PRINCE KUHIO

PRINCE KUHIO is a 1983 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in April 2026, along with 157 deficiencies — 1 with no resolution recorded — and 4 casualty investigations between 2004 and 2023.

Records from 2004 to 2026. Most recent: inspection, 30 April 2026.

Built
1983
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 April 2026
…with no type recorded3
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ3414
228971
Flag
UNITED STATES
Maury page id
psix-228971

Documentation record

Registered dimensions (L × B × D)77.2 ft × 24.1 ft × 8.7 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPATTERSON, LA, UNITED STATES · built 1983
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 June 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

30 April 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8358988
18 September 2025 Deficiency Check · Administrative Inspection · Internal Structural Exam · Damage Survey · Drydock Exam · Vessel Attendance
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8237037
19 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8078919
11 March 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8092737
31 January 2025 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8073015
5 April 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879959
22 February 2024 Plan Review "T" Boat
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7889067
26 October 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7794146
22 August 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7774662
3 April 2023 Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7645060
29 March 2023 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7659891
4 February 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7664229
2 November 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7588347
2 November 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7588503
3 January 2022 Deficiency Check · Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7373989
26 October 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7340434
15 September 2021 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7313125
9 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7094035
5 December 2019 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6867606
22 October 2019 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6840083
2 April 2019 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6654545
3 April 2018 Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6384355
24 October 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6298591
24 February 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6093787
10 January 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6068288
12 January 2016 Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5795592

Deficiency record · 157

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2025 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Sector Honolulu received report that subject vessel has one inoperable generator, damage to props, and is pumping sewage directly overboard. Vessel is prohibited from movement until an inspection is completed by marine inspectors to determine suitability for service. 46 CFR 176.840
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 October 2025
Resolution: Code 60 changed to 701 to allow vessel to proceed to drydocking after successful test of propulsion systems. See def #17.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2025 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structure examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel unintentionally grounded, damage to hull and propulsion suspected. Vessel is prohibited from carrying passengers and is authorized to make a one-time transit directly to Phoenician shipyard for emergency drydock inspection. 46 CFR 176.600(d)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 October 2025
Resolution: Vessel transited to Phoenician Shipyard; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 March 2025 Resolved
The minimum capacity of a the fire pump shall be 50 gallons per minute of a pressure of not less than 60 pounds per square inch at the pump outlet. Unable to provide adequate proof of pressure due to wasted and blown fire main pipe. Replace wasted section and conduct fire main test to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Vessel replaced wasted section of fire main piping. Pressure tested satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 19 March 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules... White masthead light and anchor light do not illuminate when energized. Restore to operational status to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 March 2025
Resolution: Vessel repaired extinguished anchor light.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 March 2025 Resolved
A vessel on an Oceans, Coastwise, Limited Coastwise, or Great Lakes route must carry - Six hand red flare distress signals... 04 red flare signals onboard found to be expired. Replace with approved red flares to the satisfaction of the attending marine inspector. Until resolved, vessel is limited to operation to Lakes, Bays, and Sounds.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2025
Resolved 27 March 2025
Resolution: Vessel purchased new flares to meet requirements.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 March 2025 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. 01 large pit measuring 5/16 in in depth located in the port transom within the lazarette. Submit a repair proposal to the satisfaction of Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2025
Resolved 27 March 2025
Resolution: Will be addressed at drydock. See special note.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 March 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. 02 life ring buoys on board vessel have deteriorated Type II retroreflective material. Replace the retroreflective material on the main deck port life ring and upper deck light ring to return both rings to compliance to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2025
Resolution: Renewed retro reflective tape on life buoys.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 March 2025 Resolved
Electrical equipment must be installed to protect from electrical hazards. Gangway winch wiring found with splices. Replace wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2025
Resolution: Vessel replaced wiring for gangway winch.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 March 2025 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Areas in the overhead of the lazarette found with several pits, exhaust flange in lazarette was found with rust and corrosion, cooling water pipe for exhaust in way of previously mentioned flange was found with weeping from welds and swim platform found with separation of wooden planks from main structural support. Address all areas by completion of next drydock.
Action required: 705 - Other - as specified
Resolved 27 March 2025
Resolution: To be repaired at drydock. See special note.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 March 2025 Resolved
Fire hose shall be 1 1/2 inches in diameter and 50ft in length and be lined commercial fire hose that conforms to UL 19. Excessive leaking was found from both fire hoses. Replace hoses with UL 19 conforming hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2025
Resolution: Vessel replaced fire hoses with UL 19 rated hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2024 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Approved Coast Guard Marine Safety Center (MSC) QFA/DVTPs for the vessel’s ZF MICROCOMMANDER processor propulsion engine control system Throttle feedback potentiometer failure test failed, two manufacturer procedures were not submitted for review, and approved DVTPs require revision. 1) Provide ZF's determination of the witnessed result for the throttle feedback potentiometer failure; 2) Add the two missing manufacturer procedures to DVTPs; 3)Submit revised DVTPs to MSC for approval; 4)Conduct a retest of the throttle feedback potentiometer failure. Number 1,2,and 3 are to the satisfaction of the attending marine inspector. Number 4 is in the presence of the attending marine inspector. 46 CFR 176.700(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 11 December 2024
Resolution: Received email from vessel contractor, Greg with MSC propulsion control QFA and DVTP approval letter serial number E2-2404272; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Center engine port cylinder bank turbo exhaust leak. Repair and operate engine under load in the presence of the attending marine inspector by August 2, 2024. 46 CFR 176.830(a)
Action required: 705 - Other - as specified
Due 2 August 2024
Resolved 16 August 2024
Resolution: Attended vessel and witnessed the operation of the center engine with no exhaust leak from the port turbo. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Center engine port side turbo oil supply line fitting weeps oil. Repair and operate the engine under load in the presence of the attending marine inspector by August 2, 2024. 46 CFR 176.830(a)
Action required: 705 - Other - as specified
Due 2 August 2024
Resolved 16 August 2024
Resolution: Attended vessel and witnessed the operation of the center engine with no oil leaking from the port turbo oil supply line fitting; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Both the port engine turbos oil supply line fitting weeps oil. Repair and operate the engine under load in the presence of the attending marine inspector by August 2, 2024. 46 CFR 176.830(a)
Action required: 705 - Other - as specified
Due 2 August 2024
Resolved 2 August 2024
Resolution: Attended vessel and observed no oil leaking and/or weeping from both the port engine turbos oil supply line fittings while engines were running; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Stbd engine exhaust lagging on both exhaust pipes are oil saturate and identify and repair the source of the stbd engine manifolds to exhaust piping oil leak that is causing the lagging to become saturated with oil. Repair to the satisfaction of the attending marine inspector by August 2, 2024. 46 CFR 176.830(a)
Action required: 705 - Other - as specified
Due 2 August 2024
Resolved 9 August 2024
Resolution: Operator renewed all exhaust lagging and replaced old components.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 July 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room bilge has oil soaked diapers, excessive oil/water in bilge, and accumulation of oil on the machinery and their foundations. Remove oil soaked diapers from bilge, clean bilge of the excessive oil and water, and wipe running oil off the machinery and foundations to the satisfaction of the attending marine inspector by August 2, 2024. 46 CFR 176.830(b)
Action required: 705 - Other - as specified
Due 2 August 2024
Resolved 2 August 2024
Resolution: Attended vessel and observed the engine room bilge clean with some water with an oil sheen and new oil sorbent diapers; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2024 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Approved Coast Guard Marine Safety Center (MSC) QFA/DVTPs for the vessel’s ZF MICROCOMMANDER processor propulsion engine control system test failed and two manufacturer procedures were not submitted for review. 1) Repair faulty alarms and failed stbd bridge wing throttle head; and 2) Conduct pretesting of approved DVTPs and missing DVTPs prior to requesting Coast Guard MI attendance to witness testing. 46 CFR 176.700(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2024
Resolution: Attended vessel and witnessed all DVTPs. Three of the four test were satisfactory. Cleared and issued new deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 April 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The #1 generator raw water sea strainer valve was seized and could not be operated. Install new valve prior to carriage of passengers. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2024
Resolution: Crew replaced Raw water vavle. Tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The port and starboard air receiver cross connect pipe was severely wasted. Remove pipe and cap isolation valves at each air receiver prior to carriage of passengers. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2024
Resolution: Crew removed wasted pipe and capped each isolation valve at the air receivers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2024 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Stern, mast and anchor lights were inoperable. Provide navigation lights that are in compliance with the Navigation Rules. Vessel is restricted to daylight operation. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 5 April 2024
Resolution: Crew replaced burnt out bulbs in each inoperable navigation light. Tested Satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 April 2024 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel has eight red hand flare distress signals and is required to have 4 hand orange smoke or red hand flare signals in order to meet the regulation. Vessel restricted to a Lakes/Bays/Sounds route or 30 min voyages. 46 CFR 180.68
Action required: 705 - Other - as specified
Resolved 5 April 2024
Resolution: Crew obtained the correct amount of flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 April 2024 Resolved
(a) Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency; (b) The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Vessel personnel installed an electric stop solenoid for the center engine without submitting plans. Submit the following to the attending Marine Inspector for review and approval: 1) Elementary one line diagram of power system; 2) Voltage drop calculation; and 3) Solenoid manufacturer data. Once the alteration proposal is approved by the attending Marine Inspector, complete the installation and test in the presence of the attending Marine Inspector. To be completed by August 10, 2024. Until the deficiency is resolved, the center engine is only to be operated in an emergency or when determined necessary by the master to ensure safe navigation of the vessel. 46 CFR 176.700(a)(b)
Action required: 705 - Other - as specified
Due 10 August 2024
Resolved 31 January 2025
Resolution: Electric stop solenoid removed and correct pneumatic stop solenoid installled. The center main engine was started and stopped from the navigation bridge twice and both times the engine stop solenoid shut the engine down and automatically reset. All sat.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 21 December 2023 No resolution recorded
Vessels shall be provided with toilets and wash basins in accordance with Table 177.30-5(a) except that vessels operating on short runs of approximately 30 minutes or less need not be fitted with toilets or wash basins. All toilets and wash basins provided shall be fitted with adequate plumbing. Vessel's Type III sewage holding tank is wasted and is not permitted to retain sewage. Submit a Type III sewage holding tank repair/replacement proposal for approval to the attending Marine Inspector. Once the repair/replacement proposal is approved by the attending Marine Inspector, complete the repair/replacement of the Type III sewage holding tank to the satisfaction of the attending Marine Inspector. 46 CFR 177.30-5 (a)(b) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2024 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 October 2023 Resolved
At each inspection of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: Inspection and operation of through hull fittings and sea valves. Make all sea valves within 6 inches of the waterline and below available for inspection. 46 CFR 176.802(a)(2)
Action required: 705 - Other - as specified
Resolved 7 November 2023
Resolution: Attended vessel to witness sewage overboard discharge valve fully closing; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2023 Resolved
During the examination all accessible parts of the vessels underwater body and all through hull fittings including the propellers, shafts, bearings shall be made available for examination. Remove bottom paint and make hull available for inspection. 46 CFR 176.610 (a)
Action required: 705 - Other - as specified
Resolved 30 October 2023
Resolution: Attended vessel to inspect the underwater body after coating removal due to suspected issues with the base metal; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 October 2023 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Three soft patches were found on fixed bilge piping in galley. Piping found to have holes in areas that were covered by soft patch. Replace identified section of bilge piping and conduct pressure test in presence of Marine Inspector. 46 CFR 177.300
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 November 2023
Resolution: The patched section of piping was replaced to the satisfaction of attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Raw water intake on port generator is wasted and needs to be replaced. Raw water pipe on starboard generator had salt residue possibly indicating a hole in pipe. Clean area and demonstrate proper operation. 46 CFR 183.200(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 November 2023
Resolution: Raw water piping found sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Generator screens on both generators found overly dirty. Clean screens. 46 CFR 183.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 November 2023
Resolution: Screens adequately cleaned on both generators.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 October 2023 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Four areas on starboard side overhead of engine room found with dripping water leaking down from male and female head located above. Provide repair proposal and make repairs to satisfaction of a Marine Inspector. 46 CFR 177.300(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 November 2023
Resolution: All holes were sealed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 October 2023 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Ceiling tiles found with water damage on starboard side of main salon. Remove damaged panels and make area available for inspection. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 7 November 2023
Resolution: Attended vessel to witness water test of the upper deck sink drain pipe base metal repair pin hole leak; all sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 26 October 2023 Resolved
An internal structural examination consists of a complete examination of the vessel's voids and ballast, cargo, and fuel oil tanks. De-water CO2 room and make available for inspection. 46 CFR 176.610(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 December 2023
Resolution: Vessel repaired with a satisfactory insert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2023 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Provide to the Coast Guard Marine Safety Center (MSC) - 1) A QFA of the vessel’s ZF propulsion engine control system (throttle) system limited to the loss of power to the control system. (2) A propulsion control drawing with an installation/operational test protocol. This test protocol is an abridged document to show compliance with 46 CFR.184.620. Upon MSC approval,the test must be witnessed by the attending MI. 46 CFR 176.700(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 25 July 2024
Resolution: The test procedures were reviewed and approved by MSC. DVTP testing witnessed and failed. Cleared this CG-835V and isued one for the failed DVTPs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2023 Resolved
Each circuit breaker must meet UL 489 or other standard specified by the Commandant, and be of the manually reset type designed for: (1) Inverse time delay; (2) Instantaneous short circuit protection; and (3) Switching duty if the breaker is used as a switch. New ZF MICROCOMMANDER processor circuit breakers are 10 amp UL 1077. Replace with 10 amp UL 489 circuit breakers to the satisfaction of the attending MI. 46 CFR 183.380(m)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 5 February 2024
Resolution: Received photograph from vessel owner of the new Blue Sea Systems 7441 10A Flat Rocker UL-489 Circuit Breaker installed; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Provide from the manufacturer or manufacturer's authorized representative a attestation letter stating: (1) Installation configuration of the six additional control cables instead of the bridging bar is permitted. (2) That 20 AWG is permitted to be used as control head cable in lieu of the manufacturer's required 18 AWG control head cable. If not permitted install system in accordance with the manufacturer's instructions to the satisfaction of the attending MI. 46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 3 October 2023
Resolution: Received email from vessel owner John from ZF rep. with photographs of page 239 and 241 in the manual, flagnote 18 specifically approves 20 AWG; all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 August 2023 Resolved
Penetrations and openings in the watertight bulkheads must have means to make them watertight. Bulkhead 19 penetrations on the stbd for new control cables are not watertight. Make water tight to the satisfaction of the attending MI. 46 CFR 171.114(a)(2) Old "T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 7 November 2023
Resolution: Bulkhead 19 penetrations on the stbd for new control cables and they are watertight; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 22 August 2023 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The new ZF MICROCOMMANDER processor wire from the battery to the circuit breaker for the stbd engine is excessively chaffed. Replace wire in-kind to the satisfaction of the attending MI. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 7 November 2023
Resolution: The chaffed wire for new ZF MICROCOMMANDER processor wire from the battery to the circuit breaker was replaced; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 19 May 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. During the deficiency check on May 19, 2023, the attending MI sighted the stbd main engine with excessively oil soaked exhaust insulation heat wrap. Remove oil soaked insulation, repair leak, operationally test for exhaust/oil leaks, and renew insulation to the satisfaction of the attending MI. 46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2023
Resolved 19 May 2023
Resolution: Received email from vessel Rep Tony of the stbd exhaust oil leak resolved and new exhaust insulation heat wrap installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 April 2023 Resolved
A device must be provided to automatically shut down engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Activation of the fixed CO2 system did not automatically shut down stbd engine. Replace solenoid. 46 CFR 181.410(b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2023
Resolution: Witnessed proper operational test of fixed CO2 system automatic shut down of stbd engine.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 April 2023 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. High water level alarm in rudder room was not wired. Rewire and demonstrate proper operation. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2023
Resolution: Inspected wiring of high water level alarm and witnessed proper operation.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 April 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Man overboard drill not conducted. Conducted MOB in the presence of the attending MI. 46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2023
Resolution: Conducted man overbard drill in the presence and to the satisfaction of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 April 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Conducted fire drill in the presence of the attending MI. 46 CFR 176.810(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2023
Resolution: Conducted satisfactory fire drill in the presence of the attending MI.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 April 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel’s hydrostatic release mechanism is expired. Replace hydrostatic release. 46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Inspected new hydrostatic release expiration date; all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 April 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 26 July 2023
Resolution: POC provided a copy of the FCC station license.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 April 2023 Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged or otherwise documented, as applicable. Operator was unable to provide log of EPIRB testing. Provide log of testing. 46 CFR 185.25-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Owner conducted EPIRB test in the presence of the attending MI and started an EPIRB log.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 April 2023 Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. No crew on-board had a valid radio operator permit. Provide proof of permit. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 July 2023
Resolution: POC provided proof of permit.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 April 2023 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel not maintaining logs for fire fighting drills and training. Provide proof of drills and training using log book. 46 CFR 185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Owner provided proof of drills and training log book to the satisfaction of the attending MI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 April 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and scenario and training topics. Vessel unable to provide drill/training logs. 46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 26 July 2023
Resolution: Reviewed vessel's log for the months of Feb-July. Vessel crew has been logging drills and training.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 April 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 65 feet in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessel replaced anchor light to use as stern light. Provide operable anchor light. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Observed proper operation of the anchor light.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 April 2023 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Motor/pump coupling on port side engine room is missing guard. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Atttending MI sighted required guard installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 April 2023 Resolved
Lifesaving equipment must be in serviceable condition. All three life floats were determined by the Marine Inspector to be not fit for service and removed during COI inspection 26OCT2021. Life floats have still not been replaced. Resolve by date or COI will be amended with "NOT MORE THAN THREE MILES FROM SHORE." 46 CFR 180.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 25 July 2023
Resolution: COI amended with "NOT MORE THAN THREE MILES FROM SHORE."
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Surge protectors found in several locations throughout the vessel. Remove surge protectors. 46 CFR 183.200 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Attending MI inspected the locations throughout the vessel where surge protectors were in use and found them removed from the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Several outlets were found with missing covers. Install covers on outlets. 46 CFR 183.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Attending MI inspected the vessel outlets and sighted all with covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas tight throughout its length and shall be properly supported by non-combustible hangers or blocks. In engine room, exhaust piping was missing support bracket. Install new bracket. 46 CFR 182.15-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 26 July 2023
Resolution: Vessel rep John provided a photograph of the new exhaust hanger.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2023 Resolved
This part prescribes regulations governing the design and construction of marine sanitation devices. Type III tank in rudder room inlet pipe had excessive pitting. Renew at next dry dock. 33 CFR 159.1
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 7 November 2023
Resolution: Sewage aluminum pipe trimmed and a new rubber connection hose installed with double hose clamps; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 April 2023 Resolved
Where flexibility is necessary a section of flexible metallic hose may be used. Non-metallic hose may be used provided it is especially adapted to resist the action of oil, acid and heat, and has a wall thickness sufficient to prevent collapsing or panting. Rubber wire reinforced exhaust hose in rudder room was found worn. Replace with approved flexible non-metallic hose as described above. 46 CFR 182.15-20(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Rubber wire reinforced exhaust hose in rudder room replaced with marine exhaust hose.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 3 April 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Bulkhead penetrations from engine room to rudder room are not properly sealed. Make vapor tight to ensure quantity of extinguisher is sufficient. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 26 July 2023
Resolution: Vessel rep John provided a photograph of the rudder room penetrations sealed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
Main distribution panels shall be of the dead front type where voltage to ground is in excess of 150 volts A.C. or 250 volts D.C. Switchboard in engine room had opening, allowing access to panel internals. Cover opening in switchboard. 46 CFR 183-10-15(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Attending MI sighted opening in the switchboard with breaker installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
Electrical equipment used in the following locations must be drip proof: A location normally exposed to splashing or water washdown. Four inches of standing water sighted underneath the bridge console. Remove water and resolve source of water ingress. 46 CFR 183.210(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Attending MI inspected underneath of bridge console and sighted no standing water. The source of the water ingress was sealed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Circuit breakers in engine room had exposed contacts. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Attending MI inspected work bench for circuit breaker with exposed contact; breaker removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2023 Resolved
This section applies to each vessel that fits into any one of the following categories:(1) A vessel of more than 65 feet length; all vessels must have permanent draft marks at each end of the vessel. Vessel does not have aft draft marks as required by the stability letter. 46 CFR 185.30-1(a)(b)(1)
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 7 November 2023
Resolution: Draft marks permanently affixed and painted a contrasting color; all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Identified the following hazardous electrical practices: evidence of burn marks on outlet covers, exposed wires on port air compressor, missing conduit covers on box lights, and disconnected exterior forward mounted light. Correct hazardous electrical items to the satisfaction of the attending Marine Inspector. 46 CFR 183.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: All hazardous electrical items were corrected to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in Subchapter J. Discovered multiple extension cords running to bar, kitchen, and engine room lights not approved for use under Subchapter J. Remove extension cords. 46 CFR 183.340(r)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Attending MI inspected the vessel for extension cords and the extension cords at the bar, kitchen, and for the engine room lights were removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips are expired. Replace alcohol test strips. 46 CFR 4.06-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Owner provided new alcohol test strips to the satisfaction of the attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2023 Resolved
The employer shall provide an Employee Assistance Program for all crewmembers that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. No evidence of supervisory nor crew training on the effects and consequences of drug and alcohol use. Provide evidence of such training to supervisors and crew. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2023
Resolved 19 July 2023
Resolution: POC provided proof of supervisory training was completed June 2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment. Vessel’s centerline engine not operable. Provide repair plan timeline to the satisfaction of the attending Marine Inspector. 46 CFR 177.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 25 July 2023
Resolution: Received an email with the proposed repair plan/time line for bringing center main engine online by August 15, 2023.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2023 Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. Port amidships cleat not properly seated due to cracked weld on deck underneath. Do not use cleat until properly welded to deck to the satisfaction of the attending Marine Inspector. 46 CFR 177.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Attending MI inspected repair of the port amidships cleat; all sat. Authorized cleat use.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2023 Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. Numerous cracked and worn welds identified on board. Repair welds at next dry dock. 46 CFR 177.10-1
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 6 November 2023
Resolution: Did not identify cracked welds. Will clear deficiency and add a special note for this item.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2023 Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. Identified unapproved weld repair on the port side of the rudder room. Correct at next dry dock. 46 CFR 177.10-1
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 7 November 2023
Resolution: Repair accepted due to no sign of having any structural issues. Special note added.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 3 April 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel missing the second radio required by the Bridge-To-Bridge Radiotelephony Certificate. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 19 May 2023
Resolution: Owner provided the attending MI a VHF/FM radio to comply with the second radio required by the Bridge-To-Bridge Radiotelephony Certificate.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 March 2023 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. During the damage survey, following discovery of unapproved repair progress by MI, it was determined that the damage did not effect the seaworthiness of the vessel. This vessel may continue to operate, however they must effect permanent repairs at their next drydocking to receive credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 16 November 2023
Resolution: Bow insert passed viual weld inspection, vacuum box NDT, and dye penetrant NDT; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 March 2023 Resolved
Immediately after the addressing of resultant safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office, Marine Inspection Office, or Coast Guard Group Office whenever a vessel is involved in a marine casualty consisting of: (3) Loss of main propulsion or primary steering, or any associated component or control system, that reduces the maneuverability of the vessel. During an inspection of a vessel in Kewalo Basin the attending MI's observed staging on the bow of the inspected vessel PRINCE KUHIO associated with an in-water repairs. A Coast Guard (CG) marine inspector (MI) visited the vessel and was told by the C/E the vessel control linkage at the reduction gear had detached causing the bridge propulsion controls to become inoperable resulting in the allision of the PRINCE KUHIO with the Kewalo pier structure. Passenger carriage is not permitted until an MI attends the vessel to conduct a damage survey, vessel owner/operator provides a repair proposal for CG review/approval, and repairs are completed to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2023
Resolution: MI attended and conducted damage survey. Damage was determined not to impact seaworthiness and 835 was issued to make permanent repair at next drydocking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Effect repairs to restore propulsion plant to operate as designed prove proper operation of plant to attending Marine inspector. Your vessel is prohibited from transiting any port within the sector Honolulu COTP zone without the assistance from towing vessel(s) of adequate horsepower and maneuverability. Such towing vessel(s) shall be under the direction and control of an individual holding a Merchant Marine Credential (MMC) authorizing them to engage in assistance towing under the provisions of 46 CFR Part 11.482. 46 CFR 182.200 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2022
Resolution: Vessel demonstrated proper operation of fuel and propulsion system to attending [name withheld] trial sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 January 2022 Resolved
At each inspection for certification the fire hose shall be subjected to the available fire hose pressure. The port fire hose leaked when subjected to the pump output pressure. Provide a new fire hose. 46 CFR 176.25-25(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 January 2022
Resolution: A new fire hose was provided and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 January 2022 Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Missing double hose clamps on raw water intake. 46 CFR 182.410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 January 2022
Resolution: Double hose clamps were installed where required.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 January 2022 Resolved
All machinery and equipment must be installed and maintained in an such a manner as to afford adequate protection from personnel injury. The ensure prevention of personnel injury the vessel Captain shall provide a written policy stating that the vessel is normally unmanned and to verify the space is clear of personnel prior to the activation of the fixed extinguishing system. 46 CFR 126.25-1 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: A written company policy was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 January 2022 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity. Vessel's secondary generator was not in service. Bring adequate secondary source of power into working condition. 46 CFR 183.310(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2022
Resolution: The second generator was re-installed and load tested sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 January 2022 Resolved
The owner or managing operator or a qualified servicing facility shall conduct inspections and tests as applicable for fixed gas fire extinguishing systems and must provide evidence of the required servicing to the marine inspector. Vessel's fixed gas fire extinguishing system servicing was outdated. Bring system into compliance. 46 CFR 176.810(b)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2022
Resolution: Fixed gas fire fighting system was serviced and issued a compliance certificate by a certified technician.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 January 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Acquire serviceable life jackets are required for all passengers. Multiple life jackets were found un-serviceable, total POB is limited to 125. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 January 2022
Resolution: Replacement life jackets were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 January 2022 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals and six hand orange smoke distress signals. Vessel missing 06 orange smoke flares. Vessel is restricted within 3NM from a harbor of safe refuge until the correct number of distress signals are acquired. 46 CFR 180.68(a)
Action required: 705 - Other - as specified
Resolved 10 January 2022
Resolution: Required distress signals for limited coastwise route provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 January 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Hazardous electrical practices, including standing water underneath the pilothouse electronics, and hazardous configurations discovered in the pilothouse and engine room. Bring vessel's electrical configuration into compliance. 46 CFR 183.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2022
Resolution: Vessel properly configured electrical equipment.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 January 2022 Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel's FCC Bridge-to-Bridge Radio Certification expired. Update document to current status. 47 CFR 80.405
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2022
Resolution: Owner provided a current Bridge-to-Bridge certificate for the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 January 2022 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position or perform the duties and functions of a position, required by the vessel's COI. Marine employers may form or otherwise use sponsoring organizations, or may use contractors to conduct the random chemical testing programs. Vessel missing DAPI policy, crew and supervisor training, and letter of regulatory compliance from the consortium. Provide all requirements. 46 CFR 16.230(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 23 March 2022
Resolution: Company DER provided proof of adequate supervisory training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2021 Resolved
Machinery, equipment, materials and arrangements not covered by standards in this chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The submersible bilge pump servicing the forward compartment has plastic piping that penetrates the aft bulkhead. A positive stop valve with remote reach rod that is accessible by the crew members must be provided on the galley side of the bulkhead. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 6 December 2021
Resolution: A positive stop valve with reach rod was provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 November 2020 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The fire pump onboard did not exceed 20 psi of discharge pressure. Provide proof of 60 psi discharge pressure of the fire pump in the presence of the Marine Inspector. 46CFR181.300
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2020
Resolved 12 November 2020
Resolution: Operator installed new fire pump. Operational test conducted; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020 Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gastight throughout its length. Three pinholes leaking oil found in starboard center main exhaust muffler. Submit repair proposal for Coast Guard approval to seal. 46 CFR 182.15-20(a) “Old T”
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2020
Resolved 12 November 2020
Resolution: Repaired to the satisfaction of the attending Marine Inspector IAW vessel's approved repair proposal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020 Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gastight throughout its length. Port main engine exhaust piping wasted and leaking. Submit repair proposal for Coast Guard approval to rectify. 46 CFR 182.15-20(a) “Old T”
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2020
Resolved 12 November 2020
Resolution: Repaired to the satisfaction of the attending Marine Inspector IAW vessel's approved repair proposal.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 9 November 2020 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: Every power driven vessel of 20 meters (65.6 feet) or over in length while navigating. The vessel is prohibited in carrying passengers for hire until a valid Bridge-to-Bridge certificate is onboard the vessel. 47CFR80.1001(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2020
Resolved 13 November 2020
Resolution: Received vessel's valid FCC Bridge-to-Bridge certificate.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 9 November 2020 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47CFR80.59 once every five years. The vessel does not have a valid FCC radio safety certificate onboard. The vessel is limited in operation to no more than 1000 feet from shore until a valid FCC radio safety certificate is onboard. 47CFR80.903
Action required: 705 - Other - as specified
Due 9 November 2020
Resolved 17 November 2020
Resolution: Received vessel's FCC Radio Safety Telephony certificate.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 November 2020 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The EPIRB hydrostatic release was expired. The vessel is restricted to no more than 3 NM from shore until the hydrostatic release is replaced. 46 CFR 185.740(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2020
Resolved 12 November 2020
Resolution: EPIRB hydrostatic release replaced in the presence of the Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 November 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2). VHF radio missing MMSI and LAT/LONG for DSC operation on bridge operating station VHF radio. Provide proof of VHF radio containing MMSI and LAT/LONG for DSC operation to the Marine Inspector. 47 CFR 80.905
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 13 November 2020
Resolution: Received report from vessel's FCC technician for proper installation of MMSI and LAT/LONG.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 November 2020 Resolved
All vessels of more than 19.8 meters (65 feet) in length must have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights.” Restore the starboard green navigation light cover to the satisfaction of the Marine Inspector. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Vessel installed new starboard navigation light that meets UL 1104.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 9 November 2020 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. The vessel did not have an up-to-date Stability Letter onboard. Post the stability letter to the satisfaction of the Marine Inspector. 46 CFR 176.306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Vessel posted up-to-date stability letter.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 November 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts & publications IAW 46CFR184. Vessel was missing all required charts & publications. Provide proof of charts and publications onboard. 46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 12 November 2020
Resolution: Up-to-date charts and nautical publications onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020 Resolved
Connections must be made to battery terminals with permanent type connectors. 04 wing nuts were discovered on the port battery installations. Replace wing nuts with proper mechanical fittings to the satisfaction of the Marine Inspector. 46CFR183.350(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Vessel installed proper mechanical type fittings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 November 2020 Resolved
Gauges to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Main engine cooling water discharge temperature and lubricating oil pressure gauges were inoperable. Repair gauges and provide proof to the satisfaction of the Marine Inspector. 46CFR182.20-5(b) "Old T"
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 15 December 2020
Resolution: All gauges repaired and operation verified to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020 Resolved
Exhaust piping shall be gas tight throughout its length and properly supported by non-combustible hangers or blocks. The port diesel generator exhaust cooling has a failed hose clamp. Repair the failed hose clamp to the satisfaction of the Marine Inspector. 46CFR182.15-20(a) "Old T"
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 9 December 2020
Resolution: Failed hose clamp replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 November 2020 Resolved
Complete but simple instructions must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. Schematic diagram is missing; provide and post schematic diagram. 46CFR181.20-15(d) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: CO2 schematic posted.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 November 2020 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR.” Emergency exit labeling for engine room is peeling off. Relabel engine room emergency exit. 46CFR185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Engine room escape relabeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2020 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Several fuel oil filters were missing strainer bowls. Install strainer bowls IAW manufacturer’s requirements. 46CFR182.455(b)(6)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 15 December 2020
Resolution: Metallic flame screens installed over each fuel oil filter bowl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2020 Resolved
To avoid water and exhaust gases from ingress into the engine room, install caps in both generator exhaust drain valves. 46 CFR 176.25-1(a) “Old T”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Drain valves installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2020 Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas tight throughout its length. Forward main flange gasket wasted and leaking oil. Replace gasket. 46 CFR 182.15-20(a) “Old T”
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 15 December 2020
Resolution: Gasket replaced to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
At each initial and. subsequent inspection for certification and re-inspection" the marine inspector shall examine the passenger and crew quarters, toilet -and washing spaces, galleys, serving pantries, lockers, etc., to determine that they are serviceable and in a sanitary condition. Black water tank flex hose is missing double hose clamps at tank connection and aluminum pipe observed wasted. Remove hose and inspect inlet side of pipe for wastage. Notify [email withheld] of findings and submit repair proposal for Coast Guard approval if required. 46 CFR 176.25-45(a) “Old T”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Hose replaced and double hose clamped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2020 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Center main port wet exhaust hose is weeping and the hoses are wasted. Starboard main engine flex hose leaking. Replace flex hoses and install double hose clamps where required. 46 CFR 176.25-50(a) “Old T”
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 15 December 2020
Resolution: Flex hose replaced to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 November 2020 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arrestors. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. There are holes in both port and starboard fuel tank flame screens. Replace flame screens. 46CFR182.20-35(d) “Old T”
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 15 December 2020
Resolution: Flame screens replaced to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Repair leak above service compressor for heads. 46CFR182.01-5(a) “Old T”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Nonmetallic piping resealed to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. The vessel did not have a current crew list of individuals employed onboard the vessel, and enrolled in the drug testing program. Provide a valid crew list to the satisfaction of the Marine Inspector. 46CFR16.230
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Crew list provided to the satisfaction of the Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with 46 CFR 4.06. The vessel had no method of conducting serious marine incident alcohol testing within 2 hours. Provide proof of alcohol test strips onboard to the satisfaction of the Marine Inspector. 46CFR16.240
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2020
Resolved 9 December 2020
Resolution: Alcohol test strips provided onboard.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 November 2020 Resolved
Provisions must be made for closing all supply duct cowls or scoops for a space protected by a fixed gas extinguishing system. The vessel's 02 generator intakes on the main deck did not have a means of closure. Provide a means of closure to the satisfaction of the Marine Inspector. 46CFR182.465(h)
Action required: 10 - Deficiency Rectified
Due 20 November 2020
Resolved 20 November 2020
Resolution: Means of closure not required as supply ducts do not provide air to space protected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
All electrical equipment and circuits must be clearly marked and identified. The port switchboard at the operating station is not labeled, and has unidentified circuit breakers. Clearly mark and identify the circuit breakers IAW 46CFR183.220. 46 CFR 183.220(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Switchboard labeled to the satisfaction of the Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. The kitchen area has 120 VAC outlets which are missing faceplates. Replace the faceplates to the satisfaction of the Marine Inspector. 46CFR183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Faceplates installed to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Numerous dead end wires were discovered under the console at the operating station. Remove or properly terminate the wires to the satisfaction of the Marine Inspector. 46CFR183.340(g)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2020
Resolved 15 December 2020
Resolution: Dead end wires removed to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Each pressure type wire connector and lug must meet UL486A. Numerous unauthorized automotive type connections were discovered under the console at the operating station. Replace the connections with proper pressure type wire connectors meeting UL standards. 46CFR183.340(i)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2020
Resolved 15 December 2020
Resolution: Connections replaced to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. A power strip was discovered under the console at the operating station servicing unknown electrical equipment. Identify the electrical equipment being serviced, remove the power strip, and ensure proper circuit protection to the satisfaction of the Marine Inspector. 46CFR183.380
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2020
Resolved 15 December 2020
Resolution: Unknown electrical equipment removed and placed out of service.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. The vessel has numerous lighting fixtures which have open electrical plugs. Seal the electrical plugs to the satisfaction of the Marine Inspector. 46CFR183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Electrical plugs sealed to the satisfaction of the marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Electrical equipment used in the following locations must be drip proof. Steering feedback unit in lazarette, and bilge alarm float switch. 46 CFR 183.210(a)(3)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Drip proof enclosure installed to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2020 Resolved
Electrical equipment must be installed to protect from electrical hazards. Dead end wires found at the forward exterior of male head. Properly remove or cover to prevent potential shock or fire hazards. 46 CFR 183.200
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Dead end wires removed to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 November 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Seal opening in aft heat detector for CO2 system. 46CFR183.200(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Opening sealed to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire. An excessive amount of electrical cable was found coiled under the console at the operating station. Remove the excessive coil of cable to reduce an electrical fire hazard to the satisfaction of the Marine Inspector. 46CFR183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2020
Resolved 15 December 2020
Resolution: Excess electrical wire removed to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2020 Resolved
All electrical equipment shall be drip proof protected. Totally enclosed distribution panel. #2 switchboard in galley has an opening where an old breaker was removed. Blank off opening. 46 CFR 183.10-10(a) “Old T”
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Opening blanked off to the satisfaction of the Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 November 2020 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. Cover or close opening in engine room overhead aft on starboard side. Cap old wire stuffing tube on weather deck of forward peak. 46 CFR 176.176.25-5(a)(1) “Old T”
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2020
Resolved 15 December 2020
Resolution: Wire stuffing tube sealed to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2020 Resolved
Accessories, such as switches, fuses, and sockets, shall be standard National Electric Code types for the loads to be carried and shall be of types UL-listed. Energizing service air compressor requires opening enclosure to manually close contacts. Replace or repair service air compressor start switch. 46CFR183.05-35(a) “Old T”
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2020
Resolved 15 December 2020
Resolution: Air compressor properly placed out of service.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 November 2020 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Either remove the breaker on starboard side forward of service air compressor, or place it in an approved enclosure and properly wire. 46 CFR 183.01-5(a) “Old T”
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Breaker placed in approved enclosure to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 November 2020 Resolved
Over current protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. The PA system was connected to an unauthorized power strip. 46CFR183.380
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: The use of the power strip was discontinued in the presence of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 November 2020 Resolved
If the vessel carries more than one life float in a group with each group secured by a single painter: (3) Each life float must be individually attached to the painter by a line long enough that each life float can float without contacting any other life float in the group. The 03 life floats were rigged as a group, but were not secured with a single painter. 46 CFR 180.137(e)(3)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: The life floats were properly rigged in the presence of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2020 Resolved
Each child size life jacket must be stowed in a location that is separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. 01 Adult PFD was found in the stowage area of the child size life jackets. 46 CFR 180.78(a)(5)
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: The stowage was corrected in the presence of the Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 November 2020 Resolved
Each EPIRB must be tested monthly, using the integrated test circuit. The EPIRB test shall be logged. The vessel had no log of monthly EPIRB testing. 46 CFR 185.728(a)
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: The EPIRB test was conducted, and logged in the presence of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 November 2020 Resolved
The inspection and maintenance of the equipment listed in 46CFR185.702 shall be logged or documented for review by the Coast Guard upon request. The vessel had no log of inspection and/or maintenance of primary survival craft. 46 CFR 185.702(d)
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: The survival craft was inspected, and logged in the presence of the Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
The master shall ensure that the ship is not operated unless a garbage management plan is on the ship. The vessel did not have a Garbage Management Plan. 33 CFR 151.57(a)
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: The Garbage Management Plan was created in the presence of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 December 2019 Resolved
Fire hoses shall be 1 1/2" in diameter and 50 feet in length. 1 1/2" Fire hose must: Be lined commercial fire hose that conforms to Underwriter's Laboratories Inc., Standard 19 or Federal Specification ZZ-H-451E. Both of vessels two fire hoses leaking significantly and no longer in serviceable condition. Replace both hoses with approved UL 50 ft length and test in presence of attending Marine Inspector prior to carrying passengers. 46 CFR 181.15-10(c)&(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2019
Resolved 6 December 2019
Resolution: Renewed both hoses, operational test sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 December 2019 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. During operational test of fire pump, pressure gage at outlet reading 20 psi. Make 60 psi in presence of attending Marine Inspector. 46 CFR 181.10-1 (e)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2019
Resolved 6 December 2019
Resolution: Renewed fire pump, operational test sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 5 December 2019 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not have the correct number of passengers allowed posted. Make changes to indicate maximum of 60 passengers on the upper deck IAW stability letter dated March 22, 2017. 46 CFR 185.602 (g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2020
Resolved 6 December 2019
Resolution: placard updated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 December 2019 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessel's remote fuel shutoff station not labeled. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2020
Resolved 6 December 2019
Resolution: Installed markings
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2019 Resolved
The minimum number of portable fire extinguishers required on each vessel shall be as determined by the Officer in Charge, Marine Inspection n accordance with Table 181.30-1(a). No fire extinguisher at propane grill on stern. Provide 40 B:C extinguisher in the vicinity. 46 CFR 181.30-1 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2020
Resolved 6 December 2019
Resolution: Extinguisher installed, COI amended.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 December 2019 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessels emergency broadcast placard had outdated call sign. 46 CFR 184.506
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2020
Resolved 6 December 2019
Resolution: placard updated
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 October 2019 Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Railing on stbd side fractured in 2 locations. 46 CFR 177.35-1 (a)
Action required: 705 - Other - as specified
Resolved 30 October 2019
Resolution: Vessel ground and rewelded all affected areas.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2019 Resolved
Where the internal framing, plating, or planking of the vessel is concealed, sections of the lining, ceiling or insulation may be removed so that the inspector may be satisfied as to the condition of the hull structure. Remove sections of ceiling from main deck overhead for attending marine inspector to see condition of support structure of upper passenger deck. 46 CFR 176.610 (b)
Action required: 705 - Other - as specified
Resolved 30 October 2019
Resolution: Vessel removed ceiling tiles and provided for inspection. No irregularities noted. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2019 Resolved
Where the internal framing, plating, or planking of the vessel is concealed, sections of the lining, ceiling or insulation may be removed so that the inspector may be satisfied as to the condition of the hull structure. Remove sections of ceiling from port side engine room overhead where salt is building up for marine inspector to reinspect. 46 CFR 176.610 (b)
Action required: 705 - Other - as specified
Resolved 30 October 2019
Resolution: Vessel removed tiles for further inspection. No irregularities noted. All sat.
Lifesaving › Lifefloat › Float-free Link
Issued 10 January 2017 Resolved
Float free link for center life float undersized IAW 46 CFR 160.073-10(b)(3)
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 2 February 2017
Resolution: Float free link for center life float replaced.
Communications › Public Address System › Broadcast Location
Issued 10 January 2017 Resolved
PA system not functional at all accomodation spaces IAW 46 CFR 184.610
Due 24 January 2017
Resolved 2 February 2017
Resolution: Verified PA system functional at all accomodation spaces.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 January 2017 Resolved
Vessel COD not current IAW 46 CFR 67.7
Due 24 January 2017
Resolved 2 February 2017
Resolution: Vessel COD updated and current.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 January 2017 Resolved
Vessel FCC certificates not current IAW 46 CFR 80, 13.
Due 24 January 2017
Resolved 2 February 2017
Resolution: Vessel FCC certificates updated and current.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 January 2017 Resolved
Vessel communications during man overboard drill inadequate to meet the requirements of 46 CFR 180.210
Due 24 January 2017
Resolved 12 January 2017
Resolution: Observed satisfactory demonstration of drills utilizing hand held radios.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 January 2017 Resolved
Lagging on generators exhaust elbows needs to be replaced IAW 46 CFR 176.25-50
Due 24 January 2017
Resolved 2 February 2017
Resolution: Lagging on generators exhaust elbows replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 10 January 2017 Resolved
Exhaust gasket on center engine stbd side and associated lagging saturated with oil, needs to be replaced IAW 46 CFR 176.25-50
Due 24 January 2017
Resolved 2 February 2017
Resolution: Exhaust gasket on center engine stbd side and associated lagging replaced.
Engineering › Fuel Oil Service System › Hose
Issued 10 January 2017 Resolved
Fuel hose on port side generator needs to be replaced IAW 46 CFR 182.720(e)
Due 24 January 2017
Resolved 2 February 2017
Resolution: Fuel hose on port side generator replaced.
Engineering › Fuel Oil Service System › Filter
Issued 10 January 2017 Resolved
Fix fuel leak on port side generator fuel filter housing, IAW 46 CFR 176.25-50
Due 24 January 2017
Resolved 2 February 2017
Resolution: Fuel leak on port side generator fuel filter housing fixed.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 10 January 2017 Resolved
Provide battery ventillation IAW 46CFR 183.05-20
Due 24 January 2017
Resolved 2 February 2017
Resolution: Battery ventillation provided.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 January 2017 Resolved
Provide chaff gear on electrical cables IAW 46 CFR 176.25-50
Due 24 January 2017
Resolved 2 February 2017
Resolution: Chaff gear provided on electrical cables
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 10 January 2017 Resolved
Replace cover of junction box on stbd generator IAW 46 CFR 176.25-50
Due 24 January 2017
Resolved 2 February 2017
Resolution: Cover of junction box on stbd generator replaced.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 January 2017 Resolved
Replace damaged rudder angle indicator IAW 46 CFR 182.610(f)(2)
Due 24 January 2017
Resolved 2 February 2017
Resolution: Rudder angle indicators functioning satisfactory.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 January 2017 Resolved
Provide ammeter on bridge and starter battery chargers IAW 46 CFR 183.05-20(f)
Due 24 January 2017
Resolved 2 February 2017
Resolution: Bridge and starter battery chargers replaced to include built in ammeters.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 January 2017 Resolved
Provide strain relief on both generator cables IAW 46 CFR 176.25-50
Due 24 January 2017
Resolved 2 February 2017
Resolution: Strain relief on both generator cables provided.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 January 2017 Resolved
Remove circuit breakers to neutral wires on switchboard IAW 46 CFR 111.05-39
Due 24 January 2017
Resolved 2 February 2017
Resolution: Circuit breakers to neutral wires on switchboard removed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 January 2017 Resolved
Replace ground detector indicator IAW 46 CFR 183.10-30, 111.05-21
Due 24 January 2017
Resolved 2 February 2017
Resolution: Ground detector indicator functioning satisfactory.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 January 2017 Resolved
Replace pilot light on generator switchboard IAW 46 CFR 183.10-5
Due 24 January 2017
Resolved 2 February 2017
Resolution: Pilot light on generator switchboard replaced.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 January 2017 Resolved
Replace cable terminal connections on electrical cables in switchboard IAW 46 CFR 176.25-50
Due 24 January 2017
Resolved 2 February 2017
Resolution: Cable terminal connections on electrical cables in switchboard reinstalled with washers.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 January 2017 Resolved
Man overboard drills not conducted with all crew, demonstrate crew competency and ensure crew onboard fully participate to evaluate proficiency IAW 46 CFR 185.520
Due 24 January 2017
Resolved 12 January 2017
Resolution: Observed satisfactory demonstration of man overboard drills.

Casualty record · 4

29 September 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2246199
4 March 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2888152
2 November 2022Routine · role: Involved in a Marine Casualty · activity 7588503
4 February 2023Routine · role: Involved in a Marine Casualty · activity 7664229
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.