MAURY USCG vessel records Sign in
← All vessels

SPIRIT OF DANA POINT

SPIRIT OF DANA POINT is a 1984 school ship. The Coast Guard has recorded 107 inspections since 1986, most recently in April 2026, along with 186 deficiencies, 4 operational controls and 4 casualty investigations between 2011 and 2021.

Records from 1986 to 2026. Most recent: inspection, 8 April 2026.

Built
1984
Last inspected
8 April 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN4741
234104
Flag
UNITED STATES
366823550
Maury page id
psix-234104

Inspections, by type

…with no type recorded11
Years with a record 39 calendar years (1986–2026)
The 107 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)72.9 ft × 23.8 ft × 10.0 ft
Registered tonnagegross 80 / net 72
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPILGRIM OF NEWPORT INC · COSTA MESA, CA, UNITED STATES · built 1984
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDANA POINT, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
72 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN4741MMSI 366823550 · active · compulsorily equipped · granted 2 November 2022, expires 2 November 2032
WDA5763MMSI 366823550 · expired · voluntarily equipped · granted 2 July 2011, cancelled 23 October 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

UNKNOWN VESSEL Public Vessel, Unclassified · MISLE 1696913 · 10 April 2021 · activity 7212623CALIFORNIAN Passenger (Inspected) · MISLE 233158 · 7 August 1999 · activity 114018

Inspection history · 107

8 April 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8305756
5 March 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8072452
29 October 2024 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8004507
10 June 2024 Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7911571
19 March 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7835929
10 March 2024 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7876589
26 July 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7744880
29 March 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655215
9 January 2023 COI Inspection · Administrative Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610202
20 December 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7611397
17 November 2022 Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7595261
10 November 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7565192
13 October 2022 Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7570944
7 September 2022 Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7549096
13 June 2022 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7471793
16 September 2021 Examination of Repairs · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7313950
11 April 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7172686
10 April 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7212623
25 February 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7146457
16 December 2020 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7113466
6 August 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7025185
30 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6899555
4 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6816767
8 July 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6699456
20 December 2018 Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6548585
30 October 2018 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6581610
18 July 2018 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6554885
19 June 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6408156
29 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314770
28 August 2017 Administrative Inspection · Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254140
5 May 2017 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6101090
13 December 2016 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6057422
16 October 2016 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6024330
16 October 2016 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6043894
1 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5855114
4 September 2015 Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5235038
3 September 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5727130
20 June 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4838184
5 June 2014 Attraction Vessel Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4880502
25 June 2012 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4357878
17 May 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4278301
7 February 2011 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3941111
6 February 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3941862
31 January 2011 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3979729
18 January 2011 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3896591
11 February 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3415846
9 December 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3331205
20 August 2008 Attraction Vessel Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3306045
9 August 2008 Attraction Vessel Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3295397
12 June 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3166351
13 July 2007 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2997119
26 June 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2982134
30 May 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2946559
9 March 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2802654
30 October 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2810814
5 October 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2794613
20 June 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2635153
20 September 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2491777
15 August 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2464277
28 June 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2407608
14 June 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2099564
9 September 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1896102
12 June 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1810296
16 April 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1604998
26 September 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423686
13 August 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1414001
11 June 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1436602
6 April 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379073
19 August 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378773
18 August 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426259
7 August 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 114018
19 June 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193589
20 April 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 790221
19 April 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369196
5 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1447917
1 May 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1424581
14 November 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 786177
29 October 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1436001
9 July 1997 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1457477
2 May 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428755
2 May 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355776
7 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 664272
26 July 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371126
12 June 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1185902
1 May 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 213375
1 May 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380197
31 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 227438
29 April 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168789
30 April 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1146671
22 April 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841436
12 March 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356241
14 January 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1136389
25 September 1992 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1255717
24 April 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 959005
5 February 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 950563
17 May 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 910826
29 April 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213975
24 April 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241752
24 January 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 900877
15 May 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 928778
26 April 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 917337
26 May 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1205968
27 April 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1196910
12 May 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1352957
29 October 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1020172
28 May 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335566
12 June 1986 Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1029395

Deficiency record · 186

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2026 Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. Marine Inspector observed three wasted life buoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 28 May 2026
Resolution: Received pic-cleared def
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 April 2026 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 PSI at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Marine Inspector observed the pressure gauge did not read any pressure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 15 April 2026
Resolution: Received pic-cleared def
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2025 Resolved
If 1 1/2 inch diameter fire hose is used after January 1, 1990, each length of hose must be lined commercial fire hose that conforms to Underwriters' Laboratories, Inc., standard 19. Fire hose was not in compliance with Underwriters' Laboratories, Inc., standard 19.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 21 March 2025
Resolution: New UL hose installed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 5 March 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Radiotelephony Certificate was expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 21 March 2025
Resolution: FCC certificates provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 March 2025 Resolved
The portion of the collision bulkhead that is below the bulkhead deck must be watertight. MI observed two bulkhead penetrations that are not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 11 April 2025
Resolution: Penetrations properly plugged and sealed.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 10 June 2024 Resolved
The materials used and the minimum thickness allowed in the construction of independent fuel tanks shall be as indicated in Table 182.20-25(a)(1); fuel tanks constructed of Aluminum shall have a minimum thickness of 0.250 inches (USSG). Both port and starboard fuel tanks have severe corrosion, causing a fuel leak into the bilge. Inspect tanks and identify source of leak and provide written proposal for repair and or replacement. 46 CFR 182.20-25(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2024
Resolution: MI attended vsl to witness hydro(5psi) on STBD and pneumatic (2psi) on Port
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 June 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard. Diesel fuel was observed in the bilge in the vicinity of the port/STBD fuel tanks. Remove fuel and oil from the bilges. 46 CFR 176.830 (b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2024
Resolution: Fuel removed from bilge
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 10 June 2024 Resolved
Any solid fixed ballast used to comply with the requirements of parts 170, 171, 178, and 179 of this chapter must be stowed in a manner that prevents shifting of the ballast. Ballast bars found shifted in several areas. Ballast must be arranged as per approved stability letter and secured to prevent shifting. 46 CFR 178.510 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2024
Resolved 15 August 2024
Resolution: Ballast secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following unmanned spaces: A space with a through-hull fitting below the deepest load waterline, such as the lazarette. High level bilge alarm in aft cabin bilge was placed in a container and subject to shifting or movement. Secure bilge pump or container to prevent future movement. 46 CFR 182.530(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 2 July 2024
Resolution: Bilge alarm secured to frame
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 June 2024 Resolved
An internal structure examination conducted in compliance with 46 CFR 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members , including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Wood defect found on framing found in reefer compartment bilge on STBD side in way of deck plate, 2nd frame aft of bulkhead. Provide a proposal for frame repair or replacement during next dry dock. 46 CFR 176.610 (b) Action code: 705 c: Rectify prior to credit Drydock.
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 21 November 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 March 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. MI Observed the following conditions: -The port side hook attaching steering line to rudder tiller found to be excessively corroded. Attachment hook requires replacement. 46CFR182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 2 April 2024
Resolution: Steering line attachment block replaced with renewed block.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 March 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. MI Observed the following conditions: -Possible crack found on rudder post tiller. Conduct non-destructive testing, such as dye penetrate, in the presence of attending CG Marine Inspector. 46CFR182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 3 April 2024
Resolution: Dye Pennetrant test witness by attending marine inspector, no crack detected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. MI Observed the following conditions: -Propeller shaft in way of main mast found to be chaffing steel mast collar. Make repairs to ensure appropriate clearance between collar and prop shaft. 46CFR182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 3 April 2024
Resolution: Collar raise and secured in place, no longer touching propeller shaft.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 March 2024 Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. Main sail mast hoop found to be broken. Broken hoop requires replacement. 46CFR177.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 3 April 2024
Resolution: Broken hoop was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 March 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material. Retro-reflective materials of a sufficient width (approximately 5 cm) should be applied around or on both sides of the body of the lifebuoy at four evenly-spaced points. Properly apply required retroreflective tape. 46CFR185.604(i) - IMO Res A.658(16)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 3 April 2024
Resolution: Retro tape installed on all ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 March 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Properly mark the hydrostatic release on the inflatable buoyant apparatus. 46CFR185.740(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 3 April 2024
Resolution: Hydro properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 March 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The bilge piping valves require appropriate labeling to ensure effective operation. 46CFR176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 3 April 2024
Resolution: All bilge valves properly marked.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 March 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in both port and starboard aft cabins. Remove or properly terminate exposed wires. 46CFR183.200 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 8 April 2024
Resolution: Received photos of dead end wires properly terminated in junction box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Provide a sail rigging preventative maintenance plan which contains all required contents as listed in section II of enclosure (1) to NVIC 02-16 as well as appendix (2) to Enclosure (1) of USCG NVIC 02-16. 46CFR176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 25 April 2024
Resolution: Received satisfactory sail rigging pmp.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 March 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel experienced a soft bump and go grounding while underway. A damage assessment shall be provided to OCMI for review and approval prior to carriage of passengers. 46CFR176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2024
Resolution: Vessel hired a SCUBA diver to carry out inspetion. Not damage noted.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 26 July 2023 Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand no later than the month and year on its servicing sticker affixed under 46 CFR 160.151–57(n). Vessel IBA is one month past due for annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 25 August 2023
Resolution: Operator provide documents for completing required servicing.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 9 January 2023 Resolved
The alcohol testing devices need not be carried on board each vessel if obtaining the devices and conducting the required alcohol tests can be accomplished within 2 hours from the time of occurrence of the SMI. Provide alcohol testing devices onboard. Limited to voyages <2 hours from testing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 18 January 2023
Resolution: Test strips onboard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2023 Resolved
Electrical equipment exposed to the weather must be watertight. Complete installation of new deck lighting to the satisfaction of attending MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 29 March 2023
Resolution: Completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 January 2023 Resolved
A propulsion engine control system, including pilothouse control, must be designed so that a loss of power to the control system does not result in an increase in shaft speed or propeller pitch. Provide testing procedures from manufacturer to test loss of power to engine control system and complete testing in presence of attending MI. 46 CFR 184.920
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 30 June 2023
Resolution: Provided loss of power testing and tested.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 June 2022 Resolved
Port forward chain plate rigging horizontal wood support wood wastage. Provide repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 January 2023
Resolution: Repairs verified.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 June 2022 Resolved
Aft port chain plate hardware 2 of the 3 through bolt hardware need replacement & Horizontal wood support wood rot. Provide repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 January 2023
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 June 2022 Resolved
Aft main deck stern steering assembly portside 4x4 wood support loose; re secure hardware.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 January 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2021 Resolved
The construction and arrangement of a vessel must allow for the safe operation of the vessel in accordance with its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Deterioration on the worm shoe was identified during a dive inspection. Approximately 1" of worm shoe is present. Temporarily repaired using splash zone. Vessel to effect permanent repairs at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 January 2023
Resolution: Fixed during DD.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 October 2020 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The inspector found an operable fire main system with inoperable gauges. Provide gauges for the fire main system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2020
Resolved 25 February 2021
Resolution: During the follow-up it was discovered that the fire pump has been renewed with a new pump and motor, operational testing of the pump was performed and found satisfactory.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 October 2020 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The inspector found the EPIRB battery expired. Provide new EPIRB battery.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2020
Resolved 25 February 2021
Resolution: During the follow-up it was discovered that the EPIRB was replaced with new and NOAA registration is current.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020 Resolved
Electrical equipment used in the following locations must be drip proof:(1) A machinery space;(2) A location normally exposed to splashing, water washdown, or other wet conditions within a galley, a laundry, or a public washroom or toilet room that has a bath or shower; or another space with a similar moisture level. The inspector found two outlets in the main solon had signs of heat damage. The main solon interior appears to be a wet environment due to seepage through the deck planks and open deck gratings at the access. Provide GFCI outlets throughout the main solan.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2020
Resolved 25 February 2021
Resolution: During the follow-up it was discovered that all electrical outlet in the main salon were replaced with GFCI outlets and installed in weather proof boxes.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2020 Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The inspector found the standing rigging appeared loose. Prove proper tuning of the vessels standing rigging.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2020
Resolved 25 February 2021
Resolution: During the follow-up it was discovered that the standing rigging had undergone tuning and appeared to in a firmer condition. The rig tune was verified and inspected after the annual inspection CG835 was issued in DEC20 during dry dock.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 August 2020 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel failed to complete annual inspection withing the alloted window of 3 months.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2020
Resolved 25 February 2021
Resolution: All requirements for clearing the op-control currently on the vessel have been completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2019 Resolved
Overnight passengers limited to twenty seven (27) due to egress limitations form double bunks.
Action required: 705 - Other - as specified
Due 4 October 2019
Resolved 27 January 2020
Resolution: Amended COI to reflect reduction.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 October 2019 Resolved
Provide plan for emergency lighting to illuminate emergency escape from passenger accomodations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 31 October 2019
Resolution: Vessel installed additional emergency light.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 October 2019 Resolved
Move fire axe to accessible location in way of operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 23 October 2019
Resolution: Vessel moved fire axe to main deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 October 2019 Resolved
Provide wire hangers at 24" intervals in passenger accomodations and above engine room battery boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 23 October 2019
Resolution: Vessel installed additional wire hangers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 October 2019 Resolved
Power strip found permanently installed adjacent to black powder magazines.
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Vessel disconnected and is removing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 October 2019 Resolved
A galley ventilation hood over a cooking appliance was found installed without approval. The ventilation hood does not meet the requirements of new subchapter “T”. Submit for approval an installation plan that meets the requirements of 46 CFR 181.425 to the cognizant OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 28 February 2020
Resolution: The griddle hase been decomitioned and the metal cook top has been replaced with a stone counter top. See picture in documents of activity # 6899555.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 June 2018 Resolved
Properly labeled children PFD's with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Vessel properly labeled vessel name on all children PFD's.
Sail Rigging › Chainplates › Fasteners
Issued 5 May 2017 Resolved
Ensure Gammon Iron is secured properly.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 30 May 2017
Resolution: Vessel shipwright confirmed gammon iron was properly secured.
Sail Rigging › Deck Hardware › Shackles
Issued 5 May 2017 Resolved
Replace shackle for main sheet double block
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 30 May 2017
Resolution: Shackle replaced with new.
Sail Rigging › Deck Hardware › Shackles
Issued 5 May 2017 Resolved
Replace shackle for foresheet fore boom connection
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 30 May 2017
Resolution: Shackle replaced with new.
Sail Rigging › Running Rigging › Splices
Issued 5 May 2017 Resolved
Repair main sheet standing end thimble
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 30 May 2017
Resolution: Line re-spliced and re-secured around thimble.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 May 2017 Resolved
Replace light line for ring buoy.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 30 May 2017
Resolution: Line replaced with new.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 May 2017 Resolved
Repair inoperable stern navigation light prior to carrying passengers at night or at times of restricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 7 May 2017
Resolution: Operator repaired stern light to the satisfaction of the attending MI.
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2017 Resolved
Maintain vessel records that record the number of passengers debarking on day trips and the names of passengers when debarking from overnight trips.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 May 2017 Resolved
Stencil proper vessel name on children's lifejackets.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Corrected on the spot.
Communications › Public Address System › Loudspeaker
Issued 5 May 2017 Resolved
Provide a PA system that can be heard in all accomodation spaces below decks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2017
Resolved 5 May 2017
Resolution: Corrected during inspection.
Construction/Loadline › Hull › Side Shell
Issued 13 December 2016 Resolved
Repair worm damage as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 21 December 2016
Construction/Loadline › Hull › Keel
Issued 13 December 2016 Resolved
Replace stop plug on rudder works.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 21 December 2016
Construction/Loadline › Hull › Side Shell
Issued 13 December 2016 Resolved
Repair planks on port and starboard sides above waterline as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 21 December 2016
Sail Rigging › Running Rigging › Blocks
Issued 13 December 2016 Resolved
Replace shackle for fore sheet traveler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 12 January 2017
Sail Rigging › Running Rigging › Shackles
Issued 13 December 2016 Resolved
Replace fore sheet swivel pin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 12 January 2017
Construction/Loadline › Hull › Side Shell
Issued 13 December 2016 Resolved
Pull 16 fasteners for inspection as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 15 December 2016
Construction/Loadline › Hull › Keel
Issued 13 December 2016 Resolved
Pull one (1) keel bolt for inspection as discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 15 December 2016
Sail Rigging › Spars › Gaffs/Jaws/Saddles/Fittings
Issued 13 December 2016 Resolved
Provide third party and company rigging survey reports.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 12 January 2017
Construction/Loadline › Hull › Side Shell
Issued 13 December 2016 Resolved
Conduct underway sea trial with marine inspector at least 24 hours after refloating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 21 December 2016
Engineering › Fuel Oil Service System › Pump
Issued 16 October 2016 Resolved
Provide mechanics report for reduction in propulsion prior to sailing.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 24 October 2016
Resolution: Received email attesting to dirty primary fuel filter.
Operations/Management › Vessel Activity › Underway
Issued 16 October 2016 Resolved
Complete satisfactory sea-trial prior to sailing.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 30 October 2016
Resolution: Completed satisfactory sea-trial.
Documentation › Logs/Records › Report of Marine Accident, Injury or Death
Issued 16 October 2016 Resolved
Provide CG-2692 within 5 days of incident.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 17 October 2016
Resolution: Received CG-2692.
Sail Rigging › Deck Hardware › Shackles
Issued 20 June 2014 Resolved
Replace all eye bolts and shackles on deck as indicated in kind.
Action required: 705 - Other - as specified
Due 20 August 2014
Resolved 12 September 2014
Resolution: Received email with pictures showing evidence of the repairs made to vessel''s deck hardware.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 17 May 2012 Resolved
Provide a mechanical, manually operated device to assist in launching survival craft.
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 26 June 2012
Resolution: Provided device & proved proper operatiopn.
Sail Rigging › Sails › Stitching
Issued 17 May 2012 Resolved
Repair or replace foresail.
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 26 June 2012
Resolution: Replaced fore-sail.
Electrical › Electric Supply System (service) › Cable
Issued 17 May 2012 Resolved
Remove dead-end wiring in engine room.
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 26 June 2012
Resolution: Removed dead end wires.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 May 2012 Resolved
Provide exhaust pipe lagging in way of exhaust flange.
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 26 June 2012
Resolution: Provided lagging.
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 May 2012 Resolved
Provide appropriate life jacket placards.
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 26 June 2012
Resolution: Provided placard.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 May 2012 Resolved
Provide current radio safety certificate.
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 11 July 2012
Stability › Watertight Integrity › General
Issued 7 February 2011 Resolved
Make vessel available for internal inspection of the hull due to grounding.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2011
Resolved 7 February 2011
Resolution: Completed internal examination of all compartments reference IO case #3945609
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 31 January 2011 Resolved
Remove rot in foremast IWO port trestle cheek and renew to original conditon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2011
Resolved 16 March 2011
Resolution: CG-835 cleared & a new def has been issued to address the problem see def check case # 3966027.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 31 January 2011 Resolved
Renew to original condition top foremast IWO shrouds and forestay.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2011
Resolved 16 March 2011
Resolution: CG-835 are cleared & a new def has been issued to address the problem see def check case # 3966027.
Construction/Loadline › Hull › Transverse Frame
Issued 9 December 2008 Resolved
Clean and treat oil soaked wood in fwd berthing compartment and wood in chain lokcer.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 11 February 2009
Resolution: Fwd berthing compartment and chain locker cleaned and treated.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 12 June 2008 Resolved
Renew Survival Craft hydrostatic release unit approved under series 160.062 or 160.162.
Action required: 705 - Other - as specified
Due 26 June 2008
Resolved 19 June 2008
Resolution: New hydrostatic unit installed on liferaft.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 June 2008 Resolved
Provide a sufficient number of Alcohol testing devices on board the vsl to test each individual involved in a Marine Casualty for the presence of alcohol as required by 46 CFR 4.06-15.
Action required: 705 - Other - as specified
Due 26 June 2008
Resolved 19 June 2008
Resolution: Test kits purchased and on board vsl.
Documentation › Certificates/Documents › FCC SSL
Issued 30 May 2007 Resolved
Provide current FCC Radio Operator Permit for Master [name withheld]
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 26 June 2007
Resolution: Current FCC Radio Operator Permit provided for Master [name withheld]
Fire Fighting › Ventilation Systems › Ducts
Issued 30 May 2007 Resolved
Repair or replace Engine room ventilation in way of portside pantry I.A.W. 46 CFR 182.465.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 26 June 2007
Resolution: Engine room ventilation repaired.
Stability › Watertight Integrity › General
Issued 30 May 2007 Resolved
Make bulkhead penetrations watertight in way of aftermost bulkhead I.A.W 46 CFR 179.320.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 26 June 2007
Resolution: Bulkhead penetrations watertight.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 30 May 2007 Resolved
Install metal supports for cable and wiring in way of overnight accommodation space I.A.W 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 26 June 2007
Resolution: Metal supports for cable and wiring provided.
Engineering › Fuel Oil Service System › Piping
Issued 30 May 2007 Resolved
Replace fuel piping system for generator I.A.W 46 CFR 182.450 and 182.710. Must be completed prior to use of vessels generator.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 26 June 2007
Resolution: Fuel piping system for generator replaced.
Accommodation/Occupational Safety › Potable Water System › General
Issued 30 May 2007 Resolved
Submit plans for the installation of the propane water heater system forward of the galley. Propane water heater may not be used until plans are approved.
Action required: 705 - Other - as specified
Due 1 July 2007
Resolved 14 April 2010
Resolution: Vessel has installed electric hot water heaters which had gone though LA-LB plan approval in 2007.
Deck/Cargo › Cargo Stowage › General
Issued 30 May 2007 Resolved
Remove spare propane cylinders from deck.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 26 June 2007
Resolution: Spare propane cylinders removed from deck.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 June 2006 Resolved
Provide proof of EPRIB registration. Vessel is restricted to less than three miles from the coastline. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 24 August 2006
Resolution: Vsl faxed proof of EPRIB reg.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 June 2006 Resolved
Repair/replace emergency light in main berthing, 46 CFR 183.432.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 30 October 2006
Resolution: Repaired emergency light in main berthing.
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 June 2006 Resolved
Provide lifejacket donning placard for all types of lilfejackets onboard, 46CFR 185.516 (a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 30 October 2006
Resolution: Replaced lifejackets to make all the same. Lifejacket donning placard covers all lifejackets onboard.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 June 2006 Resolved
Properly log EPIRB monthly test. 46 CFR 185.728 (a).
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 30 October 2006
Resolution: Properly logging EPIRB monthly test.
Navigation › Piloting/Steering › Marine Charts
Issued 20 June 2006 Resolved
Provide updated/current charts, 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 30 October 2006
Resolution: Current charts provided.
Engineering › Bilge Water Management System › Piping
Issued 20 September 2005 Resolved
Remove PVC from bilge piping in engineroom.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2005
Resolution: Removed.
Construction/Loadline › Hull › Bottom Plating
Issued 20 September 2005 Resolved
Rechalk seams as marked by attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2005
Resolution: Re-caulked.
Construction/Loadline › Structures › Deck Plating
Issued 20 September 2005 Resolved
Local treat angel hair rot on main deck inside accommodation spaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2005
Resolution: Treated.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 September 2005 Resolved
Repair main engine exhaust system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2005
Resolved 27 September 2005
Resolution: Repaired.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 September 2005 Resolved
Provide shaft reading to marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2015
Resolved 15 September 2015
Resolution: Shaft readings provided, no exceptions noted.
Construction/Loadline › Structures › Deck Plating
Issued 20 September 2005 Resolved
Pull fasteners as marked and make available to marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2005
Resolution: Fastners pulled and examined, normal wear noted.
Construction/Loadline › Hull › Keel
Issued 20 September 2005 Resolved
Provide keel bolt examination to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 21 September 2005
Resolution: Vessel provided keel bolt xrays. Keel bolts SAT.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 June 2005 Resolved
Repair/Replace lagging on exhaust so that exposed area is covered.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 15 August 2005
Resolution: Repaired lagging on exhaust.
Lifesaving › Lifejacket/PFD (General)
Issued 12 June 2003 Resolved
Failed 19 kapok lifejackets. Vessel is limited to 55 adult passengers until corrected.
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: Received receipt by fax for the purchase of 24 lifejackets.
Communications › Radio Communications
Issued 16 April 2002 Resolved
Post emergency broadcast placard at operating station.
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Placard provided.
Lifesaving › Buoyant Apparatus
Issued 16 April 2002 Resolved
Mount IBA instructions near IBA.
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Instructions mounted.
Electrical › Lighting (service)
Issued 16 April 2002 Resolved
Remove inoperable light fixture in stbd pax head & replace. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Fixture removed & replaced.
Fire Fighting › Remote Fuel Shutoff
Issued 16 April 2002 Resolved
Label emergency fuel shut-offs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Fuel shut-offs labeled.
Lifesaving › Rescue Boat
Issued 16 April 2002 Resolved
Mark rescue boat with vessel name, max occupancy and retro-tape. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Rescue boat marked.
Fire Fighting › Structural Fire Protection - General
Issued 16 April 2002 Resolved
Remove wood cabinet above open flame stove and provide fire retardent material between stove and wood bulkhead. LEGACY COMPONENT DESC: Cooking Area
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2002
Resolved 17 April 2002
Resolution: Cabinet removed and flame retardent material provided where required.
Fire Fighting › Firemans Outfit
Issued 16 April 2002 Resolved
Place vessel name on fire axe. LEGACY COMPONENT DESC: Axe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Vessel name on fire axe.
Electrical › Electrical Distribution System (service)
Issued 16 April 2002 Resolved
Insulate electrical connectors on windlass motor solenoid box in crew berthing. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Connectors insulated.
Lifesaving › Lifejacket/PFD (General)
Issued 16 April 2002 Resolved
Provide new vessel name on all lifejackets. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Lifejackets marked with new name.
Lifesaving › Lifejacket/PFD (General)
Issued 16 April 2002 Resolved
Properly label all lifejacket storage containers. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Containers labelled.
Lifesaving › Lifejacket/PFD (General)
Issued 16 April 2002 Resolved
Provide life jacket donning placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Placard provided.
Electrical › Electrical Distribution System (service)
Issued 16 April 2002 Resolved
Provide metallic supports for all wire runs in engine room and space above E/R. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Supports provided.
Electrical › Electrical Distribution System (service)
Issued 16 April 2002 Resolved
Re-wire aft bilge high level alarm. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2002
Resolved 17 April 2002
Resolution: Alarm re-wired.
Engineering › Bilge Water Management System
Issued 16 April 2002 Resolved
Install bilge high level alarm in 2nd space from bow.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2002
Resolved 17 April 2002
Resolution: Alarm installed.
Lifesaving › Lifejacket/PFD (General)
Issued 16 April 2002 Resolved
Vessel restricted to 55 total persons onboard until additional life jackets are provided. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Resolution: Additional life jackets provided.
Fire Fighting › Structural Fire Protection - General
Issued 16 April 2002 Resolved
Remove temporary fire retardent material between stove and wood bulkhead and replace with permanent stainless steel material.. LEGACY COMPONENT DESC: Cooking Area
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 12 June 2003
Resolution: Permanent stainless steel was installed above the stove.
Construction/Loadline
Issued 26 September 2001 Resolved
Provide proof of operation all bilge high level alarms and the bilge pump.
Condition: Unknown
Due 15 October 2001
Resolved 26 November 2001
Construction/Loadline
Issued 26 September 2001 Resolved
Repair wood rot in galley bulkhead.
Condition: Unknown
Due 15 October 2001
Resolved 26 November 2001
Lifesaving
Issued 26 September 2001 Resolved
Provide 100% Lifesaving equipment for 85 total persons on board. Vessel islimited to 45 person until requirement is meet.
Condition: Unknown
Due 1 January 2002
Resolved 8 April 2002
Resolution: Vessel installed 50 person IBA (VIKING serial # 50RDV-R06202)
Engineering
Issued 26 September 2001 Resolved
Repair maine engine exahust leak
Condition: Unknown
Due 15 October 2001
Resolved 26 November 2001
Engineering
Issued 26 September 2001 Resolved
Install and label emergency fuel shut offs IAW 46 CFR 182.455.
Condition: Unknown
Due 15 October 2001
Resolved 26 November 2001
Construction/Loadline
Issued 13 August 2001 Resolved
Replace bilge high-level alarm in forepeak compartment. Item to be completed prior to carrying passengers for hire.
Condition: Unknown
Due 15 August 2001
Resolved 31 August 2001
Electrical
Issued 11 June 2001 Resolved
Provide proper plans for the generator system. This includes an electricaldiagram and list of equipment, information or data on the generator and fuel system diagram listing types of hoses.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 11 June 2001 Resolved
Prove operation of the audible high blge alarm.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Documentation
Issued 11 June 2001 Resolved
Provide a current FCC station License.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE TWO ADDITIONAL ADULT LIFEJACKETS. VESSEL IS LIMITED TO THE CARRIAGEOF 86 TOTAL PERSONS UNTIL DEFICIENCY IS CORRECTED.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Electrical
Issued 6 April 2000 Resolved
PROVIDE AN ELECTRICAL WIRING DIAGRAM FOR THE INSTALLED GENERATOR.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE AND INSTALL A WATERLIGHT FOR THE BUOYANT APPARATUS.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE AND INSTALL A PROPER PAINTER AND WEAK LINK FOR THE BOUYANT APPARATUS.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE AND INSTALL A LANYARD TO THE WATERLIGHT ON THE LIFERING OF PROPER LENGTH.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Construction/Loadline
Issued 19 August 1999 Resolved
Install draft markings per 46 CFR 185.602
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 19 August 1999 Resolved
Repair area of keel in way of worm damage
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 19 August 1999 Resolved
Install new thru hull spool piece in way of port side MSD overboard valve.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 19 August 1999 Resolved
Remove fasteners as indicated for examination.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Electrical
Issued 19 August 1999 Resolved
Remove inverter wiring in way of stbd bulkhead fwd engineroom.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Engineering
Issued 19 August 1999 Resolved
Conduct NDT examination of propeller shaft in way of key way.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 19 August 1999 Resolved
Renew frame to floor fasteners in way of frame #36.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 19 August 1999 Resolved
Repair as new worm damage in deadwood in way of 1st scarf from stem on wormshoe. This item to be completed at next hull exam due to current blocking schedule.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Engineering
Issued 19 August 1999 Resolved
Renew propeller shaft due to fracture in key way. If unable to obtain replacement prior to refloat deadline vsl may use old shaft until 10 sept 1999 when the vsl must be hauled and shaft renewed.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Accommodation/Occupational Safety
Issued 19 August 1999 Resolved
Repair as new bulwarks port side in way of collision damage.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 19 August 1999 Resolved
Repair as new transom in way of rot.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Navigation
Issued 29 October 1997 Resolved
NEXT HULL EXAM RE WORK ALL PENTLE BEARINGS.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Construction/Loadline
Issued 29 October 1997 Resolved
After the vessel is back in the water contact the local Coast Guard Marine Inspection office and have a follow-up ride after drydock done.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Lifesaving
Issued 9 July 1997 Resolved
Prove proper operation of stbd ring buoy water light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Lifesaving
Issued 9 July 1997 Resolved
Provide CG approved waterlight for use w/ life float.
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Engineering
Issued 9 July 1997 Resolved
Remove excess oil from engine oil drip pan.
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Unknown
Issued 1 May 1995 Resolved
Waste management log missing.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Navigation
Issued 1 May 1995 Resolved
FCC regulations and T-boat regulations missing. Charts were not corrected for area of operation.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Fire Fighting
Issued 1 May 1995 Resolved
Fire pump pressure gauge on port side inoperative. Must be able to indicate 60psi.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Navigation
Issued 29 April 1994 Resolved
PROVIDE UPDATED COMPASS DEVIATION CARD.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 29 April 1994 Resolved
REMOVE ALL OIL FROM BILGES.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 29 April 1994 Resolved
PROVIDE STRAINERS FOR ALL BILGE PIPING FITTINGS.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Electrical
Issued 29 April 1994 Resolved
PROVIDE BULBS FOR ALL LIGHTING FIXTURES.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
PROVIDE MEANS OF SECURING O/B DISCHARGE VALVE FOR MSD.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Lifesaving
Issued 29 April 1994 Resolved
REPAIR/REPLACE LIFE RESCUE BOAT.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Navigation
Issued 29 April 1994 Resolved
PROVIDE UPDATED/CORRECTED CHARTS OF LOCAL OPERATING AREA THROUGH LATEST LOCAL NOTICE TO MARINERS.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Navigation
Issued 29 April 1994 Resolved
PROVIDE UPDATED/CORRECTED PUBLICATIONS: COAST PILOT AND LIGHT LIST, THROUGHLATEST LOCAL NOTICE TO MARINERS.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Documentation
Issued 29 April 1994 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH THE REQUIREMENTS IN 46CFR16 FOR CHEMICAL (DRUG) TESTING OF CREW INCLUDING RANDOM TESTING.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Lifesaving
Issued 22 April 1993 Resolved
RETIE MANLINES AND PROPERLY ATTACH PAINTER TO BUOYANT APPARATUS AND LIFEFLOAT.
Condition: Unknown
Due 22 May 1993
Resolved 14 May 1993
Lifesaving
Issued 22 April 1993 Resolved
REPLACE WEAK LINK ON THE BUOYANT APPARATUS AND LIFEFLOAT WITH ONE OF PROPERSIZE.
Condition: Unknown
Due 22 May 1993
Resolved 14 May 1993
Lifesaving
Issued 22 April 1993 Resolved
PROVIDE 44 ADDITIONAL COAST GUARD APPROVED ADULT TYPE 1 PFD's PRIOR TO CARRYING MORE THAN 44 ADULTS.
Condition: Unknown
Due 22 May 1993
Resolved 14 May 1993
Lifesaving
Issued 22 April 1993 Resolved
PROVIDE 5 ADDITIONAL COAST GUARD APPROVED CHILD SIZE TYPE 1 PFD's PRIOR TO CARRYING MORE THAN 4 CHILDREN.
Condition: Unknown
Due 22 May 1993
Resolved 14 May 1993
Documentation
Issued 22 April 1993 Resolved
HAVE A WEIGHT ANALYSIS CONDUCTED BY A NAVAL ARCHITECT TO INCLUDE, BUT NOT LIMITED TO, THE POTABLE WATER TANK MODIFICATIONS, INSPALLATION OF THE NEW HOLDING TANK, AND SAIL RENEWAL ABOARD THE VESSEL.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Documentation
Issued 22 April 1993 Resolved
PROVE PARTICIPATION IN A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Accommodation/Occupational Safety
Issued 22 April 1993 Resolved
PROVIDE A FUNCTIONAL POTABLE WATER SYSTEM FOR THE VESSEL.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Documentation
Issued 22 April 1993 Resolved
PROVIDE ONBOARD A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 22 May 1993
Resolved 14 May 1993
Construction/Loadline
Issued 22 April 1993 Resolved
RE-PAINT VESSEL'S NAME ON PORT BOW.
Condition: Unknown
Due 22 May 1993
Resolved 13 May 1993
Lifesaving
Issued 22 April 1993 Resolved
REPLACE, STENCIL WITH VESSEL'S NAME AND LASH PADDLES TO 25 MAN LIFEFLOAT.
Condition: Unknown
Due 22 May 1993
Resolved 14 May 1993
Lifesaving
Issued 22 April 1993 Resolved
RENEW RETROREFLECTIVE TAPE ON LIFEFLOAT.
Condition: Unknown
Due 22 May 1993
Resolved 14 May 1993
Documentation
Issued 12 March 1993 Resolved
INSTALL DRAFT MARKS OR LOADING MARKS AS DESCRIBED IN 46 CFR 185.30-3 PRIOR TO COMPLETION OF THE NEXT ROUTINE DRYDOCKING.
Condition: Unknown
Due 12 March 1993
Resolved 12 March 1993
Documentation
Issued 24 April 1992 Resolved
PROVIDE CURRENT RADIO STATION LICENSE.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Documentation
Issued 24 April 1992 Resolved
PROVIDE CURRENT FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Lifesaving
Issued 24 April 1991 Resolved
REPLACE 2 RING BUOYS AND WATERLIGHT ON LIFEFLOAT. VESSEL MAY NOT OPERATE WITH PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Accommodation/Occupational Safety
Issued 24 April 1991 Resolved
REPAIR MARINE SANITATION DEVICE PUMPS. VESSEL LIMITED TO RUNS OF 30 MINUTES OR LESS UNTIL CORRECTED.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
REPAIR LEAK ON STARBOARD FIRE PUMP AND PROVE OPERATION AT 60 PSI.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
REPAIR FIRE AXE BRACKET.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Accommodation/Occupational Safety
Issued 24 April 1991 Resolved
PROPERLY SECURE LADDER IN THE GALLEY.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Navigation
Issued 24 April 1991 Resolved
PROVIDE TIDE AND CURRENT TABLES.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Deck/Cargo
Issued 24 April 1991 Resolved
REPLACE CRACKED STEPS ON RATLINES TO FOREMAST: 2 STEPS ABOVE STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Construction/Loadline
Issued 24 January 1991 Resolved
Repair canvas cover for main hatch in order to provide watertight integrityfor entry way and main cabin.
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Construction/Loadline
Issued 24 January 1991 Resolved
Caulk chartroom's forward bulkhead in order to make it watertight.
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Accommodation/Occupational Safety
Issued 26 April 1990 Resolved
RENEW CRACKED GLASS IN PASSENGER COMPARTMENT SKYLIGHT.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Fire Fighting
Issued 26 April 1990 Resolved
RENEW PRESSURE GAUGES ON DISCHARGE SIDE OF BOTH POWER FIRE PUMPS AND PROVE 60 PSI OUTPUT PRESSURE.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Accommodation/Occupational Safety
Issued 26 April 1990 Resolved
CAP UNUSED THROUGH-HULL FITTINGS UNDER THE BATHTUB.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Lifesaving
Issued 27 April 1989 Resolved
PROVIDE WATERLIGHT FOR RING BUOY.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Lifesaving
Issued 27 April 1989 Resolved
PROVIDE 3 DAY AND 3 NIGHT FLARES.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Lifesaving
Issued 27 April 1989 Resolved
PROPERLY SECURE WATERLIGHT TO LIFEFLOAT.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Fire Fighting
Issued 27 April 1989 Resolved
SERVICE PORTABLE FIREFIGHTING EXTINGUISHERS.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Lifesaving
Issued 12 May 1988 Resolved
REPLACE PENDANTS ON BOUYANT APPATUS.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Electrical
Issued 12 May 1988 Resolved
MAKE PROPER REPAIRS TO ALTERNATOR MOUNTING BRACKET.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Construction/Loadline
Issued 29 October 1987 Resolved
REPAIR WORM BORER DAMAGE ON STERN WORM SHOE AT NEXT DRY DOCKING. STERN WORM SHOE WAS DIRECTLY ON DOCKING BLOCKS DURING THE PREVIOUS DRY DOCKING.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987

Casualty record · 4

6 February 2011Routine · role: Involved in a Marine Casualty · activity 3941862
3 September 2015Routine · role: Involved in a Marine Casualty · activity 5727130
16 October 2016Routine · role: Involved in a Marine Casualty · activity 6043894
10 April 2021Routine · role: Involved in a Marine Casualty · activity 7212623
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.