Records from 2002 to 2026. Most recent: inspection, 21 May 2026.
Inspection history · 60
21 May 2026
Internal Structural Exam · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8377649
9 January 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8293937
5 November 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264843
5 March 2024
COI Inspection · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7874249
6 June 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704259
2 February 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7631264
8 April 2022
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7419804
23 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7417081
24 November 2021
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7356674
20 April 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179180
3 March 2020
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6919618
26 February 2020
Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6915799
5 December 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6868043
22 November 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6860946
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
15 April 2019
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6663013
30 April 2018
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6402276
10 April 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6387735
30 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297687
10 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6121152
21 June 2016
Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5913972
20 June 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5980968
21 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5989825
7 April 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5849355
27 December 2011
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4214743
27 December 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4226752
27 April 2009
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3462400
16 April 2009
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 3453920
10 April 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3449946
22 July 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3277571
16 May 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3212928
28 April 2008
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3194246
3 July 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2981785
25 April 2007
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2916517
12 March 2007
Type not recorded
No type recorded · Maritime Safety & Security Team Cape Cod (91110) · Activity 2886276
6 February 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2867996
25 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2807931
29 September 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2790112
7 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2739196
28 July 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2727495
25 July 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2724505
16 May 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2651027
8 May 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2643965
5 April 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2617147
29 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2542552
22 August 2005
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2471455
19 July 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2431929
7 July 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2418277
21 June 2005
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2398379
15 April 2005
Annual Inspection · Construction Oversight · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2334749
29 March 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2322401
15 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2197154
2 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2184801
30 August 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2181493
6 May 2004
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2060432
14 April 2004
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2043717
9 April 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1771340
4 June 2002
In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1626243
23 May 2002
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1618516
1 April 2002
Construction Oversight · Initial Certification
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1609114
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 May 2026
Resolved
Each vessel without overnight accommodations certificated to operate on a coastwise route, must:(1) ... be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board. MI's observed IBA removed from vessel for maintenance. 46CFR117.204(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2026
Resolution: Vsl provided proof necessary to clear
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2025
Resolved
Vessels to which this subchapter applies must meet the applicable provisions in Subchapter S of this chapter. Prior to the carriag eof pax, provide updated stability letter to local OCMI.
46 CFR 116.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2025
Resolution: Stability letter provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2023
Resolved
THE GENERAL CONSTRUCTION OF THE VESSEL MUST BE SUCH AS TO MINIMIZE FIRE HAZARDS INSOFAR AS IT IS REASONABLE AND PRACTICABLE. FURNACE PIPING LEADING TO EXTERIOR VESSEL HAS HOLES IN ELBOW. REMOVE WRAPPED LAGGING FOR FURTHER INSPECTION, SEND PICTURES OF CONDITION OF PIPING, AND MAKE NECESSARY REPAIRS AS DETERMINED BY ATTENDING MARINE INSPECTOR. FURNACE MAY NOT BE USED UNTIL THIS OFFICE RECEIVES PICTURES OF THIS ENTIRE PIPE, AND A REPAIR PROPOSAL FOR ANY NECESSARY REPAIRS.
*RECEIVED PICTURES OF EXHAUST PIPING WITH LAGGING REMOVED. SHOWS SIGNS OF CORROSION/PITTING. PIPING MUST BE REPLACED PRIOR TO NEXT CREDIT DDX. UNTIL THEN, THE FURNACE MUST BE TAGGED OUT.
46 CFR 177.405(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 9 January 2026
Resolution: Spoke with Operator to confirm that furnace and its associated piping were removed during the T to K conversion project.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant OCMI. Discovered patch on port side outboard jet drive located in lazarrete. Remove patch, investigate and provide repair proposal for approval from OCMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 30 March 2020
Resolution: Witnessed pier side propulsion test, all satisfactory
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 February 2020
Resolved
At each inspection for certification of a vessel the owner/operator shall have vessel ready for inspection of the hull structure. #2 starboard void from keel, one frame up had multiple pits that met the 25% threshold. Clean and preserve all pitted areas. Vessel will crop and renew first frame from keel both port and starboard sides fwd to aft at upcoming dry dock.
Action required: 705 - Other - as specified
Due 26 February 2020
Resolved 12 March 2020
Resolution: Metal was cropped/renewed and went throught fit-up, backgouge, and NDT (dye pen) inspections. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2020
Resolved
At each inspection for certification all observed unsafe practices, fire hazards must be corrected. Port side engine room had smoke caused by exhaust leak or oil soaked lagging. Investigate and make permanent repairs to eliminate smoke.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 28 February 2020
Resolution: Exhaust lagging was determined to be the cause and replaced by the company.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Each ungrounded system must be provided with ground detection system that provides continuous indication of circuit status to ground. 1 amp ground was observed on ships power. Investigate cause and isolate ground.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 15 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020
Resolved
Piping used in a vital system must be composed of nonferrous material. Vessels bilge suction line had rigid plastic installed. Remove and replace with proper material.
12MAR2020: Suctions replaced with metal fittings; starboard tank room suction not in place, in order to allow room for welding/moving the fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 15 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020
Resolved
On a vessel of at least 26ft in length bilge level alarms are required. Bilge alarm in in starboard lazarette sticks in the up position. Repair bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Bilge alarm was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Each connection to a conductor or terminal must be made within an enclosure. Starboard bilge pump and alarm wiring were not in an enclosure. Place connected wires in watertight enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Wiring was placed into an enclosure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
The use of plastic tie wraps must be limited to to bundling or retention of multiple cable installations. Zip ties were used to hold both port and starboard J boxes in Port lazarette. Remove zip ties and permanently install j boxes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: J-boxes permanently mounted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2020
Resolved
Provide up to date crew list to reflect requirements for DAPI program. Vessel's captain was not on list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 4 March 2020
Resolution: Verified vessel captain was added to companies DAPI crew list.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 February 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's stern light was inoperable. Repair stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Nav light bulb was replaced and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Machinery, equipment, materials, and arrangements not covered by standards may be inspected in accordance with standards acceptable to [name withheld] down straps were deteriorated. Replace or remove tie down straps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 4 March 2020
Resolution: Vessel removed deteriorated handicap tie down points and replaced with blanks.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 February 2020
Resolved
Operation of transmitter if any ship station must be performed by a person holding a commercial radio operator license or permit of the class required. Vessel's Captain did not have FCC Marine Radio Operator Permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 15 April 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Approximatley 4 inches of water with hydraulic fluid in port and stardboard lazerettes due to no properly securing hatch scuttles. 46 CFR 176.800(a).
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Engine shall be capable of maintianing constant marine load. Forward port MDE has oil leak in forward part of engine near timing gear. 46 CFR 182.182.(200)(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Vessel shall be operated in good marine practice. Several hydraulic soaked rags were discovewred on the wet deck tunnel between lazerette spaces.
46 CFR 176.800(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 14 February 2020
Resolution: Recieved photo of lazarette with oil soaked rags removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 December 2019
Resolved
A hatch exposed to the weather shall be watertight. Both lazerette hatches were found not dogged down correctly leading to water intrusion. Provide training to crew on hatch operation and securing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 14 February 2020
Resolution: Training was conducted
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 5 December 2019
Resolved
Punctured hold and bent frame in starboard generator void. Uppermost strake all the way forward on the starboard outboard side. C/R 18x18 and replace bent stiffener. Tie insert into existing welds, utilize radius corners and relief cuts as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 5 December 2019
Resolved
Damage IVO starboard forward cleat IWO rub rail. Repair will be as close to 18x18 as practicable. Weld will have 2 radius corners and 2 relief cuts where plate ties into existing weld.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019
Resolved
A pre-engineered fixed firefighting system must be approved by the Commandant and be installed in accordance with the manufacturer's instructions. Attending Marine Inspectors found the pre-engineered fixed firefighting system for the boiler had not been serviced since 2017 and was past due. Not in compliance with COI.
46CFR181.420
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Preengineered system was serviced by Sea Safety.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019
Resolved
A pre-engineered fixed firefighting system must be approved by the Commandant and be installed in accordance with the manufacturer's instructions. Attending Marine Inspectors found both pre-engineered fixed firefighting systems were installed on generator enclosures that were not sealed as designed. Not in compliance with COI.
46CFR181.420
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Generator covers were properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 November 2019
Resolved
On a vessel of at least 26', bilge high level alarms shall be provided in a machinery space bilge that is subject to flooding. Attending Marine Inspectors discovered the bilge high level alarms in both of the engine rooms were not mounted and would not provide the required audible and visual alarms at the operating station if water intrusion occurred. Not in compliance with COI.
46CFR182.530(a)(2)
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: All bilge alarms properly mounted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 November 2019
Resolved
A hatch exposed to the weather must be watertight. Attending Marine Inspectors discovered that starboard engine room, port lazarette and starboard lazarette scuttles were not able to be dogged down.
*7 days to rectify*
46CFR179.360(a)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Hatches repaired and function properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2019
Resolved
Piping that carries vapor, gases or liquids with temperatures exceeding 150 degrees F must be suitably insulated to prevent injuries. Attending Marine Inspectors found the insulation on the exhaust was falling off and exposing hot surfaces.
*7 days to rectify*
46CFR177.970
Action required: 705 - Other - as specified
Resolved 25 November 2019
Resolution: Exhaust lagging has been properly replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 November 2019
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46CFR160.050. Attending Marine Inspectors determined the grab lines on the ring buoy were deteriorated.
*7 days to rectify*
46CFR180.70(b)(1)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Ring life buoy replaced and light properly mounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2019
Resolved
Each connection to a conductor or terminal part must be made within an enclosure. Attending Marine Inspectors discovered starboard lazarette bilge pump and alarm wire connections were not made in an enclosure.
*7 days to rectify*
46CFR183.340(g)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Wire connections have been placed inside enclosure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2019
Resolved
The vessel YORK is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.25-50
Action required: 30 - Ship detained
Resolved 25 November 2019
Construction/Loadline › Hull › Hull Plating
Issued 10 April 2017
Resolved
Found hole in corner of port transom/lazaratte. Crop and renew identified area and repair to satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2017
Resolution: Visually inspected and witnessed dye penetrant NDT. All sat.
Fire Fighting › Fire Pumps › Pressure
Issued 10 April 2017
Resolved
Fire pump tested and only putting out 25 PSI at the pump outlet. Prove fire pump discharges water at 60 PSI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Replaced pump.
Engineering › Steering Gear System › Power Unit
Issued 21 June 2016
Resolved
01- Identify root cause and make all repairs necessary to restore proper operation to stbd outboard engine and jet propulsion unit. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2016
Resolution: Received Technical Report
Construction/Loadline › Hull › Hull Plating
Issued 21 June 2016
Resolved
Crop and renew damaged rub rail / deck edge and port bow area identified damaged as a result to collision with concrete pier to the satisfaction of the attending marine inspector. Due 04 Jul 2016
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 July 2016
Resolved 24 June 2016
Resolution: Damaged areas repaired IAW proposal
Construction/Loadline › Hull › Hull Plating
Issued 27 December 2011
Resolved
Crop and renew damaged hull plating in way of starboard engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2011
Resolved 30 December 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 April 2009
Resolved
V/weld two welds on port side railing in way of lazarette space.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 16 April 2010
Resolution: Verified suitable railing in way of lazarette space.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 2 May 2008
Resolved
Repair cracked and bent hatches; port and stbd side hatches for fuel and engine voids have cracked and bent knife edges, as well as missing dogging system.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 16 May 2008
Communications › Radio Communications › EPIRB
Issued 25 April 2007
Resolved
Replace disposable hydrostatic release unit in way of 406MHz EPIRB.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 25 April 2007
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 25 April 2007
Resolved
Provide and post Emergency Instructions.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 25 April 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 April 2007
Resolved
Replace mounting bracket in way of portable fire extinguisher, starboard side, aft, main deck.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 25 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2006
Resolved
Terminate dead end wires on all engine gauge boxes in Engine Room.
Condition: Damaged By Earlier Event
Due 22 May 2006
Resolved 12 June 2006
Lifesaving › Hand Flares › Quantity
Issued 8 May 2006
Resolved
Provide 2 red and 3 orange hand flares.
Condition: Improper Installation
Due 22 May 2006
Resolved 8 May 2006
Documentation › Certificates/Documents › FCC SSL
Issued 8 May 2006
Resolved
Provide FCC Safety Radio Certificate- Vessel is restricted to Not more than 1000 feet from shore until NY03 is cleared.
Condition: Unknown
Due 22 May 2006
Resolved 12 June 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 May 2006
Resolved
Conduct MOB and Fired Drills and Log as necessary.
Condition: Improper/Lack of Maintenance
Due 22 May 2006
Resolved 12 June 2006
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 8 May 2006
Resolved
Post emergency instructions list on vessel.
Condition: Improper/Lack of Maintenance
Due 22 May 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 April 2006
Resolved
Repair aft top of ladder spindle port side.
Due 10 May 2006
Resolved 8 May 2006
Construction/Loadline › Hull › Bracket
Issued 21 June 2005
Resolved
C/R port side bow bumper rail bracketing system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 August 2005
Resolution: Permanent/Proper Repairs have been carried out IAW the port/stbd. bumper rail system.
Construction/Loadline › Structures › Superstructure
Issued 14 April 2005
Resolved
V/W handrail IWO bow and port quarter.
Condition: Damaged By Earlier Event
Due 28 April 2005
Resolved 20 June 2005
Resolution: V/W handrails as proper.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 April 2005
Resolved
Post COI so that all pages are visible.
Due 28 April 2005
Resolved 20 June 2005
Resolution: Posted Same.
Construction/Loadline › Hull
Issued 10 May 2004
Resolved
C/R stbd hull forepeak transverse frame IWO chine. LEGACY COMPONENT DESC: Transverse Frame
Due 10 May 2004
Resolved 11 May 2004
Construction/Loadline › Hull
Issued 6 May 2004
Resolved
C/R port hull void #2 transverse frame IWO chine. Vessel is restricted from carring passengers until this requirement is met. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2004
Resolved 10 May 2004
Construction/Loadline › Hull
Issued 6 May 2004
Resolved
V/W port forepeak transverse frames IWO chine as marked. LEGACY COMPONENT DESC: Transverse Frame
Due 13 May 2004
Resolved 10 May 2004
Construction/Loadline › Hull
Issued 6 May 2004
Resolved
V/W stbd forepeak transverse frames IWO chine as marked. LEGACY COMPONENT DESC: Transverse Frame
Due 13 May 2004
Resolved 18 May 2004
Construction/Loadline › Hull
Issued 6 May 2004
Resolved
V/W port void #2 transverse frames IWO chine as marked. LEGACY COMPONENT DESC: Transverse Frame
Due 13 May 2004
Resolved 10 May 2004
Construction/Loadline › Hull
Issued 6 May 2004
Resolved
V/W stbd void #2 transverse frames IWO chine as marked. LEGACY COMPONENT DESC: Transverse Frame
Due 13 May 2004
Resolved 10 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 6 May 2004
Resolved
Properly repair damaged bottom rail on stbd bow gate. LEGACY COMPONENT DESC: Deck Rail
Due 13 May 2004
Resolved 10 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 6 May 2004
Resolved
V/W top hinge on port bow gate. LEGACY COMPONENT DESC: Deck Rail
Due 13 May 2004
Resolved 10 May 2004
Navigation › Piloting/Steering
Issued 6 May 2004
Resolved
Prove proper operation of magnetic compass light. LEGACY COMPONENT DESC: Magnetic Compass
Due 13 May 2004
Resolved 10 May 2004
Fire Fighting › Fire Pumps
Issued 6 May 2004
Resolved
Prove proper operation of fire pump to a pressure of 60psi. Vessel is restricted to carring passengers until this requirement is met.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2004
Resolved 10 May 2004
Construction/Loadline › Hull
Issued 23 April 2004
Resolved
Make permanent repairs to bow radius. LEGACY COMPONENT DESC: Hull Plating
Due 21 May 2004
Resolved 18 May 2004
Accommodation/Occupational Safety
Issued 1 April 2002
Resolved
Seating not installed. To be installed in Florida on way to New York LEGACY COMPONENT DESC: Seating
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 April 2002
Resolved
Lifejackets are in boxes on departure. To be installed after seats are installed. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2002
Resolved 4 June 2002
Lifesaving
Issued 1 April 2002
Resolved
Conduct drills using new man-over-board recovery system. LEGACY COMPONENT DESC: Man-over-board recovery system
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2002
Resolved 4 June 2002
Operations/Management
Issued 1 April 2002
Resolved
Make the vessel available for a new-to-zone inspection and underway equipment tests and drills to the satisfaction of the Officer in Charge, Marine Inspection New York, prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2002