STAR OF INDIA is a 1863 in-service – inspected. The Coast Guard has recorded 16 inspections since 2016, most recently in November 2025, along with 31 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 21 November 2025.

Built
1863
Last inspected
21 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 November 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

484496
Flag
UNITED STATES
Maury page id
psix-484496

Documentation record

Tonnage as PSIX records it1197 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

21 November 2025 Underwater Inspection in lieu of Drydock
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8306902
13 November 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8268205
24 September 2024 Internal Structural Exam · In-Service Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8009502
9 November 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7834513
20 July 2023 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7747773
20 October 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568904
10 June 2022 Underwater Inspection in lieu of Drydock
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8060379
26 August 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7297207
30 July 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7011584
14 February 2020 Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6909134
16 July 2019 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6737052
13 December 2018 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6597402
24 July 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6489323
6 July 2017 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6199871
27 October 2016 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6034240
12 July 2016 Annual Inspection · Attraction Vessel Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5938143

Deficiency record · 31

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 November 2025 Resolved
Ships service generator is inoperable. Restore generator to operational status. 46 CFR 111.10-3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2025
Resolution: Vessel generator works as intended.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2025 No resolution recorded
Sections of the fire main system were found renewed / replaced with non metallic piping. Fire main piping on Subchapter H vessels must comply with Subchapter F materials. Replace fire main sections in kind of what was previously removed and the remainder of the fire main or submit repair proposal for approval of alternate repairs. 46 CFR 76.10-15(a).
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 November 2025 No resolution recorded
Observed sections of non marine grade wiring. If the vessel intends to continue operation as a CROD, replace all non marine grade wiring with approved marine grade wiring in accordance with Subchapter J. 46 CFR 111.60-11
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2025 Resolved
Ring buoy light was found inoperable. Replace battery housing and return light to operational status. 46 CFR 78.60-1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 November 2025
Resolution: Witnessed corrected deficiencies.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 September 2024 Resolved
Vessel provided a third party report indicating areas of concern throughout the vessel rigging. Provide plan of action and proposal to investigate areas of concern and follow up repair proposal once extent of damage on each component has been identified. 46CFR71.55
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2024
Resolution: Received a list of work list items museum will work on over the course of there preventative maintenance
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 September 2024 Resolved
Vessel did not have illuminated exit signs and apparent suitable signs in red letters ‘EMERGENCY EXIT”. Have exit signs posted and suitable sign for EMERGENCY EXIT.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2024
Resolution: Received pictures of illiminated exit signs
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 September 2024 Resolved
Vessel has many areas of wasted deck planks providing a lot of areas that pose a risk for slips, trips and falls. Submit repair proposal and plan to address all areas of the deck the pose a risk to passenger safety.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2024
Resolution: Received a list of work list items museum will work on over the course of there preventative maintenance
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 September 2024 Resolved
Submit plan and timeline to replace identified blocks found cracked on the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2024
Resolution: Received a list of work list items museum will work on over the course of there preventative maintenance
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 July 2023 Resolved
Vessel's PA system was found to be inoperable. Repair/replace PA system. Cites: 46 CFR 77.05-1 and 46 CFR 113.50.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 31 July 2023
Resolution: Witnessed satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 July 2023 Resolved
Identified a fuel hose that has inadequate chaffing gear in the gen-set installation. Provide adequate chaffing gear for identified fuel hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 31 July 2023
Resolution: Adequate chaffing gear installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2023 Resolved
Railings on forecastle have only two courses. Add a third course to the forecastle railings. The courses shall be 15 inches apart.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 31 July 2023
Resolution: Added rope course to railing.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2022 Resolved
Remove electrical hazards including electrical dead ended cables, splices in lighting fixtures in the Workshop area and remove power strip in the ships office.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 August 2021 Resolved
Provide Drug and Alcohol Program Consortium approval letter for period 01-30-2021 through 01-30-2022
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 18 October 2021
Resolution: Received email correspondance from [name withheld] regarding DAPI Consortium membership is current. [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 August 2021 Resolved
Found sprinkler head nozzle guard missing in aft store room. Install sprinkler head guard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 20 September 2021
Resolution: DMI verified corrected deficiency. [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2021 Resolved
Vessel generator starting battery storage unit not properly secured / strapped to prevent movement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 20 September 2021
Resolution: DMI verified corrected deficiency. [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 February 2020 Resolved
Clean, treat, plug, coat 4 x holes in plating.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2020
Resolved 24 February 2020
Resolution: Complete
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 February 2020 Resolved
Remove belzona plugs from ice belt, repair and seal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2020
Resolved 24 February 2020
Resolution: Complete.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 February 2020 Resolved
Apply CeramCoat as needed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2020
Resolved 24 February 2020
Resolution: Applied.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 February 2020 Resolved
Repair hole in stbd side aft 1/4 above ice belt.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2020
Resolved 24 February 2020
Resolution: Complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2019 Resolved
Remove wood strapped to generator exhaust pipe.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2019
Resolved 17 July 2019
Resolution: Wood removed from exhaust pipe.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2019 Resolved
Repair broken closure spring to flam locker door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2019
Resolved 17 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Make wire A frame 20 tight and cap.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Wire capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2018 Resolved
Clean fuel filter on generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Fuel filter cleaned.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Lock sewage overboard valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Sewage overboard locked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Plug hole next to sewer valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Hole plugged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2018 Resolved
Replace aft deck life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Lifering replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Provide glass for all port holes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Port hole secured uing closure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Provide safety globes on lights near tracks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Safety globes provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 July 2018 Resolved
Provide specs for fire sprinklers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 25 September 2018
Resolution: Specs for fire sprinklers provided. See documentation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2017 Resolved
Provide proper support to electrical wire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 1 August 2017
Resolution: Provided proper support to electrical wire.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 July 2017 Resolved
Provide smoke detectors in the salon and bosn hole.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 1 August 2017
Resolution: Provided smoke detectors in the salon and bosn hole.