Records from 2012 to 2026. Most recent: inspection, 11 March 2026.
Inspection history · 25
11 March 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8314407
7 April 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8106500
25 February 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8084375
20 November 2024
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8037834
24 July 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7965887
8 February 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7862837
14 November 2023
Administrative Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7824516
26 January 2023
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7620332
29 November 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7600862
3 January 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7374997
19 May 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7203076
18 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7141696
12 November 2020
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7093932
14 November 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6855978
21 October 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6838964
21 August 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6803769
28 March 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6651126
1 November 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6572456
13 November 2017
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6302474
2 September 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6258474
16 February 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6089235
2 November 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6033913
19 February 2016
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5818230
2 January 2016
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5789836
2 January 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5801709
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 February 2025
Resolved
A vessel must comply with the applicable requirements for any radio installation. Vessel did not have valid FCC Bridge to Bridge and Safety Radiotelephony certificates.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2025
Resolved 7 April 2025
Resolution: Received copy of documentation satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2022
Resolved
Wire on stbd engine found to have unprotected dead end. removed or cap dead end.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 January 2022
Resolution: wire removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2022
Resolved
Face plate on fish hold switch in engine room found to be fractured. Replace face plate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 25 January 2022
Resolution: Replaced face plate
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 January 2022
Resolved
Both main propulsion engines found to be missing machinery guards. Install Guards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 25 February 2022
Resolution: Both machinery guards installed. DEM
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 January 2022
Resolved
EPIRB tests found to be missing from logbook. EPIRB should be tested and logged monthly
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 January 2022
Resolution: Logged EPIRB Test
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 February 2021
Resolved
Repair/ make operable hinges on galley hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 1 March 2021
Resolution: Vessel rep emailed picture of corrected def.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 February 2021
Resolved
Prove proper operation of machinery space high water alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 1 March 2021
Resolution: Vessel rep emailed picture of corrected def.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 18 February 2021
Resolved
Secure galley appliances for sea.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 5 March 2021
Resolution: Received pictures and statement from Master.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 February 2021
Resolved
Install spanner wrench (x 2) - one at each hose station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 19 February 2021
Resolution: Vessel rep emailed pictures.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 November 2019
Resolved
Provide DSC VHF radio with GPS input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 3 December 2019
Resolution: Received photo with lat/long displayed on screen of DSC radio.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 November 2019
Resolved
Replace flexible hose on stbd aft void bilge line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 15 November 2019
Resolution: Recieved photo of new hose installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 November 2019
Resolved
Provide 02 bilge pumps with coupling guards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 3 December 2019
Resolution: Received photo of coupling guards re-installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2019
Resolved
Provide junction boxes for dead-ended cables in engine compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 2 December 2019
Resolution: Junction boxes were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2019
Resolved
Provide chafe protection for 02 cables in overhead of engine compartment aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 21 November 2019
Resolution: Recieved photo of completion.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 November 2019
Resolved
Make permanent repairs to 03 areas of epoxied bilge piping found in galley void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 21 November 2019
Resolution: Epoxied areas were repaired with bolt on pipe couplings.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 November 2019
Resolved
Seal or plug opening in the top of the sewage tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 21 November 2019
Resolution: Recieved photo of completion.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 14 November 2019
Resolved
Permanently secure step bracket in forward void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 2 December 2019
Resolution: The bracket was re-welded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 November 2019
Resolved
Replace 02 holed fire hoses and 01 non-approved nozzle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 21 November 2019
Resolution: Received photo of new hoses.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 March 2019
Resolved
Provide buoyant line for 01 lifefloat upper port side bottom float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 28 March 2019
Resolution: New line installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 March 2019
Resolved
Provide spacers for all life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 28 March 2019
Resolution: Spacers provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 March 2019
Resolved
Make anchor light operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 28 March 2019
Resolution: New bulb installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 March 2019
Resolved
Provide operational Class B AIS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 28 March 2019
Resolution: Operational AIS installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2019
Resolved
Place covers on J-boxes in starboard head access to helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 12 April 2019
Resolution: J-boxes installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2019
Resolved
Cap or remove dead end wire in starboard head access to helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 12 April 2019
Resolution: Dead end wires capped.
Construction/Loadline › Structures › Ventilators
Issued 13 November 2017
Resolved
Repair/replace damaged windows.
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 3 January 2018
Resolution: New window installed.
Fire Fighting › Fire Pumps › Pressure
Issued 13 November 2017
Resolved
Repair/replace fire pump gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 3 January 2018
Resolution: New gauge installed on fire main.