Records from 2005 to 2026. Most recent: inspection, 7 May 2026.
Inspection history · 27
7 May 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8368759
9 October 2025
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8250213
24 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087283
4 March 2025
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8082117
10 September 2024
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8000143
11 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7875752
10 August 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7675337
9 June 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7671076
25 April 2023
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7659289
21 October 2022
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7581598
11 August 2022
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7500622
7 June 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7470850
14 April 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7424414
1 April 2022
DAPI Audit · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7411245
3 August 2021
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7276332
20 May 2021
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7200820
30 April 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7175099
11 June 2020
Annual Inspection · MTSA Verification · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6966099
3 May 2019
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6676066
3 January 2019
Drydock Exam · Internal Structural Exam · Construction Oversight · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6601047
27 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6524308
27 April 2018
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6388054
24 October 2017
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6294795
21 April 2017
COI Inspection · DAPI Audit · Examination of Repairs · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6119157
14 April 2017
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6119144
22 April 2016
Administrative Inspection · MTSA Verification · Plan Review (Other than "T") · Annual Inspection · DAPI Audit · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5853498
10 March 2016
Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5831457
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2026
Resolved
The buoyant apparatus must have a floating waterlight approved under approval series 161.010. Prove proper operation of waterlights for the BAs that were not functioning.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 19 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2026
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Prove proper operation of three fire hose nozzels that were leaking excessively as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 15 July 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 May 2026
Resolved
A vessel of more than 65 feet in length carrying more than
600 passengers must have an emergency lighting system that complies with Part 112 in subchapter J of this chapter. Provide "E"s on all emergency lights that are missing/painted over.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 19 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Properly secure and provide adequate cover to open junction box in steering compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 18 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026
Resolved
Center light is out in the steering compartment, prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 18 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2026
Resolved
Each life jacket must be approved in accordance with 46 CFR 160.002, 160.005, or 160.055. Replace retro tape on the child lifejackets as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 18 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2026
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Provide donning placard for the horse shoe type lifejackets as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 18 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026
Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Black battery box in the engine room are not mounted, mount battery boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 15 July 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 April 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Provide an updated chart.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2025
Resolved 8 May 2025
Resolution: New paper charts onboard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 April 2025
Resolved
Penetrations in fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and/or smoke. Seal the open cable penetration on the 01 deck stbd cabin door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2025
Resolved 8 May 2025
Resolution: plugged.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 April 2025
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Secure the leak at fire station #4 stem valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2025
Resolved 1 May 2025
Resolution: Valve stem renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2025
Resolved
Tank Room and E-gen: Secure CO2 tanks.
Action required: 705 - Other - as specified
Due 30 May 2025
Resolved 21 March 2025
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 4 March 2025
Resolved
Crew Berthing: Install guards on overhead lighting
Action required: 705 - Other - as specified
Due 30 May 2025
Resolved 21 March 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 4 March 2025
Resolved
Crew Berthing: Clean and operate the emergency escape scuttle in the presence of a Marine Inspector.
Action required: 705 - Other - as specified
Due 30 May 2025
Resolved 21 March 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 March 2025
Resolved
Fore Peak: Clean and operate the reach rod in the presence of the Marine Inspector.
Action required: 705 - Other - as specified
Due 30 May 2025
Resolved 21 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 4 March 2025
Resolved
Car Deck: Repair damaged ventilation duct, port side
Action required: 705 - Other - as specified
Due 30 May 2025
Resolved 21 March 2025
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 March 2025
Resolved
02 Deck: Renew the stbd aft longitudinal overhead frame to good metal.
Action required: 705 - Other - as specified
Due 30 May 2025
Resolved 21 March 2025
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 April 2022
Resolved
Conduct man overboard in the presence of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2022
Resolution: Drill conducted
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 April 2022
Resolved
Conduct abandon ship drill in the presence of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2022
Resolution: Drill conducted
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 April 2022
Resolved
Conduct fire fighting drill in the presence of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2022
Resolution: Drill conducted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2022
Resolved
Tested engine room bilge suction 1 of 3. The port side bilge and emergency bilge suction unable to test due to oily bilge. Prove proper operation bilge suction.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2022
Resolved 14 April 2022
Resolution: Bilges tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 April 2022
Resolved
Resubmit DVTP/OFA for Cummins engines to MSC for modification to current approved procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2022
Resolved 7 June 2022
Resolution: MSC Approval ltr E2-2201753 dtd 7Jun22
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 May 2021
Resolved
Replace bilge suction strainer in the engineroom. Strainer is wasted through on the bottom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 17 June 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2021
Resolved
Remove or replace mattresses in crew berthing with an approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 17 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 May 2021
Resolved
Make engineroom emergency escape hatch watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 17 June 2021
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 May 2021
Resolved
Prove proper operation of PA system on emergency power.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 16 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2020
Resolved
Propulsion machinery must be suitable for propulsion requirements of the hull in which it is installed. Center engine cannot be controlled from pilot house. prove proper operation of pilot house engine control to satisfaction of Marine Inspector. Vessel allowed to carry passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2020
Resolved 12 June 2020
Resolution: Twin Disc EC-300 control lever replaced. Op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2019
Resolved
The #3 void bilge suction union was cracked causing the system to not pull a suction from the compartment.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019
Resolved
The embarkation lights bulbs were blown and replaced.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019
Resolved
The emergency light on the starboard side catwalk was not working and repaird.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
08 - Alarms › N/A - No Subsystem › General alarm
Issued 3 May 2019
Resolved
The general alarm bell on the 02 level above the stairtower did not operate when tested.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 May 2019
Resolved
Remove dead ended or enclose in electrical boxes wires in the machinery space from the recent machinery conversion.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2019
Resolved
The forepeak bilge suction line was clogged not allowing the the system to operate as designed.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: No static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 24 September 2018
Communications › Alarms/Indicators › General Alarm
Issued 27 April 2018
Resolved
Properly mark general alarm in engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 22 May 2018
Resolution: Properly marked general alarm in engine room.
Construction/Loadline › Structures › Scuttle
Issued 27 April 2018
Resolved
install retention chains on all deck scuttles.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 22 May 2018
Resolution: installed retention chains on all deck scuttles.
Construction/Loadline › Structures › Door
Issued 27 April 2018
Resolved
Properly repair 01 deck forward starboard door dog.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 24 July 2018
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 27 April 2018
Resolved
Replace wire and prove operation of emergency shutdown seleniod of bow-thruster prime mover.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 27 April 2018
Resolution: Replaced wire and proved operation of emergency shutdown seleniod of bow-thruster prime mover.
Communications › Alarms/Indicators › General Alarm
Issued 27 April 2018
Resolved
Repair bell in accomodation space gereralalarm.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 27 April 2018
Resolution: Repaired bell in general alarm.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 12 May 2017
Resolved
Provide drip pan to prevent gear oil leaking into bow thruster space in way of pump.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 17 May 2017
Resolution: Provided drip pan to prevent gear oil leaking into bow thruster space in way of pump.
Engineering › Thrusters › Pump
Issued 21 April 2017
Resolved
make permanent repairs to gear oil leak iwo bow thruster pump.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 24 October 2017
Stability › Incline Test › General
Issued 22 April 2016
Resolved
Resubmit calculations to the USCG Marine Safety Center (MSC) to include the removal of the two seats for the IBA installation.
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 3 May 2016
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 31 March 2016
Resolved
Company rep still needs to submit drawings/plans for the movement of the fuel lines and return fuel lines on the new generators.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 22 April 2016