Records from 1993 to 2004. Most recent: inspection, 1 November 2004.
Inspection history · 62
1 November 2004
Excursion Permit · Attraction Vessel Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2233189
12 September 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 118629
7 September 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 772445
28 June 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401519
4 January 2001
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361928
24 October 2000
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1463620
23 October 2000
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822997
21 October 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 104253
22 June 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 173509
1 June 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361524
26 May 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373047
18 February 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 182572
6 April 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1453585
26 January 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 23955
9 October 1998
Hull Examination · MARPOL Annex V Examination · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368890
8 October 1998
Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 806719
24 September 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 66257
3 April 1998
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378334
10 January 1998
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 777970
8 January 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 46064
8 January 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 171538
1 July 1997
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 777328
26 June 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 18161
13 May 1997
Examination of Repairs · MARPOL Annex V Examination · Hull Examination · Damage Survey · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394747
8 April 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 116775
1 April 1997
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1094005
11 March 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 88410
5 March 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 26101
5 January 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 18703
5 January 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 82662
29 August 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 140881
3 July 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355890
7 June 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1404198
17 May 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1422684
1 May 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 150818
15 April 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 129860
5 April 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1407645
4 March 1996
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355690
1 March 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 884968
8 February 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371288
16 January 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 5487
4 January 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363458
24 November 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363428
6 November 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 882514
1 November 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 41595
13 July 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1190197
8 June 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360141
21 April 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358722
18 April 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 135478
13 April 1995
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358681
13 February 1995
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1444946
10 February 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 16998
3 January 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 854127
16 August 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 108882
3 August 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389874
30 July 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 73372
27 June 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389873
6 June 1994
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469436
5 May 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 35976
30 April 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1451950
11 March 1994
Inclining Experiment · MARPOL Annex V Examination · Initial Certification · Plan Review "T" Boat · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354745
24 September 1993
Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1449637
Documentation
Issued 28 June 2001
Resolved
Provide Certificate of Documentation in accordance with 46 CFR 67.313.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Lifesaving
Issued 28 June 2001
Resolved
Provide current NOAA registration for EPIRB in accordance with 47 CFR 80.1061(e)(f).
Condition: Unknown
Due 14 July 2001
Resolved 23 July 2001
Lifesaving
Issued 28 June 2001
Resolved
Provide orange ring lifebuoy in accordance with 46 CFR 180.70.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Lifesaving
Issued 28 June 2001
Resolved
Provide (3) adult life jackets and replace retro-reflective material on (11) adult jackets in accordance with 46 CFR 185.71 and 46 CFR 185.604(h), respectively. Passenger count is reduced by (14) until corrected.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Deck/Cargo
Issued 28 June 2001
Resolved
Replace or repair relief valve on anchor winch in accordance with 46 CFR 182.100.
Condition: Unknown
Due 14 July 2001
Resolved 23 July 2001
Accommodation/Occupational Safety
Issued 28 June 2001
Resolved
Repair broken glass on port head door in accordance with 46 CFR 184.502.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Documentation
Issued 28 June 2001
Resolved
Provide passenger count and crew list in accordance with 46 CFR 185.504 and46 CFR 185.502, respectively.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Lifesaving
Issued 28 June 2001
Resolved
Replace outdated EPIRB hydrostatic release in accordance with 46 CFR 185.740.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Documentation
Issued 28 June 2001
Resolved
Provide current training, lifesaving maintenance and bridge logs in accordance with 46 CFR 185.420.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Lifesaving
Issued 28 June 2001
Resolved
Complete satisfactory fire and man overboard drills prior to carrying passengers.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Lifesaving
Issued 28 June 2001
Resolved
Provide first aid kit in accordance with 46 CFR 184.710.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Unknown
Issued 28 June 2001
Resolved
Replace or repair hydraulic valve for starboard fin stabilzer unit in accordance with 46 CFR 182.100.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Navigation
Issued 28 June 2001
Resolved
Prove proper operation of VHF radio in accordance with 46 CFR 184.502.
Condition: Unknown
Due 5 July 2001
Resolved 23 July 2001
Construction/Loadline
Issued 23 October 2000
Resolved
Damaged hull #1 STBD ballast tank. Effect permanent repair as per 46CFR176.700 and 46CFR57.02-4 that is acceptable to the cognizant OCMI, prior to carrying passengers NLT 30OCT00. Contact MSO Honolulu to schedule inspection prior to conducting repairs.
Condition: Unknown
Due 2 November 2000
Resolved 2 November 2000
Lifesaving
Issued 5 April 1996
Resolved
Conduct annual servicing of both liferafts no later than July 15, 1996.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Accommodation/Occupational Safety
Issued 5 April 1996
Resolved
Post, at each entrance to the upper deck, a sign stating no more than 51 passengers on the upper deck.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Navigation
Issued 5 April 1996
Resolved
Renew lens or remove paint from stern light lens.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Provide a 3-6 foot lanyard for the ring buoy waterlight.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Accommodation/Occupational Safety
Issued 5 April 1996
Resolved
Post, in plain view of the crew and passengers, the waste management plan.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Install a pressure gauge on the high pressure side between the cylinder valve and the pressure regulator; provide and post operating instructions and two warning signs; and conduct and log biweekly leak tests of the propane gas grill.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Double hose clamp all salt water hoses in the port and stbd engine rooms.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Fire Fighting
Issued 5 April 1996
Resolved
Renew defective fire pump pressure gauge and prove the fire pump can develop a minimum of 50 GPM at 60 psi.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 5 April 1996
Resolved
Install emergency disconnect switches for each 12 volt battery located in the port and stbd generator spaces, and in the A/C room.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Install a fuel shutoff valve at the engine for each ship service generator.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Permanently repair salt water leaks on hydraulic system salt water cooling pump, port engine room.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Accommodation/Occupational Safety
Issued 5 April 1996
Resolved
Properly pipe (plumb) salt water suction for the A/C cooling salt water cooling pump located in the stbd forward machinery space.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Permanently repair salt water leaks on the port and stbd MDEs 2.5" salt water overboard lines.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Renew, in kind, the 2.5" salt water flex hose located on the discharge sideof the salt water strainer for the stbd MDE.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Remove excess flammables from the port fuel tank void.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996
Resolved
Permanently repair leaks on the newly installed bilge piping located in theport and stbd forward machinery rooms.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 5 April 1996
Resolved
25. Properly label the electrical shore power receptacle.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996
Resolved
Provide a suction strainer for the portable hand bilge/fire pump.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Fire Fighting
Issued 5 April 1996
Resolved
Provide a suitable means to secure the air to the engine room in the event of a fire.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996
Resolved
Bring bilge system into compliance with approved plans dated April 9, 1996.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 5 April 1996
Resolved
Wiring installations for the battery emergency disconnect switches and the air compressor located in the A/C must comply with 46 CFR 183.340.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Navigation
Issued 5 April 1996
Resolved
Post a radio emergency broadcast placard in accordance with 46 CFR 184.506.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996
Resolved
Properly label all watertight hatches in accordance 46 CFR 185.610.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Bench test and certify popping and seating pressures for the ship service air receiver relief valves. Provide MSO Honolulu a copy of the test results.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Install 2.5" gooseneck vents for the port and stbd fuel tank void spaces. Vent outlets shall terminate on the weather deck.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996
Resolved
Permanently secure to the deck, the air compressor assembly located in the A/C room.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 5 April 1996
Resolved
Repair and prove operation of the main switchboard ground indicator.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 5 April 1996
Resolved
In lieu of flexible cord, hard wire the air compressor assembly located in the A/C room.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Fire Fighting
Issued 5 April 1996
Resolved
Label on the exterior of the A/C room the location of fire station #2 and the fire extinguishers which are located within the A/C room.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Conduct passenger safety orientation in accordance with 46 CFR 185.506.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Post PFD placards in accordance with 46 CFR 185.516.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Post inflatable liferaft placards in accordance with 46 CFR 185.518.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Provide manufacturer maintenance instructions for the survival craft in accordance with 46 CFR 185.702.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Properly label all lifesaving equipment in accordance with 46 CFR 185.604.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Provide a suitable container for the distress signals in accordance with 46CFR 185.614.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Conduct and log weekly maintenance and inspection of the survival craft in accordance with 46 CFR 185.720.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996
Resolved
Conduct and log monthly inspection of the survival craft in accordance with46 CFR 185.722.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996
Resolved
Replace all plastic through hull fittings with metallic fittings throughoutthe vessel.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Documentation
Issued 8 February 1996
Resolved
SUBMIT CG-2692 FOR FAILURE TO PORT RUDDER RAM.
Condition: Unknown
Due 9 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 4 January 1996
Resolved
Make permanent repairs to forward bulkhead of the port forward potable water tank where cracked and soft patched.
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Construction/Loadline
Issued 24 November 1995
Resolved
Install bilge system in accordance with 46 CFR 182.25.
Condition: Unknown
Due 24 November 1995
Resolved 24 November 1995
Construction/Loadline
Issued 24 November 1995
Resolved
Install ballast system in accordance with 182.40-5.
Condition: Unknown
Due 24 November 1995
Resolved 24 November 1995
Navigation
Issued 6 November 1995
Resolved
REPOSITION NAVIGATION SIDE LIGHTS/MASTHEAD LIGHT IAW COLREGS, ANNEX I 84.05(c). (Navigation side lights are forward of the forward masthead light.)
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Documentation
Issued 21 April 1995
Resolved
PROVIDE COPY OF RICHARD NEWCOMBS MASTERS LICENSE.
Condition: Unknown
Due 24 April 1995
Resolved 27 April 1995
Documentation
Issued 21 April 1995
Resolved
PROVIDE A COPY OF VESSEL LOGS FROM 14 APRIL UNTIL 21 APRIL 1995.
Condition: Unknown
Due 24 April 1995
Resolved 27 April 1995
Electrical
Issued 13 April 1995
Resolved
INSTALL BLANK IN ELECTRICAL DISTRIBUTION PANEL STARBOARD SIDE MACHINERY SPACE LADDERWAY
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Engineering
Issued 13 April 1995
Resolved
INSTALL BILGE SYSTEM IN ACCORDANCE WITH 46CFR182.25.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Engineering
Issued 13 April 1995
Resolved
INSTALL/MODIFY BALLAST SYSTEM PIPING TO COMPLY WITH 46CFR182.40-5
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
PROVIDE ADEQUATE LINING FOR BATTERY BOXES AND COVERS IN ACCORDANCE WITH 46CFR 183.05-20(a & d)
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
Properly secure dead end wire in generator/ship's service electrical distribution panel.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Lifesaving
Issued 13 April 1995
Resolved
Properly label PFD stowage on main deck in accordance with 46 CFR 180-25-15- vessel not to operate with passengers until this item is completed.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
Properly secure dead end wires main deck outboard starboard side.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Lifesaving
Issued 13 April 1995
Resolved
Provide all PFD's for inspection. This item is to be completed before vessel operates w/ passengers.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
INSTALL LIGHT BULBS, GLOBES AND GUARDS WHERE MISSING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
REPAIR EMERGENCY LIGHT IN PORT ENGINEROOM (DEAD END WIRE)_x001C_ _x001C_
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Engineering
Issued 13 April 1995
Resolved
Properly repair port main propulsion engine gear box. Vsl required to oper-ate with one add'l crew member assigned the responsibility of switching thegearbox to neutral. Vsl required to establish comms between the operator & this individual at all times while operating. Passenger count reduced by 1.
Condition: Unknown
Due 21 April 1995
Resolved 4 May 1995
Construction/Loadline
Issued 13 February 1995
Resolved
MAKE ALL FIT-UPS AVAILABLE FOR CG INSPECTION PRIOR TO WELDING.
Condition: Unknown
Due 15 April 1995
Resolved 27 April 1995
Construction/Loadline
Issued 13 February 1995
Resolved
CONDUCT NDT OF ALL REPAIR WELDS AS DEEMED NECESSARY BY THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1995
Resolved 27 April 1995
Construction/Loadline
Issued 13 February 1995
Resolved
SUBMIT REPAIR PROPOSAL FOR ALL HULL, STRUCTURAL AND EQUIPMENT DAMAGE RESULTED FROM GROUNDING. INCLUDE WELDER QUALS AND WELD PROCEDURES.
Condition: Unknown
Due 15 April 1995
Resolved 27 April 1995
Lifesaving
Issued 13 February 1995
Resolved
GAS FREE ALL BALLAST TANKS AND MAKE AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 15 February 1995
Resolved 27 April 1995
Construction/Loadline
Issued 6 June 1994
Resolved
MONITOR STRUCTURAL CONDITION OF VESSEL IN AREA OF REPAIR (AT PORT AFT STRUTENGINE ROOM/FUEL TANK/KNUCKLE) AND THE SAME AREA OF STARBOARD SIDE. THIS IS TO BE CONDUCTED PRIOR TO EACH VOYAGE AND LOGGED. ANY DISCREPENCIES SHALL BE REPORTED IMMEDIATELY TO THE COGNIZANT OCMI.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Construction/Loadline
Issued 6 June 1994
Resolved
GAS FREE STARBOARD FUEL TANK AND MAKE AVAILABLE FOR INSPECTION OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Construction/Loadline
Issued 6 June 1994
Resolved
SUBMIT PLANS FOR APPROVAL FOR REPAIRS TO PORT AFT STRUT, IN WAY OF FUEL TANK/ENGINE ROOM BULKHEAD AND THE SIDESHELL, AT THE OUTER 'KNUCKLE'. THESEPLANS SHOULD ADDRESS ALSO OTHER CRACKING IN FUEL TANK FRAMES AND SWASH BULKHEAD, AND EVALUATE DESIGN TO PREVENT FURTHER CRACKING.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Construction/Loadline
Issued 6 June 1994
Resolved
COMPLETE REPAIRS TO AREAS OF CRACKING AT PORT ENGINE ROOM/FUEL TANK BULKHEAD PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Electrical
Issued 11 March 1994
Resolved
REMOVE DEAD END CABLES OUTSIDE AFT CABIN DOORS, PORT AND STARBOARD, OR PROPERLY INSTALL LIGHTS.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Accommodation/Occupational Safety
Issued 11 March 1994
Resolved
REMOVE HOTBOX AND AIR COMPRESSOR STOWED ON STERN.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Documentation
Issued 11 March 1994
Resolved
PROVIDE EVIDENCE OF HAVING A CURRENT CERTIFICATE OF DOCUMENTATION FOR LESS THAN 100 GROSS TONS PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Documentation
Issued 11 March 1994
Resolved
PROVIDE STABILITY LETTER PRIOR TO OPERATING VESSEL
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Construction/Loadline
Issued 11 March 1994
Resolved
PROVIDE DECK PLATING IN AIR CONDITIONING ROOM.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Construction/Loadline
Issued 11 March 1994
Resolved
PROVE PROPER OPERATION OF AUTOMATIC BALLASTING SYSTEM AND DRAFT INDICATING SYSTEM.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Electrical
Issued 11 March 1994
Resolved
IN PORT AND STARBOARD ENGINE ROOMS, REMOVE ALL DEAD END CABLES.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
IN PORT AND STARBOARD ENGINE ROOM FIDDLEYS, PROVIDE CHAFING BLOCKS WHERE CABLES PASS THROUGH UPPER INBOARD BULKHEAD.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
IN PORT ENGINE ROOM, PROVIDE BLANK FOR OPEN FUSE SLOT IN ELECTRICAL PANEL P-2.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
IN PORT AND STARBOARD ENGINE ROOMS, PROPERLY SECURE WIRES/CABLES IN RACES WITH METAL TIE DOWNS.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
PROPERLY SECURE WIRES RUNNING FROM ELECTRICAL PANEL D-2 IN GALLEY SPACE.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
DETERMINE REASON FOR NOT ACTIVATING 'RANGE FAN' BREAKER IN PANEL D-2, AND CORRECT AS NECESSARY.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
PROVIDE MULTI CABLE TRANSIT (MCT) BOXES IN AIR CONDITIONING ROOM, PORT AND STARBOARD SIDES.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
IN PORT AND STARBOARD ENGINE ROOMS, PROVIDE MULTI CABLE TRANSIT BLOCKS AT TOP OF FIDDLEY, FORE AND AFT AS NECESSARY.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
REMOVE EXTENSION CORDS WIRED TO EXTERNAL STRIP LIGHTING IN THE AIR CONDITIONING ROOM, PORT AND STARBOARD SIDES.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
REMOVE DEAD END WIRES IN AIR CONDITIONING ROOM.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
PROPERLY SECURE WIRES AND CABLES IN AIR CONDITIONING ROOM WITH METAL TIE DOWNS.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 11 March 1994
Resolved
LABEL FUSES IN PANEL D-1 IN THE AIR CONDITIONING ROOM.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994