BROOKLYN is a 2002 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in May 2026, along with 33 deficiencies, 3 operational controls and 3 casualty investigations between 2011 and 2016.

Records from 2011 to 2026. Most recent: inspection, 21 May 2026.

Built
2002
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA 8190
561925
Flag
UNITED STATES
Maury page id
psix-561925

Documentation record

Registered dimensions (L × B × D)78.5 ft × 28.5 ft × 8.3 ft
Registered tonnagegross 82 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE INC · SITKA, AK, UNITED STATES · built 2002
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationTwin Hull
Hailing portWEEHAWKEN, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 20

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FIORELLO LAGUARDIA Passenger (Inspected) · MISLE 36 · 18 November 2019 · activity 6896988YOGI BERRA Passenger (Inspected) · MISLE 38 · 18 November 2019 · activity 6896988COMMONWEALTH Passenger (Inspected) · MISLE 36922 · 18 November 2019 · activity 6896988FATHER MYCHAL JUDGE Passenger (Inspected) · MISLE 39724 · 18 November 2019 · activity 6896988PORT IMPERIAL MANHATTAN Passenger (Inspected) · MISLE 284655 · 18 November 2019 · activity 6896988GEORGE WASHINGTON Passenger (Inspected) · MISLE 330751 · 18 November 2019 · activity 6896988THOMAS JEFFERSON Passenger (Inspected) · MISLE 330756 · 18 November 2019 · activity 6896988ALEXANDER HAMILTON Passenger (Inspected) · MISLE 330758 · 18 November 2019 · activity 6896988HENRY HUDSON Passenger (Inspected) · MISLE 382715 · 18 November 2019 · activity 6896988EMPIRE STATE Passenger (Inspected) · MISLE 396679 · 18 November 2019 · activity 6896988JOHN STEVENS Passenger (Inspected) · MISLE 449770 · 18 November 2019 · activity 6896988U.S. SENATOR FRANK R LAUTENBERG Passenger (Inspected) · MISLE 561914 · 18 November 2019 · activity 6896988CRISPUS ATTUCKS Passenger (Inspected) · MISLE 566037 · 18 November 2019 · activity 6896988FRED V MORRONE Passenger (Inspected) · MISLE 566038 · 18 November 2019 · activity 6896988SUSAN B ANTHONY Passenger (Inspected) · MISLE 566298 · 18 November 2019 · activity 6896988CONGRESSMAN ROBERT A. ROE Passenger (Inspected) · MISLE 607128 · 18 November 2019 · activity 6896988GOVERNOR THOMAS H. KEAN Passenger (Inspected) · MISLE 608328 · 18 November 2019 · activity 6896988ADMIRAL RICHARD E BENNIS Passenger (Inspected) · MISLE 610847 · 18 November 2019 · activity 6896988YORK Passenger (Inspected) · MISLE 1081932 · 18 November 2019 · activity 6896988MOLLY PITCHER Passenger (Inspected) · MISLE 1278350 · 18 November 2019 · activity 6896988

Inspection history · 24

21 May 2026 Internal Structural Exam · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8377649
9 January 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8293937
5 November 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264843
5 March 2024 COI Inspection · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7874249
6 June 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704259
2 February 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7631264
8 April 2022 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7419804
23 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7417081
24 November 2021 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7356674
20 April 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179180
3 March 2020 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6919618
26 February 2020 Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6915799
5 December 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6868043
22 November 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6860946
18 November 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
15 April 2019 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6663013
30 April 2018 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6402276
10 April 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6387735
30 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297687
10 April 2017 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6121152
21 June 2016 Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5913972
20 June 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5980968
21 April 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5989825
7 April 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5849355

Deficiency record · 33

11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 May 2026 Resolved
Each vessel without overnight accommodations certificated to operate on a coastwise route, must:(1) ... be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board. MI's observed IBA removed from vessel for maintenance. 46CFR117.204(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2026
Resolution: Vsl provided proof necessary to clear
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2025 Resolved
Vessels to which this subchapter applies must meet the applicable provisions in Subchapter S of this chapter. Prior to the carriag eof pax, provide updated stability letter to local OCMI. 46 CFR 116.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2025
Resolution: Stability letter provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2023 Resolved
THE GENERAL CONSTRUCTION OF THE VESSEL MUST BE SUCH AS TO MINIMIZE FIRE HAZARDS INSOFAR AS IT IS REASONABLE AND PRACTICABLE. FURNACE PIPING LEADING TO EXTERIOR VESSEL HAS HOLES IN ELBOW. REMOVE WRAPPED LAGGING FOR FURTHER INSPECTION, SEND PICTURES OF CONDITION OF PIPING, AND MAKE NECESSARY REPAIRS AS DETERMINED BY ATTENDING MARINE INSPECTOR. FURNACE MAY NOT BE USED UNTIL THIS OFFICE RECEIVES PICTURES OF THIS ENTIRE PIPE, AND A REPAIR PROPOSAL FOR ANY NECESSARY REPAIRS. *RECEIVED PICTURES OF EXHAUST PIPING WITH LAGGING REMOVED. SHOWS SIGNS OF CORROSION/PITTING. PIPING MUST BE REPLACED PRIOR TO NEXT CREDIT DDX. UNTIL THEN, THE FURNACE MUST BE TAGGED OUT. 46 CFR 177.405(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 9 January 2026
Resolution: Spoke with Operator to confirm that furnace and its associated piping were removed during the T to K conversion project.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant OCMI. Discovered patch on port side outboard jet drive located in lazarrete. Remove patch, investigate and provide repair proposal for approval from OCMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 30 March 2020
Resolution: Witnessed pier side propulsion test, all satisfactory
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 February 2020 Resolved
At each inspection for certification of a vessel the owner/operator shall have vessel ready for inspection of the hull structure. #2 starboard void from keel, one frame up had multiple pits that met the 25% threshold. Clean and preserve all pitted areas. Vessel will crop and renew first frame from keel both port and starboard sides fwd to aft at upcoming dry dock.
Action required: 705 - Other - as specified
Due 26 February 2020
Resolved 12 March 2020
Resolution: Metal was cropped/renewed and went throught fit-up, backgouge, and NDT (dye pen) inspections. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2020 Resolved
At each inspection for certification all observed unsafe practices, fire hazards must be corrected. Port side engine room had smoke caused by exhaust leak or oil soaked lagging. Investigate and make permanent repairs to eliminate smoke.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 28 February 2020
Resolution: Exhaust lagging was determined to be the cause and replaced by the company.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020 Resolved
Each ungrounded system must be provided with ground detection system that provides continuous indication of circuit status to ground. 1 amp ground was observed on ships power. Investigate cause and isolate ground.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 15 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020 Resolved
Piping used in a vital system must be composed of nonferrous material. Vessels bilge suction line had rigid plastic installed. Remove and replace with proper material. 12MAR2020: Suctions replaced with metal fittings; starboard tank room suction not in place, in order to allow room for welding/moving the fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 15 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020 Resolved
On a vessel of at least 26ft in length bilge level alarms are required. Bilge alarm in in starboard lazarette sticks in the up position. Repair bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Bilge alarm was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020 Resolved
Each connection to a conductor or terminal must be made within an enclosure. Starboard bilge pump and alarm wiring were not in an enclosure. Place connected wires in watertight enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Wiring was placed into an enclosure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020 Resolved
The use of plastic tie wraps must be limited to to bundling or retention of multiple cable installations. Zip ties were used to hold both port and starboard J boxes in Port lazarette. Remove zip ties and permanently install j boxes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: J-boxes permanently mounted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2020 Resolved
Provide up to date crew list to reflect requirements for DAPI program. Vessel's captain was not on list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 4 March 2020
Resolution: Verified vessel captain was added to companies DAPI crew list.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 February 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's stern light was inoperable. Repair stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Nav light bulb was replaced and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020 Resolved
Machinery, equipment, materials, and arrangements not covered by standards may be inspected in accordance with standards acceptable to [name withheld] down straps were deteriorated. Replace or remove tie down straps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 4 March 2020
Resolution: Vessel removed deteriorated handicap tie down points and replaced with blanks.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 February 2020 Resolved
Operation of transmitter if any ship station must be performed by a person holding a commercial radio operator license or permit of the class required. Vessel's Captain did not have FCC Marine Radio Operator Permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 15 April 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Approximatley 4 inches of water with hydraulic fluid in port and stardboard lazerettes due to no properly securing hatch scuttles. 46 CFR 176.800(a).
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Engine shall be capable of maintianing constant marine load. Forward port MDE has oil leak in forward part of engine near timing gear. 46 CFR 182.182.(200)(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Vessel shall be operated in good marine practice. Several hydraulic soaked rags were discovewred on the wet deck tunnel between lazerette spaces. 46 CFR 176.800(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 14 February 2020
Resolution: Recieved photo of lazarette with oil soaked rags removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 December 2019 Resolved
A hatch exposed to the weather shall be watertight. Both lazerette hatches were found not dogged down correctly leading to water intrusion. Provide training to crew on hatch operation and securing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 14 February 2020
Resolution: Training was conducted
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 5 December 2019 Resolved
Punctured hold and bent frame in starboard generator void. Uppermost strake all the way forward on the starboard outboard side. C/R 18x18 and replace bent stiffener. Tie insert into existing welds, utilize radius corners and relief cuts as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 5 December 2019 Resolved
Damage IVO starboard forward cleat IWO rub rail. Repair will be as close to 18x18 as practicable. Weld will have 2 radius corners and 2 relief cuts where plate ties into existing weld.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019 Resolved
A pre-engineered fixed firefighting system must be approved by the Commandant and be installed in accordance with the manufacturer's instructions. Attending Marine Inspectors found the pre-engineered fixed firefighting system for the boiler had not been serviced since 2017 and was past due. Not in compliance with COI. 46CFR181.420 46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Preengineered system was serviced by Sea Safety.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019 Resolved
A pre-engineered fixed firefighting system must be approved by the Commandant and be installed in accordance with the manufacturer's instructions. Attending Marine Inspectors found both pre-engineered fixed firefighting systems were installed on generator enclosures that were not sealed as designed. Not in compliance with COI. 46CFR181.420 46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Generator covers were properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 November 2019 Resolved
On a vessel of at least 26', bilge high level alarms shall be provided in a machinery space bilge that is subject to flooding. Attending Marine Inspectors discovered the bilge high level alarms in both of the engine rooms were not mounted and would not provide the required audible and visual alarms at the operating station if water intrusion occurred. Not in compliance with COI. 46CFR182.530(a)(2) 46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: All bilge alarms properly mounted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 November 2019 Resolved
A hatch exposed to the weather must be watertight. Attending Marine Inspectors discovered that starboard engine room, port lazarette and starboard lazarette scuttles were not able to be dogged down. *7 days to rectify* 46CFR179.360(a)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Hatches repaired and function properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2019 Resolved
Piping that carries vapor, gases or liquids with temperatures exceeding 150 degrees F must be suitably insulated to prevent injuries. Attending Marine Inspectors found the insulation on the exhaust was falling off and exposing hot surfaces. *7 days to rectify* 46CFR177.970
Action required: 705 - Other - as specified
Resolved 25 November 2019
Resolution: Exhaust lagging has been properly replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 November 2019 Resolved
Each ring life buoy on a vessel must be approved in accordance with 46CFR160.050. Attending Marine Inspectors determined the grab lines on the ring buoy were deteriorated. *7 days to rectify* 46CFR180.70(b)(1)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Ring life buoy replaced and light properly mounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2019 Resolved
Each connection to a conductor or terminal part must be made within an enclosure. Attending Marine Inspectors discovered starboard lazarette bilge pump and alarm wire connections were not made in an enclosure. *7 days to rectify* 46CFR183.340(g)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Wire connections have been placed inside enclosure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2019 Resolved
The vessel YORK is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel. 46CFR176.25-50
Action required: 30 - Ship detained
Resolved 25 November 2019
Construction/Loadline › Hull › Hull Plating
Issued 10 April 2017 Resolved
Found hole in corner of port transom/lazaratte. Crop and renew identified area and repair to satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2017
Resolution: Visually inspected and witnessed dye penetrant NDT. All sat.
Fire Fighting › Fire Pumps › Pressure
Issued 10 April 2017 Resolved
Fire pump tested and only putting out 25 PSI at the pump outlet. Prove fire pump discharges water at 60 PSI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Replaced pump.
Engineering › Steering Gear System › Power Unit
Issued 21 June 2016 Resolved
01- Identify root cause and make all repairs necessary to restore proper operation to stbd outboard engine and jet propulsion unit. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2016
Resolution: Received Technical Report
Construction/Loadline › Hull › Hull Plating
Issued 21 June 2016 Resolved
Crop and renew damaged rub rail / deck edge and port bow area identified damaged as a result to collision with concrete pier to the satisfaction of the attending marine inspector. Due 04 Jul 2016
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 July 2016
Resolved 24 June 2016
Resolution: Damaged areas repaired IAW proposal

Casualty record · 3

27 December 2011Routine · role: Involved in a Marine Casualty · activity 4226752
30 January 2014Routine · role: Transiting Vicinity of Primary Subject · activity 4795626
20 June 2016Routine · role: Involved in a Marine Casualty · activity 5980968
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.