MAURY USCG vessel records Sign in
← All vessels

FATHER MYCHAL JUDGE

FATHER MYCHAL JUDGE is a 2001 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 2001, most recently in August 2024, along with 44 deficiencies, 4 operational controls and 2 casualty investigations between 2005 and 2024.

Records from 2001 to 2024. Most recent: inspection, 27 August 2024.

Built
2001
Last inspected
27 August 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG3566
Flag
UNITED STATES
366834160
Maury page id
psix-39724

Inspections, by type

…with no type recorded13
Years with a record 19 calendar years (2001–2024)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 17.5 ft × 7.3 ft
Registered tonnagegross 55 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE INC · SITKA, AK, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portWEEHAWKEN, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Net Ton
55 - Simplified, Gross Ton
33 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG3566MMSI 366834160 · active · compulsorily equipped · granted 7 April 2022, expires 26 April 2032
WDA6602MMSI 366834160 · expired · compulsorily equipped · granted 29 December 2001, cancelled 3 March 2012 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 20

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FIORELLO LAGUARDIA Passenger (Inspected) · MISLE 36 · 18 November 2019 · activity 6896988YOGI BERRA Passenger (Inspected) · MISLE 38 · 18 November 2019 · activity 6896988COMMONWEALTH Passenger (Inspected) · MISLE 36922 · 18 November 2019 · activity 6896988PORT IMPERIAL MANHATTAN Passenger (Inspected) · MISLE 284655 · 18 November 2019 · activity 6896988GEORGE WASHINGTON Passenger (Inspected) · MISLE 330751 · 18 November 2019 · activity 6896988THOMAS JEFFERSON Passenger (Inspected) · MISLE 330756 · 18 November 2019 · activity 6896988ALEXANDER HAMILTON Passenger (Inspected) · MISLE 330758 · 18 November 2019 · activity 6896988HENRY HUDSON Passenger (Inspected) · MISLE 382715 · 18 November 2019 · activity 6896988EMPIRE STATE Passenger (Inspected) · MISLE 396679 · 18 November 2019 · activity 6896988JOHN STEVENS Passenger (Inspected) · MISLE 449770 · 18 November 2019 · activity 6896988U.S. SENATOR FRANK R LAUTENBERG Passenger (Inspected) · MISLE 561914 · 18 November 2019 · activity 6896988BROOKLYN Passenger (Inspected) · MISLE 561925 · 18 November 2019 · activity 6896988CRISPUS ATTUCKS Passenger (Inspected) · MISLE 566037 · 18 November 2019 · activity 6896988FRED V MORRONE Passenger (Inspected) · MISLE 566038 · 18 November 2019 · activity 6896988SUSAN B ANTHONY Passenger (Inspected) · MISLE 566298 · 18 November 2019 · activity 6896988CONGRESSMAN ROBERT A. ROE Passenger (Inspected) · MISLE 607128 · 18 November 2019 · activity 6896988GOVERNOR THOMAS H. KEAN Passenger (Inspected) · MISLE 608328 · 18 November 2019 · activity 6896988ADMIRAL RICHARD E BENNIS Passenger (Inspected) · MISLE 610847 · 18 November 2019 · activity 6896988YORK Passenger (Inspected) · MISLE 1081932 · 18 November 2019 · activity 6896988MOLLY PITCHER Passenger (Inspected) · MISLE 1278350 · 18 November 2019 · activity 6896988

Inspection history · 46

27 August 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7995512
12 April 2024 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7894091
19 July 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7746488
12 July 2023 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7739179
7 June 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7706211
19 May 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7454385
20 September 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7316110
10 September 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7311869
10 May 2020 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6948829
8 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6950402
5 February 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6903516
23 November 2019 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861322
18 November 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
17 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6716337
19 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6455716
24 May 2018 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6421742
2 November 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6299659
9 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6170370
31 May 2016 Annual Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5885784
26 June 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4900081
5 June 2014 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4880946
1 May 2012 Annual Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4299817
29 February 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3155705
3 January 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2849788
16 October 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2801743
16 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2650522
16 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2651036
15 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2650180
7 April 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2619735
4 April 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2616895
21 March 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2607013
5 January 2006 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2568588
8 December 2005 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2555293
8 December 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2559839
29 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2830934
22 August 2005 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2471487
1 December 2004 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2251392
27 October 2004 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2229573
2 September 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2184687
30 August 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2181787
3 December 2003 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1958076
30 October 2003 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1938793
14 October 2003 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1927702
16 January 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1731239
15 January 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1482447
7 December 2001 Hull Examination · Plan Review "T" Boat · Initial Certification · MARPOL Annex V Examination · Initial Construction-Excluding Oversight
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1076952

Deficiency record · 44

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 April 2024 Resolved
Generator Fuel hose coupler fitting found damaged leaking fuel on discharge return side nex to manual fuel prime pump.
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: Vessel replaced with brand new brass hose coupler.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 April 2024 Resolved
Cracks in port side transverse framing at the weld point of chine. drill stop. 46CFR 176.700(a)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 17 April 2024
Resolution: see attached final report.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 April 2024 Resolved
Cracks in bow framing and hull around square push bow. 46CFR176.700(a)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See attached final report.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 17 April 2024 Resolved
Insulation around discharge side of keel cooler jacket water fixed piping, temperatoure was observed at 190 degrees. 46 CFR 970
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See Attached Final Report.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 April 2024 Resolved
Diesel fuel tank port side mounts found loose. 46 CFR 182.440(b)(3)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See attached final report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 April 2024 Resolved
Port side stancions found with cracked welds at base. 46CFR 177.900(b)
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 23 April 2024
Resolution: See attached final report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2020 Resolved
705 - Vessel inspection deferred till (8/31/2020). Vessel authorized to operate until (8/31/2020).
Action required: 705 - Other - as specified
Resolved 16 September 2020
Resolution: Vessel given a operational control
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 November 2019 Resolved
Owner/operator shall notify OCMI in advance of conducting hull repairs. Attending Marine Inspector discovered a 1.5" crack in the side shell of the vessel (starboard side, aft portion of fuel tank void). Vessel is not operating in compliance with the COI. 46CFR176.665 46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 27 November 2019
Resolution: Crop and replace was completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 November 2019 Resolved
Tank connections from the fuel tank gauge must be devices that will automatically close in the event of a rupture to the gauge or gauge line. Attending Marine Inspector found that the valves for the fuel tank gauge were not capable of automatically closing. 46 CFR 182.440(a)(7)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Valves were replaced with self closing valves
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 November 2019 Resolved
Fixed fire extinguishing systems must have a device that automatically shuts down ventilation in the protected space. Attending MI found the dampers blocked by debris and hanging insulation. Vessel is not operating in compliance with the COI. 46CFR181.410(b)(10) 46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Insulation replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2019 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems it must meet SAE J-1492. Attending MI found the fuel return line was deteriorated and cracked at the manifold (starboard, forward engine room). 46CFR181.720(e)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Fuel Hose replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2019 Resolved
Fire hazards are to be minimized as far as reasonable and practicable. Attending MI identified an oily sheen/residue on all bulkheads, decks and overhead in the fuel tank space. Vessel is not operating in compliance with the COI. 46CFR177.405(a) 46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Space clean
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 November 2019 Resolved
Fixed fire extinguishing systems must have a device that automatically shuts down ventilation in the protected space. Attending MI discovered the fire dampers did not function when tested. Vessel is not operating in compliance with the COI. 46CFR181.410(b)(10) 46CFR176.100(b)
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Witness proper operation of Fixed System and shutdowns.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 November 2019 Resolved
Each battery used in an item of lifesaving must be replaced when expired. Attending MI found the float light battery had expired in 2015. 46CFR185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 2 December 2019
Resolution: Battery replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 November 2019 Resolved
The engine head, clock and exhaust manifold must be water-jacketed and cooled by water from a pump when the engine is running. Attending MI found a coolant leak coming from the forward end of the center engine. 46CFR182.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 2 December 2019
Resolution: Leak fixed
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 23 November 2019 Resolved
Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and authorized route. Attending MI found the windows throughout the passenger accommodations and on the bridge were cracked. 46CFR177.1020
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2019
Resolved 5 February 2020
Resolution: Conducted COI scope inspection of vessel which resulted in 00 defs issued while clearing all outstanding items.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019 Resolved
This vessel is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel. 46CFR176.25-50
Action required: 30 - Ship detained
Resolved 2 December 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2019 Resolved
Vessel must demonstrate functional high level alarm for starboard side bilge. Cite: 46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 2 July 2019
Resolution: Observed satisfactory test of alarms.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 June 2019 Resolved
The owner, charterer, master, or managing operator must ensure the deckhand identified can perform in an emergency in accordance with 46CFR185.420 and demonstrate to the Coast Guard. 705 c: To be cleared by Monday 24JUN2019. Cite: 46CFR185.420(a)
Action required: 705 - Other - as specified
Due 24 June 2019
Resolved 2 July 2019
Resolution: Observed satisfactory man overboard drill.
Construction/Loadline › Hull › Bottom Plating
Issued 24 May 2018 Resolved
Crop/renew 1/4" hull plating in #2 void, second bay stbd side. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 25 May 2018
Resolution: Verified fitup, back gouge, and final welds/NDT (dye penetrant) same day; all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2017 Resolved
Vessel radio certificate is expired. Vessel is restricted to 1,000 ft from shore until a new certificate is issued.
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 20 June 2017
Resolution: Attended vessel and viewed newly issued FCC radio certificate.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 31 May 2016 Resolved
Ground detection not provides for the a/c system. Ground detection must be provided for a dual voltage generator installation IAW 46 CFR 183.324(c). Provide plan for approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 8 August 2018
Resolution: Vessel had ground detection installed. system tested all sat.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 31 May 2016 Resolved
Fire pump is electrically driven, power sources that power vital systems listed in 182.710 must have two sources of electricity.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 8 August 2018
Resolution: Vessel provided 2 sources of power for the fire pump.
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 May 2016 Resolved
Toilet is seawater feded from the fire pump piping. The hose to the toilet is not J1942. Cap at tee or provide hose that meets J1942.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 9 June 2017
Resolution: Cleared during annual inspection. Toilet and piping removed from vessel.
Construction/Loadline › Penetrations › Weld
Issued 1 May 2012 Resolved
JR1- Inboard Starboard loading platform mount to prevent collisions when loading has crack in weld. V and Weld.
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 15 May 2012
Resolution: The mount has been properly repaired to the satisfaction of attending marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 1 May 2012 Resolved
JR2-Aft Starboard Rubrail is damaged. Crop and Renew.
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 15 May 2012
Resolution: Repaired to the satisfaction of attending CG marine inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 1 May 2012 Resolved
JR3"V and Weld" 3 welds as marked starboard side 3 frames back and 1 weld port side 3 frames back.
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 15 May 2012
Resolution: Repaired to the satisfaction of attending CG marine inspector.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 1 May 2012 Resolved
JR 4- Remove dead end wire in fuel tank room in way of generator bilge and overhead.
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 15 May 2012
Resolution: Repaired to the satisfaction of attending CG marine inspector.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 May 2012 Resolved
JR 5 - Remove oil from bilges in Fuel Tank Room.
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 1 May 2012
Resolution: Bilges were cleaned prior to completion of the exam.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 1 May 2012 Resolved
JR6- Remove oil from main generator box.
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 1 May 2012
Resolution: Oil was removed prior to exam completion.
Engineering › Generator (propulsion-electric) › Winding
Issued 1 May 2012 Resolved
JR7- Demonstrate proper operation main generator seal. Investigate cause of main generator oil leak and report to CGMI.
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 15 May 2012
Resolution: Repaired to the satisfaction of attending CG marine inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 8 December 2005 Resolved
Vsl reported loss to all 03 MDE's.
Action required: 705 - Other - as specified
Resolved 22 December 2005
Resolution: Received tech report attesting to the proper operation of all 3 MDE''''s. Report determined that loss of power was due to faulty wiring in E/R. All wiring was replaced in kind, and the vessel passed a successful twenty - minute sea trial.
Construction/Loadline › Structures › Superstructure
Issued 1 December 2004 Resolved
Vessel's overhead superstructure was damaged while tied to the pier and out of service.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 May 2005
Resolved 10 May 2005
Resolution: Overhead superstructure repaired to satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 October 2004 Resolved
Repair broken weld on bow gate hinge.
Due 4 November 2004
Resolved 9 November 2004
Resolution: Bow Gate Welded as Proposed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 October 2004 Resolved
Repair broken weld on gate hinge (starboard side).
Due 4 November 2004
Resolved 9 November 2004
Resolution: Gate Hinge welded as Proposed.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 27 October 2004 Resolved
Provide metal supports on wiring not more than 24 inches apart in lazarette, fuel tank space, and void #2 as per 46 CFR 183.340.
Due 4 November 2004
Resolved 9 November 2004
Resolution: Metal Supports Added Every 24 Inches as Proposed.
Lifesaving › Hand Flares › Quantity
Issued 27 October 2004 Resolved
Provide (6) orange day smoke flares as per 46 CFR 180.68 (a)(i).
Due 4 November 2004
Resolved 9 November 2004
Resolution: 06 Day Smokes Added to Flare Kit as Proposed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 October 2004 Resolved
Provide second portable light at entrance to machinery space as per 46 CFR 184.30-1.
Due 4 November 2004
Resolved 9 November 2004
Resolution: Second Portable Light Added as Proposed.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 December 2003 Resolved
Provide proper operation of 30 sec. time delay for e/r fixed system.
Due 10 December 2003
Resolved 16 December 2003
Stability › Watertight Integrity
Issued 3 December 2003 Resolved
Make aft bulkhead in void #1 watertight.
Due 10 December 2003
Resolved 16 December 2003
Communications › Internal Communications System
Issued 3 December 2003 Resolved
Make proper repair to public address system.
Due 10 December 2003
Resolved 16 December 2003
Stability
Issued 6 December 2001 Resolved
Vessel shall not be placed into passenger carrying service until an approved stability letter is issued by the U.S. Coast Guard Marine Safety Center and posted onboard the vessel. LEGACY COMPONENT DESC: Stability Letter
Due 30 January 2002
Resolved 15 January 2002
Resolution: Have copy of stability letter
Operations/Management › Passenger Operations
Issued 6 December 2001 Resolved
Vessel shall not be placed into passenger carrying service until a new to zone inspection is completed by a U.S. Coast Guard Activities New York Marine Inspector.
Due 30 January 2002
Resolved 15 January 2002
Resolution: Completed NTZ inspection on this date
Operations/Management › Drills/Instruction
Issued 6 December 2001 Resolved
Vessel shall not be placed into passenger carrying service until Fire, Person Overboard, and Abandon Ship drills are conducted.
Due 30 January 2002
Resolved 15 January 2002
Resolution: Drills conducted

Casualty record · 2

8 December 2005Routine · role: Involved in a Marine Casualty · activity 2559839
27 August 2024Routine · role: Involved in a Marine Casualty · activity 7995512
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.