Records from 2001 to 2025. Most recent: inspection, 10 June 2025.
Inspection history · 49
10 June 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8150067
16 December 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8045072
3 June 2024
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7898160
16 May 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7672868
12 December 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7587658
14 March 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7407183
4 August 2021
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7277611
4 August 2021
Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7278011
17 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7227806
18 December 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7113603
4 June 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6968680
10 December 2018
Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6594899
4 December 2018
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6588100
23 March 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6377540
5 March 2018
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6365782
21 March 2017
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6108600
14 February 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6088190
21 December 2016
In-Service Inspection · Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6078716
27 September 2016
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6011253
27 September 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6011271
23 March 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838708
23 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838709
26 March 2014
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4823159
26 January 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3933862
26 January 2011
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3960403
13 January 2011
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3928558
15 December 2010
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3911250
10 March 2010
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3712716
3 February 2010
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3674165
13 March 2009
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3435603
10 March 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3432772
6 November 2008
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 3359020
18 December 2007
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3122934
25 October 2007
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3086902
1 May 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2637938
3 April 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2616654
6 December 2005
MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2546649
13 October 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2513409
10 October 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2511325
8 November 2004
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2236756
9 December 2003
Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1961189
20 October 2003
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1931977
20 March 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1762272
23 January 2003
Damage Survey · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1734247
21 January 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1732791
8 January 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1730676
5 April 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1602783
29 January 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1482434
9 December 2001
MARPOL Annex V Examination · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1076953
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 May 2023
Resolved
Fuel level gauges on diesel fuel tanks must be of tubular glass and heat resistant material. The gauge line was made of rubber tubing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 June 2024
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 May 2023
Resolved
The fuel tank connections must be fitted with automatically closing devices in the event the gauges or gauge lines rupture. The fuel level gauge did not have self closing devices.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 August 2021
Resolved
Propulsion machinery must be capable of operating
at constant marine load under such requirements
without exceeding its designed limitations. Vessel
lost propulsion while underway.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2021
Resolved 5 August 2021
Resolution: Replaced fuse.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 December 2018
Resolved
Fire main line in the engine room was found to be wasted through.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2019
Resolved 9 January 2019
Resolution: Removed fire main line and replaced with a new pipe.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 December 2018
Resolved
Unapproved solid core wiring was used in instillation of the air-conditioning units. Remove and replace A/C wire with approved wire.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2019
Resolved 9 January 2019
Resolution: Solid core cable was removed and approved wire was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 4 December 2018
Resolved
The engine room deck hatch was found damaged. Repair/replace engine room deck hatch.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2019
Resolved 9 January 2019
Resolution: Engine room deck hatch was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Crop and renew hull strainer on starboard generator seawater intake.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 9 January 2019
Resolution: Hull strainer was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2018
Resolved
Replace forepeak bilge pickup.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 9 January 2019
Resolution: Forepeak bilge pickup was replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 December 2018
Resolved
Crop and renew hull plate 18 inches out from the keel port and starboard in void space #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 9 January 2019
Resolution: Hull plate was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2018
Resolved
Repair/replace bilge pickup valve handle in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 9 January 2019
Resolution: Bilge pickup valve handle was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 December 2018
Resolved
Repair deck rails and stanchions on main deck. (Port, Starboard, and Aft-deck.)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 9 January 2019
Resolution: All deck rails and stanchions on the main deck were repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 4 December 2018
Resolved
Repair/replace cleat on port side.
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 9 January 2019
Resolution: Cleat was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Replace/Provide adequate insulation on main engine exhaust in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 9 January 2019
Resolution: Insulation for main engine and engine room was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Provide servicing reports for water jet system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 January 2019
Resolved 11 January 2019
Resolution: Received servicing reports for water jet system.
Personnel › Training › Familiarization Training
Issued 23 March 2018
Resolved
Provide training for the crew on proper use of newly installed davit system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2018
Resolution: Resolved, Port Captain provided documentation demonstrating the crew was trained.
Personnel › Training › Familiarization Training
Issued 23 March 2018
Resolved
Provide training for the crew on proper use of newly installed fire and bilge pump system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2018
Resolution: Resolved, Port Captain provided documentation demonstrating the crew was trained.
Lifesaving › Lifebuoys › Quantity
Issued 21 March 2017
Resolved
Provide (02) 24" ring life buoys.
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 28 March 2017
Resolution: Attended vessel and visually inspected new (02) 24" ring life buoys.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 27 September 2016
Resolved
Vessel suffered small fire on stbd engine IWO turbo charger. Conduct component inspection and provide causal analysis.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2016
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 September 2016
Resolved
Identify damaged components on stbd engine and replace in kind with with manufacture approved parts and installation procedures. Vessel must demonstrate a operational test with an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 5 October 2016
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 26 January 2011
Resolved
Vessel sustained severe damage to all 3 MDE's and assoc. engine room equip. on the morning of 26JAN11. The vessel must assess all the damage to the vsl due to the engines overheating and provide a report to the CG SECNY. The report & sub. repairs must be to the satisfaction of the attending CG [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2012
Resolution: Inspected engines at the dock then u/w test satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 26 January 2011
Resolved
Upon completion of all the repairs to the vesel the vessel must conduct sea-trials in the presence of a CG [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2012
Resolution: Completed u/w checks and operational movement of a MOB drill / full power run in AOR for approx 20 min.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 January 2011
Resolved
Vessel must service all fire-fighting equipment discharged on 26JAN11 to teh satisfaction of the attending CG [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2012
Resolution: All fire-fighting equipment has been service Mar 2012.
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2011
Resolved
Vessel must address deck buckling and damaged engine room frames. A repair proposal must be submitted to the CG SECNY for review and approval prior to starting repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2012
Resolution: Repairs were addresed and completed by sector Del Bay.
Electrical › Electric Supply System (service) › Cable
Issued 15 December 2010
Resolved
Re-shrink wrap power connectors on port and STBD main engines.
Action required: 705 - Other - as specified
Due 15 January 2011
Resolved 13 January 2011
Construction/Loadline › Hull › Hull Plating
Issued 10 March 2010
Resolved
Address damage to starboard forepeak in way of loading ramp. Grind out and weld all hull fractures. Repairs shall be to the satisfaction of the attending Coast Guard Marine Inspector prior to carrying passengers
Action required: 705 - Other - as specified
Resolved 11 March 2010
Resolution: Verified repair of damaged hull.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 3 February 2010
Resolved
Provide chafe protection for raw water intake line in way of portside main diesel engine.
Due 3 March 2010
Resolved 10 March 2010
Resolution: Verified proper elimination of chafe to raw water intake line in way of portside main diesel engine.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2009
Resolved
Replace port/aft cleat above aft platform.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2009
Resolution: Verified replacement of port/aft cleat.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2009
Resolved
Repair/attach all support structures for aft platform.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2009
Resolution: Verified repairs had been made to all support strucutres for aft platform.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 March 2009
Resolved
Attach safety rail on port side above aft platform.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2009
Resolution: Saftey rail attached on port side above aft platform.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2009
Resolved
Attach section of port/aft upper overhang.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2009
Resolution: Verifed repairs to section of port/aft upper overhang.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2009
Resolved
Repair fwd sponson area including twisted framing on STBD fwd corner and cracks in welds on frames below corners.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2009
Resolution: Verified repairs to forward sponson.
Fire Fighting › Fire Pumps › Arrangement
Issued 18 December 2007
Resolved
Replace wasted flex hose IWO fire pump.
Action required: 705 - Other - as specified
Due 18 January 2008
Resolved 16 January 2008
Resolution: Flex hose replaced in-kind.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 9 December 2003
Resolved
Prove proper time for time delay. LEGACY COMPONENT DESC: Operating Controls
Due 16 December 2003
Resolved 16 December 2003
Construction/Loadline › Hull
Issued 9 December 2003
Resolved
V/W aft bulkhead IWO #2 SSL and stbd SS in lazarette. LEGACY COMPONENT DESC: Side Shell
Due 16 December 2003
Resolved 6 January 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 9 December 2003
Resolved
Permanently repair hinges to stbd gate. LEGACY COMPONENT DESC: Deck Rail
Due 16 December 2003
Resolved 16 December 2003
Construction/Loadline › Structures
Issued 9 December 2003
Resolved
Make permanent repairs to dive platform including deck/round stock (port corner).
Due 16 December 2003
Resolved 6 January 2004
Construction/Loadline › Hull
Issued 8 January 2003
Resolved
Vessel severely damaged from collsion. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2003
Stability
Issued 9 December 2001
Resolved
Vessel shall not be placed into passenger carrying service until an approved stability letter is issued by the U.S. Coast Guard Marine Safety Center and posted onboard the vessel. LEGACY COMPONENT DESC: Stability Letter
Due 30 January 2002
Resolved 15 January 2002
Resolution: RECIEVED COPY OF STABILITY LETTER BASED ON SISTER SHIP DETERMINATION
Operations/Management › Drills/Instruction
Issued 9 December 2001
Resolved
Vessel shall not be placed into passenger carrying service until Fire, Person Overboard, and Abandon Ship drills are conducted.
Due 30 January 2002
Resolved 15 January 2002
Resolution: CONDUCTED DRILLS SATISFACTORILY
Operations/Management › Passenger Operations
Issued 9 December 2001
Resolved
Vessel shall not be placed into passenger carrying service until a new to zone inspection is completed by a U.S. Coast Guard Activities New York Marine Inspector.
Due 30 January 2002
Resolved 15 January 2002
Resolution: CONDUCTED NEW TO ZONE INSPECTION