Records from 2008 to 2026. Most recent: inspection, 6 May 2026.
Inspection history · 21
6 May 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8341462
10 July 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8172135
12 June 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7898148
29 May 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7923321
26 March 2024
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7862927
16 May 2023
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7672854
11 April 2022
COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7428672
15 March 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7408614
15 October 2020
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7076153
11 May 2020
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6948426
21 January 2020
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6893313
21 November 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6860912
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
3 May 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6676035
14 May 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6413792
4 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6405465
2 November 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6299652
3 May 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6138284
19 July 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5973116
16 May 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5878343
9 May 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5872238
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 22 May 2024
Resolved
When the Marine Safety Center (MSC) determines that a vessel must have stability details and/or calculations indicated on it Certificate of Inspection, the owner or operator must submit such information to the Commanding Officer, MSC for approval. Vessel's previous stability letter was held in abeyance pending submittal of structural calculations due to aft deck extension and modifications. Obtain stability letter based on recent weight change and structural calculations prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 May 2023
Resolved
A hatch exposed to the weather must be watertight. The watertight hatches to leading to the tank void and engine room are missing several dogs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 19 May 2023
Resolution: Repaired in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2022
Resolved
Shut off valves must be installed at the engine end of the fuel line. The vessel's fuel shutoff valve does not fully close. Make the valve fully functional at closing the fuel delivery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 22 April 2022
Resolution: Fuel shut-off valve is fully operational as per the regulation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 August 2020
Resolved
Fixed fire extinguishing system pressure switches were relocated outside the E/R. Prove proper operation of pressure swiches for ventiliation and engine shutdowns prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2020
Resolved 15 October 2020
Resolution: Tested during COI inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 11 May 2020
Resolved
Port side #2 transverse frame from aft at the bilge knuckle was cracked in the generator/fuel tank space. Gouge and reweld crack.
Action required: 705 - Other - as specified
Due 11 May 2020
Resolved 16 June 2020
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2020
Resolved
Vessel found with hull penetration in tank space between aft bulkhead and frame on starboard side. Light visibly seen within penetration.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2020
Resolved 28 April 2020
Resolution: Observed as satisfactory by attending MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2020
Resolved
Vessel lifejacket stowage not marked as well as stowage of vessels was found to require significant dexterity which prevented the rapid removal of lifejacket from stowage location.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2020
Resolved 28 April 2020
Resolution: Observed as satisfactory by attending MIs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 November 2019
Resolved
Fire hazards are to be minimized as it is reasonable and practicable. Attending Marine Inspector (MI) noted oil-soaked rags along with approximately 1.5" of diesel/oil/water mixture accumulated in the engine room bilge. Vessel is not operating in compliance with the COI.
46 CFR 177.405(a)
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Engine room has been properly cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2019
Resolved
On a vessel of at least 26', a visual and audible alarm must be provided at the operating station to indicate high water level in normally unmanned spaces. Attending MI discovered the engine room bilge alarm float switches were not properly installed and would not be capable of alarming at the operating station. Vessel is not operating in compliance with the COI.
46 CFR 182.530(a)(2)
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Bilge float switches are properly installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2019
Resolved
A pre-engineered fixed gas extinguishing system must be installed in accordance with the manufacturer's instructions. Attending MI found the generator enclosure was missing panels and would not allow for effective operation of the attached fixed system. Vessel is not operating in compliance with the COI.
46 CFR 181.420(a)(4)
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Panels were replaced on the generator box.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 November 2019
Resolved
A hatch exposed to the weather must be watertight. Attending MI discovered that the bow forward and breaker room hatches were inoperable and could not be closed.
46 CFR 179.360(a)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Scuttles have been repaired and function properly.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2019
Resolved
A crew work space must be of sufficient size, adequate construction and with suitable equipment to provide for the safe operation of the vessel and the protection of personnel. Attending MI discovered the jet drive bucket inspection platform deck plates were missing.
46CFR177.700(a)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Deck plates have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 November 2019
Resolved
A vessel must have a ring life buoy that is approved in accordance with 46CFR160.050. Attending MI determined the grab line of the ring life buoy was deteriorated and coming apart.
46CFR180.70
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Life ring has been replaced with new one.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019
Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of passengers. Attending MI discovered the metal exhaust fan in the main passenger are was missing the cover/guard.
46CFR177.800(a)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Guards replaced on ventilation fan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2019
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load. Attending MI found the air intake for the main diesel engine was attached with a polypropylene line.
46 CFR 182.200(a)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Air intake properly mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2019
Resolved
A vessel of more than 65' must have at least one fire axe located in the operating station. Attending MI noted the fire axe was loosely stored in the pilot house, not in it's bracket.
*7 days to rectify*
46CFR181.600
Action required: 705 - Other - as specified
Due 28 November 2019
Resolved 25 November 2019
Resolution: Fire ax has been replaced.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 November 2019
Resolved
A vessel must comply with the applicable requirements for any radio installations as required by the Federal Communications Commission. Attending MI determined the VHF/DSC radio did not have the MMSI programmed in.
46CFR184.502
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: MMSI has been programmed in to VHF/DSC radio.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 November 2019
Resolved
Rails or equivalents must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Attending MI found several broken hand rails throughout the vessel.
*7 days to rectify*
46CFR177.900(a)
Action required: 705 - Other - as specified
Due 28 November 2019
Resolved 25 November 2019
Resolution: All broken handrails have been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2019
Resolved
The design and installation of exhaust systems must minimize risk or injury to personnel. Attending MI found lagging missing from exhaust piping.
46CFR182.430(a)
Action required: 30 - Ship detained
Due 25 November 2019
Resolved 26 November 2019
Resolution: Exhaust had new insulation wrapping it.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2019
Resolved
Front seal on port MDE leaking lube oil.
Action required: 30 - Ship detained
Due 25 November 2019
Resolved 26 November 2019
Resolution: Timing gear cover seal was replaced. Main seal was not leaking.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019
Resolved
This vessel is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.25-50
Action required: 30 - Ship detained
Resolved 26 November 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 10 May 2019
Resolution: verified shutdown and override.
Fire Fighting › Fire Pumps › Pressure
Issued 4 May 2018
Resolved
Fire pump gauge was fluctuating between 20psi and 50psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2018
Resolution: Vessel properly demonstrated proper operation of fire pump and fire pump guage.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 May 2018
Resolved
Engine room and generator space bilges have excessive oil creating an unsafe condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2018
Resolution: Vessel removed and cleaned bilge in both the engine room and generator space.
Fire Fighting › Combustible Materials › Insulation
Issued 4 May 2018
Resolved
Insulation was loose and removed in forepeak space and engine room. Vessel must replace insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 14 May 2018
Resolution: vessel replaced and repaired insulation throughout engine room and forepeak space.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 May 2017
Resolved
Provide new FCC Radiotelephony certificate (Vsl restricted to <1000ft offshore)
Action required: 705 - Other - as specified
Resolved 5 May 2017
Resolution: Cleared deficiency.
Construction/Loadline › Hull › Hull Plating
Issued 3 May 2017
Resolved
Repair crack in plate on port side of forepeak; drill stop, weld, and prove NDT. Repair cracked welds in same space.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Viewed proper welds.
Engineering › Fuel Oil Service System › Filter
Issued 3 May 2017
Resolved
Replace shatterproof bowl on stbd engine foreward fuel filter.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Cleared deficiency.
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 3 May 2017
Resolved
Properly install required ground detection for dual-voltage generator.
Due 31 May 2018
Resolved 11 June 2018
Resolution: Verified required ground detection was installed properly.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2017
Resolved
Provide corrected chart
Due 31 May 2017
Resolved 5 May 2017
Resolution: Cleared deficiency.