Records from 2005 to 2024. Most recent: inspection, 27 August 2024.
Inspection history · 19
27 August 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7995512
12 April 2024
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7894091
19 July 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7746488
12 July 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7739179
7 June 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7706211
19 May 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7454385
20 September 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7316110
10 September 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7311869
10 May 2020
Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6948829
8 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6950402
5 February 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6903516
23 November 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861322
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
17 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6716337
19 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6455716
24 May 2018
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6421742
2 November 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6299659
9 June 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6170370
31 May 2016
Annual Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5885784
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 April 2024
Resolved
Generator Fuel hose coupler fitting found damaged leaking fuel on discharge return side nex to manual fuel prime pump.
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: Vessel replaced with brand new brass hose coupler.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 April 2024
Resolved
Cracks in port side transverse framing at the weld point of chine. drill stop. 46CFR 176.700(a)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 17 April 2024
Resolution: see attached final report.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 April 2024
Resolved
Cracks in bow framing and hull around square push bow. 46CFR176.700(a)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See attached final report.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 17 April 2024
Resolved
Insulation around discharge side of keel cooler jacket water fixed piping, temperatoure was observed at 190 degrees. 46 CFR 970
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See Attached Final Report.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 April 2024
Resolved
Diesel fuel tank port side mounts found loose. 46 CFR 182.440(b)(3)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See attached final report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 April 2024
Resolved
Port side stancions found with cracked welds at base. 46CFR 177.900(b)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See attached final report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2020
Resolved
705 - Vessel inspection deferred till (8/31/2020). Vessel authorized to operate until (8/31/2020).
Action required: 705 - Other - as specified
Resolved 16 September 2020
Resolution: Vessel given a operational control
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 November 2019
Resolved
Owner/operator shall notify OCMI in advance of conducting hull repairs. Attending Marine Inspector discovered a 1.5" crack in the side shell of the vessel (starboard side, aft portion of fuel tank void). Vessel is not operating in compliance with the COI.
46CFR176.665
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 27 November 2019
Resolution: Crop and replace was completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 November 2019
Resolved
Tank connections from the fuel tank gauge must be devices that will automatically close in the event of a rupture to the gauge or gauge line. Attending Marine Inspector found that the valves for the fuel tank gauge were not capable of automatically closing.
46 CFR 182.440(a)(7)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Valves were replaced with self closing valves
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 November 2019
Resolved
Fixed fire extinguishing systems must have a device that automatically shuts down ventilation in the protected space. Attending MI found the dampers blocked by debris and hanging insulation. Vessel is not operating in compliance with the COI.
46CFR181.410(b)(10)
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Insulation replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2019
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems it must meet SAE J-1492. Attending MI found the fuel return line was deteriorated and cracked at the manifold (starboard, forward engine room).
46CFR181.720(e)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Fuel Hose replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2019
Resolved
Fire hazards are to be minimized as far as reasonable and practicable. Attending MI identified an oily sheen/residue on all bulkheads, decks and overhead in the fuel tank space. Vessel is not operating in compliance with the COI.
46CFR177.405(a)
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Space clean
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 November 2019
Resolved
Fixed fire extinguishing systems must have a device that automatically shuts down ventilation in the protected space. Attending MI discovered the fire dampers did not function when tested. Vessel is not operating in compliance with the COI.
46CFR181.410(b)(10)
46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Witness proper operation of Fixed System and shutdowns.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 November 2019
Resolved
Each battery used in an item of lifesaving must be replaced when expired. Attending MI found the float light battery had expired in 2015.
46CFR185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 2 December 2019
Resolution: Battery replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 November 2019
Resolved
The engine head, clock and exhaust manifold must be water-jacketed and cooled by water from a pump when the engine is running. Attending MI found a coolant leak coming from the forward end of the center engine.
46CFR182.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 2 December 2019
Resolution: Leak fixed
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 23 November 2019
Resolved
Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and authorized route. Attending MI found the windows throughout the passenger accommodations and on the bridge were cracked.
46CFR177.1020
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 5 February 2020
Resolution: Conducted COI scope inspection of vessel which resulted in 00 defs issued while clearing all outstanding items.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
This vessel is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.25-50
Action required: 30 - Ship detained
Resolved 2 December 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2019
Resolved
Vessel must demonstrate functional high level alarm for starboard side bilge.
Cite: 46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 2 July 2019
Resolution: Observed satisfactory test of alarms.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 June 2019
Resolved
The owner, charterer, master, or managing operator must ensure the deckhand identified can perform in an emergency in accordance with 46CFR185.420 and demonstrate to the Coast Guard. 705 c: To be cleared by Monday 24JUN2019.
Cite: 46CFR185.420(a)
Action required: 705 - Other - as specified
Due 24 June 2019
Resolved 2 July 2019
Resolution: Observed satisfactory man overboard drill.
Construction/Loadline › Hull › Bottom Plating
Issued 24 May 2018
Resolved
Crop/renew 1/4" hull plating in #2 void, second bay stbd side. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 25 May 2018
Resolution: Verified fitup, back gouge, and final welds/NDT (dye penetrant) same day; all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2017
Resolved
Vessel radio certificate is expired. Vessel is restricted to 1,000 ft from shore until a new certificate is issued.
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 20 June 2017
Resolution: Attended vessel and viewed newly issued FCC radio certificate.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 31 May 2016
Resolved
Ground detection not provides for the a/c system. Ground detection must be provided for a dual voltage generator installation IAW 46 CFR 183.324(c). Provide plan for approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 8 August 2018
Resolution: Vessel had ground detection installed. system tested all sat.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 31 May 2016
Resolved
Fire pump is electrically driven, power sources that power vital systems listed in 182.710 must have two sources of electricity.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 8 August 2018
Resolution: Vessel provided 2 sources of power for the fire pump.
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 May 2016
Resolved
Toilet is seawater feded from the fire pump piping. The hose to the toilet is not J1942. Cap at tee or provide hose that meets J1942.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 9 June 2017
Resolution: Cleared during annual inspection. Toilet and piping removed from vessel.