Records from 2001 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 38
19 May 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8382902
21 April 2025
DAPI Audit · Deficiency Check · Hull Examination · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8109660
24 April 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7904984
24 May 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7708065
20 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7442663
19 May 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7072415
29 July 2020
Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7019637
30 July 2019
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6767800
14 June 2019
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6718293
12 June 2018
Initial Certification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6444246
7 April 2017
Internal Structural Exam · Annual Inspection · Hull Examination · Administrative Inspection · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6105488
20 June 2016
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5913398
12 April 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5852681
27 January 2016
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5804894
5 May 2009
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3468300
2 June 2008
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3225632
10 April 2008
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3181283
7 April 2008
Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3179271
19 September 2007
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3061624
5 September 2007
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3050211
5 September 2007
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3089871
23 July 2007
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3006335
12 July 2007
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2992968
1 May 2007
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2920139
24 April 2007
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2914119
13 March 2007
Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2887421
25 January 2007
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2861785
4 July 2006
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2702778
9 May 2006
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2645280
28 April 2006
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2629559
16 March 2006
Simplified Stability Test · COI Inspection · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2571770
29 March 2005
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2289960
3 April 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2018915
3 May 2003
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1779696
29 May 2002
Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1660587
18 June 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1066935
24 May 2001
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1067149
30 April 2001
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445807
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 April 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.
No alcohol test strips were present on board vessel at time of inspection. Place alcohol test strips on board vessel. [46 CFR 4.06-15(a)(1)]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 19 June 2025
Resolution: Operator provided photo evidence to MI of sufficient alcohol test strips on board vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 3 August 2020
Resolved
Prior to the carriage of passengers, to the satisfaction of the USCG, generate and mount at the operating station, emergency instructions containing the actions to be taken in the event of fire or man overboard conditions which include the particular equipment, arrangement, and operation of each individual onboard the vessel. Since the vessel is certificated to operate without a deckhand, these instructions should also include the direction of a designated passenger’s actions in the event of Master incapacitation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that Emergency instructions containing fire and man overboard instructions in the event of Master incapacitation are in the boat as instructed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 August 2020
Resolved
Prior to the carriage of passengers, to the satisfaction of the USCG, fit the vessel with ground tackle and mooring lines necessary for the vessel to be safely anchored and moored.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that Vessel has been fit with ground tackle and mooring lines necessary for the vessel to be safely anchored and moored as instructed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 August 2020
Resolved
Within 30 days, to the satisfaction of the USCG, mark each life jacket in clearly legible block capital letters with the vessel's name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that Life jackets have been marked in clearly legible block capital letters with the vessel’s name as instructed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2020
Resolved
Within 30 days, to the satisfaction of the USCG, mark each ring life buoy must be in clearly legible block capital letters with the vessel's name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that Each ring life buoy has been marked clearly in legible block capital letters with the vessel’s name as instructed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 August 2020
Resolved
Prior to the carriage of passengers, to the satisfaction of the USCG, place into service either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions, which are stowed in a suitable, watertight container that is marked “First-Aid Kit” and is easily visible and readily available to the crew.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that A first-aid kit has been placed into service with equivalent contents and instructions, which are stowed in a watertight container that is marked “First-Aid Kit” and is easily visible.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 August 2020
Resolved
Prior to the carriage of passengers, to the satisfaction of the USCG, prove all portable fire extinguishers underwent annual maintenance, under the supervision of a certified person, IAW NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that All portable fire extinguishers have undergone annual maintenance, under the supervision of a certified person.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 August 2020
Resolved
Prior to the carriage of passengers, to the satisfaction of the USCG, prove the Clean Agent Fire Extinguishing System underwent annual inspection, servicing and testing IAW NFPA 2001 by a qualified Fire Protection Service Technician.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that The Clean Agent Fire Extinguishing System has undergone annual inspection, servicing and testing IAW NFPA 2001 by a qualified Fire Protection Service Technician.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 August 2020
Resolved
Prior to the carriage of passengers, to the satisfaction of the USCG place into service at least three (03) 9.5 liter (2.5 gallon) buckets, with an attached lanyard which can reach below the waterline from the gunwale, so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that Three 2.5 gallon buckets, with an attached lanyard which can reach below waterline from the gunwale, so as to be easily available during an emergency. The words “FIRE BUCKET” are stenciled on.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 August 2020
Resolved
Owner has submitted the paperwork to NVDIC to change the name. Waiting on NVDIC to process the request. Timeline changed to within one year, to the satisfaction of the USCG, mark on some clearly visible exterior part of the port and starboard bow and the stern of the vessel the name of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 September 2020
Resolved 19 May 2021
Resolution: Vessel wrapped the name. Witnessed by Marine Inspector during annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 August 2020
Resolved
Within 30 days, to the satisfaction of the USCG mark the hailing port of the vessel on some clearly visible exterior part of the stern of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 September 2020
Resolved 19 May 2021
Resolution: Vessel name marked on the stern of the vessel. Witnessed during annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 August 2020
Resolved
Prior to the carriage of passengers, to the satisfaction of the USCG, place into service at least two operable portable battery lights; one of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 24 September 2020
Resolution: Received Master's statement and photographic evidence that at least two operable portable battery lights were placed into service.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 June 2018
Resolved
Provide Safety Radio Telephony Certificate. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 30 July 2019
Communications › Alarms/Indicators › Fire Alarm
Issued 20 June 2016
Resolved
Properly repair gasoline vapor detection system. Found vapor detection system inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2016
Resolved 28 June 2016
Resolution: Owners maintenance team found a blown fuse and loose wire connection at the alarm unit at the operating station. Replaced fuse and reconnected wire connection and system tested - SAT.
Fire Fighting › Fire Bucket › Lanyard
Issued 20 June 2016
Resolved
Replace missing lanyard on two of the three fire buckets.
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 28 June 2016
Resolution: Crew attached lanyards to the two fire buckets.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 June 2016
Resolved
Post copy of COI and Stability ltr visible to passengers and crew.
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 28 June 2016
Resolution: Owners rep posted copies of the COI and Stability ltr in the passenger cabin.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 20 June 2016
Resolved
FCC Safety Radiotelephony Certificate missing, not onboard.
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 28 June 2016
Resolution: Owner found FCC Safety Certificate in the office and placed a copy onboard the vsl.
Communications › Radio Communications › EPIRB
Issued 2 June 2008
Resolved
Replace expired hydrostatic release on EPIRB.
Due 16 June 2008
Resolved 16 June 2008
Engineering › Gasoline Engine (propulsion) › Connecting Rod (4 cycle)
Issued 5 September 2007
Resolved
Make permanent repairs to effected engine prior to carriage of pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 23 July 2007
Resolved
Provide valid Marine Radio Operator Permit for Vessel Captain.
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Resolution: Provided valid Marine Radio Operator Permit for Vessel Captain.
Engineering › Gasoline Engine (propulsion) › Distributor (4 cycle)
Issued 12 July 2007
Resolved
Repair the port main engine to the satisfaction of an attending marine inspector prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2007
Resolved 16 July 2007
Resolution: Underway test completed, sat. The Port Fuel Oil Pump failed & replaced.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 April 2007
Resolved
Provide current drug testing consortium participation letter listing crewmembers.
Due 1 May 2007
Resolved 1 May 2007
Resolution: Drug/Alcohol consortium letter provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 24 April 2007
Resolved
Provide maintenance manual for Fireboy pre-engineered system onboard.
Due 1 May 2007
Resolved 1 May 2007
Resolution: Maintenance manual provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 April 2007
Resolved
Service system and provide current servicing report for fixed fire system.
Due 1 May 2007
Resolved 1 May 2007
Resolution: Verified servicing report. Serviced 1 May 2007.
Construction/Loadline › Hull › Double Hull
Issued 13 March 2007
Resolved
Inspectors ID'd 4" crack in forward keel doubler. Operator to provide repair proposal, make repairs.
Due 14 April 2007
Resolved 31 March 2007
Resolution: Crack gouged and welded.
Construction/Loadline › Hull › Weld
Issued 13 March 2007
Resolved
Operator to make repairs to the following welds: two cracked welds on stringers under the deckplates on the port side of the deck forward of the operator's station; cracks on the outboard sides of both mounts for the stern ladder; cracked welds holding the port-side overhead shelf.
Due 14 April 2007
Resolved 31 March 2007
Resolution: Welds on shelf and ladder gouged and welded. One cracked weld in forward compartment was reinforced by additional welds on each side. One cracked weld was left alone due to inaccessibility.
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 April 2006
Resolved
Obtain US Coast Pilot to maintain on board vessel.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 9 May 2006
Resolution: US Coast Pilot was purchased and is stowed on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 April 2006
Resolved
Obtain Coast Guard Light List to maintain on board vessel.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 9 May 2006
Resolution: Coast Guard Light List was purchased and is stowed on board.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 April 2006
Resolved
Obtain Tidal Current Tables to maintain on board vessel.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 9 May 2006
Resolution: Tidal Current Tables were purchased and are stowed on board.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 April 2006
Resolved
Install rail courses on forward bow railings.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2006
Resolved 9 May 2006
Resolution: Rail courses were installed as required.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 April 2006
Resolved
Attach buoyant lifeline to Lifebuoy.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 9 May 2006
Resolution: Buoyant lifeline was attached to the lifebuoy.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 28 April 2006
Resolved
Obtain manual for, and test vapor detector.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 9 May 2006
Resolution: Manual was obtained and proper test procedures were demonstrated.
Lifesaving › Hand Flares › Not on Board
Issued 16 March 2006
Resolved
Provide Three hand red flares and three hand orange smoke flares IAW 46 CFR180.68. Flares to be in a portable water thight container as discribed in 46 CFR 185.614.
Due 16 April 2006
Resolved 28 April 2006
Resolution: Flares were obtained and are stowed as required.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2006
Resolved
Provide the follwing FCC Requirements; Station license, Safety Certificate, and operators permit. (47 CFR 13 and 80)
Due 16 April 2006
Resolved 28 April 2006
Resolution: Permits aquired and maintained on board.
Engineering › Fuel Oil Service System
Issued 3 May 2003
Resolved
Install fire sleeves over current REDLINE fuel hoses from fuel pump to fuel injection body. 46 CFR 182.720 LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Due 3 June 2003
Resolved 15 May 2003
Documentation
Issued 30 April 2001
Resolved
Receive "NEW TO ZONE INSPECTION" prior to the carriage of passengers in [name withheld] zone.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Documentation
Issued 30 April 2001
Resolved
Provide proof of chemical testing program prior to the carriage of passengers. 46 CFR 16
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 30 April 2001
Resolved
Provide approved first aid kit prior to the carriage of passengers. 46 CFR 184.710
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Documentation
Issued 30 April 2001
Resolved
Provide vessel documentation to MSO Anchorage, AK prior to operating in Alaska zone. 46 CFR 67.7/67.9
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001