Records from 2011 to 2026. Most recent: inspection, 21 May 2026.
Inspection history · 24
21 May 2026
Internal Structural Exam · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8377649
9 January 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8293937
5 November 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264843
5 March 2024
COI Inspection · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7874249
6 June 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704259
2 February 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7631264
8 April 2022
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7419804
23 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7417081
24 November 2021
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7356674
20 April 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179180
3 March 2020
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6919618
26 February 2020
Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6915799
5 December 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6868043
22 November 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6860946
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
15 April 2019
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6663013
30 April 2018
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6402276
10 April 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6387735
30 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297687
10 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6121152
21 June 2016
Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5913972
20 June 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5980968
21 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5989825
7 April 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5849355
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 May 2026
Resolved
Each vessel without overnight accommodations certificated to operate on a coastwise route, must:(1) ... be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board. MI's observed IBA removed from vessel for maintenance. 46CFR117.204(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2026
Resolution: Vsl provided proof necessary to clear
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2025
Resolved
Vessels to which this subchapter applies must meet the applicable provisions in Subchapter S of this chapter. Prior to the carriag eof pax, provide updated stability letter to local OCMI.
46 CFR 116.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2025
Resolution: Stability letter provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2023
Resolved
THE GENERAL CONSTRUCTION OF THE VESSEL MUST BE SUCH AS TO MINIMIZE FIRE HAZARDS INSOFAR AS IT IS REASONABLE AND PRACTICABLE. FURNACE PIPING LEADING TO EXTERIOR VESSEL HAS HOLES IN ELBOW. REMOVE WRAPPED LAGGING FOR FURTHER INSPECTION, SEND PICTURES OF CONDITION OF PIPING, AND MAKE NECESSARY REPAIRS AS DETERMINED BY ATTENDING MARINE INSPECTOR. FURNACE MAY NOT BE USED UNTIL THIS OFFICE RECEIVES PICTURES OF THIS ENTIRE PIPE, AND A REPAIR PROPOSAL FOR ANY NECESSARY REPAIRS.
*RECEIVED PICTURES OF EXHAUST PIPING WITH LAGGING REMOVED. SHOWS SIGNS OF CORROSION/PITTING. PIPING MUST BE REPLACED PRIOR TO NEXT CREDIT DDX. UNTIL THEN, THE FURNACE MUST BE TAGGED OUT.
46 CFR 177.405(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 9 January 2026
Resolution: Spoke with Operator to confirm that furnace and its associated piping were removed during the T to K conversion project.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant OCMI. Discovered patch on port side outboard jet drive located in lazarrete. Remove patch, investigate and provide repair proposal for approval from OCMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 30 March 2020
Resolution: Witnessed pier side propulsion test, all satisfactory
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 February 2020
Resolved
At each inspection for certification of a vessel the owner/operator shall have vessel ready for inspection of the hull structure. #2 starboard void from keel, one frame up had multiple pits that met the 25% threshold. Clean and preserve all pitted areas. Vessel will crop and renew first frame from keel both port and starboard sides fwd to aft at upcoming dry dock.
Action required: 705 - Other - as specified
Due 26 February 2020
Resolved 12 March 2020
Resolution: Metal was cropped/renewed and went throught fit-up, backgouge, and NDT (dye pen) inspections. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2020
Resolved
At each inspection for certification all observed unsafe practices, fire hazards must be corrected. Port side engine room had smoke caused by exhaust leak or oil soaked lagging. Investigate and make permanent repairs to eliminate smoke.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 28 February 2020
Resolution: Exhaust lagging was determined to be the cause and replaced by the company.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Each ungrounded system must be provided with ground detection system that provides continuous indication of circuit status to ground. 1 amp ground was observed on ships power. Investigate cause and isolate ground.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2020
Resolved 15 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020
Resolved
Piping used in a vital system must be composed of nonferrous material. Vessels bilge suction line had rigid plastic installed. Remove and replace with proper material.
12MAR2020: Suctions replaced with metal fittings; starboard tank room suction not in place, in order to allow room for welding/moving the fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 15 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020
Resolved
On a vessel of at least 26ft in length bilge level alarms are required. Bilge alarm in in starboard lazarette sticks in the up position. Repair bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Bilge alarm was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Each connection to a conductor or terminal must be made within an enclosure. Starboard bilge pump and alarm wiring were not in an enclosure. Place connected wires in watertight enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Wiring was placed into an enclosure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
The use of plastic tie wraps must be limited to to bundling or retention of multiple cable installations. Zip ties were used to hold both port and starboard J boxes in Port lazarette. Remove zip ties and permanently install j boxes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: J-boxes permanently mounted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2020
Resolved
Provide up to date crew list to reflect requirements for DAPI program. Vessel's captain was not on list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 4 March 2020
Resolution: Verified vessel captain was added to companies DAPI crew list.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 February 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's stern light was inoperable. Repair stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 28 February 2020
Resolution: Nav light bulb was replaced and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
Machinery, equipment, materials, and arrangements not covered by standards may be inspected in accordance with standards acceptable to [name withheld] down straps were deteriorated. Replace or remove tie down straps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 4 March 2020
Resolution: Vessel removed deteriorated handicap tie down points and replaced with blanks.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 February 2020
Resolved
Operation of transmitter if any ship station must be performed by a person holding a commercial radio operator license or permit of the class required. Vessel's Captain did not have FCC Marine Radio Operator Permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 15 April 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Approximatley 4 inches of water with hydraulic fluid in port and stardboard lazerettes due to no properly securing hatch scuttles. 46 CFR 176.800(a).
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Engine shall be capable of maintianing constant marine load. Forward port MDE has oil leak in forward part of engine near timing gear. 46 CFR 182.182.(200)(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Vessel shall be operated in good marine practice. Several hydraulic soaked rags were discovewred on the wet deck tunnel between lazerette spaces.
46 CFR 176.800(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 14 February 2020
Resolution: Recieved photo of lazarette with oil soaked rags removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 December 2019
Resolved
A hatch exposed to the weather shall be watertight. Both lazerette hatches were found not dogged down correctly leading to water intrusion. Provide training to crew on hatch operation and securing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 14 February 2020
Resolution: Training was conducted
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 5 December 2019
Resolved
Punctured hold and bent frame in starboard generator void. Uppermost strake all the way forward on the starboard outboard side. C/R 18x18 and replace bent stiffener. Tie insert into existing welds, utilize radius corners and relief cuts as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 5 December 2019
Resolved
Damage IVO starboard forward cleat IWO rub rail. Repair will be as close to 18x18 as practicable. Weld will have 2 radius corners and 2 relief cuts where plate ties into existing weld.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019
Resolved
A pre-engineered fixed firefighting system must be approved by the Commandant and be installed in accordance with the manufacturer's instructions. Attending Marine Inspectors found the pre-engineered fixed firefighting system for the boiler had not been serviced since 2017 and was past due. Not in compliance with COI.
46CFR181.420
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Preengineered system was serviced by Sea Safety.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019
Resolved
A pre-engineered fixed firefighting system must be approved by the Commandant and be installed in accordance with the manufacturer's instructions. Attending Marine Inspectors found both pre-engineered fixed firefighting systems were installed on generator enclosures that were not sealed as designed. Not in compliance with COI.
46CFR181.420
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Generator covers were properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 November 2019
Resolved
On a vessel of at least 26', bilge high level alarms shall be provided in a machinery space bilge that is subject to flooding. Attending Marine Inspectors discovered the bilge high level alarms in both of the engine rooms were not mounted and would not provide the required audible and visual alarms at the operating station if water intrusion occurred. Not in compliance with COI.
46CFR182.530(a)(2)
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: All bilge alarms properly mounted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 November 2019
Resolved
A hatch exposed to the weather must be watertight. Attending Marine Inspectors discovered that starboard engine room, port lazarette and starboard lazarette scuttles were not able to be dogged down.
*7 days to rectify*
46CFR179.360(a)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Hatches repaired and function properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2019
Resolved
Piping that carries vapor, gases or liquids with temperatures exceeding 150 degrees F must be suitably insulated to prevent injuries. Attending Marine Inspectors found the insulation on the exhaust was falling off and exposing hot surfaces.
*7 days to rectify*
46CFR177.970
Action required: 705 - Other - as specified
Resolved 25 November 2019
Resolution: Exhaust lagging has been properly replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 November 2019
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46CFR160.050. Attending Marine Inspectors determined the grab lines on the ring buoy were deteriorated.
*7 days to rectify*
46CFR180.70(b)(1)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Ring life buoy replaced and light properly mounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2019
Resolved
Each connection to a conductor or terminal part must be made within an enclosure. Attending Marine Inspectors discovered starboard lazarette bilge pump and alarm wire connections were not made in an enclosure.
*7 days to rectify*
46CFR183.340(g)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Wire connections have been placed inside enclosure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2019
Resolved
The vessel YORK is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.25-50
Action required: 30 - Ship detained
Resolved 25 November 2019
Construction/Loadline › Hull › Hull Plating
Issued 10 April 2017
Resolved
Found hole in corner of port transom/lazaratte. Crop and renew identified area and repair to satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2017
Resolution: Visually inspected and witnessed dye penetrant NDT. All sat.
Fire Fighting › Fire Pumps › Pressure
Issued 10 April 2017
Resolved
Fire pump tested and only putting out 25 PSI at the pump outlet. Prove fire pump discharges water at 60 PSI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Replaced pump.
Engineering › Steering Gear System › Power Unit
Issued 21 June 2016
Resolved
01- Identify root cause and make all repairs necessary to restore proper operation to stbd outboard engine and jet propulsion unit. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2016
Resolution: Received Technical Report
Construction/Loadline › Hull › Hull Plating
Issued 21 June 2016
Resolved
Crop and renew damaged rub rail / deck edge and port bow area identified damaged as a result to collision with concrete pier to the satisfaction of the attending marine inspector. Due 04 Jul 2016
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 July 2016
Resolved 24 June 2016
Resolution: Damaged areas repaired IAW proposal