MAURY USCG vessel records
← All vessels

MARY HOPE II

Built
1973
Last inspected
24 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 24 October 2025
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1995–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3837
120762
Flag
UNITED STATES
Maury page id
psix-120762

Documentation record

Registered dimensions (L × B × D)56.5 ft × 20.0 ft × 7.3 ft
Registered tonnagegross 76 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSNEED SHIPBUILDING INC · ORANGE, TX, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTSMOUTH, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Net Ton
76 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 31 inspections, each with its date, unit and type; 54 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 31

24 October 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8253515
6 August 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8203548
3 October 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8013847
23 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7985376
11 January 2024 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7848489
13 December 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7838266
16 November 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7825791
11 July 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7739808
17 March 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7660483
29 September 2022 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7566533
19 April 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7433891
11 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7222493
21 August 2020 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7039269
23 April 2020 Initial Certification · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6942903
26 September 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6822484
26 September 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6837306
19 September 2013 Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4718703
7 February 2013 Deficiency Check · Administration
Physical examination · USCG East District (dp) · USCG East District (CGD-E) · Activity 4529866
29 January 2009 Annual Inspection · Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3403820
23 January 2009 Administration
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3400439
22 January 2009 Type not recorded
No type recorded · Station Portsmouth · USCG East District (CGD-E) · Activity 3398531
4 January 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3124705
13 June 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2960200
9 October 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2511347
4 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1481775
8 March 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 114866
1 March 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 87900
26 January 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 6115
5 May 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 196228
5 May 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765791
24 July 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 511981

Deficiency record · 54

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 August 2025 Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. Vessel's COI expired 15JUL25. //46 CFR 136.200(a)// 705 - prior to towing operations
Action required: 705 - Other - as specified
Resolved 12 August 2025
Resolution: Cleared when Temp COI was issued at completion of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 August 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port SSDG has signs of oil leakage IVO of the turbo and under air filter. 46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 6 September 2024
Resolution: Area cleaned, connection points tightened, and no leaks witnessed during operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 August 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. STBD SSDG has signs of oil leakage IVO of the turbo and under air filter. 46CFR143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 6 September 2024
Resolution: Area cleaned, connection points tightened, and no leaks witnessed during operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 August 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Primary installed bilge pump is non operational. 46CFR143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 6 September 2024
Resolution: Crew stated pump did not run due to being on shore power during inspection. Witnessed operational test of primary bilge pump from forepeak and engine while on generator power.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 23 August 2024 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel has no records of engine alarm set points being tested. 46 CFR 143.245(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 6 September 2024
Resolution: Reviewed objective evidence on board that crew tested alarm set points with Western Branch Diesel present for MDEs and SSDGs.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 23 August 2024 Resolved
In general.-The responsible entity of a vessel shall report to the Commandant any complaint or incident of harassment, sexual harassment, or sexual assault in violation of employer policy or law, of which such entity is made aware. Vessel was unaware of CG reporting requirements and guidance. 46 USC 10104
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 6 September 2024
Resolution: SASH CG reporting requirements posted in common areas of vessel, crew provided training, and company SMS manual includes section for CG reporting.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 August 2024 Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion suits were found unmarked as required, corrected on the spot. 46 CFR 199.70(c)(3)
Action required: 10 - Deficiency Rectified
Due 6 September 2024
Resolved 23 August 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 December 2023 Resolved
The system is installed, tested, and maintained in accordance with the manufacturer's design manual. MI observed a toggle switch on the Fire Detection Panel installed allowing the crew to manually turn the system off that is not authorized IAW the manufacturer's manual. 46 CFR 142.330(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2024
Resolved 18 January 2024
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 December 2023 Resolved
The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician. Vessel's current installation certificate is invalid due to modification/alteration made subsequent to the date of original survey in 2012. 46CFR142.330(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2024
Resolved 10 January 2024
Resolution: Crew removed the toggle switch and had a professional engineer come and recertify the system. all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 December 2023 Resolved
Each towing vessel must be operated in compliance with the Maritime Transportation Security Act of 2002 and 33 CFR parts 101 and 104, as applicable. Vessel does not have a designated VSO or CSO and has not completed drills, audits, exercises. Vessel is restricted in conducting operations involving red flag barges. 46 CFR 140.660
Action required: 705 - Other - as specified
Resolved 9 January 2024
Resolution: Vessel received letter from MSC withdrawing all vessels listed on the VSP.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 13 December 2023 Resolved
A navigation assessment entry must be recorded in the TVR or official log. The entry must include the date and time of the assessment, the name of the individual making the assessment, and the starting and ending points of the voyage or trip that the assessment covers. Vessel’s navigation assessments was found missing starting and ending points. 46 CFR 140.635(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2024
Resolution: Vessel has been providing appropriate data on navigation assessments, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 December 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire shock hazards. MI observed open hole in electrical panel (approx. 2” x 2”), aft centerline engine room. 46 CFR 143.400(a). 46 CFR 143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Crew screwed a cover over the opening, all sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 13 December 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual. All alcohol testing devices used to meet the requirements of this part must be be currently listed on either the Conforming Products List (CPL) titled "Modal Specifications for Devices To Measure Alcohol in Bodily Fluids", which are published periodically in the Federal Register by National Highway Administration (NHTSA). The marine employer must have a sufficient number of urine-specimen collection and shipping kits meeting the requirements of 49 CFR 40 that are readily accessible for use. Vessel could not provide any drug or alcohol testing kits. 46CFR4.06-15(a)(1). 46CFR4.06-15(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Vessel was able to provide sufficient # of drug and alcohol testing kits for the amount of people the vessel is certificated for.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 December 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. MI found exposed wires next to condensate drain pump in void located under pilot house. 46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Crew installed wire nuts, all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 December 2023 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel could not provide evidence of any documentation of tests performed. 46 CFR 143.245(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Vessel completed appropriate tests and logged in their vessel log book, all sat.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 13 December 2023 Resolved
Any towing vessel with alternating watches or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. Vessel could not provide any list of duties for crewmembers or a station bill. 46 CFR 140.405 (b). 46 CFR 140.405 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Vessel printed out a station bill and taped it in the galley and at the operating station, all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 December 2023 Resolved
Records of drills and instruction must be maintained in the TVR or official logbook. The record must include, the date of the drill and instruction, a description of the drill scenario and instruction topics, the personnel involved. Vessel could not provide any documentation of drills or training. 46 CFR 140.420 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Vessel completed drills and logged in official logbook, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 December 2023 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI observed wire on stbd MDE starting battery degraded and exposing copper wire through the insulation. 46 CFR 143.400 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Crew replaced the insulation of hte cable, all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 December 2023 Resolved
All crewmembers must be provided with health and safety information and training. Refresher training must be repeated annually and may be conducted over time in modules covering specific topics. Refresher training may be less comprehensive, provided that the information presented is sufficient to provide employees with continued understanding of workplace hazards. The refresher training of persons subject to this subpart must include the information and training prescribed in this section. All training required in this section must be documented in owner or managing operators’ records. Vessel could not provide any documented training. 46 CFR 140.515
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Vessel rep supplied documentation that all crew received refresher training, created new binder just for the health and safety training with a tab for each crew member.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 December 2023 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI observed hot starts electrical boxes on both MDE’s not properly secured and hanging. 46 CFR 143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: crew remounted and secured the hot starts electrical boxes for each engine, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 December 2023 Resolved
Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least .5” high with “DISTRESS SIGNALS”. MI observed portable watertight container not marked. 46 CFR 141.375 (e)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Crew labeled container with Distress Signals, all sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 13 December 2023 Resolved
Each towing vessel must be operated in compliance with parts 151, 155, and 156, of 33 CFR, as applicable. Vessel does not have a garbage management plan. 46 CFR 140.655
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Vessel has a garbage plan posted in the galley and engine room, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2023 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Wheeled 160 B Semi-Portable fire extinguisher was not secured to the vessel. 46 CFR 142.230(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 10 January 2024
Resolution: Vessel installed shackles to secure the semi-portable, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 December 2023 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. MI observed multiple openings in the stbd aft distribution panel in E/R. 46 CFR 143.400(g)
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: O/O installed blanks on all openings.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 December 2023 Resolved
Each towing vessel must be equipped with navigation lights, shapes and sound signals in accordance with the COLREGS or 33 CFR part 84 as appropriate to its area of operation. Vessel had several navigation lights extinguished. 46 CFR 140.720
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: O/O replaced bulbs, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 December 2023 Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel’s lifesaving and fire suppression and detection equipment complies with the applicable requirements of parts 141 and 142 of this subchapter and is in good working order. Smoke detector in galley did not have batteries installed and inoperable. Smoke detector in upper level berthing was inoperable. 46 CFR 140.650
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: O/O replaced batteries in both smoke detectors, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 December 2023 Resolved
Survival craft must be stowed in accordance with the requirements of 199.130 of this chapter, as far as is practicable on existing towing vessels. Vessel’s hydrostatic release unit was not installed correctly. 46 CFR 141.310
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: O/O installed hydrostatic release correctly, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2023 Resolved
Lifebuoys must have the following attachments and fittings: at least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Port and stbd floating electric water light had improper batteries installed. 46 CFR 141.360(c)(2)
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: O/O replaced batteries with approved battery type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2023 Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 3’ in length but no more than 6’, securing the water light around the body of the lifebuoy. MI observed port floating electric water light’s lanyard sun damaged and degraded. 46 CFR 141.360 (c)(4)
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: O/O replaced port light lanyard with new lanyard, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2023 Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 3’ in length but no more than 6’, securing the water light around the body of the lifebuoy. MI observed stbd water light lanyard not secured around body of the lifebuoy. 46CFR141.360(c)(4)
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: O/O secured stbd light around body of lifebuoy, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 November 2023 Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. A towing vessel subject to this subchapter and choosing the Coast Guard inspection option must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel is overdue for annual inspection, invalidating vessel's COI. Rectify prior to conducting towing (pulling, pushing, or hauling alongside) operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2023
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 June 2021 Resolved
Due to vessels current life savings outfit vessels route is restricted to Lakes, Bays, and Sounds no more than 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 9 August 2021
Resolution: Vessel installed a ILR with SOLAS A pack for 6 persons. Found painter line not connected to HRU. Witnessed vessel Captain attach the painter to the HRU.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2021 Resolved
Prove proper operation of remote fuel shutoff valves.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2021
Resolution: Vessel reconnected emergency pull cables to valve handles and actuated both.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2021 Resolved
Prove proper operation of installed bilge.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2021
Resolution: Vessel pumped engineroom bilge using dedicated installed bilge pump discharging to a 55 gallon drum.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 June 2021 Resolved
Prove proper operation of fire detection panel. Batteries wont hold a charge. Provide servicing report.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2021
Resolution: New batteries purchased through Hiller and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2021 Resolved
Prove proper operation of portside ring life buoy light. Battery is expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2021
Resolution: New ring life buoy light installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2021 Resolved
Prove atmosphere in lazzerete is safe for workers. Provide report from Marine Chemist.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2021
Resolution: Marine Chemist certificate provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 June 2021 Resolved
Provide up-to-date charts for the intended voyage and publications (U.S. Coast Pilot, Coast Guard light list, tide-current tables).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2021
Resolution: New charts and pubs provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2021 Resolved
Provide proof essential systems and equipment has been tested and examined.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 17 June 2021
Resolution: List of essential systems and equipment provided with testing dates.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 June 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 17 June 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2021 Resolved
Prove compliance with Chemical Testing Program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 17 June 2021
Resolution: Company Chemical Testing Program was provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 June 2021 Resolved
Provide medical certificates for crew members with MMCs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 9 August 2021
Resolution: Vessel has new Captain with MMC and Medical Certificate.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 11 June 2021 Resolved
Provide Health & Safety Plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 17 June 2021
Resolution: Company provided Health & Safety Plan. In process of updating it to provide more vessel info.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 June 2021 Resolved
Provide proof of crew training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 17 June 2021
Resolution: Company provided deckhand and company training binders.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 June 2021 Resolved
Prove compass illuminates. Vessel restricted to daylight operations only.
Action required: 705 - Other - as specified
Resolved 17 June 2021
Resolution: New compass installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 June 2021 Resolved
Prove proper operation of stern light.
Action required: 10 - Deficiency Rectified
Due 11 June 2021
Resolved 11 June 2021
Resolution: Replaced bulb in kind. Tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2020 Resolved
All life jackets containers must be labled and available for those on watch. Vessel didnt have containers labeled or a jacket for bridge/nav watch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 21 August 2020
Resolution: Vessel labeled all lifejacket and immersion suit locations. Vessel also added 02 lifejackets and immersion suits to the pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 April 2020 Resolved
All immersion suit containers must be labled and available for those on watch. Vessel didnt have a suit on bridge for nav watch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 21 August 2020
Resolution: Vessel labeled all immersion suit locations and placed 02 immersion suits in the pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 April 2020 Resolved
All life jackets containers must be labled and available for those on watch. Vessel didnt have containers labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2020
Resolution: Vessel labeled all lifejacket locations and added 02 lifejackets to the pilot house.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 23 April 2020 Resolved
Vessel Compass not lit, need updated light list and charts, and coast pilot
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 21 August 2020
Resolution: Vessel compass light was fixed. Vessel acquired new charts and nautical publications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2020 Resolved
Portside life buoy didnt have water light properly installed and attached.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 21 August 2020
Resolution: Vessel has properly installed water light on the portside life buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2020 Resolved
40 BC not properly installed IVO paint locker
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2020
Resolution: Vessel acquire and installed 40 B:C IVO the paint locker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2020 Resolved
Alarm for the low lubricating oil unable to be demonstrated
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 21 August 2020
Resolution: Vessel is working directly with the Coast Guard to properly resolve low lube oil testing demonstration.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 April 2020 Resolved
Distribution panel IVO galley not properly blanked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 21 August 2020
Resolution: Vessel properly blanked distribution panel IVO the galley.

Ownership record