Records from 1985 to 2006. Most recent: inspection, 2 August 2006.
Inspection history · 29
2 August 2006
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2734337
14 February 2006
Deficiency Check · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2585221
23 November 2005
ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2540191
24 August 2005
NPV Safety Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2473210
14 October 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2221034
2 October 2004
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2210906
2 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2211911
3 March 2004
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2016984
1 May 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1611659
1 April 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 276432
8 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 114866
6 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 426160
29 January 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412047
15 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 408731
27 July 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 393712
9 May 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 677408
28 April 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 366540
17 August 1992
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 352664
10 February 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 652992
13 December 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 347656
4 December 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 347321
5 November 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 348767
21 February 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 335388
12 March 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 328754
6 October 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 524211
1 March 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 321576
23 June 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 309647
23 February 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 307232
3 May 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 301854
Operations/Management › Ballast Water Managment › Submission of Report
Issued 2 August 2006
Resolved
VSL did not submit BWM Report Prior to Arrival in Corpus Christi
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2006
Resolved 2 August 2006
Resolution: VSL was prompted to send BWM Report to NBIC prior to departure
Electrical › Lighting (service) › Switch
Issued 2 August 2006
No resolution recorded
Electronic Wire casing in port side of bosun hole in extrememely poor condition. Poses electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifebuoys › Stowage
Issued 2 August 2006
No resolution recorded
Life Buoys (2) in bosun hole not readily available.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Logs/Records › Garbage Recordkeeping
Issued 2 August 2006
No resolution recorded
Position of ship not recorded in garbage record book when conducting incineration activities
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 August 2006
No resolution recorded
Insufficient guardrails near MSD: 4.5 ft section missing from three railings.
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 2 August 2006
No resolution recorded
Galley Provision Cold Storage: Overhead and bulkhead paint peeling.
PWSA 33USC1223 / ILO147
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Logs/Records › Garbage Recordkeeping
Issued 2 August 2006
No resolution recorded
VSL did not have receipt for garbage discharge dated 27JUN06: deviated from garbage management plan.
Action required: 705 - Other - as specified
Lifesaving › Inflatable Liferafts › Servicing
Issued 2 August 2006
No resolution recorded
Forward life raft needs servicing - rubber gasket encasing has become loose
Action required: 705 - Other - as specified
Fire Fighting › Firemans Outfit › Quantity
Issued 2 August 2006
No resolution recorded
Chemical personal protective equipment not available on board for battery maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifeboat › Hull
Issued 2 August 2006
No resolution recorded
Crew conducted maintenance on fiberglass hull of Port and Starboard lifeboats - classification society should check and approve.
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Door
Issued 14 February 2006
Resolved
Accomodation space B-0 doors: Have numerous holes and missing closure devices. Class must inspect prior to departure Solas 74 II-2/51.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Construction/Loadline › Structures › Door
Issued 14 February 2006
Resolved
Accomodation space passageways: Have found numerous holes through bulkheads into compartments. Class must inspect prior to departure. Solas 74 II-2/51.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Construction/Loadline › Structures › Trunk
Issued 14 February 2006
Resolved
New cables have been run through cableway between first and fourth decks. Fire stop putty/cement is missing. Class must inspect prior to departure. Solas 74 II-2/51.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Construction/Loadline › Structures › Superstructure
Issued 14 February 2006
Resolved
Port light glass is missing from hospital space. Solas 74 Chapt 1/11.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Deck/Cargo › Mooring/Anchoring › Brake
Issued 14 February 2006
Resolved
Question reliability of brake linings on the port & stbd Anchor Windlass and aft Port Windlass. Solas 74 Chapt 1/11.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 14 February 2006
Resolved
Mast house #1 stbd side has been turned into a paint locker. Not identified on Fire Control Plan. Class must inspect prior to departure. Solas 74 II-2/4
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 February 2006
Resolved
Cut hole between engine room entrance and gym bulkhead. Class must inspect prior to departure. Solas 74 II-2/20.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 February 2006
Resolved
Provide nonslip surface or handrails in steering flat. Class must inspect prior to departure. Solas 74 81/83 AM II-1/29 13.2
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Engineering › Steering Gear System › Piping
Issued 14 February 2006
Resolved
Provide piping between fixed storage tank and steering system reservoir, Class must inspect prior to departure. Solas 74 81/83 AM II-1/29 3
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Lifesaving › Lifeboat › Canopy
Issued 14 February 2006
Resolved
Class to inspect and verify equipment for both lifeboats prior to vessel's departure. Solas 74 III/11.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Construction/Loadline › Structures › Superstructure
Issued 14 February 2006
Resolved
Unauthorized wire has been run through watertight bulkhead above door on boat deck stbd side for TV. Class must inspect prior to departure. Solas 74 II-2/44.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 February 2006
Resolved
Relocate lifejackets in the fwd bosn stores along with fire extinguisher and fire hose in aft steering flat which are not readily available. Class to make corrections to fire plan and inspect prior to departure. Solas 74 III-4C plus II-2/5(f).
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society report of survey received 16 FEB 06.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 February 2006
Resolved
Class to inspect OWS due to presence of two bypass hose connections for overboard discharge. Class to verify system is in full compliance with Marpol Annex I/16&17 prior to departure.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Classification Society Report of Survey received 16 Feb 06.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 14 February 2006
Resolved
Sewage system is not being maintained in accordance with manufacture's requirements. 33 CFR 159.121.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2006
Documentation › Logs/Records › Garbage Recordkeeping
Issued 14 February 2006
No resolution recorded
Garbage: Mixed garbage was found throughout the vessel. Plan is not ship specific. Crew is not following the plan for disposal of garbage or separation. [name withheld] is not recording incineration of rags in the garbage log. Marpol V/9.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 14 February 2006
Resolved
Ballast Water Plan: Add Cargo Hold #3 to plan, conduct and record crew training. Utilize Ballast Water Handling Log to record sediment. 33 CFR 151.2035.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2006
Deck/Cargo › Ballast
Issued 3 March 2004
Resolved
BALLAST DISCHARGE PIPING LOCATED STBD SIDE LOWER ENGINE ROOM HAS A TEMP REPAIR. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 29 May 2004
Resolution: Received FAX from China [name withheld] attesting to repairs.
Fire Fighting › Fire Main
Issued 3 March 2004
Resolved
FIRE MAIN WASTED FWD OF CARGO HOLD #1. LEGACY COMPONENT DESC: Material
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 29 May 2004
Resolution: as per FAX
Construction/Loadline › Structures
Issued 3 March 2004
Resolved
BULWARK STIFFENERS WASTED IWO DECK. LEGACY COMPONENT DESC: Plowshare Breakwater
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 29 May 2004
Resolution: as per FAX
Construction/Loadline › Structures
Issued 3 March 2004
Resolved
DOGS MISSING (4) ON MAIN DECK BOSN HOLD DOOR. LEGACY COMPONENT DESC: Door
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 29 May 2004
Resolution: as per FAX
Electrical
Issued 1 April 2000
Resolved
PAINT IS STORED IN STARBOARD LOCKER BETWEENNUMBER TWO AND NUMBER THREE HOLDAND LIGHT FIXTURES ARE NOT EXPLOSION PROOF.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 1 April 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Fire Fighting
Issued 15 October 1997
Resolved
FIRE HOSES, SPANNER WRENCHES, AND NOZZLES MISSING THROUGHOUT ENGINE ROOM. _x001C_HOSES AND NOZZLES DONT MATE, DIFFERENT SIZES. (SOLAS 74 (amended) CH II-2 REG 21)
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998
Navigation
Issued 5 November 1991
Resolved
VESSEL TRANSITED U.S. WATERS WITHOUT HAVING CORRECTIONS TO CHARTS 18400, 18440 AND 18453._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Navigation
Issued 1 March 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH CHARTS NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33 (A)(1)(II) OR AN EQUIVALENT FOREIGN GOVERNMENT CHARTS IAW 33 CFR 164.33(B).
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988