Records from 1982 to 2003. Most recent: inspection, 27 June 2003.
Inspection history · 47
27 June 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1828147
11 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1742839
1 November 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1709090
14 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1486726
2 August 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376660
18 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073077
23 March 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816707
7 February 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384354
17 August 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 780436
16 July 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395228
1 April 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121068
1 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814900
4 December 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378520
12 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 75808
10 February 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381189
17 December 1996
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1184742
30 August 1996
Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254338
1 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 231948
13 June 1996
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396532
3 August 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1360324
27 July 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 665876
23 July 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 14741
12 July 1994
Examination of Repairs · Damage Survey · Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362969
27 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 4842
31 March 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855653
21 October 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 963154
24 September 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153197
15 July 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844013
30 April 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154035
29 April 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152090
3 June 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830170
7 May 1991
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234800
26 November 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909154
24 September 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 902344
21 August 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 908228
18 September 1989
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341997
12 September 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040464
12 September 1988
COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043300
13 October 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012383
10 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324520
12 November 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326473
30 September 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010905
12 September 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006983
12 September 1986
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325537
18 October 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299803
22 September 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 974713
21 September 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272609
Engineering
Issued 11 February 2003
Resolved
PROVIDE AND INSTALL HEAT SHEILD FOR BULK COMPRESSOR LINES EXPOSED TO PERSONAL. LEGACY COMPONENT DESC: BULK AIR COMPRESSOR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2003
Resolved 12 February 2003
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 February 2003
Resolved
RENEW BATTERIES IN DIM EMERGENCY LIGHTS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2003
Resolved 12 February 2003
Communications › Internal Communications System
Issued 15 February 2002
Resolved
DEMONONSTRATE PROPER OPERATION OF THE ENGINE ROOM SOUND POWERED PHONE VISUAL / AUDIBLE CALL INDICATOR UNDER FINAL EMERGECNY POWER. LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper Installation
Due 15 March 2002
Resolved 11 February 2003
Lifesaving › Line-Throwing Appliances
Issued 15 February 2002
Resolved
PROPERLY CLEAN LINE THROWING GUN LEGACY COMPONENT DESC: Projectiles
Condition: Improper/Lack of Maintenance
Due 15 February 2002
Resolved 15 February 2002
Construction/Loadline › Structures › Door
Issued 15 February 2002
Resolved
PROPERLY ADJUST 01 LEVEL WEATERHTUGHT DOORS.
Condition: Improper/Lack of Maintenance
Due 15 February 2002
Resolved 15 February 2002
Lifesaving › Inflatable Liferafts
Issued 15 February 2002
Resolved
PROPERLY REPAIR BOTH LIFEFLOAT CRADLES PRIOR TO SAILING LEGACY COMPONENT DESC: CRADLE
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2002
Resolved 15 February 2002
Construction/Loadline › Structures › Ventilators
Issued 15 February 2002
Resolved
PROVIDE COVERS FOR ALL VENT INTAKES AND EXHAUSTS.
Condition: Improper Installation
Due 15 February 2002
Resolved 15 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 15 February 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE EMERGENCY STOPS FOR THE FUEL OIL PURIFIER, AND FUEL PRIMING PUMP. LEGACY COMPONENT DESC: Oily Mixture Discharge Pump
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2002
Resolved 11 February 2003
Engineering › Fuel Oil Service System › Hose
Issued 15 February 2002
Resolved
RENEW STBD MAIN ENGINE FUEL OIL SERVICE FLEXIBLE HOSE
Condition: Improper/Lack of Maintenance
Due 15 February 2002
Resolved 15 February 2002
Accommodation/Occupational Safety › Potable Water System
Issued 15 February 2002
Resolved
PROPERLY SECURE BOTH PRESSURE TANKS FOR THE POTABLE WATER SYSTEM LEGACY COMPONENT DESC: PRESSURE TANK
Condition: Improper/Lack of Maintenance
Due 15 February 2002
Resolved 15 February 2002
Fire Fighting
Issued 7 February 2000
Resolved
PROVIDE FOR APPROVAL AN UPDATED FIRE SAFETY PLAN, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Engineering
Issued 7 February 2000
Resolved
PROVIDE COPY OF VSL SPECIFIC FUEL OIL TRANSFER PROCEDURE CONTAINING REQUIRED INFORMATION LISTED IN 33 CFR 155, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Fire Fighting
Issued 16 July 1999
Resolved
INSTALL ONE ADDITIONAL PORTABLE FIRE EXTINGUISHER AS PER SUBCHAPTER "L".
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Lifesaving
Issued 16 July 1999
Resolved
INSTALL 2 ADDITIONAL LIFERING BOUYS AS PER SUBCHAPTER "L".
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Documentation
Issued 16 July 1999
Resolved
PROVE DAMAGE STABILITY TO THE MARINE SAFETY CENTER IN ACCORDANCE WITH SUBCHAPTER "L".
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Lifesaving
Issued 4 December 1998
Resolved
PROVIDE RESCUE BOAT EMBARKATION, LAUNCHING AND RECOVERY ARRANGEMENT IAW 46CFR133.160
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Lifesaving
Issued 4 December 1998
Resolved
PROVIDE PROPER RESCUE BOAT IAW 46CFR133.135
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Lifesaving
Issued 4 December 1998
Resolved
PROVIDE STOWAGE IAW 46CFR133.140
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Engineering
Issued 12 July 1994
Resolved
AIR SEAL TO CHANGE THE MAIN ENGINE FROM FULL AHEAD TO FULL ASTERN HAD A HOLE IN IT.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Construction/Loadline
Issued 12 July 1994
Resolved
REPLACE 3' X 5' OF DECK PLATE AT MIDBODY AT THE #2 STARBOARD FUEL TANK. REPLACE APPROPRIATE AREA OF SIDE SHELL.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Documentation
Issued 30 April 1993
Resolved
PROVIDE A COPY OF VESSEL'S PROVISIONAL LOADLINE CERTIFICATE UPON COMPLETIONOF THE ABS LOADLINE SURVEY TO MIO NEW YORK.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Navigation
Issued 30 April 1993
Resolved
REPAIR VESSEL'S GYRO COMPASS.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Construction/Loadline
Issued 30 April 1993
Resolved
VESSEL IS TO PROCEED TO THE PORT OF DOUALA CAMEROON FOR THE PURPOSE OF MAKING THE FOLLOWING REPAIRS: A. INSERT NEW STEEL PLATING IN WAY OF WASTED BOW THRUSTER TUNNEL. B. INSERT NEW STEEL PLATING IN WAY OF WASTED BOTTOM PLATING IN NO. 2 & 3 STB WATER BALLAST TANKS.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Construction/Loadline
Issued 30 April 1993
Resolved
REPAIR AS NECESSARY KEEL COOLERS BASED ON PRESSURE TEST. THE VESSEL SHALL NOT CARRY FREIGHT OR PASSENGERS DURING THE VOYAGE TO DOUALA CAMEROON OR_x001C_ PRIOR TO COMPLETING THIS ITEM TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Construction/Loadline
Issued 29 April 1993
Resolved
PROVIDE TO [name withheld], AN ABS REPORT CONCERNING THE SATISFACTORY REPAIRSTO HULL PLATING UNDERNEATH KEEL COOLER.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Documentation
Issued 7 May 1991
Resolved
PROVIDE ON BOARD A NEW LOADLINE CERTIFICATE SHOWING THE NEW VESSEL NAME._x001C_ PROVIDE A COPY TO THE COGNIZANT OCMI.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Accommodation/Occupational Safety
Issued 21 August 1990
Resolved
MAKE SIX (6) DRY BULK P-TANKS AVAILABLE FOR INTERNAL INSPECTION. TANKS TO BE CLEANED AND CERTIFIED BY A MARINE CHEMIST IN ACCORDANCE WITH MSO NEW ORLEANS INSPECTION MEMO #15.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990
Fire Fighting
Issued 21 August 1990
Resolved
SUBMIT FOR APPROVAL THE FIRE CONTROL SAFETY PLAN DATED 20AUG90.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990
Lifesaving
Issued 12 September 1986
Resolved
HAVE VESSEL'S LIFERAFTS SERVICED, PRIOR TO SERVICE DUE DATE. PROVIDE A COPY OF SERVICE RECORD TO INSPECTOR (MIDET MORGAN CITY, LA.).
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Lifesaving
Issued 12 September 1986
Resolved
HOLD AND LOG A FIRE DRILL, WHEN VESSEL HAS A PERMANENT CREW ABOARD, AND PRIOR TO VESSEL GETTING UNDERWAY ON A JOB.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Lifesaving
Issued 12 September 1986
Resolved
HAVE VESSEL'S LIFERAFTS SERVICED, PRIOR TO SERVICE DUE DATE, PROVIDE COPY OF SERVICE TO INSPECTOR (MIDET MORGAN CITY).
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Lifesaving
Issued 12 September 1986
Resolved
HOLD AND LOG A FIRE DRILL, WHEN VESSEL HAS A PERMANENT CREW ABOARD, AND PRIOR TO VESSEL GETTING UNDERWAY ON A JOB.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Engineering
Issued 22 September 1984
Resolved
PROVE PROPER OPERATION OF THE ENGINE ROOM ALARM PANEL AND ASSOCIATED MAIN ENGINE SHUTDOWNS AND SHAFT RPM INDICATORS IN THE PILOT HOUSE.
Condition: Unknown
Due 22 September 1984
Resolved 22 September 1984