Inspection record

Last inspected 22 July 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB2619
233158
Flag
UNITED STATES
Maury page id
psix-233158

Documentation record

Registered dimensions (L × B × D)86.2 ft × 24.3 ft × 8.4 ft
Registered tonnagegross 98 / net 86
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMELBOURNE SMITH · SAN DIEGO, CA, UNITED STATES · built 1984
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSACRAMENTO, CA
Endorsements, as the file codes themcw_un, rec, reg
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
130 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 28 inspections, each with its date, unit and type; 45 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

22 July 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8192151
24 June 2025 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8165754
28 July 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7970835
25 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7942459
5 June 2023 Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7704065
23 May 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7695048
3 April 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7661989
1 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7421428
23 September 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7318836
23 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7233422
20 November 2020 Internal Structural Exam · Drydock Extension · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7099364
14 October 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7076061
15 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6953742
15 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6834630
25 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6724829
13 December 2018 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6597410
28 November 2018 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6588542
14 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6540548
9 August 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6505860
26 July 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6492174
6 June 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6435731
7 May 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6408013
30 November 2017 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6315474
2 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6299765
3 April 2017 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6116818
15 November 2016 Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6041361
27 October 2016 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6030841
8 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5901084

Deficiency record · 45

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 July 2025 Resolved
Vessels on Oceans route must have an interconnected detection and alarm system. Vessel is restricted to a limited coast wise route via this 835 until the updated COI is routed and signed.46 CFR 181.450
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Witnesses satisfactory operation
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 July 2025 Resolved
A vessel of more than 65 feet must carry at least one rescue boat. Vessels rescue boat stopped operating during the MOB drill 46 CFR 180.210
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2025
Resolution: Witnessed satisfactory operation / correction
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 July 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Signs of leakage observed on the generator. Find leak and repair. Notify local OCMI once complete and ready for follow-up inspection. 46 CFR 182.100.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2025
Resolution: Witnessed satisfactory operation / correction
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 July 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in locker on starboard side in salon area. Remove dead end wiring and update electrical plans. Notify local OCMI once complete and ready for follow-up inspection.46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2025
Resolution: Witnessed satisfactory operation / correction
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 22 July 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI found the aft bunk room; starboard side deck was not sealed properly allowing light to shine in from the outside. Make the compartment watertight and notify local OCMI once complete and ready for follow-up inspection. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Witnessed satisfactory operation / correction
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 July 2025 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date it is installed. The HRU had an expiration date of May 2023.46 CFR 185.740
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2025
Resolution: Witnessed satisfactory operation / correction
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2025 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050. Vessels grab lines were frayed beyond serviceability. Replace ring buoy and retro reflective tape 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2025
Resolution: Witnessed satisfactory operation / correction
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 22 July 2025 Resolved
Observed VHF radio not receiving GPS coordinates. Vessel is to have GPS installed into VHF.46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2025
Resolution: Witnessed satisfactory operation / correction
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2025 Resolved
Mousing on Running Back stay and Preventer on Main Mast was missing. Corrected mousing on preventer on the spot.46 CFR 176.802
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2025
Resolution: Witnessed satisfactory operation / correction
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 22 July 2025 No resolution recorded
Vessels with overnight accommodations for passengers must submit plans for the installation and use of monitoring devices to ensure the wakefulness of the watchmen that patrol the vessel during nighttime, whether or not the vessel is underway, to guard against, and give alarm in case of, fire, man overboard, or other dangerous situation. Vessel cannot have passengers in the accommodation spaces until such time that the roving watch alarm is installed and tested in the presence of the USCG. 46CFR185.410
Action required: 705 - Other - as specified
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 June 2024 Resolved
Observed VHF radio not receiving GPS coordinates. Vessel is to have GPS installed into VHF. To be rectified by 25 July 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 8 July 2024
Resolution: Received an email with pictures from the vessel POC showing that the VHF is connected to the GPS
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 June 2024 Resolved
Vessel’s emergency lighting did not automatically operate during a loss of power. Vessel is to make repairs to meet requirement. To be rectified by 25 July 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 12 July 2024
Resolution: Witnessed satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 June 2023 Resolved
One area on the starboard side and one area on the port side have become uncaulked. The areas need to be sanded to good wood, re caulked and sealed.
Action required: 705 - Other - as specified
Resolved 7 June 2023
Resolution: For D/D credit
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 April 2022 Resolved
Fire pump outlet must be fitted with a pressure gauge. Pressure gauge on pump outlet was not operational. Must replace/repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2022
Resolved 2 May 2022
Resolution: Replaced with new pressure gauge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Operator station ring life bouy body found ripped and deteriorated.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 3 August 2021
Resolution: verified replaced life buoy during def check. [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 June 2021 Resolved
Each vessel certificated to operate on an Oceans route must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board (cold water), or 67% of the total number of persons permitted on board (warm water). All three inflatable life rafts were not onboard during USCG Annual Inspection.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 3 August 2021
Resolution: verified 02 replaced IBA's onboard and properly stowed during def check. [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 June 2021 Resolved
Aft quarterdeck PORT and STBD side rails not of sufficient height.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 3 September 2021
Resolution: Temp railing meets CG standards. DEM
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 October 2020 Resolved
Vessel did not have proof of drug testing program available. Make drug testing consortium paperwork for 2020 available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2020
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 14 October 2020 Resolved
Crew was unable to demonstrate proper operation of emergency steering. Demonstrate satisfactory emergency steering drill in the presence of a USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 October 2020 Resolved
Liferaft hydrostatic releases were expired. Provide valid hydrostatic releases for each liferaft prior to operating on Oceans/Coastwise routes. From 01Jan to 28Feb (cold water months) - Vessel is restricted to Lakes, Bays, and Sounds route, not to exceed 01 NM from shore. From 01Mar to 31Dec (warm water months) - Vessel is restricted to Limited Coastwise route, not to exceed 03 NM from shore.
Action required: 705 - Other - as specified
Resolved 3 August 2021
Resolution: Verified validated hydrostatic release unit; expiry date of JULY 2023. [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 October 2020 Resolved
Vessel was unable to demonstrate adequate pressure on either of the 02 required fire pumps. Prove that both fire pumps can provide 60 PSI or 50 GPM of pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
Resolution: Vessel replaced the pressure gauge with a new one that presented an appropriate pressure.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 14 October 2020 Resolved
Vessel's crew were unable to demonstrate satisfactory operation of the vessel's SSB radio. Demonstrate proper operation of the SSB radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 October 2020 Resolved
Vessel's magnetic compass deviation table was missing. Provide an updated magnetic compass deviation table for the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 3 August 2021
Resolution: Verified updated vessel deviation table / card dated AUG 2021; [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 October 2020 Resolved
Provide a guard for the serpentine belt on the main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020 Resolved
Clean debris from the fuel filter flame impingement bowls.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020 Resolved
Close the identified gauge box in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 October 2019 Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side. Mark emergency escape hatch with proper marking on both sides.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Marked.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 October 2019 Resolved
Replace defective emergency light in captain cabin.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Battery replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2019 Resolved
Repair outlet labeled "do not use".
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2019 Resolved
Replace ruptured hose at bilge pick-up in fore peak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2019
Resolved 11 July 2019
Resolution: Hose section was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 June 2019 Resolved
Replace iodine swabs, 4" & 2" bandage compresses in first aid kit.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2019
Resolved 11 July 2019
Resolution: The above items were replaced with new supplies.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2019 Resolved
Repair leaking seal on fire pump housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 July 2019
Resolution: Fire pump gasket / seal was replaced and operationally tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2019 Resolved
Tighten shaft packing gland to reduce water ingress.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 July 2019
Resolution: Shaft packing was tightened, no leaking was observed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2019 Resolved
Replace battery and broken latch on fwd lifebouy light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 July 2019
Resolution: Lifebouy light was replaced in-kind.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 25 June 2019 Resolved
Clean out sorbent pads from under main engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 July 2019
Resolution: Sorbent pads were changed out with new pads.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2019 Resolved
Mouse schackles on sail rigging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 July 2019
Resolution: All shackles were properly moused.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 25 June 2019 Resolved
Clean grease/lint from galley uptake.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 July 2019
Resolution: New filters were installed on vent hood.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 25 June 2019 Resolved
Provide securing latch on oven door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 July 2019
Resolution: Securing latch was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 25 June 2019 Resolved
Replace deck light (window) on stbd side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 31 July 2019
Resolution: Picture received.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018 Resolved
LENGTH DIFF: greater/smaller than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 November 2018
Resolution: Verified in VIVS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2018 Resolved
Prove proper operation of fuel supply to engine.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 26 July 2018
Resolution: Properly set fuel valve, engine tested SAT.
Documentation › Certificates/Documents › FCC SSL
Issued 6 June 2018 Resolved
Provide valid FCC SSL.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: Provided copy of license.
Engineering › Bilge Water Management System › Pump
Issued 2 November 2017 Resolved
Prove proper operation of bilge/fire pump.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Removed/replaced pump, tested Sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 June 2016 Resolved
Renew fire extinguishe bracket in at the ladder in the engine room.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 14 June 2016
Resolution: A new extinguisher bracket was installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 June 2016 Resolved
Mount fire extinguisher in STBD deck locker.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 14 June 2016
Resolution: Bracket was mounted within the locker.