RADIANCE OF THE SEAS

RADIANCE OF THE SEAS is a 2001 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2016, most recently in March 2026, along with 40 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 20 March 2026.

Built
2001
Last inspected
20 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 March 2026
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9195195
Flag
BAHAMAS, THE
Maury page id
psix-23451

Documentation record

Tonnage as PSIX records it90090 - Regulatory (Subpart C or D), Gross Ton
90090 - Convention (Subpart B), Gross Ton
53812 - Convention (Subpart B), Net Ton
10759 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 36

20 March 2026 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8327666
23 September 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8241248
21 September 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8238305
15 July 2025 Security Breach, Potential
Type not classified · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8186947
15 July 2025 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8187052
18 May 2025 PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8138623
30 April 2025 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8126382
28 March 2025 PSC A · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8101167
2 November 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8027695
29 September 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8011150
11 April 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7893918
4 April 2024 COC-CVE Annual
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7888253
23 October 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7811782
1 September 2023 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7786318
31 August 2023 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7785558
6 April 2023 PSC B · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7661591
12 September 2022 COC-CVE Quarterly · PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7557508
9 May 2022 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7448757
11 April 2022 PSC B · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7428568
3 September 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6816233
28 August 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6803149
27 August 2019 ISM Exam · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6796715
17 August 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6862493
2 August 2019 Type not recorded
No type recorded · USCGC MUSTANG (WPB 1310) · USCG Arctic District (CGD-A) · Activity 6771021
6 May 2019 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6673901
4 July 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6482810
21 May 2018 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6420116
3 May 2018 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6402615
4 September 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6261977
29 August 2017 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6254909
1 August 2017 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6227501
31 July 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6233166
26 July 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6223910
11 July 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6205848
5 May 2017 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6138425
20 April 2016 Administrative Inspection · Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5853697

Deficiency record · 40

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 March 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During the operational test of lifeboat no. 2 the engine was unable to clutch astern. 74SOLAS(97) III/19.2 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2026
Resolution: Crew members repaired the clutching system to allow the lifeboat to move astern.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 March 2026 Resolved
After survey of the ship under regulations 7, 8, 9, or 10, has been completed, no change shall be made in the structural arrangements, macinery, equipment, and other items covered by the survey, without the sanction of the administration. Room-in-room construction found in the Carpenter's Workshop such that the office in the back of the workshop did not have direct access to acceptable means of escape and was not provided with an equivalend level of safety (i.e., immediate and clear notification of fire in the surrounding space). 74SOLAS(20) I/11(b) 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2026
Resolution: Crew members removed the door to the room in room configuration and also removed the desk not allowing it to be an office.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 March 2026 Resolved
A gauge indicating the pressure in the system shall be provided at each section stop valve and at a central station. The gauge indicating needle for water-mist stop valves for sections deck 10; fire zone 3 and deck 5; fire zone 4 were found broken such that the gauges did not provide an accurate pressure reading. 74SOLAS01 II-2/12.2.3 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2026
Resolution: Crew members replaced gauges with sp[ares onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 March 2026 Resolved
The marking must enable passengers to identify all the routes of escape and readily identify escape ecits. All escape route signs and fire equipment location markings shall be photoluminescent material or marked by lighting. A section of low location lighting approximately 10 feet long was extinguished in the vicinity of door 3-2-007. 74SOLAS97 II-2/28.1.10 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2026
Resolution: Crew replaced a fuse for the location to fix the light strip that was out for the LLL.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 March 2026 Resolved
Stairways, doorways and corridors shall not be lass than 900mm in clear width. Multiple chairs were stowed in the passageway in the vicinity of door 4-2-005 such that the width of the passageway was less than 900 mm. 74SOLAS97 II-2/28.1.10 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2026
Resolution: Crew removed the furniture stored in the corridor
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2026 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, designed to re-open sufficiently allowing a clear passage of atleast 0.75 m but no more then 1 m. Fire screen door 3-5-015 opened more than 1 m after contacting an object. After contact the door remained fully open and did not attempt to close again. 74SOLAS97 II-2/30.4.2 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2026
Resolution: Crew adjusted the door to close after retracting 1 m.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 March 2026 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40s and no less than 10s. PSCOs observed the following doors failing to close: 02-1-016, 02-7-014, 08-7-006, 08-6-003, and 3-4-006. 74SOLAS97 II-2/30.4.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2026
Resolution: Crew adjusted doors to allow them to shut properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2025 Resolved
The construction of all doors and door in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent materials. PSCO observed galley FSD 12-7-006 and engine room emergency exit FSD 30-06-009 did not fully latch. 74SOLAS97 II-2/30.2 / 10c
Action required: 10 - Deficiency Rectified
Resolved 21 September 2025
Resolution: Door adjusted; all sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 September 2025 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed FST-04-6-01 P and FST 05-6-07 P latches on doors fail when attempted to be opened. Two different members could not be open FST 04-6-01. The handle on FST 05-6-07 fell off when attempting to open doors. 74SOLAS20 II-2/14.1.1 / 10c
Action required: 10 - Deficiency Rectified
Resolved 21 September 2025
Resolution: Latches were adjusted and repaired; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 July 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Vessel reported a complete loss of propulsion of the starboard azipod when shifting from hand steering to aziman mode while mooring up in Sitka Alaska. 74 SOLAS 04 II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2025
Resolution: Received email from class that stated they would be taking no further action as the system was reset and is functioning properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 March 2025 Resolved
07105- The condition of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors or situated. Such doors and door frames shall be constructed of steel or other equivalent materials. PSCO observed the following doors did not latch properly: 04-4-007, 00-3-010, 30-5-005. -74 SOLAS (97). II-2/30.2 -17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2025
Resolved 29 March 2025
Resolution: Crew adjusted doors and rectified deficiency while onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 March 2025 Resolved
07120- In addition to the emergency lighting, the means of escape, including stairways and exits, shall be marked by lighting of photo luminescent strip indicators placed not more than 0.3m (300mm) above the deck at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify escape exits. PSCO observed low location lighting not illuminating at locations: deck 11 - outside hair salon, deck 5 – IVO art and photo gallery, deck 5 - IVO kids department near adventure ocean discovery, deck 3 – IVO FSD 03-6-005 port side. -74 SOLAS (97)II-2/28.1.10 -17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2025
Resolved 29 March 2025
Resolution: Low locaation lighting was corrected prior to CG departure.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 March 2025 Resolved
11129- Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed lifeboat 13 not able to start. -74 SOLAS (97) III/19.2 -17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2025
Resolved 29 March 2025
Resolution: Lifeboat 13 started and passed inspection prior to CG departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 March 2025 Resolved
07126- The arrangement of the storage, distribution and utilization of other flammable oil employed under pressure in power transmission, control and activating systems and heating systems shall be such as to ensure the safety of the ship and persons on board. PSCO observed hydraulic oil leak in PORT & STBD azipods directional control valves. -74 SOLAS (97)II-2/15.4 -17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2025
Resolved 29 March 2025
Resolution: Hydraulic oil leak in PORT and STBD azipod directional control valves was corrected prior to CG departure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 March 2025 Resolved
07105- Fire doors in main vertical zone bulkheads and stairways enclosed, designed to re-open upon contacting an object in its path shall re-open sufficiently to allow a clear passage of at least 0.75 m but no more than 1 m. PSCO observed crash bar on FSD 04-5-004 did not reopen upon contact. -74 SOLAS (97) II-2/30.4.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2025
Resolved 29 March 2025
Resolution: Crew adjusted doors and rectified deficiency while onboard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 March 2025 Resolved
07105- Fire doors in main vertical zone bulkheads and stairways enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCO observed the following doors closing too fast: 04-4-007, 06-6-006. 74 SOLAS (97) II-2/30.4.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2025
Resolved 29 March 2025
Resolution: Crew adjusted doors and rectified deficiency while onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 29 March 2025 Resolved
09211- Machinery, boilers and other pressure vessels shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed steam pipe leak with improvised catch pan to divert leak. -74 SOLAS (04) II-1/26.1 -40ab
Action required: 10 - Deficiency Rectified
Due 29 March 2025
Resolved 29 March 2025
Resolution: Steam leak was corrected prior to completion of exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 November 2024 Resolved
07105 - Fire doors/openings in fire-resisting divisions - Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and be capable with closing with an angle of inclination of up to 3.5 degree opposing closure. PSCO observed FSD 02-5-021 unable to close due to bent/damaged door. 74 SOLAS 97 II-2/30.4.1 / 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2024
Resolution: Crew adjusted door to be able to close fully. USCG officers verified operational condition prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 November 2024 Resolved
11101 - Lifeboats - All lifeboats shall be provided with a rudder and tiller. When a wheel or other remote steering mechanism is also provided, the tiller shall be capable of controlling the rudder in case of failure of the steering mechanism. PSCO observed the emergency steering assembly on Lifeboat Tender #9 was inoperable. 74 SOLAS 97 III/41.7.2 / 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2024
Resolution: Crew adjusted the tiller to be able to operate the emergency steering system. USCG Officers verified operation of emergency steering prior to departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 November 2024 Resolved
07101 - Fire prevention structural integrity - Spaces are classified according to their fire risk as shown in categories (1) to (14) below. Fan room deck 8, MVZ 3 is a category (10) space where storage of combustibles is prohibited. PSCO observed storage of air filters and insulation. 74 SOLAS 97 II-2/26.2.2 / 10ac
Action required: 10 - Deficiency Rectified
Resolved 2 November 2024
Resolution: Vessel crew removed combustibles from the fan room prior to USCG Officers departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 April 2024 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be atleast as effective for resisting fires as the divisions in which they are fitted. PSCO observed FSD5: 03-7-01 1, 03-7-025,03-7-013, 02-3-011, 30-5-005, 1-6-035, 1-6-22,05-7-009, 04-1-015, and 30-5-004 failed to close. 74 SOLAS 97 II-2/301 - 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2024
Resolution: Crew adjusted doors and rectified deficiency while onboard.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 April 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed crew members assigned to lifeboats 2,4, and 6 were not familiar with fuel shut off procedures. 14 SOLAS 20 III/19.2.1 - 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2024
Resolution: Ship's officers trained crew on lack of knowledge while CG was onboard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 April 2024 Resolved
Fire doors in main vertical zone bulkheads and stairway 14 enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40s and no less than lOs. PSCO observed FSD 10-2-01 0, FSD 11-2-002, FSD 12-7-003 closed too fast. 14 SOLAS 97 II-2/30.4.1 - 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2024
Resolution: Crew adjusted doors to appropriate speed while CG was onboard.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 April 2024 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation 11-1/42 or 11-1/43. PSCO observed 05 extinguished embarkation deck lighting on the port side of the vessel. 74 SOLAS 97 III/11.4 - 10C
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2023 Resolved
07106-Any required automatic sprinkler, fire detection and fire alarm system shall be capable of immediate operation at all times. PSCO observed inoperable smoke detector DK00.03.25.007 in guest main laundry space. -74SOLAS(97)II-1/12.1.1 / 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2023
Resolved 23 October 2023
Resolution: Crew repaired smoke alarm and performed satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 October 2023 Resolved
07105-Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have a uniform rate of closure of no more than 40s and no less than 10s. PSCO observed the following fire doors closing to fast: 03-7-011, 02-6-011, Chops Galley, 11-5-004, 12-7-006, 11-7-010, 11-7-007,11-3-010 -74SOLAS(97)II-2/30.4.1 / 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2023
Resolved 23 October 2023
Resolution: Crew repaired and operationally tested all fire doors.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 October 2023 Resolved
11131-Every crew member with assigned emergency duties shall be familiar with this duties before the voyage begins. PSCO observed crew for lifeboat 13 having insufficient knowledge of emergency fuel shutoff locations and bilge system. 74SOLAS(20)III/19.2.1 / 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2023
Resolved 23 October 2023
Resolution: Crew recieved training regarding emergency fuel shutoff and bilge system on the lifeboat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 October 2023 Resolved
07105-The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed fire door 06-5-011 was unable to close due to obstruction and main vertical zone door 02-6-023 was tied off in the open position. 74SOLAS(97)II-2/30.2 / 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2023
Resolved 23 October 2023
Resolution: Crew removed tie back on door 06-6-023 and removed obstruction from door 06-5-011.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 October 2023 Resolved
11101-All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. PSCO observed lifeboat 9/11 and port/starboard rescue boats having damaged retroreflective material. 74SOLAS(20)III/34, LSA Code 1.2.2.7 / 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2023
Resolution: Crew replaced the retro-reflective materials on lifeboats 9/11 and port/starboard rescue boats.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 October 2023 Resolved
07120-The means of escape, including stairways and exits, shall be marked by lighting and photo luminescent strip indicators. PSCO observed approximately 10 feet of low location lighting leading to the main entrance to the spa was inoperable. 74SOLAS(97)II-2/28.1.10 / 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2023
Resolution: Crew repaired low location lighting leading to the entrance of the spa.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 12 September 2022 Resolved
In addition to the emergency lighting required by regulations 11-1/42 and 111/11.5, the means of escape shall be marked by lighting or photoiuminescent strip Indicators placed not more than 0.3 m above the deck at all point of the escape route including angles and Intersections. Deck 2, aft, in vicinity of ECR, emergency lighting was blocked by provisions/spare parts stored In the corridor.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 September 2022
Resolved 13 September 2022
Resolution: Relocated the provisions/ spare parts as to not block the low level lighting.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 12 September 2022 Resolved
Every ship of 400 GT and above, and every ship that is certified to carry 15 persons or more, shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for collecting, storing, processing and disposing of garbage ... Garbage was being stowed in zone whfch was not permitted by the garbage management plan.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 September 2022
Resolved 13 September 2022
Resolution: Moved garbage to its respected zone according to the garbage management plan.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 September 2022 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation 11-1/42 or 11-1/43, as appropriate. 02 embarkation lights were extinguished, one aft of lifeboat #13 and one, port side, fotward of the marine evacuation system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 16 September 2022
Resolution: Electrical team rectified the issue and put all embarkation lights into working order and verified that all of the lights were operational.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 September 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire station in the Windjammer Cafe (deck 11) was blocked with a table and two chairs inhibiting accessibility.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 September 2022
Resolved 13 September 2022
Resolution: Relocated the table and chairs as to where it does not block access to the fire station.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 April 2022 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the doors shall be self-closing...FSD 11-4-001, FSD 02-7-006 would not fully latch once released.
Action required: 10 - Deficiency Rectified
Due 11 April 2022
Resolved 11 April 2022
Resolution: Rectified prior to departure
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 3 May 2018 Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. Call points Dk.04-07.68 004 and Dk 04-07.68 007 are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2018
Resolved 3 May 2018
Resolution: Crew was able to make proper adjustments to the call point resistor and completed a satisfactory re-test.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 1 August 2017 Resolved
0600: Before the ship leaves port and at all times during the voyage,all life-saving appliances shall be in working order and ready for immediate use. The port side rescue boat is not in working order and ready for immediate use. 74 SOLAS (14) Ch. III Reg 20.2
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 29 August 2017
Resolution: Received class report attesting to repairs and proper operation.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 August 2017 Resolved
0615: Passenger ships of 500 gross tonnage and over shall carry at least one rescue boat complying with the requirements of reg. 47 on each side of the ship. The port side rescue boat is non-operational due to flooding of the engine compartment. 74 SOLAS (97) Ch. III Reg 20.2.1 17abc
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2017
Resolution: Received DNV GL acceptance of LB#18 as rescue boat on port side
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 May 2017 Resolved
Indicating units shall, as a minimum, denote the section in which a detector has operated; smoke detectors 04.02.07.36 and 04.02.07.35 are indicating each other's posiiton IAW 74 SOLAS (2001) II-2, 13.1.6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 7 May 2017
Resolution: Vessel provided email stating that deficiency has been rectified along with attached class report and pictures to confirm.
Personnel › Training › Proficiency in Survival Craft
Issued 20 April 2016 Resolved
Def No. 1 (Code: 0695) MES system party shall be trained by participation in a full deployment of a similar system into the water. During the abandonship drill, the PSCO questioned the system party whom exclaimed they have received training but have not participated in a full deployment in the last (3) years. SOLAS (09) 19.3.3.8 - 10c
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 20 April 2016
Resolution: Corrected on the spot.

Ownership record