Records from 1985 to 2026. Most recent: inspection, 14 May 2026.
Inspection history · 86
14 May 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8373291
3 March 2026
Inclining Experiment · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8323517
8 January 2026
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8294109
13 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8134873
7 November 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8031812
16 May 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7913421
7 March 2023
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7642922
9 December 2022
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7621257
1 December 2022
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7627746
24 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7418075
13 January 2022
Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7380168
16 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7158649
4 November 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7089595
18 March 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928483
21 October 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6839004
28 February 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6634424
8 November 2018
Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6565872
5 February 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6349991
7 March 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6099920
8 November 2016
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6037409
15 March 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5833993
10 June 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4339882
13 February 2012
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4243540
6 December 2011
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4203126
18 January 2011
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3926877
17 February 2010
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3671803
17 February 2009
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3398978
15 December 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3378510
7 May 2008
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3200826
6 May 2008
Spot Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3200807
22 February 2008
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3140506
4 June 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2954227
5 March 2007
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2877029
22 February 2007
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2870910
22 February 2006
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2586705
30 July 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2449377
13 June 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2390185
14 March 2005
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2295266
20 December 2004
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2303825
19 February 2004
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2009386
5 December 2003
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1946207
31 July 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1867702
11 June 2003
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1814991
24 February 2003
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1748607
4 March 2002
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1490788
26 December 2001
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473937
5 December 2001
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1389518
26 February 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1466750
20 March 2000
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1047669
24 February 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1369551
16 February 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 169666
23 November 1999
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1444245
11 March 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372538
10 March 1998
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364609
16 December 1997
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409813
26 February 1997
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1424343
25 February 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 184764
28 January 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 211981
26 February 1996
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1380421
8 December 1995
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1407586
1 March 1995
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417738
1 March 1994
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373989
16 February 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 216554
17 December 1993
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1439457
25 March 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1149036
2 March 1993
COI Inspection · Drydock Extension
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1149992
21 February 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 66461
4 March 1992
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1008520
16 December 1991
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 946854
14 March 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 920061
6 March 1991
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 902381
6 March 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1243303
4 March 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 928721
6 March 1990
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 913249
9 March 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 890947
3 March 1989
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 887658
8 December 1988
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1207476
10 November 1988
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1203011
2 September 1988
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1040724
3 March 1988
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1336378
12 March 1987
Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1012640
3 March 1987
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1320182
12 March 1986
COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1300088
10 October 1985
Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 986324
15 March 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1287008
8 January 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 977025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found 2 open circuits slots on starboard side breaker panel under the main helm. Properly encase the breaker panel and notify local OCMI
46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2026
Resolution: POC provided images of blank breakers (not in use). All SAT
01 - Certificates & Documentation › 011 - Ships Certificates › Operational Limitations for Passenger ships
Issued 14 May 2026
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel's hand orange smoke distress signals are expired. Vessel has six red hand flare distress signals and is required to have 6 hand orange smoke signals in order to meet the regulation. Vessel restricted to a Lakes/Bays/Sounds route or 30 min runs.
46CFR180.68
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: POC provided images of new hand flares. All SAT
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2026
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. First aid kit is incomplete. Provide USCG-approved kit or a kit that complies with the list in 46 CFR 160.041.
46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2026
Resolution: POC provided images of updated first aid. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 May 2026
Resolved
On a vessel of not more that 65 feet in length carrying more than 49 passengers, and on a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure on not less than 60 PSI at the pump outlet. The pump outlet must be fitted with a pressure gauge.
46CFR181.300(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 May 2026
Resolution: POC provided images of new fire PMP guage. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 January 2026
Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard prior to being placed into service. The stability letter prescribes the vessel’s approved conditions of operation.
The vessel has completed a repower, and stability is currently under review by MSC. Pending final approval of the stability review, the vessel is authorized to operate with a passenger count limited to no more than 60 persons.
46CFR170.120
Action required: 705 - Other - as specified
Resolved 20 March 2026
Resolution: Completed incline test and received approved stability letter from MSC
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 January 2026
Resolved
Upon completion of drydock, the vessel is to schedule an appointment with a Coast Guard Marine Inspector for sea trails and testing of new propulsion engines, prior to taking on passengers.
46CFR176.610
Action required: 705 - Other - as specified
Resolved 3 February 2026
Resolution: Completed sea trails and QFA of new propulsion controls. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2025
Resolved
Multiple life rings on the vessel were found with improper retro tape. Provide all life rings with proper retro tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: Retro tape renewed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 May 2025
Resolved
Vessel's FCC safety cert and bridge to bridge cert were found to be expired. Provide vessel with valid FCC certs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: New cert issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2025
Resolved
Vessel's fire hoses were found with plastic fire nozzles, provide hoses with approved brass/bronze nozzles.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: New nozzles installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 May 2025
Resolved
Vessel's life floats were tethered to each other with 2 ft of line. Provide lines long enough to prevent floats from stacking up.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: Lines correct.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 March 2023
Resolved
Vessel’s generator’s was discovered to have been
replaced recently. Provide proof of overcurrent
protection for both generators. Overcurrent protection
cannot exceed 115% of the generator full load rating
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 7 April 2023
Resolution: Installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2023
Resolved
Both main engine exhaust piping was found to have
missing lagging prior to salt water introduction,
provide adequate lagging / insulation
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2023
Resolved 7 April 2023
Resolution: Installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2023
Resolved
The port generator exhaust piping was found to be
unsupported and hald in place with zip-ties, provide
permanent support mounting
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 7 April 2024
Resolution: Installed support
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2023
Resolved
Both main engine’s flexible non-metallic fuel hoses
were found to chaffed areas, provide all fuel hose on
both engines with adequate chafe protection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 7 April 2023
Resolution: Installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 March 2023
Resolved
The port main engine racor fuel filter was found to be
slowly leaking, make repairs and stop the leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 7 April 2023
Resolution: Tightened
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 March 2023
Resolved
Vessel has not installed newly required interconnected
fire detection that was due to be installed 27DEC22.
Route restricted to Limited Coastwise (20nm from SD Bay)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2023
Resolved 7 April 2023
Resolution: Installed, Tested, SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 March 2023
Resolved
02 of the 03 life rings were faded and white in color.
Replace or re-coat to international orange.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2023
Resolved 21 March 2023
Resolution: Replaced
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 24 March 2022
Resolved
Wrap all engine exhausts with proper lagging up to water cooling injection point.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 10 May 2022
Resolution: Exhaust wrapped with appropriate lagging, picture received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2022
Resolved
Replace 04 condemned Type I child life jackets. Passengers under 90 lbs limited to 10.
Action required: 705 - Other - as specified
Due 7 April 2022
Resolved 7 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2022
Resolved
Mark fuel day tank reach rod with "Emergency Fuel Shutoff" of letters at least 1" high.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 10 May 2022
Resolution: Fuel tanks marked, picture received.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 March 2022
Resolved
Replace expired eye wash in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 10 May 2022
Resolution: Eye wash replaced, receipt received.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 March 2022
Resolved
Replace 01 non-operational life float floating light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 10 May 2022
Resolution: Light replaced, picture received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 January 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. Operational tests of generator required following re-power. Schedule operational tests with Sector San [name withheld].
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 November 2024
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 March 2021
Resolved
All vessel operators must log their drills and make available for review by USCG. Deficiency was corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 16 March 2021
Resolved 16 March 2021
Resolution: Corrected on the spot. [name withheld]
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 March 2021
Resolved
Must provide FCC Ship Radio Safety and Bridge to Bridge Certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 1 June 2021
Resolution: Verified through FCC webpage on vessel's enrollment. [name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2019
Resolved 15 April 2019
Electrical › Electric Supply System (service) › Cable
Issued 15 March 2016
Resolved
Remove all existing welding cable on both mde's and SSDG and replace with approved type, prior to next drydock NOV 2016.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 November 2016
Resolution: Approved type of wire for both MDE's and SSDG were provided.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 March 2016
Resolved
Provide 04 Child and 07 Adult lifejackets.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 10 May 2016
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 March 2016
Resolved
Install UL approved smoke detector in galley.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 10 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2016
Resolved
Remove extension cords and hard wire both freezers in galley.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 10 May 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 March 2016
Resolved
Install brackets on both freezers in the galley.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 10 May 2016
Lifesaving › Lifebuoys › Serviceable
Issued 15 March 2016
Resolved
Install detachable clip on 01 Life Ring.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 10 May 2016
Engineering › Bilge Water Management System › Not Installed
Issued 15 March 2016
Resolved
Provide secondary source of power for bilge pumping system and properly plumb all bilge piping.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 10 May 2016
Lifesaving › Hand Flares › Expired
Issued 22 February 2012
Resolved
Provide new flares: 6 red hand flares and 6 orange smoke.
Action required: 705 - Other - as specified
Due 24 February 2012
Resolved 24 February 2012
Resolution: Received fax receipt of purchase.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 February 2012
Resolved
Seal light fixture in laz.
Action required: 705 - Other - as specified
Due 24 February 2012
Resolved 24 February 2012
Resolution: Received verbal confirmation from vessel owner that fixture was sealed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 February 2012
Resolved
Install smoke detector in galley IAW CID Note, must be UL approved.
Action required: 705 - Other - as specified
Due 24 February 2012
Resolved 24 February 2012
Resolution: Received receipt for smoke detector.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 February 2010
Resolved
Renew retro-reflective tape for ring buoy on bow.
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 5 March 2010
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 February 2010
Resolved
Make (4) lifefloat waterlights on top of pilot house float free.
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 5 March 2010
Fire Fighting › Means of Escape › Escape Route Signs
Issued 17 February 2010
Resolved
Properly mark emergency exit from E/R to main deck.
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 5 March 2010
Fire Fighting › Fire Hydrants › Condition
Issued 17 February 2010
Resolved
Repair leaking port side fire hydrant.
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 5 March 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 February 2010
Resolved
Rejected (18) adult Type-1 PFDs. Provide an additional (18) adult Type-1 PFDs.
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 5 March 2010
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 February 2009
Resolved
8 Adult Life Jackets out of servicable condition. Remove and replace 8 Adult life jackets IAW 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 24 February 2009
Resolved 17 February 2009
Resolution: O/OP perchased 8 new Adult Life Jackets IAW 46 CFR 180.71
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 May 2008
Resolved
Marine Sanitation Valves were in open position, allowing direct flow from toilets to Mission Bay, CA.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 17 February 2009
Resolution: Inspected Marine Sanitation Valve, Lock installed to prevent opening of valve, discussed boat policy with O/OP.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 February 2008
Resolved
Remark vessel name on ring buoy on bow.
Action required: 705 - Other - as specified
Due 22 March 2008
Resolved 27 February 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 February 2008
Resolved
Remark/label number of adult PFDs stored in port side PFD stowage containers located under seats in galley space.
Action required: 705 - Other - as specified
Due 22 March 2008
Resolved 27 February 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 February 2008
Resolved
Provide current US Coast Pilot and Light List, or extracts.
Action required: 705 - Other - as specified
Due 22 March 2008
Resolved 27 February 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 March 2007
Resolved
Rejected (102) adult & (8) child PFDs (kapok).
Action required: 705 - Other - as specified
Resolved 5 March 2007
Resolution: Owner purchased new adult PFDs ($3K worth) and replaced on the spot. Child PFDs replaced with extras in storage.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 March 2007
Resolved
Proof of current drug test enrollment for crewmembers required. Current drug test ltr expired 12/06. (No Sail)
Action required: 705 - Other - as specified
Resolved 5 March 2007
Resolution: Verified current enrollment.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 7 March 2006
Resolved
Install remote fuel shut-off valve on main diesel fuel tank that complies with 46CFR182.455(b)(4), and prove section of flexible hose installed between the fuel tank and 1st valve meets SAE J-1942 for fuel service.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 22 February 2007
Resolution: Installed new fuel shut-off valve; tested sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 February 2006
Resolved
Replace line on ring buoy
Due 6 March 2006
Resolved 6 March 2006
Lifesaving › Buoyant Apparatus › Painter
Issued 22 February 2006
Resolved
Replace line connecting lifefloats together to painter.
Due 6 March 2006
Resolved 6 March 2006
Fire Fighting › Grease Extraction Hood › General
Issued 22 February 2006
Resolved
Clean galley hood ducting.
Due 6 March 2006
Resolved 6 March 2006
Fire Fighting › Grease Extraction Hood › General
Issued 22 February 2006
Resolved
Install grease filter for galley hood.
Due 6 March 2006
Resolved 6 March 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 February 2006
Resolved
Install cover on bilge pump electrical box.
Due 6 March 2006
Resolved 6 March 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 February 2006
Resolved
Install blank in open bay slot, breaker panel in E/R.
Due 6 March 2006
Resolved 6 March 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 February 2006
Resolved
Replace expired meds in 1st aid kit.
Due 6 March 2006
Resolved 6 March 2006
Lifesaving › Lifebuoys › Serviceable
Issued 14 March 2005
Resolved
Lifebuoy needs to be replaced due to wear (faded, deteriorating). Three (3) required, only two in sat condition.
Due 31 March 2005
Resolved 17 March 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 March 2005
Resolved
Current light list pub is outdated (1997 Ed.) Updated version is required.
Condition: Improper/Lack of Maintenance
Due 31 March 2005
Resolved 17 March 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 March 2005
Resolved
U.S. Coast Pilot pub is outdated (1997 Ed.) Updated version is required.
Condition: Improper/Lack of Maintenance
Due 31 March 2005
Resolved 17 March 2005
Navigation › Piloting/Steering › Marine Charts
Issued 14 March 2005
Resolved
Vsl's navigational chart is outdated. Updated version is required.
Condition: Improper/Lack of Maintenance
Due 31 March 2005
Resolved 17 March 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 March 2005
Resolved
Vsl has tide tables, but is missing the tidal current tables.
Condition: Improper/Lack of Maintenance
Due 31 March 2005
Resolved 17 March 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 4 March 2005
Resolved
Vessel required to be marked IAW 46 CFR 185.602.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2005
Resolved 4 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 February 2003
Resolved
Fire extinguisher brackets need to be replaced in the port side galley space and both portable extinguishers in the Engine Room. IAW 46 CFR 181.500 (a). LEGACY COMPONENT DESC: Mounting Bracket
Due 24 February 2003
Resolved 27 February 2003
Lifesaving › Embarkation Appliances/Stations
Issued 24 February 2003
Resolved
Rescue ladder needs to be replaced with a more stable ladder, to the satisfaction of the CG Inspector. IAW 46 CFR LEGACY COMPONENT DESC: Accessability
Due 24 February 2003
Resolved 24 February 2003
Lifesaving › Buoyant Apparatus
Issued 4 March 2002
Resolved
Lifering light needs to be attached to Life Ring LEGACY COMPONENT DESC: Lifering light
Condition: Improper Installation
Due 12 March 2002
Resolved 4 March 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 March 2002
Resolved
[name withheld] compartments with proper count LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 21 March 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 March 2002
Resolved
Replace Reflective tape on PFDs as necesarry LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 21 March 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 March 2002
Resolved
Label PFDs with vessel's name LEGACY COMPONENT DESC: Marking
Due 11 March 2002
Resolved 21 March 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 4 March 2002
Resolved
Clean galley vent for exhaust
Due 11 March 2002
Resolved 21 March 2002
Engineering › Freshwater System (air cooling)
Issued 4 March 2002
Resolved
Replace starboard pedro on exhaust cooling water
Due 11 March 2002
Resolved 21 March 2002
Construction/Loadline
Issued 5 December 2001
Resolved
REPLACE PIPING IN KIND OR REPAIR SALT WATER LEAK ON PIPING IN FWD PORT CORNER OF ENGINE ROOM.
Condition: Unknown
Due 10 December 2001
Resolved 7 December 2001
Engineering
Issued 5 December 2001
Resolved
INSTALL HOSE CLAMPS ON AUX PUMP INBOARD OF PORT ENGINE.
Condition: Unknown
Due 10 December 2001
Resolved 7 December 2001
Construction/Loadline
Issued 5 December 2001
Resolved
SEAL BLKHD PENETRATIONS IN LAZARETTE.
Condition: Unknown
Due 10 December 2001
Resolved 7 December 2001
Electrical
Issued 5 December 2001
Resolved
USE OR REMOVE DEAD ENDED WIRES TO OLD WATER HEATER OR TERMINATE IN A JUNCTION BOX.
Condition: Unknown
Due 10 December 2001
Resolved 7 December 2001
Engineering
Issued 5 December 2001
Resolved
REPLACE PIPING IN KIND IN AFT PORT CORNER OF ENGINE ROOM.
Condition: Unknown
Due 10 December 2001
Resolved 7 December 2001
Lifesaving
Issued 24 February 2000
Resolved
a. Prove hydro-release date for EPIRB_x001C_ b. Test EPIRB and log tests.
Condition: Unknown
Due 24 February 2000
Resolved 20 March 2000
Navigation
Issued 24 February 2000
Resolved
Prove properation of Single Side band radio. 47CFR80.903
Condition: Unknown
Due 24 March 2000
Resolved 20 March 2000
Navigation
Issued 24 February 2000
Resolved
Prove proper operation of compass light IAW 46CFR184.402(c).
Condition: Unknown
Due 24 March 2000
Resolved 20 March 2000
Fire Fighting
Issued 11 March 1999
Resolved
Fire Pump not fitted with pressure Gauge as per 46 CFR 181.300
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999
Resolved
Missing Blank Circuit Breaker Covers in port Engine Room Panel, IAW 46CFR181.300.
Condition: Unknown
Due 11 April 1999
Resolved 16 March 1999
Lifesaving
Issued 1 March 1995
Resolved
REPAIR LINES ON THREE LIFE RINGS.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Construction/Loadline
Issued 1 March 1995
Resolved
REMOVE ALL STEEL FITTINGS FROM ALUMINUM BILGE PIPING SYSTEM AND REPAIR_x001C_ PIPING AS REQUIRED._x001C_
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Documentation
Issued 2 March 1993
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION WITH PROPER SERVICE ENDORSEMENT.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Engineering
Issued 4 March 1991
Resolved
REPAIR INOPERABLE TACHOMETER FOR THE STARBOARD MAIN PROPULSION ENGINE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Construction/Loadline
Issued 4 March 1991
Resolved
PROVIDE CAPTURE CHAIN FOR THE DECK HATCH COVER OF THE FORWARD COMPARTMENT. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Navigation
Issued 4 March 1991
Resolved
PROVIDE ONE ADDITIONAL BLACK BALL DAY SHAPE AND TWO RED LIGHTS. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Navigation
Issued 3 March 1989
Resolved
PROVIDE CURRENT LIGHT LIST ON BOARD.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Documentation
Issued 3 March 1989
Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION ON BOARD PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Navigation
Issued 3 March 1989
Resolved
PROVIDE COPY OF INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Navigation
Issued 3 March 1988
Resolved
PROVIDE MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 12 March 1987
Resolved
PUT STENCIL AT OVERBOARD DISCHARGE VALVE FROM SEWAGE TANK STATING "VALVE NOT TO BE OPENED WITHIN 3 MILES OF SHORE."
Condition: Unknown
Due 12 March 1987
Resolved 12 March 1987
Construction/Loadline
Issued 12 March 1987
Resolved
PLUG 2 OPEN PENETRATIONS IN FORWARD BULKHEAD IN LAZARETTE.
Condition: Unknown
Due 12 March 1987
Resolved 12 March 1987
Navigation
Issued 3 March 1987
Resolved
PAINT SCREENS FOR SIDE RUNNING LIGHTS MATT BLACK.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Engineering
Issued 3 March 1987
Resolved
MAKE OPERABLE THE OIL PRESSURE ALARM LIGHT IN THE PILOT HOUSE.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Lifesaving
Issued 3 March 1987
Resolved
PROVIDE 2 PADDLES AT LEAST 4 FT LONG FOR EACH LIFE FLOAT.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Lifesaving
Issued 12 March 1986
Resolved
RENEW TENDING LINE ON RINGBUOY
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986