NATIVE SUN

NATIVE SUN is a 1983 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 29 deficiencies and 3 casualty investigations between 2006 and 2015.

Records from 2006 to 2026. Most recent: inspection, 28 April 2026.

Built
1983
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL9566
228966
Flag
UNITED STATES
Maury page id
psix-228966

Documentation record

Registered dimensions (L × B × D)73.3 ft × 24.6 ft × 5.7 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBETTY-O ENTERPRISES INC · VENICE, CA, UNITED STATES · built 1983
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
44 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

28 April 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8290458
27 January 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8057298
18 March 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7882649
8 February 2024 Plan Review "T" Boat · Re-Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7833446
13 March 2023 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7634213
24 January 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7626607
30 December 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7595690
14 December 2022 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613918
30 November 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7580003
16 June 2022 In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485395
17 February 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7397842
24 February 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7145754
19 February 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7158083
25 February 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6915664
21 February 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6624794
14 January 2019 Plan Review "T" Boat · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6607463
30 November 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6300504
29 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314625
13 March 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6103691
7 February 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6072057
2 February 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6072051
10 March 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5817664

Deficiency record · 29

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 April 2026 Resolved
At initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appendages: (1) examine all accessible parts of watertight bulkheads. Marine inspector (MI) observed a 2 inch cutout amidships over the keel beam in a watertight bulkhead. Affect temporary repairs until scheduled dry dock. 46 CFR 176.25-5(a)(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2026
Resolved 7 August 2026
Resolution: MI attended vsl and confirmed repairs.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 April 2026 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. MI observed three openings in the watertight bulkheads in the engine room. 46 CFR 181.20-35
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 1 May 2026
Resolution: Operator sent videos of all the opening filled with foam in the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 28 April 2026 Resolved
All electrical installations shall be to the satisfaction of the officer in charge, marine inspection. MI observed a bonding wire on the steering gear was disconnected. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 1 May 2026
Resolution: Operator sent a picture showing the bonding wire reconnected.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 28 April 2026 Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. MI observed the vessel had an expired bridge-to-bridge certificate. 47 CFR 80.1005
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 18 May 2026
Resolution: Operator sent pictures of the new certificates once he recieved them.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 28 April 2026 Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. The technician conducting the inspection and providing the certification must not be the vessel's owner, operator, master, or employee or their affiliates. MI observed the radiotelephony certificate was expired. 47 CFR 80.59 (a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 18 May 2026
Resolution: Operator submitted new certificate once they recieved them.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 February 2024 Resolved
Fuel shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine. The shutoff valve at the tank shall be operable from outside the tank compartment. STBD fuel tank remote shutoff valve handle found wasted and nearly broken off; replace valve handle so that valve is operational from outside the space. OLD T- 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 8 February 2024
Resolution: New valve handle installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2024 Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filter for generator found missing flame shield bowl.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 4 March 2024
Resolution: bowl fitted to filter
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2024 Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. Valve for generator fuel filter was found to be of the plastic type and not suitable metallic type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 4 March 2024
Resolution: valve replace to metallic
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2024 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Multiple wire runs in E/R found supported with plastic supporting devices; replace with metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2024
Resolved 8 February 2024
Resolution: Electrical cable runs in E/R supported with metal clips.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 February 2024 Resolved
The number of penetrations in a watertight bulkhead (WTB) must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. WTB between tank space and galley space found with penetrations for wire runs that were not watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2024
Resolved 8 February 2024
Resolution: Penetrations in MWTB sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2024 Resolved
Vessels over 65 feet shall be provided with 2 fixed powered bilge pumps that are self priming, each driven by different sources of power, and must be permanently connected to the bilge main. Vessels is documented as 73ft and fitted with 02 electric pumps (1 bilge/1 fire)that are connected to the bilge main but they are driven off the same source of power (generator). Provide a written plan to the Officer in Charge, Marine Inspection (OCMI) to install a system that would be compliant with the regulations for bilge systems in passengers vessels. This plan must be approved by the OCMI prior to any installation or modification of the vessel. OLD T - 46 CFR 182.25-10(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2024
Resolved 13 May 2024
Resolution: Powered bilge pump installed and operationally tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 March 2023 Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018. MI identified 40 adult and 07 child life jackets had worn out retro reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2023
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 March 2023 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel had missing placard for maximum passenger capacity on the upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2020 Resolved
Existing vessels with a hull of fiberglass or wood shall have a galley hood that meets UL 710 and have a dry or wet chemical extinguishing system that meets NFPA 17 of NFPA 17A. 705c prior to use of griddle.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 March 2020
Resolved 8 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 February 2020 Resolved
Provide portable extinguisher for galley that meets 40-B:C UL rating. 705c prior to use of the griddle
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 March 2020
Resolved 27 February 2020
Resolution: A new 40 B:C extinguisher was placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2020 Resolved
Replace 13 Adult and 6 Child lifejackets with appropriate type I jackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2020
Resolved 25 February 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2020 Resolved
Replace Retro-reflective tape on 10 identified life jackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2020
Resolved 25 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 February 2020 Resolved
Vertical ladder leading to engine room was loose and allowed for the climber to teeter and possible fall backwards. Properly secure ladder for safety of access to E/R.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 February 2020
Resolved 25 February 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 February 2020 Resolved
Provide 2 additional orange smoke and 1 red hand flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2020
Resolved 25 February 2020
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 November 2017 Resolved
Provide 3 adult lifejackets. 3 of the adult lifejacket are not fit for service. The number of passengers is reduced by 3 until this item is corrected.
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 30 November 2017
Resolution: Corrected during inspection.
Construction/Loadline › Hull › Keel
Issued 2 February 2017 Resolved
Reseal keel cap.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 7 February 2017
Resolution: Corrected before vessel launched.
Engineering › Steering Gear System › Rudder
Issued 2 February 2017 Resolved
Repair starboard rudder.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 7 February 2017
Resolution: Corrected before vessel launched following drydock.
Engineering › Steering Gear System › Rudder
Issued 2 February 2017 Resolved
Replace 12 @ 4" strut bolts in lazarette.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 7 February 2017
Resolution: Replaced prior to vessel launching following drydock.
Electrical › Electric Generation Source (service) › Generator
Issued 2 February 2017 Resolved
Clean excessive oil from electrical generator windings.
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 10 February 2017
Resolution: Corrected during annual inspection.
Documentation › Logs/Records › Logbook (official)
Issued 10 March 2016 Resolved
Log passenger count during embarkation and disembarkation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 22 March 2016
Resolution: Passenger embarkation and disembarkation count is being logged.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 March 2016 Resolved
Provide EAP training to supervisor and crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 22 March 2016
Resolution: Provided proof of online training.
Engineering › Bilge Water Management System › Interface Detector
Issued 10 March 2016 Resolved
Provide High Level Alarm light for Fuel Room at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 22 March 2016
Resolution: Purchased appropriate replacement bulb.
Navigation › Piloting/Steering › Marine Charts
Issued 10 March 2016 Resolved
Provide appropriate charts for area of operation/route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 22 March 2016
Resolution: Purchased appropriate charts for area of operation.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 March 2016 Resolved
Remove and destroy 20 adult and 2 child lifejackets which were unservicable.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 10 March 2016
Resolution: Removed from vessel and destroyed. There were extra lifejackets, and did not replacing.

Casualty record · 3

25 March 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2640385
23 July 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2724329
9 August 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5222029
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.