Records from 2004 to 2020. Most recent: operational control imposed, 17 September 2020.
Documentation record
Registered dimensions (L × B × D)87.3 ft × 24.0 ft × 8.7 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
17 September 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7060289
27 January 2020
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896655
21 November 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6860933
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
6 August 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6773886
10 June 2019
Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6706677
10 December 2018
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6594625
15 June 2018
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6444887
14 November 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6306796
16 June 2017
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6177446
19 December 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6059819
15 June 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5908355
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2020
Resolved
A DUAL VOLTAGE GENERATOR SHALL HAVE GROUND DETECTION PROVIDED. GROUND DETECTION PANEL INOP. 46CFR120.324
Action required: 705 - Other - as specified
Due 3 February 2020
Resolved 29 January 2020
Resolution: tech report.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 27 January 2020
Resolved
SANITARY INSPECTION. FAILED SANITARY INSPECTION IN AFT HEAD. 46CFR115.818
Action required: 705 - Other - as specified
Due 3 February 2020
Resolved 31 January 2020
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 27 January 2020
Resolved
ON A VESSEL GREATER THAN 65 FEET THE PA SYSTEM MUST BE A FIXED INSTALLATION AND BE AUDBILE THROUGHOUT THE ACCOMODATION SPACES. UPPER DECK PA SYSTEM INOP. 46CFR121.610
Action required: 705 - Other - as specified
Due 3 February 2020
Resolved 31 January 2020
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 January 2020
Resolved
VESSEL MUST HAVE AN AIS. AIS INOP. 46CFR164.46
Action required: 705 - Other - as specified
Due 3 February 2020
Resolved 30 January 2020
Resolution: received images satisfactory to MI to clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2019
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in a machinery space bilge subject to flooding from sea water piping within the space. Engine room and lazarette high level sensors are broken. Not in compliance with COI.
46CFR119.530
46CFR 115.100
Action required: 30 - Ship detained
Resolved 27 November 2019
Resolution: Observed satisfactory test of high level bilge alarms in engine room and lazarette.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 November 2019
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46CFR160.050. MI determined ring buoy grab lines are deteriorated.
46CFR117.70(b)
Action required: 30 - Ship detained
Resolved 27 November 2019
Resolution: Waterfloat light operates properly installed with quick release clip, and new grab lines installed on ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 November 2019
Resolved
A fixed gas fire extinguishing system must be approved by the Commandant and installed to the satisfaction of the cognizant [name withheld] discovered the pressure switches were attached with temporary zip-ties. Not in compliance with COI.
46CFR181.20-5(a)
46CFR 115.100
Action required: 30 - Ship detained
Resolved 27 November 2019
Resolution: Pressure switch properly installed with permenant mounts and observed satisfactory test of the fixed fire extinguishing system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2019
Resolved
Each life jacket carried onboard must meet the specifications in 46CFR160.002, 160.005 or 160.055 unless otherwise specified. MI found that several of the provided life jackets were not in serviceable condition and lacked the required retroreflective tape. Not in compliance with COI.
*7 days to rectify*
46CFR117.71(c)
46CFR 115.100
Action required: 705 - Other - as specified
Resolved 27 November 2019
Resolution: Replaced all non serviceable life jackets. Recounted all life jackets onboard to reflect the proper amount in accordance with COI.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 November 2019
Resolved
A vessel must carry a first aid approved under 46CFR160.041 or equivalent. MI discovered the provided first aid kit had expired medications and missing items.
*7 days to rectify*
Action required: 705 - Other - as specified
Resolved 27 November 2019
Resolution: Replaced expired first aid kit with a new first aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019
Resolved
An exposed hazard such as gears or rotating machinery must be protected by a cover or guard. MI found that multiple metal exhaust fans in the overhead of passenger accommodation areas were missing covers.
46 CFR 177.35-15(a)
Action required: 30 - Ship detained
Resolved 27 November 2019
Resolution: Installed covers for ventilation system in main accomodation space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019
Resolved
The vessel GEORGE WASHINGTON is a "TL boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.25.50
Action required: 30 - Ship detained
Resolved 27 November 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 August 2019
Resolved
The maximum passengers allowed on the upper decks must be indicated by a durable markings of numbers and letters at least one inch in height at the entranceway to each deck. Vessel is missing max passenger permitted in upper deck.
46 CFR 185.30-3(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 19 August 2019
Resolution: Proper number of passengers were labled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2019
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Vessel had adult and child life jackets in same location with no divider.
46 CFR 180.78(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 19 August 2019
Resolution: Divider was added
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 August 2019
Resolved
A hatch cover must be attached by hinges, captive chains, or other devices to prevent its lost. Void #1 hatch needs device attached to prevent its lost.
46 CFR 179.360(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 19 August 2019
Resolution: Securing device was added to hatch.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 15 June 2018
Resolved
A device must be provided to automatically shut down engines that draw intake air from a protected space prior to the release of extinguishing agent into the space. Engines are not able to be shut down remotely or via the Halon system. 46 CFR 181.410(b)(ii)(10)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Operator had switches repaired and fucntion checked in the presence of a marine inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 June 2018
Resolved
The shutoff valve at the fuel tank must be manually operable from outside the compartment in which the valve is located. The cable that actuated the valve was broken due to fraying. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 20 June 2018
Resolution: The frayed cable was replaced and function was verified.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 15 June 2018
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard that provides continuous indication of the circuit status to ground with with a provision to momentarily remove the indicating device from ground. The gauge for the ground detection was stuck at one amp and did not move when a ground was induced or the detection button pressed. 46 CFR 183.378
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 20 June 2018
Resolution: The ground detection system was serviced and broken components replaced. Function checked.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 June 2016
Resolved
Provide DSC and MMSI number on radios.
Condition: Improper/Lack of Maintenance
Due 15 July 2016
Resolved 15 June 2016
Resolution: MMSI number programed.