Records from 1984 to 2005. Most recent: inspection, 22 July 2005.
Inspection history · 51
22 July 2005
COC-MODU Renew · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2433229
3 May 2004
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2058094
3 June 2003
Certificate of Compliance · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1808464
26 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735561
15 July 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646698
3 May 2002
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1611667
22 March 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495865
26 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481547
3 May 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397642
3 February 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058612
27 September 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054124
20 July 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1051488
19 June 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 818705
4 May 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1421864
8 June 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 811044
13 May 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1415177
21 December 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 810653
16 October 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 802154
23 July 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130370
11 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 110209
18 May 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446645
21 May 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1465316
23 April 1997
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1095262
1 April 1997
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1102538
27 June 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932297
13 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764952
23 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 201669
21 May 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447591
19 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188683
8 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186031
19 January 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412594
16 June 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449612
22 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120272
23 June 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439335
2 June 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1256400
28 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 15749
20 January 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 590
30 July 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1245512
11 July 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1252690
10 July 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 937137
8 July 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1253739
4 October 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931292
9 July 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229844
5 July 1990
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914481
6 July 1989
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1204517
7 July 1988
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1349966
13 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018331
10 July 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309271
11 July 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 988809
10 July 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 985874
12 June 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972751
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 July 2005
Resolved
Replace all retro-reflective material on life buoys where they have stenciling on them.
Due 22 August 2005
Resolved 23 July 2005
Lifesaving › Launching Appliances › Winch
Issued 22 July 2005
Resolved
Prove weekly and monthly winch inspections as per 46 CFR 109.301(e).
Due 22 August 2005
Resolved 24 July 2005
Lifesaving › Launching Appliances › Davit
Issued 22 July 2005
Resolved
Prove proper operation of #2 Lifeboat limit switch. Also provide 6-12 inches of air gap between lifeboat and davit when winch cuts out.
Due 22 August 2005
Resolved 22 July 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 22 July 2005
Resolved
Prove proper operation of emergency ventilation shutdown in engineroom.
Due 22 August 2005
Resolved 22 July 2005
Lifesaving › Inflatable Liferafts › Container Marking
Issued 22 July 2005
Resolved
Renew liferaft operating instructions on #2 liferaft.
Due 22 August 2005
Resolved 25 July 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 July 2005
Resolved
Prove proper IMO symbology is being used identifying liferings.
Due 22 August 2005
Resolved 22 July 2005
Navigation › Piloting/Steering › Swing Meter
Issued 22 July 2005
Resolved
Replace wind indicator.
Due 22 August 2005
Resolved 22 July 2005
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 22 July 2005
Resolved
Prove proper purge alarm on oilfield gas detector and drillers console.
Due 22 August 2005
Resolved 23 July 2005
Personnel › Certificates/Documents/Licenses
Issued 3 June 2003
Resolved
PROVIDE PROOF OF APPLICATION FOR PANAMANIAN LICENSES.
Due 3 July 2003
Resolved 2 July 2003
Resolution: Received fax confirmation for application submittal to Panama.
Electrical › Electrical Distribution System (service)
Issued 3 May 2002
Resolved
At main deck forward of house crop and renew wasted and holed wire conduit. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 13 May 2002
Construction/Loadline › Structures
Issued 3 May 2002
Resolved
At main deck junction of house crop and renew wasted and holed portion of house bulkhead. Insert to good steel minimum 18 by 18 inches. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 13 May 2002
Unknown
Issued 3 May 2001
Resolved
OBTAIN AND INSTALL CORRECT SAFETY RELIEF VALVES (2ea.) FOR DOMESTIC HOT WATER HEATER.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Electrical
Issued 3 May 2001
Resolved
PROPERLY SECURE / SUPPORT WIRING, INCLUDING 3rd PARTY WIRING, WITH METAL BANDING, THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Unknown
Issued 4 May 2000
Resolved
Conduct internal inspection of pressure vessels and test relief valves.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Accommodation/Occupational Safety
Issued 4 May 2000
Resolved
REPLACE FIRE SCREEN DOOR AT STBD PANTRY.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Accommodation/Occupational Safety
Issued 4 May 2000
Resolved
REPLACE DOOR FRAME AT ROOM 106.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Construction/Loadline
Issued 4 May 2000
Resolved
RENEW BOLTS MANWAY COVER AFT PORT MAIN DECK.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 4 May 2000
Resolved
WELD FRACTURE IN WTD MAIN DECK FWD OF HOUSE.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 4 May 2000
Resolved
RENEW PACKING GLANDS ON ALL DUMP VALVE REACH RODS.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Electrical
Issued 4 May 2000
Resolved
CONDUCT TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Electrical
Issued 13 May 1999
Resolved
JUNCTION BOX IN EMERG. GENERATOR ROOM NEEDS COVER. CORRECTED PRIOR TO COMPLETION OF INSPECTION.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Accommodation/Occupational Safety
Issued 13 May 1999
Resolved
RELIEF VALVES ON HOT WATER HEATERS FOUND TO BE INPROPER. RELIEFS SET AT 190 AND THE MAX PSI ON THE TANK IS 150. RELIEFS REPLACED WITH ORIGINALS FROM FACTORY.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 13 May 1999
Resolved
REPAIR PAINT LOCKER WTD KNIFE EDGE.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Lifesaving
Issued 13 May 1999
Resolved
INSTALL WINDSOCK ON RIG.
Condition: Unknown
Due 13 May 1999
Resolved 14 May 1999
Accommodation/Occupational Safety
Issued 13 May 1999
Resolved
REPAIR/ADJUST 02 LEVEL SELF-CLOSING DOOR IN STBD PASSAGEWAY
Condition: Unknown
Due 13 May 1999
Resolved 14 May 1999
Electrical
Issued 13 May 1999
Resolved
REPLACE/INSTALL ELECTRICAL PANEL IN STBD CRANE.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Lifesaving
Issued 13 May 1999
Resolved
INSTALL PAINT LOCKER CLOSEABLE VENT.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Electrical
Issued 13 May 1999
Resolved
INSTALL E-LIGHT IN O2 CORRIDOR.
Condition: Unknown
Due 13 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 13 May 1999
Resolved
TWO HOLES FOUND IN THE BULKHEAD OF THE MUD PIT ROOM. WELDER WAS CALLED ANDREPAIRS WERE MADE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 13 May 1999
Resolved
FLEX COUPLING FOUND TO BE DAMAGED. REPLACED PRIOR TO TEH COMPLETION OF INSPECTION.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 21 May 1997
Resolved
REPAINT STARBOARD SIDE LOADLINE MARKS.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Deck/Cargo
Issued 21 May 1997
Resolved
REPAIR/REPLACE PINION GEAR COVER ON BOW LEG FORWARD JACKING GEAR, STARBOARDSIDE COVER.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Unknown
Issued 21 May 1997
Resolved
REPAIR WASTED VENT PIPE ON #3 PORT PRELOAD TANK.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Lifesaving
Issued 21 May 1997
Resolved
REATTACH DECK GRATING ON MAIN DECK STARBOARD SIDE AFT OF BOW LEG.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Lifesaving
Issued 21 May 1997
Resolved
REPAIR/REPLACE HELO SAFETY NETTING AS REQUIRED.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Unknown
Issued 21 May 1997
Resolved
REPAIR WASTED VENT PIPE DIRECTLY INBOARD OF #1 LIFEBOAT.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Lifesaving
Issued 21 May 1997
Resolved
INSTALL NEW RAILS ON #2 LIFEBOAT WINCH MOTOR PLATFORM.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Lifesaving
Issued 21 May 1997
Resolved
CROP OUT AND RENEW FORWARD CORD SUPPORT ON #2 LIFEBOAT DAVIT STRUCTURE, UPON COMPLETION WEIGHT TEST OF DAVIT TO BE WITNESSED BY COGNIZANT OCMI.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Lifesaving
Issued 21 May 1997
Resolved
REPLACE MOUNTING BOLTS ON BOTH LIFEBOAT WINCH MOTORS.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Lifesaving
Issued 21 May 1997
Resolved
REPLACE BOTTOM RAIL ON #2 LIFEBOAT DECK DIRECTLY BELOW HELO DECK.
Condition: Unknown
Due 30 May 1997
Resolved 9 June 1997
Engineering
Issued 21 May 1996
Resolved
LOCATE AND PROPERLY LABEL FUEL SHUT-OFF VALVE FOR EMERGENCY GENERATOR IN ACCESIBLE LOCATION.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
REMOVE OR PROPERLY SECURE SPERRY SUN CABLE ON RAIL, PORT AFT SIDE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
REMOVE OR SECURE EXCESS CABLE IN STBD. STAIRWAY TO PUMP ROOM.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
INSTALL EMERGENCY LIGHTING FOR LIFEBOAT EMBARKATION STATIONS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
RENEW WASTED FIREMAIN PIPING AT HELIPORT FIRE STATION.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PROVIDE RADAR TRANSPONDERS FOR EACH LIFEBOAT.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
REPLACE MISSING OR WASTED RUNGS ON ESCAPE LADDERS IN LEGS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
INSTALL LATCHES IN CLASS-A STAIRTOWER DOORS AND REMOVE LOUVERS AND UNREINFORCED GLASS FROM SAME.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Documentation
Issued 21 May 1996
Resolved
PROVIDE MANNING CERTIFICATE FROM FLAG STATE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PERFORM TRAINING (FIRE GUN) WITH LINE-THROWING GUN AND LOG.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PFD'S: PROVIDE WATERLIGHTS, WHISTLES, AND/OR RETROFLECTIVE TAPE ON PFD'S THROUGHOUT RIG AS NECESSARY. ATTACH WATERLIGHTS TO SHOULDER AREA AS NECESSARY.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PROVE PROPER OPERATION OF PURGE LOSS ALARMS TO STROKE COUNTER BOX AND DRILLER KILLER IV BOX.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
LIFEBOAT #2: INSTALL WATERLIGHTS ON PFD'S, PROVIDE ONE MORE SIGNAL MIRROR, INSTALL LIFELINE CLOSER TO STERN TO ACCOMODATE PERSONNEL ENTERING THROUGH AFT DOORS, PROVIDE ONE MORE HAND-HELD FLARE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
PERFORM TEST OF EMER. GEN. (2 HR. MONTHLY) AND EMER. BATTERIES (2 HR. LOAD)IAW 46 CFR 109 AND LOG.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
REMOVE ON/OFF SWITCHING CAPABILITIES FROM E-LIGHTS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
CALIBRATE PORTABLE GAS INDICATORS
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Documentation
Issued 21 May 1996
Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW 33 CFR 150.750.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 21 May 1996
Resolved
INSTALL BUNK LIGHTS FOR ALL BUNKS AS NECESSARY.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
SUBMIT FIRE CONTROL PLAN TO FLAG STATE FOR APPROVAL.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PROVIDE ONE BURN BLANKET WITH MEDICAL SUPPLIES.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
ENSURE PIT ROOM DOORS ARE SELF CLOSING, GAS TIGHT, THAT VENTILATION FLOWS INTO THE PIT ROOM, AND THAT AN ALARM SOUNDS WHEN VENTILATION TO PIT ROOM ISLOST.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
MOUNT JUNCTION BOX ON STBD SIDE OF DRILL FLOOR.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
INSTALL GENERAL ALARM BELL OR LIGHT IN SHAKER HOUSE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 16 June 1993
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE FOLLOWING ENGINE SAFETIES:_x001C_ OVERSPEED TRIPS ON #4 AND #5. OIL PRESSURE TRIPS ON #1 AND #4._x001C_ COMPLETE PRIOR TO ISSUANCE OF PERMANENT LOC.
Condition: Unknown
Due 16 July 1993
Resolved 21 June 1993
Electrical
Issued 16 June 1993
Resolved
REPAIR REVERSE POWER RELAY TRIP ON GENERATOR SET #2. COMPLETE PRIOR TO ISSUANCE OF PERMANENT LOC.
Condition: Unknown
Due 16 July 1993
Resolved 21 June 1993
Construction/Loadline
Issued 16 June 1993
Resolved
REPAIR AND PROVE PROPER OPERATION OF BOTH BILGE PUMPS. COMPLETE PRIOR TO FLOATING RIG.
Condition: Unknown
Due 16 July 1993
Resolved 25 June 1993
Electrical
Issued 16 June 1993
Resolved
SUBMIT PROPOSAL REGARDING CUT CABLES FOR DRILLING PACKAGE TO MSO MORGAN CITY. COMPLETE PRIOR TO ISSUANCE OF PERMANENT LOC.
Condition: Unknown
Due 16 July 1993
Resolved 25 June 1993
Lifesaving
Issued 16 June 1993
Resolved
REPAIR GENERAL ALARM HORNS ON MAIN DECK AND LIGHT IN MOTOR ROOM. COMPLETE PRIOR TO ISSUANCE OF PERMANENT LOC.
Condition: Unknown
Due 16 July 1993
Resolved 21 June 1993
Construction/Loadline
Issued 16 June 1993
Resolved
ADJUST WATERTIGHT DOORS. COMPLETE PRIOR TO ISSUANCE OF PERMANENT LOC.
Condition: Unknown
Due 16 July 1993
Resolved 21 June 1993
Construction/Loadline
Issued 8 July 1991
Resolved
CROP TO GOOD METAL AND RENEW WASTED STRUCTURE ON BULKHEAD BETWEEN MUD PIT AND MUD PUMP ROOM IN THE VICINITY OF THE CAT WALK.
Condition: Unknown
Due 8 July 1991
Resolved 8 July 1991
Documentation
Issued 8 July 1991
Resolved
PROVIDE UPDATED OPERATING MANUAL OR EVIDENCE THAT UPDATED MANUAL HAS BEEN SUBMITTED FOR APPROVAL.
Condition: Unknown
Due 8 July 1991
Resolved 8 July 1991
Deck/Cargo
Issued 8 July 1991
Resolved
PROVIDE DATA FOR HYDROTEST FOR OIL TRANSFER HOSE
Condition: Unknown
Due 8 July 1991
Resolved 8 July 1991
Unknown
Issued 4 October 1990
Resolved
POUR SEALED FITTINGS ON "SUN" MUD CIRCULATING PUMP JUNCTION BOX. REMOVE DEAD END WIRING OR RUN TO PROPER JUNCTION BOX, PROVIDE PROPER GLAND PENETRATION SEAL TO POWER SIDE JUNCTION BOX.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROPERLY SUPPORT OVERHEAD RUNS OF WIRING IN MUD PITS.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
POUR EYES FITTINGS ON GAITRONICS PHONE BOX AND SPEAKER UNIT IN MUD PITS, AND ON EXPLOSION PROOF SWITCH BOX LOCATED BY FIRE EXPINGUISHER #40.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
DETERMINE CAUSE OF EXCESSIVE GROUND (AND REPAIR) TO MAIN SWICTH BOARD IN GENERATOR ROOM.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROVIDE POWER INTERRUPTION FEATURE TO LOGGING TRAILER IN ACCORANCE WITH NFPA 496. DELAY FOR NOT MORE THAN 30 SECONDS IS ACCEPTABLE.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROPERLY MOUNT WIRING TO PORT/STBD RUNNING LIGHTS.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROVIDE PROPER BULBS TO PORT / STBD RUNNING LIGHTS.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
CONDUCT AN ANNUAL SAFETY EXAM, PROPERLY ENDORSE PANAMANIAN MODU SAFETY CERTIFICATE BY A RESPONSIBLE AGENT OF THE PANAMANIAN GOVERNMENT.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
REPAIR PURGE PRESSURE INDICATOR IN MUD LOGGING TRAILER.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROVIDE SEALED FITTINGS (CLASS I DIVISION I) FOR PENETRATIONS TO EXPLOSION PROOF SWITCH BOXES FOR BOTH LOWER SHAKERS.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
POUR EYES FITTINGS ON GAITRONICS PHONE BOX AND SPEAKER IN SHALE SHAKER.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOX STBD FORWARD SHAKER.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROVIDE EXPLOSION PROOF INSTALLATION TO SWECO MUD CLENING UNIT IN SHAKER AREA (CLASS I DIVISION I AREA); MUST INCLUDE PROPER SEALED FITTINGS, WIRING; PLUG FEATURE MUST BE EXPLOSION PROOF.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOXES LOCATED ABLOVE AND BETWEEN TWO LOWER SHAKERS.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROVIDE SEALED FITTINGS (CLASS I DIVISION I) FOR BOTH EXPLOSION PROOF SWITCH BOXES ON MUD FLOW LINE BENEATH RIG FLOOR.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROERLY MOUNT HANGING / UNSUPPORTED WIRING LOCATED STBD SIDE BENEATH RIG FLOOR BY MUD FLOW LINE.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROPERLY MOUNT LOOSE WIRING PORT SIDE BENEATH SHAKER AREA; REMOVE WIRING FROM DECK AND PROPERLY MOUNT.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROVIDE SEALED FITTINGS AND PROPER WIRING (ARMORED OR MI IN CLASS I DIVISION I AREA, "SO" NOT PERMITTED) TO "SWECO" MUD CLEANER PUMP BENEATH SHAKER AREA.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 4 October 1990
Resolved
PROVIDE EXPLOSION PROOF INSTALLATION FOR JUNCTION BOX TO " ATLAS WIRE LINE"UNIT. BOX IS LOCATED IN CLASS I DIVISION I AREA, FORWARD CATWALK OF SHAKER AREA.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Unknown
Issued 9 July 1990
Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOXES LOCATED ABOVE AND BETWEEN TWO LOWER SHAKERS.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
DETERMINE COURSE OF EXCESSIVE GROUD (AND REPAIR) TO MAIN SWITCH BOARD IN GENERATOR ROOM.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROPERLY MOUNT WIRING TO PORT ? STBD RUNNING LIGHTS
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROVIDE PROPER BULBS TO PORT ? STBD RUNNING LIGHTS.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
CONDUCT AN ANNUAL SAFETY EXAM. PROPERLY ENDORSE PAN. MODU SAFETY CERT. BY A RESPOSIBLE AGENT OF PAN GOVERNMENT.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROVIDE SEALED FITTINGS (CLASS I DIV I) FOR BOTH EXPLOSION PROOF SWITCH BOXES ONB MUD FLOW LINE BENEATH RIG FLOOR.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROPERLY MOUNT HANGING/UNSUPPORTED WIRING LOCATED STBD SIDE BENEATH RIG FLOOR BY MUD FLOW LINE.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROPERLY MOUNT LOOSE WIRING PORT SIDE BENEATH SHAKER AREA; REMOVE WIRING FROM DECK AND PROPERLY MOUNT.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROVIDE EXPLOSION PROOF INSTALLATION FOR JUNCTION BOX TO "ATLAS WIRELINE" UNIT. BOX IS LOVCATED IN CLASS I DIV I AREA, FORWARD CATWALK OF SHAKER AREA.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROVIDE SEALED FITTINGS AND PROPER WIRING (ARMORED OR MI IN CLASS I DIV I AREA, "SO" NOT PERMITTED) TO "SWECO" MUD CLEANER PUMP BENEATH SHAKER AREA.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
POUR SEALED FITTINGS ON SUN MUD CIRCULATING PUMP JUNCTION BOX REMOVE DEAD END WIRING OR RUN TO PROPER JUNCTION BOX, PROVIDE PROPER GLAND PENETRATION SEAL TO POWER SIDE JUNCTION BOX.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROPERLY SUPPORT OVERHEAD RUNS OF WIRING IN MUD PITS.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
POUR EYS FITTINGS ON GAITRONICS PHONE BOX AND SPEAKER UNIT IN MUD PITS, ANDON EXPLOSION PROOF SWITCH BOX LOCATED BY FIRE EXTINGUISHER #40.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
REPLACE MISSING MECHANISM TO SELF CLOSING FIRE DOOR 2ND LEVEL STAIR TOWER, QUARTERS AREA.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROVIDE POWER INTERRUPTION FEATURE TO LOGGING TRAILER IN ACCORDANCE WITH NFPA-496. DELAY FOR NOT MORE THAN 30 SECONDS IS ACCEPTABLE.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
REPAIR PURGE PRESSURE INDICATOR IN MUD LOGGING TRIALER.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROVIDE SEALED FITTINGS (CLASS I DIV I) FOR PENETRATIONS TO EXPLOSION PROOFSWITCH BOXES FOR BOTH LOWER SHAKERS.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
POUR EYS FITTINGS ON GAITRONICS PHONE BOX AND SPEAKER IN SHALE SHAKER.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOX STBD FORWARD SHAKER.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 9 July 1990
Resolved
PROVIDE EXPLOSION PROOF INSTALLATION TO SWECO MUD CLEANING UNIT; MUST IN- CLUDE PROPER SEALED FITTINGS, WIRING; PLUG FEATURE MUST BE EXPLOSION PROOF
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Unknown
Issued 5 July 1990
Resolved
SQUARE AWAY WIRING TO TWO "TOTCO" PANELS LOCATED BY ENTRANCE TO LOGGING TRIALER, REPLCE NON-APPROVED WIRING (MUST BE ARMORED OR MI) PLASTIC TIE WRAPS NOT PERMITTED; NO TAPED SPLICED JUNCTIONS PERMITTED.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
POUR EYS ON JUNCTION BOX LOCATED FORWARD OF LOGGING TRAILER ON HANDRAIL ABOVE SHALE SHAKER.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
REPLACE "SO" CABLE TO LOGGING TRAILER ON SHALE SHAKER (MUST BE MI OR ARMORED.)
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE LOSS OF PURGE INDICATORS OR ALARMS FOR DRAW WORKS MOTORS, DRILLER'SCONSOLE IN ACCORDANCE WITH NFPA-496.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROPERLY MARK MASTER LOSS OF PURGE ALARM ON RIG FLOOR.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE LOSS OF PURGE ALARM TO "ADAIR" GAS DETECTOR PANEL STBD / AFT RIG FLOOR I ACCORDANCE WITH NFPA-496.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE EXPLOSION PROOF SWITCH BOX FOR SWACO UNIT LOCATED STBD AFT RIG FLOOR .
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE LOSS OF PURGE ALARM FOR TOTCO MONITOR IN ACCORDANCE WITH NFPA-496.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE LABELS FOR ALL PURGED ENCLOSURES IN ACCORDANCE WITH NFPA-496.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE PURGE AND LOSS OF PURGE ALARM FOR MUD PIT VOLUME FLOW INDICATOR PANEL IN ACCORDANCE WITH NFPA-496, LOCATED ON RIG FLOOR.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
POUR EYS FITTINGS ON GAITRONICS PHONE ON RIG FLOOR (AND SPEAKER HORN DRIVER).
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE EXPLOSION PROOF GENERAL ALARM CONTACT MAKER ON RIG FLOOR WITH PROPER SEALED FITTINGS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE SEALED FITTINGS FOR KILL SWITCHES FOR DRAWWORKS BLOWERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROPERLY LABEL GENERAL ALARM HORN ON RIG FLOOR.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROPERLY SUPPORT ALL OVERHEAD WIRING RUNS ON RIG FLOOR; PLASTIC TIE WRAPS NOT PERMITTED, HANGERS SHALL BE MIN. 5/8' NON CORROSIVE WITH IEEE-45(IN- CLUDES SERVICE COMPANY WIRING).
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
POUR EYS FITTING ON MASTER LOSS OF PURGE HORN ON RIG FLOOR.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
ENSURE ALL EYS FITTINGS ON EXPLOSION PROOF SWITCH BOXES IN SHALE SHAKER AREA AND RIG FLOOR ARE POURED WITRH CORRECT SEALANT (NOTE: MANY ARE POUREDWITH A SILICON LIKE MATERIAL.)
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE GUARD FOR GLOBE ON EXPLOSION PROOF LIGHT IN DOG HOUSE.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE COVER TO EXPLOSION PROOF LIGHT PORT AFT LEG ON RIG FLOOR.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
POUR EYS FITTINGS ON EXPLOSION PROOF SWITCH BOX TO "SUN CORP" TEMPORARY SHALE SHAKER.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROPERLY SUPPORT VERTICAL RUN OF WIRING LOCATED BY PORT AFT LEG ON RIG FLOOR.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
PROVIDE DOCUMENTATION AN OPERATING MANUAL MEETING 46 CFR 109.121 HAS BEEN SUBMITTED FOR REVIEW.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Unknown
Issued 5 July 1990
Resolved
POUR EYS FITTING ON LIGHT IN PAINT LOCKER WITH CORRECT SEALANT (CURRENTLY POURED WITH SILICON.)
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Construction/Loadline
Issued 10 July 1987
Resolved
PROVIDE EVIDENCE OF A DRYDOCK EXAMINATION (OR A SPECIAL EXAM IN LIEU OF DRYDOCK) CONDUCTED WITHIN THE LAST 24 MONTHS, OR CONDUCT DRYDOCK INSPECTIONTO BE COMPLETED PRIOR TO 9/30/87.
Condition: Unknown
Due 10 July 1987
Resolved 10 July 1987
Construction/Loadline
Issued 12 June 1984
Resolved
FREE AND MAKE OPERABLE CHECK VALVES IN PRELOAD TANKS AT DUMP VALVES.
Condition: Unknown
Due 12 June 1984
Resolved 12 June 1984
Unknown
Issued 12 June 1984
Resolved
PROVIDE COVER FOR MSD
Condition: Unknown
Due 12 June 1984
Resolved 12 June 1984