Records from 2007 to 2026. Most recent: inspection, 17 June 2026.
Inspection history · 25
17 June 2026
Internal Structural Exam · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8406488
12 May 2026
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8356818
30 April 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8358829
5 November 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264834
25 June 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8166890
18 May 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7915501
25 April 2024
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897735
16 June 2023
Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7716695
17 November 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7596087
28 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7375972
28 July 2021
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7270359
25 November 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7101973
5 May 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6953087
4 March 2020
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6920730
3 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6921216
27 January 2020
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896638
15 January 2020
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6893305
23 November 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861316
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
6 May 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6677723
7 May 2018
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6407831
4 December 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6317843
26 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6295590
8 May 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6141155
2 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5867001
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 June 2025
Resolved
Fire dampners for port side engine room, both forward and aft, unable to close in case of a fire. Repair dampner.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
Resolution: Rcvd video of both dampners properly working
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 April 2024
Resolved
..life jackets must be stored in convenient places distributed throughout accommodation spaces. Vessel is missing life jacket storage on main deck. Vessel must install proper storage for life jackets. Vessel is restricted to 150 passengers until proper storage is installed.
Action required: 705 - Other - as specified
Resolved 21 May 2024
Resolution: Vessel installed life jacket storage.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2024
Resolved
..rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Vessel does not have line/safety chains at forward section of top deck. Vessel must install safety line/chain on top deck. Vessel shall restrict passenger access to top deck.
Action required: 705 - Other - as specified
Due 3 May 2024
Resolved 2 May 2024
Resolution: Vessel installed safety chains in identified locations.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 28 July 2021
Resolved
THE DESIGN OF ALL EXHAUST SYSTEMS MUST ENSURE MINIMUM RISK OF INJURY TO PERSONNEL. PROTECTION MUST BE PROVIDED IN COMPLIANCE WITH 46 CFR 177.970 WHICH STATES "PIPING, INCLUDING VALVES, PIPE FITTINGS AND FLANGES, CONVEYING VAPOR, GAS, OR LIEQUID, THE TEMPERATURES OF WHICH EXCEEDS 150 F, MUST BE SUITABLY INSULATED WHERE NECESSARY TO PREVENT INJURIES." DISCOVERED THAT THE EXHAUST PIPING IN THE STBD ENGINE ROOM WAS INSUFFICIENT ALLOWING MULTIPLE EXPOSED SECTIONS OF EXHAUST PIPING.
46 CFR 182.430 (a)
46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 29 July 2021
Resolution: Operator sent corrected photographs with replaced lagging on all exhaust piping in stbd e/r. (see documents)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 January 2020
Resolved
Replaced a ring life bouy due to deteriorated grab lines.
Action required: 10 - Deficiency Rectified
Resolved 27 January 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 November 2019
Resolved
On a vessel of at least 26', a visual and audible alarm must be provided at the operating station to indicate high water level in normally unmanned spaces. Attending Marine Inspector (MI) discovered the port side fuel tank void bilge alarm was inoperable. Vessel is not operating in compliance with the COI.
46CFR182.530(a)(2)
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 24 November 2019
Resolution: Witnessed satisfactory operation of bilge alarm.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 November 2019
Resolved
Fire hazards are to be minimized as it is reasonable and practicable. Attending MI noted accumulation of oil-soaked rags in the bilges of both engine rooms and both fuel tank voids. Vessel is not operating in compliance with the COI.
46CFR177.405(a)
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 24 November 2019
Resolution: Observed clean engine room and generator spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 23 November 2019
Resolved
Attachment plugs for portable apparatus operating at 100 volts or more must have a grounding pole and a grounding conductor in the portable cord. Attending MI found two portable, electric heaters that had the grounding prong removed from the attachment plug.
46CFR183.370(b)
Action required: 30 - Ship detained
Resolved 24 November 2019
Resolution: Space heater was removed from vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 November 2019
Resolved
All equipment, including switches, fuses, etc., must be suitable for the voltage and current utilized. Attending MI discovered one receptacle on the bridge and one in the accommodation space that were significantly burned.
46CFR183.220(b)
Action required: 30 - Ship detained
Resolved 24 November 2019
Resolution: Burned outlets have been replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 November 2019
Resolved
Portable and semi-portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. Attending MI found two of the required portable extinguishers that were not in serviceable condition (one partially discharged and the other severely corroded). Vessel is not operating in compliance with the COI.
46CFR176.810(b)(1)
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 24 November 2019
Resolution: Fire extinguishers have been replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 November 2019
Resolved
A pre-engineered fixed gas extinguishing system must be installed in accordance with the manufacturer's instructions. Attending MI found the starboard side generator enclosure was not complete and would not allow for effective operation of the attached fixed system. Vessel is not operating in compliance with the COI.
46CFR181.420(a)(4)
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 24 November 2019
Resolution: Cover on generator has been replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 November 2019
Resolved
A hatch exposed to the weather must be watertight. Attending MI discovered that both forward void hatches (port and starboard) were inoperable and could not be closed. Vessel is not operating in compliance with the COI.
46CFR179.360(a)
Action required: 30 - Ship detained
Due 7 December 2019
Resolved 24 November 2019
Resolution: FWD hatches have been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 23 November 2019
Resolved
A vessel must carry a first-aid kit approved under series 46CFR160.041 or a kit with equivalent contents and instructions. Attending MI found the first-aid kit was not onboard the vessel.
46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 24 November 2019
Resolution: New first aid kit was placed onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 November 2019
Resolved
A crew space must be of adequate construction and with suitable equipment to provide for the safe operation of the vessel and protection of the crew. Attending MI found that the carbon monoxide alarms in both the port and starboard jet rooms were not mounted properly.
46CFR177.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 24 November 2019
Resolution: CO monitors have been properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 November 2019
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Attending MI found wire connections outside of an enclosure on the bridge.
46CFR183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 24 November 2019
Resolution: broken phone has been removed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 November 2019
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control or service space. Attending MI found several 5-gallon containers of hydraulic oil stowed above the engine room hatch in the engine room entrance/service space.
46CFR174.45(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 24 November 2019
Resolution: Excessive hydraulic oil has been removed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 November 2019
Resolved
Life jackets must be stored in convenient places and be readily accessible. Attending MI discovered miscellaneous gear stored in the accommodation space life jacket container, which impeded access to the life jackets. Vessel not operating in compliance with the COI.
46CFR180.78(a)(2)
46CFR176.100(b)
Action required: 30 - Ship detained
Due 7 December 2019
Resolved 24 November 2019
Resolution: PFD storage has been cleared of other debris.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
This vessel is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.25-50
Action required: 30 - Ship detained
Resolved 24 November 2019
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 7 May 2018
Resolved
Vessel needs to have IBAs serviced. Vessel is restricted to a Rivers route.
Action required: 705 - Other - as specified
Resolved 11 September 2018
Resolution: Provided proof of servicing.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 May 2018
Resolved
Line attached to life ring is damaged and needs to be replaced.
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 21 May 2018
Resolution: Verified new grab line.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 May 2018
Resolved
Lagging insulation needs to be installed on turbos.
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 25 June 2018
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 7 May 2018
Resolved
Vessel needs to provide secondary power alarm for fire detection panel.
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 24 May 2018
Resolution: Ensured secondary power source alarm sounds for the fire detection system at the operating station.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 May 2018
Resolved
All electrical connection located in lazarette space need to be in junction boxes
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 21 May 2018
Resolution: Verified junction box in laz space.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 7 May 2018
Resolved
remove 3 amp ground
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 24 May 2018
Resolution: Verified ground detection meter read 0amps.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 2 May 2016
Resolved
Vessel missing two (02) required IBAs, the vessels route is limited to Cold water rivers 50% capacity or LBS w/in 1 mile from shore or warm waters only.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: Vessel provided servicing report for IBAs.
Communications › Radio Communications › EPIRB
Issued 2 May 2016
Resolved
EPIRB shall be tested monthly and logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 2 May 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 May 2016
Resolved
Provide proper operation of port generator space Fireboy override/shutdown test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2016
Resolution: Vsl replaced faulty part and provided proper operation of override/shutdown.