Records from 1984 to 2016. Most recent: inspection, 31 August 2016.
Inspection history · 53
31 August 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5989021
9 October 2015
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5739757
21 September 2015
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5756372
21 May 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4822094
14 June 2012
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4343971
21 February 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3422263
19 August 2008
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3303165
22 August 2006
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2762143
26 August 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2475398
13 August 2004
COC-MODU Renew · Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2165508
3 November 2003
Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1943937
12 August 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1662791
15 January 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1478689
20 August 2001
Damage Survey · Letter of Compliance (Initial/Renewal)
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1420559
26 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075010
21 March 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1436331
8 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801770
3 February 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395102
6 January 1999
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809970
4 October 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 3906
29 July 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 795264
12 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 75808
11 February 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455559
27 November 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 128035
21 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774615
12 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785122
11 November 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 18414
28 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785100
18 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783248
7 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 149038
23 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115408
14 February 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418091
23 February 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435728
16 March 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453111
19 December 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 699967
11 December 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 100705
11 July 1994
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1175281
5 May 1994
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1409128
22 March 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1412619
29 May 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1221232
31 December 1990
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 921146
11 July 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 928090
14 June 1990
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1239615
14 June 1989
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1195126
17 June 1988
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 896838
22 September 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013859
9 June 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333618
11 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1297073
25 March 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1307589
9 October 1985
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 993692
17 June 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993069
4 January 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1284077
23 February 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1278965
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 March 2014
Resolved
It was revealed that the VSL's #1 lifeboat was condemned during recent inspection by third party. Coast guard was not notified about the issue.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 23 May 2014
Resolution: New lifeboat was furnished and pictures provided proving installation.
Electrical › Electric Generation Source (emergency) › Switch
Issued 24 March 2014
Resolved
Emergency shutdown on e-gen is not working.
Condition: Improper/Lack of Maintenance
Due 5 June 2014
Resolved 11 June 2014
Resolution: Recieved photos and verification that the e-gen emergency stop is funtional.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 March 2014
Resolved
Lighting at embarkation stations takes over 10 minutes to illuminate when the e-gen is energized. Replace with units that illuminate immediately.
Condition: Placed in Improper Service
Due 5 June 2014
Resolved 27 June 2014
Resolution: LEDs furnished at embarkation stations and illumitate immediately upon energizing.
Lifesaving › Liferaft Equipment › Instructions (immediate action)
Issued 24 March 2014
Resolved
Lifeboat gear stowage was improper. Gear adrift all over the boat, some covering seats. Require proper placement of gear.
Condition: Improper Installation
Due 29 May 2014
Resolved 12 June 2014
Resolution: Gear has been reconfigured to a better stowage arrangement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2012
Resolved
Vessel has large cluster of electrical wiring hanging low over egress route on main deck aft of the house. Vessel is required to install adequate supports for the electrical installation to prevent wiring from falling onto deck.
Due 31 August 2012
Resolved 3 August 2012
Resolution: Received photos of proper support for electrical wiring from OIM.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 3 November 2003
Resolved
Prove operation of overspeed trip on #1 MDE.
Condition: Improper/Lack of Maintenance
Due 10 November 2003
Resolved 5 November 2003
Lifesaving › Lifeboat
Issued 12 August 2002
Resolved
Strip and Clean and change out fuel or provide documentation these items have been completed for #1 and #2 lifeboats prior to 12 September 2002.
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 13 August 2002
Resolution: Boats stripped & cleaned , fuel changed, notice via fax.
Lifesaving › Launching Appliances
Issued 12 August 2002
Resolved
Provide documentation for #1 and #2 lifeboat davit falls (wire rope) date of installation prior to 12 September 2002. LEGACY COMPONENT DESC: Falls
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 11 September 2002
Resolution: Certs provided for falls via fax.
Engineering
Issued 20 August 2001
Resolved
Install a machinery guard over the rotating coupling on #1 generator.
Condition: Unknown
Due 20 September 2001
Resolved 16 October 2016
Resolution: cleared 835
Documentation
Issued 20 August 2001
Resolved
33 CFR 146.140 - Provide an Emergency Evacuation Plan for approval by the OCMI having authority over the zone where the rig is operating. This requirement is to be completed prior to beginning drilling operations.
Condition: Unknown
Due 27 August 2001
Resolved 15 January 2002
Resolution: As per phone con with Greg Daigle
Lifesaving
Issued 21 March 2000
Resolved
REMOVE OIL AND OILY RAGS FROM BILGE IN MOTOR ROOM.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Electrical
Issued 21 March 2000
Resolved
PROVE PROPER OPERATION OF #3 GENERATOR, AFTER INSTALLATION.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Construction/Loadline
Issued 21 March 2000
Resolved
IN ELECTRICAL WORKSHOP - CROP AND RENEW WASTED OVERHEAD TO THE SATISFACTIONOF THE COGNIZANT OCMI.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Deck/Cargo
Issued 21 March 2000
Resolved
STENCIL NAME CHANGE ON HELIPORT, FIRE CONTROL PLAN AND RELATED EQUIPMENT.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Construction/Loadline
Issued 21 March 2000
Resolved
MAKE REPAIRS TO HELIPORT IAW 46CFR 108.235 (12 HOLES IN DECK). REPAIRS TO BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Engineering
Issued 3 February 1999
Resolved
REPLACE ALL FUEL SUPPLY/RETURN FLEX LINES ON ALL 5 ENGINES AND EMERGENCY GENERATOR.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Lifesaving
Issued 3 February 1999
Resolved
CONDUCT 1.1 OPERATIONAL TEST OF ALL LIFEBOAT RELEASE GEARS OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL OCMI.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Deck/Cargo
Issued 3 February 1999
Resolved
HAVE USCG, ICGB, OR CLASS SOCIETY CONDUCT OR PROVIDE PROOF OF ANNUAL CRANE INSPECTIONS.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Electrical
Issued 3 February 1999
Resolved
INSTALL LIFERAFT EMBARKATION LIGHT TO SHINE AT WATER LEVEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Lifesaving
Issued 11 February 1998
Resolved
Renew falls on each life capsule. Conduct 110% weight test and 1.1 operational release gear test to the satisfaction of the attending class surveyor.
Condition: Unknown
Due 5 March 1998
Resolved 9 March 1998
Lifesaving
Issued 11 February 1998
Resolved
Provide missing abandonment training material as outlined in 46 CFR 109.213(a).
Condition: Unknown
Due 13 February 1998
Resolved 17 February 1998
Electrical
Issued 11 February 1998
Resolved
Repair electrical malfunction on main AC switchboard. Conduct satisfactory test of reverse-power-relay system on all AC generators.
Condition: Unknown
Due 11 March 1998
Resolved 30 March 1998
Fire Fighting
Issued 11 February 1998
Resolved
Hydrostatically test SCBA bottle at station #1.
Condition: Unknown
Due 25 February 1998
Resolved 27 February 1998
Lifesaving
Issued 11 February 1998
Resolved
Provide 1500-foot auxiliary line for line-throwing apparatus.
Condition: Unknown
Due 23 February 1998
Resolved 27 February 1998
Fire Fighting
Issued 11 February 1998
Resolved
Make door from stairtower to galley self-closing and latch.
Condition: Unknown
Due 23 February 1998
Resolved 27 February 1998
Electrical
Issued 11 February 1998
Resolved
Conduct emergency total rig shutdown test.
Condition: Unknown
Due 22 February 1998
Resolved 27 February 1998
Lifesaving
Issued 11 February 1998
Resolved
Provide twelve hand-held flares, twelve parachute flares and two floating orange smoke signals for each life capsule.
Condition: Unknown
Due 20 February 1998
Resolved 27 February 1998
Lifesaving
Issued 11 February 1998
Resolved
Make repairs to liferaft embarkation deck support structure to the satisfaction of attending class surveyor and submit report to [name withheld], or remove davit-launched rafts and provide 100% aggregate capacity inlifeboats for each side.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Documentation
Issued 11 February 1998
Resolved
Submit to [name withheld], valid Safe Manning Certificate issued by flag state. Complete prior to rig movement.
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Deck/Cargo
Issued 11 February 1998
Resolved
Gauge bottoms and lower sections of dry bulk tanks and submit repair proposal to classification society for approval. Provide copy of repair report and class approval to [name withheld].
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Documentation
Issued 11 February 1998
Resolved
Revise Safety Plan and submit to classification society for approval.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Lifesaving
Issued 14 February 1997
Resolved
MAKE REPAIRS, ALTERATIONS AND REVISIONS TO POLICY TO COMPLY WITH REVISIONS TO 46 CFR 107-109. REFERENCE WORKLIST ISSUED TO OIM ON 14FEB97 AND FEDERAL REGISTER, VOL. 61, NO. 98, DATED 20MAY96.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Construction/Loadline
Issued 14 February 1997
Resolved
PAINT CORRECT NAME ON RIG HULL, HELIPORT, AND OTHER LOCATIONS AS NECESSARY.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Electrical
Issued 14 February 1997
Resolved
REPAIR EMERGENCY LIGHTING (REPLACE BATTERIES) THROUGHOUT RIG. LABEL ALL EMERGENCY LIGHTING.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Electrical
Issued 14 February 1997
Resolved
PLACE METAL BANDINGS ON DRILL FLOOR / MUD PIT WIRING.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Electrical
Issued 14 February 1997
Resolved
REPAIR GENERATOR #6 AND TURBO LEAK ON GENERATOR #2.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997
Resolved
PLACE FUEL TRANSFER PROCEDURES AT TRANSFER STATION AND FUEL PUMPS.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Fire Fighting
Issued 14 February 1997
Resolved
INSTALL GENERAL ALARM BELLS UNDER LIFE BOAT #1 AND ADJACENT TO AFT LEG IN AREAS WHERE GENERAL ALARM CANNOT BE HEARD.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Lifesaving
Issued 14 February 1997
Resolved
INSTALL RIGID ESCAPE LADDERS TO WATER.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Fire Fighting
Issued 14 February 1997
Resolved
PLACE SPARE SCBA BOTTLES ON BOARD.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Documentation
Issued 14 February 1997
Resolved
PROVIDE WASTE MANAGEMENT PLAN AND SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997
Resolved
CONDUCT THE FOLLOWING REQUIRED TESTS / MAINTENANCE ITEMS AND LOG: TWO HOUR EMERGENCY BATTERY LOAD TEST, STRIP AND CLEAN LIFEBOATS, LIFEBOAT WINCH INSPECTION.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Lifesaving
Issued 14 February 1997
Resolved
INSTALL 100 PSI RELIEF VALVES ON HOT WATER HEATERS AND FRESH WATER TANK.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Lifesaving
Issued 14 February 1997
Resolved
REPLACE WINDSOCK ON HELIPORT.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Fire Fighting
Issued 14 February 1997
Resolved
MAKE REPAIRS TO FIRE FIGHTING AND LIFESAVING EQUIPMENT DETAILED IN SOTEC SERVICING REPORT, DATED 29DEC97.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Engineering
Issued 14 February 1997
Resolved
REPACK / REPLACE SALTWATER SUPPLY VALVE.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Navigation
Issued 14 February 1997
Resolved
REPAIR FOG HORN.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Accommodation/Occupational Safety
Issued 14 February 1997
Resolved
REPLACE CEILING TILES AS NECESSARY, ADJUST SELF-CLOSING DOOR TO GALLEY, CLEAN VENT AREA AND FAN MOTOR ABOVE GALLEY RANGE, REPAIR LOOSE LOCKSETS AS NECESSARY, PROVIDE BUNK LIGHTS FOR ALL BUNKS.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Lifesaving
Issued 14 February 1997
Resolved
CALIBRATE O2 / LEL METERS.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Lifesaving
Issued 23 February 1996
Resolved
HAVE ANNUAL SERVICING AND TESTING PERFORMED ON LIFERAFT #1 AND LIFERAFT RELEASING HOOK.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Fire Fighting
Issued 23 February 1996
Resolved
REMOVE ALL EXTERNAL WASHDOWN CONNECTIONS AT ALL FIRE HOSE HYDRANT STATIONS.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Construction/Loadline
Issued 23 February 1996
Resolved
REPAIR CRACKED WELDS IN DECK INSERT OVER MUD PUMP #1.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Electrical
Issued 23 February 1996
Resolved
SECURE LOOSE ELECTRICAL JUNCTION BOXES ON DRILL FLOOR.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Lifesaving
Issued 23 February 1996
Resolved
PROPERLY SECURE LADDER FROM TOP OF MOTOR SHED ABOVE DRILL FLOOR GOING UP DERRICK.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Lifesaving
Issued 23 February 1996
Resolved
LABEL GENERAL ALARM BELL IN SHAKER HOUSE.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Electrical
Issued 23 February 1996
Resolved
INSTALL BLANKS TO COVER OPENINGS IN TWO (2) DISTRIBUTION PANELS BEHIND MAINSWITCHBOARD.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Electrical
Issued 23 February 1996
Resolved
TEST EMERGENCY DRILLING OPERATIONS SHUT DOWN.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Lifesaving
Issued 23 February 1996
Resolved
PERFORM WEIGHT TEST ON LIFERAFT DAVIT TO THE SATISFACTION OF THE ATTENDING FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Documentation
Issued 23 February 1996
Resolved
PROVIDE ONBOARD APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP).
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Electrical
Issued 23 February 1996
Resolved
REPAIR PURGE ALARM ON BAYTRON BOX ON DRILL FLOOR.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Engineering
Issued 23 February 1996
Resolved
PERFORM ANNUAL HYDROTEST ON FUEL TRANSFER HOSE TO 1.5 TIMES THE M.A.W.P.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Unknown
Issued 23 February 1996
Resolved
PROVIDE ONBOARD NAVTEX RECEIVER FOR RIG AND RADAR TRANSPONDERS FOR EACH LIFEBOAT.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Accommodation/Occupational Safety
Issued 23 February 1996
Resolved
PERFORM INTERNAL EXAMINATION AND TEST SAFETY RELIEF VALVES ON ALL AIR RECEIVERS TO THE SATISFACTION OF THE ATTENDING FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Lifesaving
Issued 23 February 1996
Resolved
INSTALL STANSIONS AND SAFETY CHAINS AT OPENINGS FOR BOTH LIFEBOAT STATIONS.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Electrical
Issued 23 February 1996
Resolved
INSTALL LIGHT ON EMERGENCY CIRCUIT THAT ILLUMINATES DOWN TOWARD THE WATER FOR LIFEBOAT #1.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Electrical
Issued 23 February 1996
Resolved
PROPERLY SECURE PERMANENTLY INSTALLED ARMORED CABLE RUNS ON DRILL FLOOR.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Unknown
Issued 22 March 1994
Resolved
Repair and prove proper operation of galley sanitizer.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Navigation
Issued 22 March 1994
Resolved
Repair and prove proper operation of Navigation lighting in way of correct bulbs and properly functioning bulb switching mechanisms prior to commencing OCS operations.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Conduct NDT on all fabrication and installation welding in way of Survival Capsule Launching structures prior to placing Capsules into service.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Repair and prove proper operation of both Survival Capsule launching winches, brake assemblies and interlocks prior to conducting weight testing.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Prove Plan Review and Acceptance by the American Bureau Of Shipping prior to placing Survival Capsules into service.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Conduct Weight Testing of Survival Capsule prior to placing Capsules into service.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Prove servicing of both Survival Capsules by Approved Servicing Facility prior to placing capsules into service.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Navigation
Issued 22 March 1994
Resolved
Repair and prove proper operation of Automatic Function Mode of Foghorn prior to commencing OCS operations.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Provide MSHA Approved Medical Kit equipped for a minimum of fifty (50) personnel prior to commencing OCS Operations.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Fire Fighting
Issued 22 March 1994
Resolved
Install and prove proper operation of fixed mechanical means to extinguish deep fat fryer fire.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Provide proper Impulse Projectile Line Throwing Gun prior to commencing OCSoperations.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Documentation
Issued 22 March 1994
Resolved
Upon correction of Deficiency Number 15, submit updated corrections to Operations Manual reflecting additional emergency equipment capability and prescribed uses.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Place into service lifeboats of sufficient aggregate capacity to accomodate100% of crew capacity.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Provide standby vessel meeting requirements of 33 CFR 143 until such time as Deficiency Number 15 is corrected.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Construction/Loadline
Issued 22 March 1994
Resolved
Provide copy of ABS Acceptance regarding Temporary Repairs to wasted structural members in way of #3 Void.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Install and prove proper operation of Survival Capsule Emergency Lighting prior to placing capsules into service.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
Renew falls cables for both Survival Capsule launching winches prior to placing Capsules into service.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Accommodation/Occupational Safety
Issued 22 September 1987
Resolved
OMNIPURE UNIT MUST BE IN WORKING ORDER. REPAIR AND PROVE OPERATION TO USCGINSPECTOR. NAVC 4-78
Condition: Unknown
Due 22 September 1987
Resolved 22 September 1987
Engineering
Issued 22 September 1987
Resolved
PROVIDE NAME PLATE DATE FOR DRILL FLOOR AIR RECEIVER; I.E., MAXIMUM ALLOWABLE WORKING PRESSURE, ASME NUMBER. NAVC 4-78 3.D(11)
Condition: Unknown
Due 22 September 1987
Resolved 22 September 1987
Engineering
Issued 9 June 1987
Resolved
PROVIDE NAME PLATE DATA FOR DRILL FLOOR AIR RECEIVER; EI, MAXIMUM ALLOWABLEWORKING PRESSURE, ASME NUMBER. NAVC 4-78 3.D(11)
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Navigation
Issued 9 June 1987
Resolved
REPAIR/INSTALL PORT AND STARBOARD RUNNING LIGHTS IN ACCORDANCE WITH ANNEX I OF THE INTERNATIONAL COLREGS 1972 FOR SIDE LIGHTS.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Fire Fighting
Issued 9 June 1987
Resolved
CARBON DIOXIDE CYLINDER FOR PAINT LOCKER FIRE EXTINGUISHING SYSTEM REQUIRESHYDROSTATIC TESTING. TECH NOTE 1/83-8.7
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Accommodation/Occupational Safety
Issued 9 June 1987
Resolved
REPAIR/INSTALL DOGS TO VENTILATION CLOSURES ON MAIN DECK WHERE REQUIRED. TECH NOTE 1/83-8.7
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 9 June 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 9 June 1987
Resolved
REPAIR BROKEN WELD TO BRACE FOR PORT SIDE BOARDING LADDER. NAVC 4-78 CHANGE1 46 CFR 108.525 APPLIES.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 9 June 1987
Resolved
MAKE OPERABLE THE WINCH BRAKE ASSEMBLY FOR THE DAVIT LAUNCH LIFE RAFTS. NAVC 4-78 CHANGE 1 46 CFR 107.239 APPLIES.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 9 June 1987
Resolved
DAVIT LAUNCH LIFERAFT STATION TO BE WEIGHT TESTED (4500 LBS) AND DAVIT HOOKTO BE WEIGHT TESTED IN THE PRESENCE OF A USCG INSPECTOR. NAVC 4-78 CHANGE 146 CFR 107.239 APPLIES.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Electrical
Issued 9 June 1987
Resolved
REPAIR LEAKING EXHAUST PIPE ON DIESEL NO. 4. TECH NOTE 1/83 6.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Documentation
Issued 9 June 1987
Resolved
PROVIDE COPY OF VALID PANAMANIAN MOBILE OFFSHORE DRILLING UNIT CERTIFICATE.TECH NOTE 1/83
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Electrical
Issued 9 June 1987
Resolved
PROVIDE CHOCKS TO EMERGENCY BATTERIES. NAVC 4-78 CHANGE 1 46 CFR 111.15-5 APPLIES.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 9 June 1987
Resolved
REPAIR AND MAINTAIN IN A READINESS CONDITION THE RIGS RESCUE BOAT (IE. INFLATE, EQUIP PROPERLY, CHANGE FUEL, ETC.)
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 9 June 1987
Resolved
TEST FIRE AND LOG FIRING OF LINE THROWING GUN. PROVIDE TWO ADDITIONAL SERVICE LINES AND A TOTAL OF 25 CARTRIDGES TO KIT. NAVC 4-78 CHANGE 1 46 CFR 108.517 APPLIES.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Deck/Cargo
Issued 9 June 1987
Resolved
BOTH CRANES TO HAVE AN ANNUAL SERVICE INSPECTION COMPLETED BY A DULY AUTHORIZED PERSON OR ORGANIZATION IN ACCORDANCE WITH THE PANAMANIAN MODU CODE (CRANE SECTION) AND IMO MODU CODE, SECTION 12.1.5
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Construction/Loadline
Issued 9 June 1987
Resolved
REPLACE WIND SOCK ON HELO DECK. NAVC 4-78 CHANGE 1 108.241 APPLIES.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Accommodation/Occupational Safety
Issued 9 June 1987
Resolved
OMNIPURE UNIT MUST BE IN WORKING ORDER. REPAIR AND PROVE OPERATION TO USCG INSPECTOR. NAVC 4-78
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Electrical
Issued 9 June 1987
Resolved
PROVIDE PROPER ARMOR SHEALD CABLE FROM DRILL FLOOR GENERAL ALARM CONTACT MAKER. CABLE TO BE PROPERLY SECURED TO BULKHEAD. NAVC 4-78 46 CFR 108.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Fire Fighting
Issued 9 June 1987
Resolved
PROVIDE A FOUR FOOT APPLICATOR TO FIRE STATION BY WATER MAKE AND FREE UP HYDRANT VALVE. TECH NOTE 1/83 8.7
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 11 June 1986
Resolved
REPAIR THE INOPERATIVE MOTOR ON THE RESCUE BOAT.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Electrical
Issued 11 June 1986
Resolved
ENSURE THAT ALL EMERGENCY LIGHT FIXTURES ARE MARKED WITH AN "E".
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Electrical
Issued 11 June 1986
Resolved
REPAIR THE INOPERABLE GENERAL ALARM BELL ON THE FORWARD SIDE OF THE QUARTERS.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Electrical
Issued 11 June 1986
Resolved
REPLACE ALL THE INOPERABLE EMERGENCY LIGHT BATTERIES.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
PROVIDE LAUNCHING INSTRUCTIONS FOR LIFE RAFT STATIONS #1, #2 & #3.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Navigation
Issued 11 June 1986
Resolved
LEVEL ALL OBSTRUCTION LIGHTS.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
PROVIDE A TOTAL OF 25 CARTRIDGES FOR THE LINE THROWING GUN.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
PROVIDE A SERVICEABLE SMOKE CANISTER FOR THE STBD RING BUOY.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
PROVIDE 12 SERVICEABLE HAND HELD ROCKET PROPELLED RED FLARES.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
PROVIDE ONE ADDITIONAL APPROVED LIFE JACKET TO MAKE A TOTAL OF 58 ON BOARD.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
PROVIDE SERVICED LIFERAFTS FOR THE #2 AND #3 LIFERAFT STATIONS.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
UNTIL THE #2 DAVIT LAUNCHED LIFERAFT IS RETURNED FROM SERVICING, PROVIDE A HYDROSTATIC RELEASE FOR THE SPARE THROW-OVER RAFT WHICH IS AT ITS STATION.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Lifesaving
Issued 11 June 1986
Resolved
REPLACE THE UNSERVICEABLE RING BUOY UNDER THE DRILL FLOOR.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Deck/Cargo
Issued 9 October 1985
Resolved
INSTALL EMBARKATION LIGHT AT THE DAVIT LAUNCHED LIFERAFT STATION.
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985
Lifesaving
Issued 9 October 1985
Resolved
REPLACE THE LAUNCH INSTRUCTIONS ON THE DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985
Unknown
Issued 17 June 1985
Resolved
REPLACE AND/OR INSTALL PROPER METAL BANDING STRAPS ON ALL ELECTRICAL CABLE RUNS. SEE 46 CFR 111.60-5.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
REPAIR ENERGENCY LIGHT AT STARBOARD DAVIT LAUNCH LOCATION. SEE 46 CFR 111.75-16.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
PROVIDE SERVICE REPORT FOR ALL FIRE EXTINGUISHERS. SEE 46 CFR 108.493.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
PROVIDE CRANE HAND SIGNAL INSTRUCTIONS AT ALL CRANE OPERATIONS LOCATIONS. SEE 46 CFR 108.601.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
PROVIDE PROPER COVERS FOR ALL OVERHEAD AND BUNK LIGHTS. SEE 46 CFR 108.203(I).
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
REPLACE RELIEF VALVE ON #2 P-TANK. SEE 46 CFR 54.15.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
PROVIDE BUNK LIGHTS FOR ALL BUNKS FOR ALL BUNKS IN SIX MAN ROOMS. PROVIDE SMOKE DETECTORS IN ALL ACCOMMODATIONS. SEE NVIC 4-78.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
REALIGN THE PORT RUNNING LIGHT AND PROVIDE DIAMOND DAY SHAPE. SEE COLREGS.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
CAP OR PLUG DRAIN VALVE UNDER DIESEL FUEL DAY TANK AT #4 GENERATOR. SEE 46 CFR 56.50-75.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
FOR COMPLIANCE WITH POLLUTION REGULATIONS: (A) PROVIDE OIL RECORD BOOK, 33 CFR 151.25. (B) DESIGNATE PERSON IN CHARGE, 33 CFR 155.700. (C) PRO- VIDE OIL TRANSFER PROCEDURES, SEE 33 CFR 155.720. (D) MAINTAIN HOSE RECORDS, SEE 33 CFR 155.800.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
PROVIDE GUARDS FOR FOUR AIR TUGGERS LOCATED UNDER DRILL FLOOR. SEE 46 CFR 108.705.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
REPAIR AND MAKE OPERATIONAL, GENERAL ALARM BELL ON FORWARD DECK HOUSE MAIN DECK. SEE 46 CFR 113.25.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Unknown
Issued 17 June 1985
Resolved
REMOVE ALL UNAUTHORIZED ELECTRICAL WIRE SPLICES ON POWER LEADS. SEE 46 CFR 111.60.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Documentation
Issued 4 January 1985
Resolved
OBTAIN AND POST LETTER OF COMPLIANCE ISSUED BY PORT ARTHUR, TX. DATED 19JUN84 AND PROVIDE A COPY OF SAME LETTER TO THIS OFFICE WITHIN THIRYT (30)DAYS.
Condition: Unknown
Due 4 January 1985
Resolved 4 January 1985