MAURY USCG vessel records Sign in
← All vessels

PETER R WEISS

PETER R WEISS is a 2001 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 2001, most recently in May 2026, along with 57 deficiencies, 2 operational controls and 3 casualty investigations between 2002 and 2016.

Records from 2001 to 2026. Most recent: inspection, 4 May 2026.

Built
2001
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF8566
Flag
UNITED STATES
367496240
Maury page id
psix-23532

Inspections, by type

…with no type recorded13
Years with a record 23 calendar years (2001–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)78.5 ft × 28.4 ft × 8.2 ft
Registered tonnagegross 82 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE · SITKA, AK, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationTwin Hull
Hailing portWEEHAWKEN, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF8566MMSI 367496240 · active · compulsorily equipped · granted 2 June 2021, expires 22 June 2031
WDA4630MMSI 366811510 · expired · compulsorily equipped · granted 15 May 2001, cancelled 16 July 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PHILLIS WHEATLEY Passenger (Inspected) · MISLE 39725 · 20 March 2003 · activity 1762272

Inspection history · 54

4 May 2026 Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8367577
30 April 2026 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8355427
3 March 2025 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8084144
16 September 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8001928
22 May 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7917306
5 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7663045
14 September 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7559031
16 February 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7397472
26 May 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7207554
6 May 2021 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7190372
5 March 2020 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6918944
6 December 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6879148
4 November 2019 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849382
16 September 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6812878
1 October 2018 Damage Survey · Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6567205
26 September 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6549366
10 January 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6335463
21 August 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6247574
18 July 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6222033
4 April 2017 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6118065
7 February 2017 Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6088092
30 November 2016 In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6049759
23 July 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952226
23 July 2016 Damage Survey · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952910
6 June 2016 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5898694
16 June 2014 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4889943
18 May 2012 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4314624
25 March 2010 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3702457
4 February 2009 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3412411
3 September 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3316869
22 July 2008 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3275973
25 February 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3153204
7 November 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3095724
5 July 2007 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2993558
6 February 2007 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2867640
6 February 2007 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2867969
25 October 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2807937
26 September 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2787144
7 August 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2739191
25 July 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2724495
12 April 2006 MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2622912
18 January 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2585870
27 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2523553
10 March 2005 Annual Inspection · Hull Examination · MARPOL Annex V Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2307159
16 March 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2025229
21 March 2003 Deficiency Check · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1760897
20 March 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1762272
19 March 2003 MARPOL Annex V Examination · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1759585
26 June 2002 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1637285
20 February 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1488367
4 February 2002 Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600207
5 June 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 99641
11 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1453891
30 March 2001 Hull Examination · MARPOL Annex V Examination · Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1467753

Deficiency record · 57

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2026 Resolved
"The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable." MI observed gasket peeling from stbd E/R hatch for ventilation closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2026
Resolved 7 May 2026
Resolution: Observed proper repair and installation of gasket.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 April 2026 Resolved
"Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray." MI observed battery bank fastener with incorrect hardware in stbd E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2026
Resolved 7 May 2026
Resolution: Observed battery bank properly secured with proper equipment.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 April 2026 Resolved
"Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock" MI observed electrical cracked 110V switch box in stbd E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2026
Resolved 7 May 2026
Resolution: Observed new installed swith box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2026 Resolved
"...The piping must be properly supported by noncombustible hangers or blocks." MI observed broken bracket for the wet exhaust in the port E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2026
Resolved 7 May 2026
Resolution: Observed repaired bracket and exhaust properly secured.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2026 Resolved
MI observed popped weld in the port fuel space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2026
Resolved 7 May 2026
Resolution: Observed proper v and weld completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 April 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. A cracked weld was noted in the STBD fore peak at the joint between deck plating and a transverse frame. Submit repair plan and complete repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Cracked weld was grinded out and re-welded.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 April 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. A cracked weld was noted on the forward transverse bulkhead in the STBD generator room. Submit repair plan and complete repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Cracked weld wad re-welded and tested with dye penetrant. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023 Resolved
All observed hazardous situations must be corrected. Two bottom steps from the upper deck to main deck were unstable and require weld repairs to ensure passenger safety. One step has a crack in the middle and one has a joint that is not fully welded. Submit repair plan and complete repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: New steps were installed. All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 5 March 2020 Resolved
Vessel must provide drug and alcohol program enrollment certificates for crew.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2020
Resolved 9 March 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2020 Resolved
The name of the vessel must marked on some clearly visible exterior part of the port and starboard and stern of the vessel. The hailing port of the vessel must be clearly visible on the stern. Vessel is not marked with name on port and starboard bow or hailing port on the stern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2020
Resolved 9 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 5 March 2020 Resolved
Piping for vital systems must be metallic. Bilge piping check valves are currently PVC.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 9 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 5 March 2020 Resolved
Starboard side generator has oil leak and excess oil and lube underneath.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 16 March 2020
Resolution: No oil noticed under the STBD generator, Inspector test ran generator and found all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 5 March 2020 Resolved
Remove or relocate excess oil storage out of machinery spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2020
Resolved 16 March 2020
Resolution: Excess oil was removed out of all machinery spaces.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 November 2019 Resolved
VESSELS OF AT LEAST 5 NET TONS, ENGAGING IN COASTWISE TRADE SHALL HAVE A CERTIFICATE OF DOCUMENTATION (C.O.D.). THE VESSELS C.O.D. WAS EXPIRED AND A NEW ONE HAD NOT BEEN APPLIED FOR. 46CFR67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 16 December 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 September 2019 Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. The vessel missed its dry dock and internal structural examination date. DD/ISE must be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2019
Resolved 4 November 2019
Resolution: Vessel is currently in process of completing DD/ISE per MISLE Case # 6849382.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 October 2018 Resolved
Excessive corrosion identified under the sewage tank. Repair pitted wet deck, transition plates and inboard side shells in laz.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2018
Resolution: Repair work complete.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 30 November 2016 Resolved
Prove proper operation of #3 jet drive controls.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2016
Resolved 7 December 2016
Resolution: Attened vessel.
Engineering › Reduction Gearing/Clutches › Hose
Issued 30 November 2016 Resolved
Replace hydraulic hose on #2 jet drive on ram for bucket control.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2016
Resolved 7 December 2016
Resolution: Attened vessel.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 30 November 2016 Resolved
Fabricate and install fire damper for heater room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 30 December 2016
Resolution: Complete
Construction/Loadline › Hull › Hull Plating
Issued 23 July 2016 Resolved
Crop and renew 6'x2' inset in the port bow.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2016
Construction/Loadline › Structures › Deck Plating
Issued 23 July 2016 Resolved
Crop and renew 7'x4' upset area of port bow deck in way of the man overboard ladder.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2016
Communications › Radio Communications › EPIRB
Issued 23 July 2016 Resolved
Re-mount EPIRB in float free position and replace expired registration decal.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 July 2016 Resolved
Verify Validity or renew Comunications act Safety Radio and Bridge to Bridge Telephony Certificates.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 28 July 2016
Construction/Loadline › Hull › Transverse Frame
Issued 23 July 2016 Resolved
Vee and weld all cracked welds in the port forward void including 3 welds in Bay 1, 1 weld in Bay 2, and 2 welds in Bay 3.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 28 July 2016
Stability › Watertight Integrity › General
Issued 6 June 2016 Resolved
Affect temporary repairs for STBD quarter deck plate cracks. Make hull water tight.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016
Resolution: Corrected by welders on the spot.
Stability › Watertight Integrity › General
Issued 6 June 2016 Resolved
Crop and renew STBD quarter deck plate.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Inspector attended the vessel and verified that the STBD quarter deck plate had been properly cropped and renewed.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 6 June 2016 Resolved
Replace damaged exhaust lagging on all propulsion engines.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Inspector attended the vessel and verified the exhaust lagging on the propulsion engines had been properly replaced.
Documentation › Logs/Records › Logbook (official)
Issued 6 June 2016 Resolved
Ensure proper logging of all monthly EPIRB tests.
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 15 June 2016
Resolution: Inspector attended vessel and ensured logging of monthly EPIRB tests were documented.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 July 2008 Resolved
Provide proof of conducting and logging the following: Man overboard drills, Maintenance of lifesaving equipment and EPRIB testing. Prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 28 July 2008
Resolution: Man overboard, maintenance, lifesaving and EPRIB were tested and logged.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 22 July 2008 Resolved
Provide for emergency broadcast placard.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 8 August 2008
Resolution: Emergency broadcast placard was provided.
Construction/Loadline › Hull › Hull Plating
Issued 22 July 2008 Resolved
V/W cracked welds IWO void #2 stbd side Bay#2 under deck (02 cracked welds)
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 8 August 2008
Resolution: Welds were repaired.
Construction/Loadline › Hull › Hull Plating
Issued 22 July 2008 Resolved
Replace cracked windows main deck #'s 12 + 13 stbd and 8 thru 10 port.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 8 August 2008
Resolution: Windows were replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 July 2008 Resolved
Repair cracked rail supports port and stbd (metal loops that hold wire rail courses) aft. Also replace all metal clips as necessary
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 September 2008
Resolved 8 August 2008
Resolution: Rail crack and metal clips were repaired.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 July 2007 Resolved
Repair cracks in starboard generator wet exhaust muffler.
Action required: 705 - Other - as specified
Due 5 August 2007
Resolved 12 September 2007
Documentation › Certificates/Documents › FCC SSL
Issued 5 July 2007 Resolved
Provide current FCC Safety Radio Certificate. Vessel operation restricted to no more than 1000 feet from shore until this requirement is met.
Action required: 705 - Other - as specified
Due 5 August 2007
Resolved 9 July 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 5 July 2007 Resolved
Secure stern light fixture to mounting bracket.
Action required: 705 - Other - as specified
Due 5 August 2007
Resolved 12 September 2007
Communications › Radio Communications › EPIRB
Issued 5 July 2007 Resolved
Provide EPIRB for vessel, prior to operating in cold water period.
Action required: 705 - Other - as specified
Due 5 August 2007
Resolved 12 September 2007
Engineering › Fuel Oil Service System › Hose
Issued 5 July 2007 Resolved
Replace worn fuel return line, port side forward main engine (in way of forward engine room vent along outer hull).
Action required: 705 - Other - as specified
Due 5 August 2007
Resolved 12 September 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 6 February 2007 Resolved
V/weld cracked welds in forepeak, 2nd bay from hatch, 6th longitudinal from bulkhead, IVO overhead forward, 3rd long and 7th long on overhead rear space.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 February 2007
Resolution: Welds repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 6 February 2007 Resolved
V/weld cracked weld in forepeak, 1st bay, IVO hatch, 3rd long from bulkhead on overhead, 2nd transverse frame aft.
Action required: 705 - Other - as specified
Resolved 23 February 2007
Resolution: Weld repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 6 February 2007 Resolved
V/weld cracked weld in 2nd void, 3rd bay from hatch, starboard side IVO corner of overhead and aft transverse frame.
Action required: 705 - Other - as specified
Resolved 23 February 2007
Resolution: Weld repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 6 February 2007 Resolved
V/weld fractured weld in way of transverse wev frame, port side, lazerette.
Action required: 705 - Other - as specified
Resolved 23 February 2007
Resolution: Weld repaired.
Engineering › Bilge Water Management System › Strainer
Issued 6 February 2007 Resolved
Replace strainer in way of electric submersible bilge pump, port side steering space.
Action required: 705 - Other - as specified
Resolved 23 February 2007
Resolution: Strainer replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 6 February 2007 Resolved
Replace crank case exhaust hose in way of port, inboard, main engine.
Action required: 705 - Other - as specified
Resolved 23 February 2007
Resolution: Exhaust hose replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 June 2006 Resolved
Conduct MOB and fire drills to the sat of the attending CG MI.
Action required: 705 - Other - as specified
Due 27 June 2006
Resolved 28 November 2006
Resolution: Conducted satisfactory MOB and fire drill.
Construction/Loadline › Hull › Weld
Issued 12 April 2006 Resolved
Reweld Bracket for Handrail on port side.
Condition: Damaged By Earlier Event
Due 12 April 2006
Resolved 12 April 2006
Resolution: Bracket rewelded.
Construction/Loadline › Hull › Weld
Issued 12 April 2006 Resolved
Reweld cracked weld on Deck behind front rubrail port side.
Condition: Damaged By Earlier Event
Due 12 April 2006
Resolved 12 April 2006
Resolution: Repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 12 April 2006 Resolved
Prove proper operation of #2 port engine to the satisfaction of the attending CG MI--PRIOR TO CARRYING PASSENGERS
Condition: Damaged By Earlier Event
Due 12 April 2006
Resolved 12 April 2006
Resolution: Repaired and sat sea trialed.
Construction/Loadline › Hull
Issued 21 March 2003 Resolved
Operator reported that vessel M/V MOIRA SMITH (1121370) while approaching pier to morage allided with subject vessel, causing 20" by 4" hole in hull, port side in jet room.. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 24 March 2003
Resolution: Sideshell was properly cropped and renewed using Industry standards to satisfaction of attending marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 21 March 2003 Resolved
Crop and renew sideshell frames #1 and #2.
Condition: Damaged By Earlier Event
Due 24 March 2003
Resolved 24 March 2003
Resolution: Sideshell frames renewed.
Construction/Loadline › Hull
Issued 19 March 2003 Resolved
C/R "I" beam @ bow loader IWO rubber bumper starboard of centerline.
Due 2 April 2003
Resolved 28 March 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 2 April 2002 Resolved
Prove proper operation of port generator. LEGACY COMPONENT DESC: Battery Charging Circuitry
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 20 May 2002
Resolution: Checked by [name withheld].
Engineering › Bilge Water Management System
Issued 2 April 2002 Resolved
Properly mount stbd engine room rule pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 12 April 2002
Resolution: Rule pump permanently mounted ([name withheld]).
Deck/Cargo › Mooring/Anchoring
Issued 2 April 2002 Resolved
Properly repair stbd aft cleat. LEGACY COMPONENT DESC: Cleat
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 12 April 2002
Resolution: Both stbd aft cleats were repaired ([name withheld]).
Lifesaving
Issued 30 March 2001 Resolved
Place NOAA registration sticker on the EPIRB.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Unknown
Issued 30 March 2001 Resolved
Vessel shall not be placed into passenger carrying service until a new to zone inspection is completed by a U.S. Coast Guard Activities New York Marine Inspector.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Documentation
Issued 30 March 2001 Resolved
Provide Certificate of Documentation.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001

Casualty record · 3

20 February 2002Routine · role: Involved in a Marine Casualty · activity 1488367
7 November 2007Routine · role: Involved in a Marine Casualty · activity 3095724
23 July 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 14 injured · activity 5952226
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GIOVANNI DA VERRAZANO (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.