RUN THROUGH EACH WATERTIGHT BULKHEAD WATERTIGHT
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Electrical
Issued 8 August 1986
Resolved
REPAIR AUTOMATIC TRIP SHUT DOWN CITCUIT AND AVERSPEED MAIN GENERATOR. TESTAND PROVE OPERATION ALL TRIPS AND OVERSPEED.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 17 August 1984
Resolved
REMOVE ALL SHARP PROTRUSIONS IN OVERHEAD LIFE PRESERVER STOWAGE AREAS.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Fire Fighting
Issued 17 August 1984
Resolved
PROVIDE PLANS FOR INSTALLATION OF HALON FIRE EXTINGUISHING SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Fire Fighting
Issued 17 August 1984
Resolved
PROVIDE PLANS TO RELOCATE FIRE STATIONS 2,3, AND 4.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984