MAURY USCG vessel records Sign in
← All vessels

BOW MAASSTROOM

BOW MAASSTROOM is a 1983 tank ship. The Coast Guard has recorded 80 inspections since 1984, most recently in May 2007, along with 47 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 1984 to 2007. Most recent: inspection, 22 May 2007.

Built
1983
Last inspected
22 May 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8106927 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
229573
Flag
SINGAPORE
—
Maury page id
psix-229573

Inspections, by type

…with no type recorded54
…past their stated due date2
Years with a record 23 calendar years (1984–2007)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it38039 - Dead Weight, Ton
48882 - Displacement, Ton
12526 - Convention (Subpart B), Net Ton
24794 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KIRBY 10760 Tank Barge · MISLE 47997 · 4 January 2002 · activity 1481775MARY HOPE II Towing Vessel · MISLE 120762 · 4 January 2002 · activity 1481775

Inspection history · 80

22 May 2007 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2939270
16 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2932800
10 May 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2926659
14 May 2006 ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2648357
23 March 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2318097
21 August 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2172188
21 July 2004 COC-CHEM Renew · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2140950
16 December 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1966559
15 December 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1965453
10 December 2003 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1962044
14 August 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1879577
4 August 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1866043
11 April 2002 Security Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1604185
9 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1602934
2 April 2002 In-Service Inspection · Certificate of Compliance
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1600141
1 April 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1598780
5 January 2002 In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1475792
4 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1481775
15 October 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294701
14 June 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 291051
2 April 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 288613
21 March 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 275989
21 March 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 816376
4 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 428468
4 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 797875
15 January 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 424525
17 December 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 198490
17 December 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754324
26 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 415256
30 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 414309
30 March 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470708
12 August 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 406689
14 July 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 405785
21 June 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 404702
21 June 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1114774
5 February 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 191899
5 February 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754388
29 October 1996 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 396786
9 April 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 389891
2 April 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 389733
8 January 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 386540
27 June 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380031
30 March 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 376776
7 November 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 482971
19 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 520207
17 March 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1414268
8 March 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 518074
8 March 1994 Tank Vessel Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1442114
4 December 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 847724
19 November 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 511494
5 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826702
21 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 358383
9 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355726
8 January 1993 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1139309
12 December 1992 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1159830
9 July 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 443203
22 February 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348917
21 February 1992 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353358
18 February 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348780
25 September 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 346048
21 May 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 535145
20 February 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 342012
10 November 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 340218
10 November 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 921305
8 August 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 474820
8 August 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 511866
16 January 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 334671
16 January 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1228495
27 August 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 536003
10 October 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 326072
10 October 1988 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1196712
20 June 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 522472
12 February 1988 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1020943
24 July 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 535844
22 October 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 312138
22 October 1986 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1321643
22 August 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 311061
22 January 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 306612
22 January 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 996756
6 November 1984 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 476028

Deficiency record · 47

Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 22 May 2007 No resolution recorded
The vessel crew was not familiar with updated changes to the shis Safety Management System (SMS). This was evident by the [name withheld] not being familiar with the updated SMS checklists for cargo operations. The master shall review the updated SMS with the vessels crew and ensure all guidance and checklists are utilized. (ISM Code Reg. 6)
Action required: 705 - Other - as specified
Due 22 June 2007 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 10 May 2007 No resolution recorded
Water closet in hospital accomadation did not have hot water.
Action required: 705 - Other - as specified
Due 10 June 2007 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 May 2007 Resolved
Cargo piping on deck located outboard of deepwell cargo pump head for #1 port and #5 port cargo tanks leaking cargo into portable containment apparatus. Make sufficient repairs to stop the leakage of cargo prior to the handling of any hazardous cargo to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 16 May 2007
Resolution: Repairs were made by crew dismantling damaged valves for repair and overhaul. Subsequent to replacement of valve seals, gaskets, etc. the repaired valve was placed back in service with all found in order by DNV Surveyor.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 May 2007 Resolved
The color of the deck line was painted the same color as the hull (orange-red).
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: Loadline and deck markings on both port and starboard sides have been repainted with a contrasting color (White). DNV Surveyor found markings to be satisfactory.
Lifesaving › Lifeboat › Markings
Issued 10 May 2007 Resolved
Lifeboats do not have numbers (1 and 2 that identifies port and starboard) visable from above.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: Both port and starboard lifeboats have been marked IAW SOLAS/LSA. Identification markings are visible from above. DNV Surveyor found condition to be in order.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 10 May 2007 Resolved
Port side lifeboat was short 61,500 kJ of food rations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2007
Resolution: Master called agent, and agent delivered the rations to the vessel before the PSC exam was completed.
Deck/Cargo › Inert Gas System › Venting System
Issued 10 May 2007 Resolved
Inert gas sampling room located above emergency generator room aft superstructure, has severe corrosion in drain pipe and deck. Drain pipes in emergency generator room also leaking, causing the same result.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 16 May 2007
Resolution: Space located above and drainage piping inside Emergency Generator Room were repaired by removing/replacing wasted areas. No leakage evident in space. Repairs were to the satisfaction of DNV Surveyor.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 May 2007 Resolved
The last 1 meter of vapor piping before the vessel vapor connection is painted incorrectly (yellow/red/yellow). Refer to 46CFR39.20-1(d) for how the piping should be painted.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: Last 1 meter of vapor piping was repainted with proper markings to the satisfaction of DNV Surveyor.
Deck/Cargo › Cargo Heating › General
Issued 10 May 2007 Resolved
Steam piping system located on deck has numerous leaks throughout system.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 16 May 2007
Resolution: Leaks in steam piping were identified and repaired by cladd welding. Vessel crew conducted pressure test of repaired piping at 7 bars. DNV Surveyor found repairs to be in order.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 May 2007 Resolved
Ladder aft of accomodation between 1 and 2 deck (bottom step) is wasted.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 16 May 2007
Resolution: Bottom step replaced to the satisfaction of DNV Surveyor
Lifesaving › Lifeboat Equipment › Food Ration
Issued 21 July 2004 Resolved
Several food packets (35) have been holed and are no longer air tight (LSA Code 4.4.8.12). Replace food at least 35 packets and sent receipt for food purchase to USCG.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 23 July 2004
Resolution: Received receipt from vessel showing they purchased more lifeboat food.
Construction/Loadline › Hull
Issued 5 January 2002 Resolved
Vessel involved in a collision while anchored and sustained damage to hull IWO portside #1 DBBT and two stringers. Correct to the satisfaction of the Certificate Issuing Authority (DNV). LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2002
Resolved 8 January 2002
Resolution: A permanent repair to the side shell and its supporting structure has been made with approved procedures, personnel and material.
Deck/Cargo
Issued 21 March 2000 Resolved
REPAIR AND PROVE OPERATION OF THE ODME. VESSEL TANK WASHINGS SHALL REMAIN ONBOARD UNTIL REPAIRED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 30 March 1998 Resolved
THE VESSEL STB LIFEBOAT SPRINKLER SYSTEM WAS NOT OPERATING PROPERLY._x001C_ THE DEFICIENCY REMAINS OUTSTANDING.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Deck/Cargo
Issued 21 June 1997 Resolved
PROVIDE A COPY OF THE CERTIFICATION THAT THE HIGH VELOCITY PRESSURE VACUUM VALVES FOR EACH CARGO TANK WERE SATISFACTORILY TESTED PRIOR TO RETURN TO THE U.S. FROM OVERSEAS.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Lifesaving
Issued 21 June 1997 Resolved
HAVE CLASS INSPECT THE STARBOARD LIFEBOAT RELEASING ARRANGEMENT AND BRAKE TO ENSURE THAT BOTH ARE FULLY OPERATIONAL AS DESIGNED PRIOR TO RETURN TO THE U.S. FROM OVERSEAS.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Navigation
Issued 21 June 1997 Resolved
REPAIR VESSEL'S ARPA PRIOR TO DEPARTURE.
Condition: Unknown
Due 22 June 1997
Resolved 23 June 1997
Deck/Cargo
Issued 21 June 1997 Resolved
PROVE PROPER OPERATION OF THE HIGH LEVEL AND OVERFILL ALARMS FOR THE CARGO TANKS TO THE SATISFACTION OF CLASS PRIOR TO LOADING CARGO IN THE U.S.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Deck/Cargo
Issued 21 June 1997 Resolved
HAVE CLASS INSPECT LEAK IN HYDRAULIC PIPING FOR CARGO PUMPS ON THIRD DECK LEVEL OF BALLAST PUMP ROOM AND MAKE RECOMMENDATIONS FOR REPAIR PRIOR TO RETURNING TO THE U.S. FROM OVERSEAS.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Lifesaving
Issued 2 April 1996 Resolved
PROVIDE MAXIMUM TRANSFER RATE FOR EACH CARGO CARRIED AND HANDLED BY VAPOR RECOVERY SYSTEM PRIOR TO RETURN TO US. SEE 49CFR39.30-1 B 1
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Deck/Cargo
Issued 2 April 1996 Resolved
PROVE PROPER OPERATION OF IGS SYSTEM.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Deck/Cargo
Issued 27 June 1995 Resolved
PROVIDE PORTABLE SMALL DISCHARGE CONTAINMENT OF SUITABLE CAPACITY FOR CARGOHOSE CONNECTION. VESSEL WAS LOADING "ON TOP" VIA BUTTERWORTH PORT ON CARGOTANK DBYPASSING MANIFOLD CONTAINMENT PAN. INCOMPATIBLE CARGO RESIDUE IN MANIFOLD LINE.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Deck/Cargo
Issued 30 March 1995 Resolved
DEVELOP A SUITABLE SYSTEM FOR TESTING VAPOR PRESSURE ALARMS. PROVE PROPER OPERATION OF ALARMS TO USCG WITH THIS SYSTEM.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Documentation
Issued 30 March 1995 Resolved
PROVIDE EVIDENCE OF TESTING FOR THE P/V VALVES IN REGARDS TO SET POINTS. RELEASE POINTS SHOULD BE RECORDED.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Documentation
Issued 30 March 1995 Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR BOTH CARGO TRANSFER AND VAPOR COLLECTION SYSTEM OPERATIONS IN ACCORDANCE WITH 33 CFR 155.750.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Documentation
Issued 30 March 1995 Resolved
PROVIDE EVIDENCE OF TRAINING FOR THE PERSON IN CHARGE OF THE TRANSFER SYSTEM IN REGARDS TO THIS VESSEL VCS SYSTEM AS REQUIRED BY 46 CFR 39.10-11.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Deck/Cargo
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE EVIDENCE OF TESTING OF VAPOR PRESSURE ALARMS IN REGARDS TO +/- 10% ACCURACY.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 30 March 1995 Resolved
PROIR TO NEXT U.S. VOYAGE, INCLUDE THE ABOVE MENTIONED PRESSURE DROP CALCULATIONS REQUIRED IN ITEM #9 IN THE OIL TRANSFER PROCEDURES AS REQUIREDBY 46 CFR 39.30-1(b)(3).
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Deck/Cargo
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PERMANENTLY INSTALL 1" STUD ON STBD SIDE VAPOR HEADER.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Navigation
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, INSTALL AUDIBLE ALARM ON BRIDGE FOR STEERING CONTROL SYSTEM ELECTRICAL FAILURE, AS PER SOLAS II-I/29, TO SATISFACTION OFCLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Navigation
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, INSTALL AUDIBLE & VISUAL ALARM ON BRIDGE FOR STEERING GEAR HYDRAULIC FLUID LOW LEVEL TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY SURVEYOR'S REPORT.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Fire Fighting
Issued 30 March 1995 Resolved
PRIOR TO CARGO OPERATIONS, PROVIDE DOCUMENTATION THAT FIRE FIGHTING FOAM ISPOLAR SOLVENT OR PROVIDE POLAR SOLVENT ONBOARD.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Fire Fighting
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE MEANS OF CLOSURE FOR PAINT LOCKER VENTILATION WHERE PAINT LOCKER IS PROTECTED BY CO2.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Construction/Loadline
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE MECHANICAL MEANS OF CLOSURE FOR FUEL ANDLUBE OIL DISCHARGE CONTAINMENT DRAINS WHERE CURRENTLY CLOSED BY WOODEN STOPPERS.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 30 March 1995 Resolved
INDICATE IN THE OIL TRANSFER PROCEDURES THE PRE-TRANSFER EQUIPMENT INSPECTION REQUIREMENTS.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Deck/Cargo
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE INDEPENDENT AUDIBLE ALARM FOR VESSEL'S HIGH LEVEL AND OVERFLOW ALARM.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Deck/Cargo
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE VESSEL'S VAPOR COLLECTION DESIGN MAX PRESSURE.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Deck/Cargo
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE VESSEL'S VAPOR COLLECTION DESIGN MAX VACUUM.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Deck/Cargo
Issued 30 March 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE PRESSURE DROP CALCULATIONS FOR ALL CARGOES AUTHORIZED FOR VAPOR COLLECTION. THIS SHALL BE AT MAX TRANSFER RATES AND AT LESSER TRANSFER RATES AS REQUIRED BY 46 CFR 39.30-1(b).
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 12 December 1992 Resolved
IGS MANUAL AND OIL TRANSFER PROCEDURES MUST CONTAIN VAPOR CONTROL SYSTEM OPERATION PROCEDURES.
Condition: Unknown
Due 12 December 1992
Resolved 12 December 1992
Deck/Cargo
Issued 12 December 1992 Resolved
REPLACE OR REPAIR THE STAINLESS STEEL STRIPPING PIPING AND THE EXPANSION JOINT AT THE #2 PORT AFT CARGO TANK WHERE THEY ARE BENT.
Condition: Unknown
Due 12 December 1992
Resolved 12 December 1992
Documentation
Issued 12 December 1992 Resolved
OIL TRANSFER PROCEDURES NEED TO INCLUDE OIL SPILL CONTINGENCY PLANS AND PERSONS INVOLVED IN BUNKERING AND THEIR DUTIES.
Condition: Unknown
Due 12 December 1992
Resolved 12 December 1992
Deck/Cargo
Issued 21 February 1992 Resolved
Demonstrate proper operation of the IGS system to the satisfaction of the cognizant OCMI prior to transfer when required for cargo in U.S. waters._x001C_
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Construction/Loadline
Issued 21 February 1992 Resolved
Renew or repair flame screens on #3 port wing ballast tank prior to return to U.S. waters._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Deck/Cargo
Issued 10 November 1990 Resolved
VESSEL DID NOT HAVE SIGN AT GANGWAY THAT MEETS 46 CFR 153.1060 "BENZENE. CANCER HAZARD IN THIS AREA. PROTECTION EQUIPMENT MAY BE REQUIRED. AU- THORIZED PERSONNEL ONLY.
Condition: Unknown
Due 10 November 1990
Resolved 10 November 1990
Deck/Cargo
Issued 10 November 1990 Resolved
HIGH LEVEL ALARM REQUIRED BY 46 CFR 153.409 DOES NOT SOUND ON THE OPEN DECK.
Condition: Unknown
Due 10 November 1990
Resolved 10 November 1990
Electrical
Issued 10 November 1990 Resolved
NON-CONDUCTIVE MAT MISSING FROM IN FRONT OF THE EMERGENCY GENERATOR PANEL IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 10 November 1990
Resolved 10 November 1990

Ownership record