Records from 2015 to 2026. Most recent: inspection, 13 May 2026.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 May 2026
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: external inspection of fuel tanks. Fuel tank in bow thruster void showing heavy corrosion on the bottom. Provide plan to OCMI for determining condition of the tank.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 20 July 2026
Resolution: Accepted UT report and external coating of tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2026
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: inspection of all machinery essential to the routine operation of the vessel. Air receiver in aux machinery space(void 3) has 90 psi MAWP and pressure gauge indicated it was holding 100 psi. Pressure relief valve(prv) setting was unreadable. Provide verification a proper PRV is installed.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 4 August 2026
Resolution: PRV replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026
Resolved
Portable fire extinguishers must be located so they are clearly visible and readily acceissible from the space being protected. The installation and location must be to the satisfcation of the [name withheld] fire extinguisher on the 3rd weatherdeck had bracket held together by electrical tape and center mounted portable bracket in engine room is loose and not effective. Repair or replace brackets.
46 CFR 181.530
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 28 July 2026
Resolution: Accepted photo of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards. Dead end wires found beneath center portion of helm console, in void space beneath wheelhouse on starboard side near battery.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 11 June 2026
Resolution: Accepted photo of capped wires.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2026
Resolved
Connections must be made to battery terminals with permanent type connectors. Battery beneath wheelhouse had wingnuts.
46 CFR 183.350
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 11 June 2026
Resolution: Accepted photo of replaced wingnuts.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 May 2026
Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Plastic trash cans found on 3rd deck bar and main deck near galley.
46 CFR 177.405
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 28 July 2026
Resolution: Accepted photo of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026
Resolved
At each initial and subsequent inspection for certification, managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment including the following: inspection of each lifejacket, work vest, and marine buoyant device. Third deck life ring buoy line is fraying and requires replacement.
46 CFR 176.808
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 24 June 2026
Resolution: Accepted photo of replacement.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 May 2026
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following:
Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. In blackwater void #2, starboard transverse frame located 2 frames forward of aft bulkhead there is hole at the top of the transverse frame near the deck connection. Opposing side of hole is inaccessible as it extends over the water. Determine extent of damage on opposing side and provide a repair proposal.
46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 4 August 2026
Resolution: Repairs not required based on reinspection.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 February 2026
Resolved
Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (passenger vessels) of this chapter:
"A door in a bulkhead required to be A-0 Class must be of solid or hollow steel or equivalent material construction, and capable of meeting the requirements of an A-0 Class bulkhead."
Two (02) replacement doors installed in the A-0 fire boundary aft of the galley are not fire rated and do not meet the requirements of an A-0 class bulkhead as specified in the vessel's fire control plan. Vessel is limited to a maximum of 150 passengers until structural fire protection is restored."Old T" 46 CFR 177.10-5 & 46 CFR 72.05-25(b)(2)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 February 2026
Resolved 19 May 2026
Resolution: Operator emailed photos of modicifation to doors in accordance with approved plan to replace noncompliant windows with two plates of 11 guage steel.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 9 January 2026
Resolved
A hatch exposed to the weather must be watertight, except that a hatch on a vessel that operates only on protected waters may be weathertight. During 13May2025 annual inspection MI observed and documented starboard aft galley door corrosion compromised weathertight integrity. A corresponding worklist item was issued prior on 07Mar2025 in response to operator self reported plan to replace aft galley doors. Due date for said worklist item was extended and has lapsed. Demonstrate weathertight integrity of port and starboard aft galley doors to satisfaction of marine inspector. 46 CFR 116.1160(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2026
Resolved 17 February 2026
Resolution: Operator emailed photos of weathertight door installation.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 13 May 2025
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The hydrostatic release on the starboard middle IBA is expired. Maximum persons onboard reduced by 100 to 420. 46 CFR 117.130(a)(2)
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 May 2025
Resolved 27 May 2025
Resolution: Operator sent photo of new hydrostatic release installation. Photo uploaded to documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 May 2025
Resolved
A weathertight door must be provided for each opening located in a deck house. Pilot house door is not weathertight. 46 CFR 116.1160(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 27 May 2025
Resolution: Operator sent photo of weatherstripping installed on pilot house door. Photo uploaded to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 May 2024
Resolved
Each vessel certificated to operate on a lakes bays and sounds route must, if operated in cold water, be protected with life floats of 100% of total number of persons permitted on board. The vessel has 4 out of 6 IBAs requiring servicing. Restricted to operations within 1NM from shore or 200 total persons onboard.
46 CFR 117.207(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2024
Resolution: Verified IBA servicing
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 May 2024
Resolved
Each vessel must be provided with a visible and audible bilge level alarms at the operating station in each space provided in 46 CFR 119.530. Vessel's forpeak audible alarm for the bilge level is inop.
46 CFR 119.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 6 June 2024
Resolution: Received video of working audible alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024
Resolved
At each subsequent inspection for certification of a vessel the owner shall prepare for inspection of operation of main propulsion machinery. During the underway portion of the inspection, MI discovered excessive leaking from vessel's shaft seals.
46 CFR 115.804(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 6 June 2024
Resolution: Received video for vessel's shaft seals. The rate of drop for water has significantly improved.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 May 2024
Resolved
Marine employers shall establish programs for chemical testing for dangerous drugs for crew members on inspected vessels. Vessel to provide 2023 MIS report and provide a list of all crew members covered in drug testing program.
46 CFR 16.230(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 27 August 2024
Resolution: Produce MIS report, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2024
Resolved
At each subsequent inspection for certification the owner shall have the vessel ready for inspection of each portable fire extinguisher. Vessel's portable fire extinguisher aft of control station is inoperable.
46 CFR 115.810(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 6 June 2024
Resolution: Verified portable fire extinguisher installation.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 May 2024
Resolved
The general construction of the vessel shall be to minimize fire hazards in so far as reasonable and practicable. Vessel to re-install wasted/missing insulation stbd aft of machinery space.
46 CFR 177.10-5(a)
(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 28 June 2024
Resolution: Insulation verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2024
Resolved
The general construction of the vessel shall be to minimize fire hazards in so far as reasonable and practicable. Vessel to remove/rearrange all daisychained power strips in control station and 2nd deck band equipment area.
46 CFR 177.10-5(a)
(OLD T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 10 June 2024
Resolution: Verified removal of daisy chained power strips.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2024
Resolved
The general construction of the vessel shall be to minimize fire hazards in so far as reasonable and practicable. Space below control station was found to be in inadequate condition. Vessel to repair damaged lagging for AC unit and re organize cables to control station to the satisfaction of the cognizant OCMI.
46 CFR 177.10-5(a)
(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 6 June 2024
Resolution: Verified video for space below control station.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 15 May 2024
Resolved
The master shall conduct sufficient drills and instructions to ensure all crewmembers are familiar with their duties during emergencies that necessitate abandoning ship or recovery of persons who have fallen overboard or responding to a fire. Vessel's last recorded drill was in 2023.
46 CFR 122.520(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 10 June 2024
Resolution: Verified updated drill records.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 15 May 2024
Resolved
Waste paper baskets shall be constructed of approved incombustible materials with solid sides and botooms. Found multiple trash cans onboard constructed of combustible material. Vessel to replace trash cans or provide proof that trash cans are constructed of incombustible materials.
46 CFR 177.10-5(a) (OLD T)
46 CFR 72.05-55(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 28 June 2024
Resolution: Trash cans verified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2023
Resolved
Each ring life buoy must be marked with type II retro material approved IAW 164.018. Life rings missing retroflective tape.
46CFR122.604(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 15 June 2023
Resolution: Received photographs of retroreflective tape installed on life rings.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 May 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to crew and passengers. Vessel had no placards posted on the upper passenger deck.
46CFR122.516(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 15 June 2023
Resolution: Received photographs of properly posted life jacket donning placards.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2022
Resolved
Each hose must: Be lined commercial firehose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies” (incorporated by reference, see § 114.600 of this chapter), or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance. Fire hose on forward portion of second deck is damaged and leaking. Hose requires replacement of equivalent commercial grade.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 20 May 2022
Resolution: New firehose in place
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2022
Resolved
A vessel must be provided with satisfactory pumping arrangements for draining any watertight compartment under all practicable conditions. Bilge pump failed to actuate.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 May 2022
Resolution: Corrected suction issue. Improper sequence of valve openings caused initial problem.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 April 2021
Resolved
As appropriate for the intended voyage all vessels must carry adequate and up to date publications. Vessel's navigation rules are out of date. Replace with valid publication.
46 CFR 185.20-35
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of newly purchased Navigation Rules.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Vessel's surge protector on bridge is broken and needs replacement. Replace with new surge protector.
46 CFR 183.10-20(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of discarded surge protector and new one in place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Vessel is daisy chaining power strips on bridge console and near the stage area. Remove and replace with permanent wire installations.
46 CFR 183.10-20 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of removed daisy chain set up and replacement with permanent wire installation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 April 2021
Resolved
A hatch exposed to the weather must be watertight. Vessel's three (3) hatches on the main deck are not watertight and are missing securing devices. Make watertight and provide securing devices.
46 CFR 116.116 (a) & (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent pictures of refurbished watertight hatches with securing devices (3).
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 27 April 2021
Resolved
At each inspection the marine inspector shall examine all accessible parts of the hull. There is a steel hull failure on the main deck forward underneath the stairwell. Vessel must submit repair proposal for CG approval.
46 CFR 176.25-5(A)(i)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 3 July 2021
Resolution: Weld repair work completed.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 27 April 2021
Resolved
At each inspection the marine inspector shall inspect all railings and bulwarks. Vessels gangway has cracked weld and needs repair.
46 CFR 176.25-5 (A)(4)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 24 July 2021
Resolution: Weld repair completed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 27 April 2021
Resolved
Overcurrent protection shall be provided for each conductor for the purpose of opening the circuit if the current reaches a dangerous level. Vessel's distribution panels on the port side of the galley and the upper deck are improperly sized. These panels are to remain de-energized until properly sized over current protection is installed.
46 CFR 183.10-35
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent pictures of properly sized overcurrent protection where needed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 April 2021
Resolved
Cocks are prohibited for use in fuel lines except those of the solid bottom type. Vessel's drain cocks for fuel filters are not approved and leak fuel. Provide proper drains for fuel filters.
46 CFR 182.30-40 (A)(4)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of proper installed drains for the fuel filters.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 April 2021
Resolved
Each vessel must have adequate emergency lights fitted along the line of escape that are actuated automatically upon loss of power. Fix installed emergency lighting on vessel.
46 CFR 120.432 (A)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent pictures of fixed emergency lighting on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. Vessel's starboard engine has a leaking shaft packing gland. Replace packing gland.
46 CFR 182.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of replaced packing gland for starboard engine shaft.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021
Resolved
Each vessel if operated in cold water shall be provided with life floats or iba's of an aggregate capacity that will accomodate 100% of the total persons on board. Vessel only carries 300 person IBA. Reduced passenger count to 300 total persons on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2021
Resolution: Operator sent photos of IBA's correctly installed on vessel along with service receipts.
Passenger count restriction removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2021
Resolved
Battery terminal connections shall be made permanent. Battery terminals throughout vessel have loose connections. Tighten loose connections.
46 CFR 183.05-20 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of properly connected battery terminals.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020
Resolved
Each vessel operator must ensure that the approved Vessel Security Plan (VSP) and any approved revisions or amendments thereto, are onboard and made available to the Coast Guard upon request. Did not have most current version of VSP onboard. 33 CFR 104.120(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2020
Resolved 16 July 2020
Resolution: Operator printed up to date VSP and replaced the out dated version.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020
Resolved
The VSO must ensure that at least one security drill is conducted at least every 3 months. Discovered no 2020 documentation of security drills. 33 CFR 104.230(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2020
Resolved 17 July 2020
Resolution: Conducted security drilll during inspection, and operator provided forms for future log books.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020
Resolved
Security exercises must be conducted at least once each calendar year, with no more than 18 months between exercises. No documented security exercises onboard. Vessel must complete in 07 days. 33 CFR 104.230(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2020
Resolved 24 July 2020
Resolution: Operator logged security exercise and prooved knowledge to run proper secruity exercise.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 13 July 2020
Resolved
All machinery installed shall be maintained to afford adequate protection against fire, explosion, machinery failure and personnel injury. Grey water backup holding tanks discovered with unsecured tops and piping. 46 CFR 182.01-5 [Old T]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 3 August 2020
Resolution: Operator provided picture of secured tops on grey water tanks.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2020
Resolved
Openings through which conductors enter shall be adequately closed. Missing cover to junction box discovered in overhead of emergency exit of the aft engine room. 46 CFR 120.200
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 3 August 2020
Resolution: Operator provided picture of enclosed junction box.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 July 2020
Resolved
All escape hatches must be marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT KEEP CLEAR". Emergency exit of forward engine room not labeled from outside. 46 CFR 122.606
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 3 August 2020
Resolution: Operator provided picture of signage on outside of engine room emergency exit.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 July 2020
Resolved
The method of opening a means of escape must be obvious, rapid, and of adequate strength. Loose insulation in engine room overhead inhibits proper use of emergency exit. 46 CFR 116.500(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 3 August 2020
Resolution: Operator provided picture of secured insulation on inside of engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 13 July 2020
Resolved
At each vessel inspection, all observed unsafe practices and hazardous situations must be corrected. Numerous flammable materials stored near machinery and over piping in 3rd, 4th, 6th, and 8th compartments. 46 CFR 115.830(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 August 2020
Resolved 16 July 2020
Resolution: Operator properly stowed cargo in places safe from fire hazards.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 July 2020
Resolved
At each inspection, spaces may be examined to see that there is no excessive accumulation of oil that might cause a fire hazard. Oil accumulation in second compartment. 46 CFR 115.850
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2020
Resolved 16 July 2020
Resolution: Operator cleaned space.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 July 2020
Resolved
As appropriate for the intended voyage, a vessel must carry an adequate and up-to-date Coast Guard Light List. No updated light list onboard. 46 CFR 121.420(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2020
Resolved 16 July 2020
Resolution: Operator printed updated light list.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 July 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No updated charts onboard. 121.420(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Operator provided downloaded charts on phone.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2020
Resolved
At least one ring life buoy must be fitted with a lifeline. Ring buoy line was wasted. 46 CFR 117.70(c)(5)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2020
Resolved 16 July 2020
Resolution: Operator replaced line and reattached to ring.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2020
Resolved
Each ring life buoy must be stowed in a way that it can be rapidly cast loose. Ring buoy inhibited by hook on stern of first deck. 46 CFR 117.70(b)(3)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Vessel removed hook that was inhibiting ring buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020
Resolved
The CSO or VSO must ensure an audit of the VSP is performed annually. No security udit performed for 2020. Vessel given 07 days to complete. 33 CFR 415.(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2020
Resolved 24 July 2020
Resolution: Operator provided picture of audit conducted. Uploaded to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 May 2019
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Four of the vessel's hydrostatic release units are expired. Provide liferaft servicing report for proof of delay.
46 CFR 180.130
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 18 May 2019
Resolution: Vessel rep sent MI pictures of four new hydrostatic releases for vessel's IBAs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2019
Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats. One bracket in the pilothouse and one bracket in the engine room do not hold the extinguisher securely in its place.
46 CFR 162.028-3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 15 July 2019
Resolution: Vessel Rep re-sent MI picture of new brackets for both pilothouse and engine room extinguishers.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 17 May 2019
Resolved
The items contained in first-aid kit shall be as listed in Table 160.041-4(b). First Aid Kit onboard is missing ammonia inhalents and iodine applicator.
46 CFR 160.041-4(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 15 July 2019
Resolution: Vessel Rep sent MI pictures of new iodine applicators for first aid kit.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 May 2019
Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Lifesaving maintenance records were not available for inspection upon request.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 15 July 2019
Resolution: Vessel rep sent MI picture of Life-Saving inspection log with entries.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 May 2019
Resolved
Rugs and carpets are not permitted in machinery spaces, high risk service spaces, or areas where the spillage or leakage of flammable or combustible liquids is possible including areas immediately adjacent to bar service areas. Carpet in the vicinity of the bar on second deck must be removed by next year.
46 CFR 116.423 (a)(4)(ii)
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2020
Resolved 20 October 2020
Resolution: Operator replaced caqrpet with a vinyl flooring. Verified flooring is IAW 46CFR116.435(a)(2) and USCG approved.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 May 2019
Resolved
The VSO must ensure that at least one security drill is conducted at least every 3 months, except when a vessel is out of service due to repairs or seasonal suspension of operation provided that in such cases a drill must be conducted within one week of the vessel's reactivation. Security drill records were not available for inspection upon request.
33 CFR 104.230
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 May 2019
Resolved 17 May 2019
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2018
Resolved
Procure updated nautical chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2018
Resolved 31 May 2018
Resolution: Received documentation that a new chart has been procured.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2017
Resolved
Replace expired items in first aid kit.46CFR160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 April 2017
Resolution: Replaced expired items.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 April 2017
Resolved
Secure all CO2 bottles onboard the vessel. 46CFR118.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 April 2017
Resolution: Secured all CO2 bottles.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 April 2017
Resolved
Provide non-conducting deck covering in front of switchboard in engine room. 46CFR120.330
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 April 2017
Resolution: Provided non-coducting deck covering in front of switchboard.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 14 April 2017
Resolved
Provide proof of service of 2, 100 person IBA's. Passenger count reduced to 450 persons. 46CFR117.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 17 May 2017
Resolution: Provided servicing report & pictures of install of IBA's.
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 14 April 2017
Resolved
Provide proof of 5 panel testing.46CFR16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Provided 5 panel test.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 April 2017
Resolved
Adjust stuffing box to prevent excessive water leakage.46CFR115.802
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 April 2017
Resolution: Adjusted stuffing box to prevent excessive water leakage.