MAURY USCG vessel records Sign in
← All vessels

SPIRIT

SPIRIT is a 1984 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1985, most recently in August 2026, along with 81 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 11 August 2026.

Built
1984
Last inspected
11 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ3447
230211
Flag
UNITED STATES
368379010
Maury page id
psix-230211

Inspections, by type

…with no type recorded8
Years with a record 40 calendar years (1985–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.6 ft × 19.5 ft × 6.0 ft
Registered tonnagegross 70 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSOLDOTNA, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 3 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Dead Weight, Ton
70 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP7134MMSI 368379010 · active · compulsorily equipped · granted 17 July 2024, expires 17 July 2034
WDI2370MMSI 367677460 · expired · voluntarily equipped · granted 9 June 2015, cancelled 12 July 2025
WCR4581MMSI not assigned · expired · compulsorily equipped · granted 8 May 1995, cancelled 9 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THUNDERBIRD Passenger (Inspected) · MISLE 270935 · 14 June 2017 · activity 6261316

Inspection history · 70

11 August 2026 Type not recorded
No type recorded · USCGC FREDERICK MANN (WPC 1160) · USCG Arctic District (CGD-A) · Activity 8462167
15 July 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8439279
20 May 2025 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8139766
17 March 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8095343
17 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7959531
25 April 2024 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7901971
29 August 2023 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7780308
22 August 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7775032
25 July 2023 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7752186
28 March 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7658115
12 July 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7505110
29 June 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7491086
26 April 2022 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7438821
26 August 2021 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7297652
29 April 2021 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7205925
20 April 2021 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7178736
29 May 2020 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6978537
29 April 2020 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6950011
4 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6827952
19 June 2019 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6696743
10 April 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6659840
22 February 2019 Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6630712
11 June 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6441281
25 July 2017 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6220581
14 June 2017 Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6261316
13 June 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6180765
8 June 2016 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6016313
23 March 2016 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5862506
17 June 2014 Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4891600
13 March 2014 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4828629
12 June 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4343188
1 December 2011 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4215622
11 February 2010 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3678889
29 April 2009 Internal Structural Exam · Annual Inspection · Spot Check · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3463699
12 June 2008 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3242857
20 May 2007 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3014796
1 May 2006 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2647870
24 May 2005 COI Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2367183
7 April 2004 Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2040163
28 May 2003 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1804035
7 August 2002 COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1659112
5 October 2001 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1076377
27 April 2001 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1063656
7 August 2000 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 170357
16 May 2000 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1361482
4 October 1999 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1384263
15 July 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1104694
5 May 1999 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1441522
13 April 1998 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1125710
6 May 1997 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1098753
23 May 1996 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1191626
6 May 1996 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1085091
9 April 1996 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1080499
1 June 1995 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1183367
11 May 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1218881
29 March 1995 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1374243
13 April 1994 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 856937
13 April 1994 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1167389
24 February 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 856464
5 May 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1385072
27 April 1992 Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1260684
29 April 1991 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 923133
20 April 1990 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1219090
26 April 1989 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1195596
4 May 1988 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 894507
20 April 1988 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339720
15 September 1987 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1319320
29 April 1987 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1326379
9 April 1986 Credit Drydock · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999166
30 April 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 985934

Deficiency record · 81

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2025 Resolved
Ensure gen shutdown when pressure switch is activated by fixed fire fighting system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 May 2025 Resolved
Ensure there are liferafts for 50 total persons. Vsl restricted to 25 total person until full compliment of primary lifesaving is onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2025
Resolved 16 June 2025
Resolution: LR installed
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 May 2025 Resolved
Provide operating instructions for fixed fire fighting system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025 Resolved
Port fuel tank is leaking at emergency shutoff valve. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: repaired
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2025 Resolved
Ensure all PFDs are provided with proper CG approved water light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: all PFDs had lights
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2025 Resolved
Ensure laz high water alarm is operational.
Action required: 10 - Deficiency Rectified
Resolved 21 May 2025
Resolution: corrected onsite
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 May 2025 Resolved
Ensure first aid kit is up-to-date. Missing aspirin and iodine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: up-to-date
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2025 Resolved
Prove proper operation of bilge system from tank room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: bilge system test sat
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 21 May 2025 Resolved
Develop crew training per 46 CFR 185.420(b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: crew training provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2025 Resolved
Develop safe handling procedures for hazardous materials.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: safe handling procedures developed
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 21 May 2025 Resolved
Conduct satisfactory MOB and fire drills in the presence of a CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: conducted satisfactory drills
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 March 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Conducted satisfactory drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2021 Resolved
REPLACE ENGINE RAW WATER FLEX HOSES. WHERE FOUND WASTED WITH AN APPROVED TYPE FOR THE PORT & STARBOARD ENGINES.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 5 May 2021
Resolution: replaced
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 29 April 2021 Resolved
INSTALL GUARDS OR CHAIN OFF AREA FOR THE EXPOSED AREA OF BELTS ON THE PORT & STARBOARD ENGINES.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 5 May 2021
Resolution: replaced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 April 2021 Resolved
RE-INSTALL SMOKE DETECTORS IN ACCOMODATION SPACES.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 29 April 2021
Resolution: installed
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 April 2021 Resolved
PROVIDE PROOF OF ALL MASTERS HOLDING A VALID FCC RADIO OPERATORS PERMIT.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 29 April 2021
Resolution: proof provided
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 April 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 29 April 2021
Resolution: replaced
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 29 April 2021 Resolved
SHOW PROOF OF LOCKING THE SEWAGE OVERBOARD VALVE WHILE INSIDE OF 3NM.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 29 April 2021
Resolution: installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 June 2019 Resolved
Replace piping for fixed fire fighting system where it has wasted aft of port MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 11 July 2019
Resolution: New section of piping installed to replace worn section.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 June 2019 Resolved
Replace port running light red lens.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 11 July 2019
Resolution: New lens installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2019 Resolved
Replace retroreflective tape on 5 lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 11 July 2019
Resolution: New retroreflective tape installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 June 2019 Resolved
Replace expired battery on lifebuoy waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 11 July 2019
Resolution: New battery of the correct type installed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 June 2019 Resolved
Provide current Light List and Coast Pilot
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 11 July 2019
Resolution: Exceprts of current publications onboard.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 June 2018 Resolved
Vessel's smoke detector in accomodation space was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Vessel installed new smoke detectors.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 June 2018 Resolved
Vessel's first aid kit had expired medicine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Vessel replaced expired medication.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2018 Resolved
Vessel's distribution panel was not labeled with source and amperage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 June 2019
Resolution: Labeling inspected satisfactory this date.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2018 Resolved
Vessel's generator alarm panel was not bolted down.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Vessel secured generator alarm panel.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 June 2018 Resolved
Vessel's lazzarette had a spare anchor bolted down under the stairs along with a very slippery rubber matt that caused a unsafe condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Vessel installed new rubber matts.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 June 2018 Resolved
Vessel's autopilot wiring was wired incorrectly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Vessel rewired autopilot and placed in wire loom.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 26 July 2017 Resolved
Provide FCC Radio Station Authorization Certificate onboard. 47CFR80.13
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 13 June 2018
Resolution: Vessel had new FCC certificate.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 26 July 2017 Resolved
Master needs to obtain a Marine Radio Operators Permit. 47CFR80.159
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 13 June 2018
Resolution: Vessel's master had radio operator permit.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 26 July 2017 Resolved
Make repairs to ventilation covers. 46CFR182.465(h)
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 13 June 2018
Electrical › Electric Generation Source (service) › Generator
Issued 26 July 2017 Resolved
Provide automatic shutdowns for both generators in engine room. 46CFR181.410(b)(10)
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 13 June 2018
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 June 2016 Resolved
Provide updated Coast Pilot.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 10 June 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 June 2016 Resolved
Provide cover, guard or rail for exposed rotating machinery in front of both engines.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 10 June 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 June 2016 Resolved
Provide alcohol test strips.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 10 June 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 June 2016 Resolved
Provide FCC safety certificate.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 10 June 2016
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 12 June 2012 Resolved
Total persons reduced to 50 due to 1 50 person liferaft on board.
Action required: 705 - Other - as specified
Resolved 17 June 2014
Resolution: Overdue def, cleared after verification that 100% lifesaving onboard and serviced.
Documentation › Certificates/Documents › Stability Letter
Issued 29 December 2011 Resolved
Vessel's passenger count is reduced to 46 until new stability letter is issued my USCG Marine Safety Center. Vessel to submit all applicable documentation to MSC.
Action required: 705 - Other - as specified
Resolved 12 June 2012
Fire Fighting
Issued 5 May 1999 Resolved
PROVIDE FIXED FIRE EXTINGUISHING SYSTEM IN ENGINESPACE IAW CURRENT REGULATIONS.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE PROOF OF RELEASE DATE ON EPIRB.
Condition: Unknown
Due 11 May 1998
Resolved 21 May 1998
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE RECORD OF DRILLS AND TRAINING.
Condition: Unknown
Due 11 May 1998
Resolved 21 May 1998
Navigation
Issued 13 April 1998 Resolved
MARK VESSEL NAME ON EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 4 May 1998
Resolved 7 May 1998
Accommodation/Occupational Safety
Issued 13 April 1998 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 4 May 1998
Resolved 7 May 1998
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 4 May 1998
Resolved 7 May 1998
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE RECORD OF MONTHLY EPIRB TESTING.
Condition: Unknown
Due 11 May 1998
Resolved 21 May 1998
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE PROOF OF BATTERY EXPIRATION DATE ON EPIRB.
Condition: Unknown
Due 11 May 1998
Resolved 21 May 1998
Construction/Loadline
Issued 13 April 1998 Resolved
PROVE PROPER OPERATION OF ENGINE DRIVEN FIXED BILGE PUMP.
Condition: Unknown
Due 11 May 1998
Resolved 21 May 1998
Fire Fighting
Issued 13 April 1998 Resolved
WEIGH BOTTLES OF FIXED CO2 SYSTEM.
Condition: Unknown
Due 11 May 1998
Resolved 21 May 1998
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE 5 ADDITIONAL ADULT PFD'S. VESSEL LIMITED TO 55 PERSONS TOTAL UNTILTHIS ITEM CLEARED.
Condition: Unknown
Due 11 May 1998
Resolved 21 May 1998
Construction/Loadline
Issued 6 May 1997 Resolved
PROVE PROPER OPERATION OF FIXED ENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 13 May 1997
Resolved 19 May 1997
Navigation
Issued 6 May 1997 Resolved
PROVE PROPER OPERATION OF MAST LIGHT.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 6 May 1997 Resolved
VERIFY AND MARK EXPIRATION DATE ON EPIRB BATTERY.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Electrical
Issued 6 May 1996 Resolved
REPLACE BURNED OUT LIGHT IN ENGINE ROOM, STARBOARD SIDE AFT.
Condition: Unknown
Due 6 May 1996
Resolved 22 May 1996
Lifesaving
Issued 6 May 1996 Resolved
PROVIDE THREE ADDITIONAL RED FLARE DISTRESS SIGNALS.
Condition: Unknown
Due 6 May 1996
Resolved 22 May 1996
Navigation
Issued 6 May 1996 Resolved
PROVE PROPER OPERATION OF ALL REUNNING LIGHTS.
Condition: Unknown
Due 6 May 1996
Resolved 22 May 1996
Documentation
Issued 6 May 1996 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 6 May 1996
Resolved 22 May 1996
Lifesaving
Issued 6 May 1996 Resolved
MARK PFD STOWAGE LOCATION PER ACTUAL LOCATION.
Condition: Unknown
Due 6 May 1996
Resolved 22 May 1996
Engineering
Issued 6 May 1996 Resolved
TIGHTEN PACKEN ON PORT SHAFT TO CONTROL EXCESSIVE LEAKAGE.
Condition: Unknown
Due 6 May 1996
Resolved 22 May 1996
Documentation
Issued 6 May 1996 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING FOR ALL CREW.
Condition: Unknown
Due 8 May 1996
Resolved 22 May 1996
Accommodation/Occupational Safety
Issued 6 May 1996 Resolved
REMOVE GEAR FROM TOP OF ESCAPE HATCH FROM FREEZER SPACE AND MARK HATCH " DONOT BLOCK-EMERGENCY EXIT".
Condition: Unknown
Due 8 May 1996
Resolved 22 May 1996
Construction/Loadline
Issued 6 May 1996 Resolved
PROVE PROPER OPERATION OF FIXED ENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 6 May 1996
Resolved 22 May 1996
Engineering
Issued 6 May 1996 Resolved
MARK LOCATION OF REMOTE FUEL OIL SHUTOFF VALVES.
Condition: Unknown
Due 8 May 1996
Resolved 22 May 1996
Fire Fighting
Issued 6 May 1996 Resolved
HAVE CERTIFIED COMPANY SERVICE FIXED HALON SYSTEM. UNTIL SERVICING COMPLETE, MOUNT ADDITIONAL BII FIRE EXTINGUISHER BY ACCESS OR IN ENGINE ROOM.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 6 May 1996 Resolved
PROVIDE TWO 4 FOOT PADDLES FOR EACH LIFEFLOAT.
Condition: Unknown
Due 8 May 1996
Resolved 22 May 1996
Lifesaving
Issued 6 May 1996 Resolved
PROVIDE 100 FOOT PAINTER AND WEAK LINKS FOR LIFEFLOATS.
Condition: Unknown
Due 8 May 1996
Resolved 22 May 1996
Lifesaving
Issued 29 March 1995 Resolved
PROVIDE NEW BATTERY FOR EPIRB & MARK EPIRB IAW 46 CFR 180.40
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 29 March 1995 Resolved
REPLACE DETERIORATED NET SUPPORT LINE ON PORT & STARBOARD LIFEFLOATS.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 29 March 1995 Resolved
PROVIDE NEW RING LIFE BUOYS IAW 46 CFR 180.30.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 29 March 1995 Resolved
CONDUCT FIRE & MAN OVERBOARD DRILLS W/ PERMANENT VSL CREW.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 29 March 1995 Resolved
LASH PADDLES TO LIFEFLOATS IAW 46 CFR 180.15.10.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Navigation
Issued 29 March 1995 Resolved
PROVIDE CURRENT NAVIGATION PUBS & CHARTS.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Documentation
Issued 29 March 1995 Resolved
PROVIDE & POST ONBOARD VSL ORIGINAL CREW LICENSES.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 29 March 1995 Resolved
PROVIDE PLANS TO INCREASE RAIL HEIGHT TO 42" UNLESS VSL WILL BE OPERATING PRIMARILY AS A CHARTER FISHING VESSEL.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 13 April 1994 Resolved
Replace life lines on Life Float.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 13 April 1994 Resolved
Reinstall side access door
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Accommodation/Occupational Safety
Issued 13 April 1994 Resolved
Post waste management plan
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Fire Fighting
Issued 13 April 1994 Resolved
WEIGH FIXED FIRE BOTTLES
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Engineering
Issued 13 April 1994 Resolved
Replace Cutless Bearing on aft strut of port shaft.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Documentation
Issued 13 April 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Accommodation/Occupational Safety
Issued 5 May 1993 Resolved
RESTENCIL "KEEP CLEAR" WARNING ON EMERGENCY HATCH.
Condition: Unknown
Due 31 May 1993
Resolved 4 August 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.