Records from 2002 to 2026. Most recent: inspection, 3 April 2026.
Inspection history · 88
3 April 2026
Plan Review "T" Boat · Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8341589
16 September 2025
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8235267
22 May 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8186833
6 May 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8121318
30 May 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7922521
27 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870369
19 October 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7810980
14 June 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7714755
28 June 2022
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7489387
3 February 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7390139
23 June 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7233535
22 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7012959
15 January 2020
Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6889721
11 December 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6872074
21 November 2019
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6859902
21 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6863077
16 July 2019
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751603
9 October 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6557242
24 May 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6427634
24 May 2018
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6428009
19 April 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394888
31 January 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6347340
27 July 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6222006
17 April 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6126460
13 February 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6087689
28 September 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6011262
30 March 2016
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5843935
21 January 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5800893
6 November 2015
Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5758817
17 August 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5732447
3 August 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5204893
28 October 2014
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5013359
24 August 2014
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4964804
24 August 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4966116
6 May 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4852501
7 May 2012
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4311810
6 May 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4330813
28 February 2012
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4255383
22 September 2011
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4151855
17 September 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4150175
15 October 2010
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3870986
6 February 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3685167
5 February 2010
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3682245
21 October 2008
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3353823
25 September 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3332414
8 September 2008
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3320776
16 August 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3300155
13 June 2008
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3235677
24 January 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3135655
8 November 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3095490
26 July 2007
MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3012277
29 March 2007
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2897355
23 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2895412
30 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2763966
23 August 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2781204
22 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2756599
8 June 2006
MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2731543
28 March 2006
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2611492
1 February 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2578887
1 February 2006
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2619562
4 January 2006
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2560207
2 December 2005
In-Service Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2549255
2 December 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2570001
11 November 2005
Damage Survey · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2532811
26 September 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2521827
5 August 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2452387
19 July 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2432423
13 July 2005
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2425344
12 July 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2444101
4 July 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2416234
5 May 2005
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2349795
29 March 2005
Examination of Repairs
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2322427
9 February 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2289102
8 February 2005
Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2288869
20 November 2004
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2244889
10 November 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2238867
28 October 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2199972
20 September 2004
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2200714
17 May 2004
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2070659
17 May 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2071286
13 January 2004
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1984015
29 December 2003
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1971160
1 August 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1864094
31 July 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1954413
22 July 2003
Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1853721
16 November 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1760017
16 August 2002
Deficiency Check · In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1665675
19 July 2002
Initial Certification · Construction Oversight
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1648825
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 May 2025
Resolved
A self priming, power driven fire pump must be installed on each vessel Of not more than 65 feet in length which is a ferry vessel. Fire pump was leaking during operational test. Repair or replace to the satisfaction of the attending marine inspector. 46 CFR 181.300(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: Operator made satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 May 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories Starboard main emergency fuel shutoff did not close when pulled. 46 CFR 182.455 (b((4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: Operator repaired fuel shut off valves.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 May 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Starboard fuel shut offs were not labeled properly. All fuel shutoffs on starboard side need to be clearly labeled to indicate which piece of machinery it supplies. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator appropriately marked fuel shut off valves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, other than a ferry, provided that: A positive shutoff valve is installed at the hull penetration. The valve for the aft port side engine room is seized and will not close. Repair or replace valve to the satisfaction of the attending marine inspector. 46 CFR 182.520(e)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 9 June 2025
Resolution: Marine Inspector attended the vessel and confirmed that the entire valve body had been replaced in kind, and the new valve could be easily actuated. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that:The pump discharge line is suitably supported. The inboard discharge line for the submersible pump in the starboard lazarette was loose. Ensure the line is properly supported to the satisfaction of the attending marine inspector. 46 CFR 182.520(e)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 9 June 2025
Resolution: Marine Inspector attended the vessel and confirmed that the discharge line had been replaced and clamped down tight to the discharge piping. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 May 2025
No resolution recorded
Controls and valves for operation of fixed gas fire extinguishing system must be located outside the space protected by the system. There is a pressure control switch inside the engine rooms. Relocate the pressure switch outside the protected space. Deficiency is due No Later Than 30NOV2025. 46 CFR 181.410(b)(1)
Action required: 705 - Other - as specified
Due 30 November 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2025
Resolved
The discharge ends of fuel tank vent pipes must terminate on the hull exterior as high above the waterline as practicable and remote from any hull openings, or they must terminate in U-bends as high above the weather deck as practicable and as far as practicable from openings into any enclosed spaces. The discharge end of both port and starboard fuel tank vent pipes end in an enclosed deck box with no ventilation. Submit modification plan to OCMI and affect repairs to the satisfaction of the attending marine inspector. 46 CFR 182.450(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator vented space to atmosphere.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Terminal board covering in port-side aft engine room has missing screw. Replace the screw to provide adequate enclosure of the terminal. 46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator made satisfactory repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. The vessel's shore tie connection cover is loose and has exposed wires. Repair to the satisfaction of the attending marine inspector. 46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator made satisfactory repair.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry three hand red flare distress signals, and three hand orange smoke distress signals. Vessel was missing 01 handheld red flare and 01 orange smoke distress signal. Equip vessel with appropriate number of distress signals. 46 CFR 180.68(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator provided vessel with appropriate number of distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
A vessel must carry one floating water light. Each ring life buoy with a floating water light must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the water light around the body of the ring life buoy. On a vessel carrying only one ring buoy, the floating water light must be attached to the lanyard with a corrosion-resistant clip. The floating water light line was connected to the grab line instead of the body of the ring life buoy and missing the clip. Equip vessel was required to the satisfaction of the attending marine inspector. 46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator provided corrosion resistent clip.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2025
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens. Backing plate of the port sidelight was not painted matte black. Paint backing plate matte black to the satisfaction of the attending marine inspector. 33 CFR 84.05(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator painted inboard side of vessel with matt black paint.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2025
Resolved
A vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. Ship’s whistle was not capable of producing a prolonged blast. Repair or replace to the satisfaction of the attending marine inspector. 33 CFR 83.33
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator repaired ships whistle
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel did not have an audible bilge high water level alarm at the operating station. Repair or replace audible alarms to the satisfaction of the attending marine inspector. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 12 May 2025
Resolution: Operator made repairs to high level alarms.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2023
Resolved
Carbon dioxide cylinders must be rejected for further service when they are dented, bulging, severely corroded, or otherwise in a weakened condition. Port and STBD engine room CO2 bottles are corroded. Replace Port and STBD engine room CO2 bottles.
46 CFR 147.65(a)(2)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2023
Resolved 23 October 2023
Resolution: Vessel provided doucmentation for CO2 service on 23OCT23. Port and STBD engine room CO2 bottles were changed out.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2023
Resolved
Fixed gas fire extinguishing system remote controls must be located in a break glass enclosure to preclude accidental discharge. Vessel was missing glass from port remote break glass station at the time of exam. Replace glass at port station.
46 CFR 181.410(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2023
Resolved 24 October 2023
Resolution: Vessel provided pictures of new break glass for port station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2023
Resolved
Except for a normally unoccupied space of less than 170 cubic meters (6000 cubic feet), release of an extinguishing agent into a space must require two distinct operations. STBD break glass station hammer was missing at time of exam. Replace STBD break glass station hammer.
46 CFR 181.410(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2023
Resolved 24 October 2023
Resolution: Vessel provided MI proof of STBD station hammer replacment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2023
Resolved
PROPULSION MACHINERY MUST BE SUITABLE IN TYPE AND DESIGN FOR PROPULSION REQUIREMENTS OF THE HULL IN WHICH IT IS INSTALLED AND CAPABLE OF OPERATING AT CONSTANT MARINE LOAD UNDER SUCH REQUIREMENTS WITHOUT EXCEEDING ITS DESIGNED LIMITATIONS. VESSEL'S STBD MAIN ENGINE COULD NOT BE STARTED DUE TO AN ISSUE WITH THE FUEL INJECTORS. MAKE REPAIRS, AND CONDUCT SEA TRIAL IN PRESENCE OF A MARINE INSPECTOR, PRIOR TO PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2023
Resolved 19 October 2023
Resolution: Vessel completed repairs on STB Main Engine. Vessel replaced Cylinder head,injectors and turbo. Vessel performed sea trial with inspectors onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2020
Resolved
Each connection to a conductor must be within an enclosure. All bilge pumps/ high level alarm connections are not within an enclosure. Place all connections within an enclosure
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 10 August 2020
Resolution: Received satisfactory pictures attesting to proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 December 2019
Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. Vessel operator reported a loss of steering. Prior to carrying passengers: 1)Determine the cause of the loss of steering, 2) Conduct satisfactory sea trials.46 CFR 182.610
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2019
Resolved 11 December 2019
Resolution: Attended vessel and witnessed satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2019
Resolved
Hawser line fouled prop
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2019
Resolution: Conducted satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 October 2018
Resolved
Ground for both port and starboard alternators on the main generators are improperly installed. Install ground from alternators to negative terminal on battery as per manufacterer's recommendation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 30 November 2018
Resolution: Ground wire from alternator to battery properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 October 2018
Resolved
Operator failed to provide proof of operation of ground detection. Provide proof of proper operation of ground detection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 30 November 2018
Resolution: Verified proper operation of ground detection system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 October 2018
Resolved
Port main generator is missing machinery guard. Install machinery guard for the protection of equipment and personnel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 30 November 2018
Resolution: Witnessed newly installed machinery guard on port main generator.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 24 May 2018
Resolved
vessel's port shaft dripless packing coupling slid forward causing water to enter the vessel. Vessel must repair and prove proper operation to CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2018
Resolution: vessel repaired and proved proper operation to CG inspector.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 24 May 2018
Resolved
vessel's bilge alarm has no audible alarm. Vessel must fix bilge alarm and prove proper operation to CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2018
Resolution: vessel repaired bilge alarm and proved operation to CG inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 27 July 2017
Resolved
Provide updated marine charts.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 3 August 2017
Resolution: Received email documentation of photo of new chart.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 July 2017
Resolved
Provide (03) adult lifejackets. Passenger count restricted to 98 (101 total persons)
Action required: 705 - Other - as specified
Resolved 3 August 2017
Resolution: Recieved photo documentation of (03) new type I PFD's.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 28 September 2016
Resolved
The electrical controls for the port main engine will not engage in reverse.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2016
Resolved 30 September 2016
Resolution: Verified control is working properly again.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 21 January 2016
Resolved
KB01 - Ground detection not installed. Provide ground detection installation proposal.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 February 2016
Resolved 30 March 2016
Resolution: Received repair proposal from [name withheld], indicating the parts for repair have been ordered and a plan is in place to install ground detection meter.
Construction/Loadline › Hull › Hull Plating
Issued 24 August 2014
Resolved
Vessel has a 5" crack on the starboard side just forward of the collision bulkhead cause by a submerge floating object.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2014
Construction/Loadline › Hull › Hull Plating
Issued 24 August 2014
Resolved
Crop damage on STBD side to good metal. For attending [name withheld] to include materials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2014
Resolution: Conducted NDT, all sat.
Construction/Loadline › Structures › Superstructure
Issued 7 May 2012
Resolved
Crop and renew damaged port bow bulwark.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 May 2012
Resolved
Repair port bow cracked handrail stantion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2012
Fire Fighting › Ventilation Systems › Operating Controls
Issued 7 May 2012
Resolved
Repair damaged fire dampener screen. Prove proper operation of fire dampeners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2012
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 28 February 2012
Resolved
PF01 - Makes propellers available for inspection. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 8 March 2012
Resolution: Received pictures attesting to new installation of propellers.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 February 2012
Resolved
PF02 - Replace port side cutlass bearing. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 8 March 2012
Resolution: Received pictures attesting to new installation of cutlass bearing.
Engineering › Steering Gear System › Rudder Stock
Issued 28 February 2012
Resolved
Replace port and starboard side rudder collar as discussed and make available for inspection. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 8 March 2012
Resolution: Received pictures attending to to new installation of rudder collars.
Engineering › Sea-water System (primary cooling) › Pump
Issued 5 February 2010
Resolved
The vsl reported a loss of the port eng while transitting to Pier 11 in Manhattan on 05FEB10. Accordingly, the vsl must assess what happened to the port eng and make appropriate repairs. The repairs and sea trial must be to the satisfaction of the [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2010
Construction/Loadline › Hull › Hull Plating
Issued 21 October 2008
Resolved
V/W forward starboard side stem as indicated by marine inspector.
Action required: 705 - Other - as specified
Resolved 30 October 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2007
Resolved
Properly enclose wire splice for starboard engine room blower in an enclosure in accordance with 46 CFR 183.340(g).
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 13 September 2007
Resolution: Properly enclosed wire splice within a mounted junction box.
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2007
Resolved
Due to vessel hitting submerged object, conduct dive survey of vessel or drydock and make available for USCG inspection, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Resolution: Attended vessel at drydock, issued 2 requirements.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 29 March 2007
Resolved
Repair/replace port side strut.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Resolution: Port strut repaired.
Engineering › Steering Gear System › Rudder
Issued 29 March 2007
Resolved
Repair/replace port side rudder.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Resolution: Port rudder repaired.
Personnel › Training › Fire Fighting Basic
Issued 8 June 2006
Resolved
Conduct and log MOB drill to the sat of the attending CG MI.
Action required: 705 - Other - as specified
Resolved 23 August 2006
Navigation › Piloting/Steering › Marine Charts
Issued 8 June 2006
Resolved
Provide updated charts for the area to be transited.
Due 1 August 2006
Resolved 23 August 2006
Construction/Loadline › Hull › Hull Plating
Issued 1 February 2006
Resolved
Ascertain the source of leak that resulted in 1.5 inches of water in the stbd bow void space. Vsl is restricted from carrying passengers until cause is identified, and permanent repairs completed to the sat of the attending CG MI.
Action required: 705 - Other - as specified
Resolved 8 March 2006
Resolution: Vsl rep determined that source of water ingres was due to no check valve installed in the bilge pump dischage line. Check valves were installed on 3/8/2006.
Stability › Unintentional Flooding › General
Issued 4 December 2005
Resolved
Determine source of water in port forepeak and submit repair proposal to make permanent and proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2006
Resolution: Crack found in hull and was repaired by Derecktor''''s shipyard in Bridgeport, CT. Work was inspected by CG from Long Island Sound. Observed and cleared once vessel returned to homepot and SECNY inspection zone.
Stability › Unintentional Flooding › General
Issued 4 December 2005
Resolved
Determine source of water in stbd forepeak and submit repair proposal to make permanent and proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2006
Resolution: Crack found in hull and was repaired by Derecktor''s shipyard in Bridgeport, CT. Work was inspected by CG from Long Island Sound. Observed and cleared once vessel returned to homepot and SECNY inspection zone.
Construction/Loadline › Structures › Machinery Space Opening
Issued 4 December 2005
Resolved
Make permanent repairs to drain hole drilled in port engine hatch cover combing.
Due 4 January 2006
Resolved 17 January 2006
Resolution: Completed.
Stability › Unintentional Flooding › General
Issued 4 December 2005
Resolved
Properly repair leaking rudder post in port laz.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2005
Resolution: Rudder post packing and bearings replaced at Tottenville shipyard.
Stability › Unintentional Flooding › General
Issued 4 December 2005
Resolved
Properly repair leaking rudder post in stbd laz.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2005
Resolution: Rudder post packing and bearings replaced at Tottenville shipyard.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 December 2005
Resolved
Clean E/R bilge port and stbd side.
Due 4 January 2006
Resolved 20 January 2006
Resolution: Oil removed from bilges.
Stability › Unintentional Flooding › General
Issued 2 December 2005
Resolved
Determine source of water in laz and submit repair proposal to make permanent and proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2005
Resolution: Rudder post packing and bearings replaced at Tottenville shipyard.
Stability › Watertight Integrity › Coaming
Issued 11 November 2005
Resolved
Replace deckseal on hatch to S/S laz.
Condition: Unknown
Due 17 November 2005
Resolved 17 November 2005
Stability › Watertight Integrity › General
Issued 11 November 2005
Resolved
Replace hatch cover securing device on S/S laz
Condition: Unknown
Due 17 November 2005
Resolved 17 November 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 November 2005
Resolved
Terminate dead end wires on speaker boxes topside.
Condition: Unknown
Due 17 November 2005
Resolved 17 November 2005
Engineering › Bilge Water Management System › Piping
Issued 11 November 2005
Resolved
Replace metal supports for flexible bilge line in S/S and P/S laz
Condition: Unknown
Due 17 November 2005
Resolved 18 November 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 November 2005
Resolved
Remove and properly dispose of oil in S/S engine room bilge
Condition: Unknown
Due 17 November 2005
Resolved 17 November 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 November 2005
Resolved
Make repairs to P/S engine room hatch.
Condition: Unknown
Due 17 November 2005
Resolved 17 November 2005
Stability › Watertight Integrity › General
Issued 11 November 2005
Resolved
Make P/S engine room aft bulkhead watertight.
Condition: Unknown
Due 17 November 2005
Resolved 17 November 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 11 November 2005
Resolved
Properly install lagging on turbines on both MDE's.
Condition: Unknown
Due 17 November 2005
Resolved 17 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 11 November 2005
Resolved
Submit repair proposal for crack in P/S forepeak as marked in vicinity of fwd bulkhead.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2005
Fire Fighting › Fire Pumps › Capacity
Issued 11 November 2005
Resolved
Prove proper operation of fire pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2005
Fire Fighting › Fire Hoses › Condition
Issued 11 November 2005
Resolved
Provide validation of all fire hoses for vsl. (hydrotest)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 November 2005
Resolved
Develop and implement a Preventive Maintenance System.
Condition: Improper/Lack of Maintenance
Due 14 December 2005
Resolved 14 December 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 November 2005
Resolved
Prove proper operation of magnetic compass light.
Action required: 705 - Other - as specified
Due 25 November 2005
Resolved 25 November 2005
Communications › Audible Communications › SPD (Other)
Issued 11 November 2005
Resolved
Prove proper operation of installed public address system.
Action required: 705 - Other - as specified
Due 25 November 2005
Resolved 25 November 2005
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 13 July 2005
Resolved
Determine nature of MDEs oil spray and submit casualty analysis report to CG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2005
Resolved 27 July 2005
Resolution: Examined crack in oil cooling line, line renewed with same.
RJG
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 12 July 2005
Resolved
Conduct repairs to MDEs to CG satisfaction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2005
Resolved 27 July 2005
Resolution: Observed renewed oil cooling line installed.
RJG
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 12 July 2005
Resolved
Conduct sea trails to CG satisfaction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2005
Resolved 27 July 2005
Resolution: Conducted static engine run dockside. Brought S/S MDE up to operating temps. Observed oil cooling line, checked for leaks. None observed - all sat.
RJG
Construction/Loadline › Hull › Hull Plating
Issued 8 February 2005
Resolved
Make permanent repairs to the port strut.
Due 15 April 2005
Resolved 26 May 2005
Resolution: Repairs made to port strut.
Construction/Loadline › Structures › Superstructure
Issued 20 November 2004
Resolved
Submit permanent repair proposal to the Officer in Charge, Marine Inspection (OCMI), regarding the deckhouse crack and puncture rec'd on 20 NOV.
Due 15 December 2004
Resolved 3 December 2004
Resolution: Rcvd an e-mail from [name withheld] with a proposal to crop an 18" x 18" section of the damage plate IVO of the crack at the time of the next drydock. The temporary repair is to use epoxy to keep water out of the interior of the deckhouse.
Construction/Loadline › Structures › Superstructure
Issued 20 November 2004
Resolved
Upon approval of NY01, make permanent repairs to vessel accordance with repair proposal (within a timeframe acceptable to the OCMI).
Due 31 March 2005
Resolved 26 May 2005
Resolution: Repairs made.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 October 2004
Resolved
COI was not posted so that all pages are visible to passengers.
Condition: Improper/Lack of Maintenance
Due 28 October 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Documentation › Certificates/Documents › Stability Letter
Issued 28 October 2004
Resolved
Stability letter not posted at the control station.
Condition: Improper/Lack of Maintenance
Due 28 October 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Navigation › Piloting/Steering › Marine Charts
Issued 28 October 2004
Resolved
Updated charts not onboard or system not in place to track changes (Local Notice to Mariners).
Condition: Improper/Lack of Maintenance
Due 28 October 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Documentation › Certificates/Documents › FCC SSL
Issued 28 October 2004
Resolved
Call sign on FCC Station License and FCC Safety Certificate was different.
Due 30 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Personnel › Training › Fire Fighting Basic
Issued 28 October 2004
Resolved
Vessel crew unknowledgeable in proper techniques for engaging both fire pumps and aligning all needed valves.
Condition: Improper/Lack of Maintenance
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Construction/Loadline › Structures › Superstructure
Issued 28 October 2004
Resolved
V/W cap plate on transom in two places A/M.
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Construction/Loadline › Structures › Superstructure
Issued 28 October 2004
Resolved
V/W Fixed CO2 bracket in Stbd lazerett.
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Construction/Loadline › Structures › Superstructure
Issued 28 October 2004
Resolved
V/W under deck long in void #2.
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Construction/Loadline › Structures › Superstructure
Issued 28 October 2004
Resolved
V/W railing in bow area in several locations.
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Construction/Loadline › Structures › Superstructure
Issued 28 October 2004
Resolved
V/W port bow in void #1 A/M.
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 28 October 2004
Resolved
No proof of required 60 minute annual Drug & Alcohol training for supervisors.
Condition: Improper/Lack of Maintenance
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item was cleared via e-mail from [name withheld] attesting to repairs/modifications/necessary action being completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 20 September 2004
Resolved
Metal found in stbd engine oil pan. Vsl rep stated stbd MDE would be replaced in kind. Issued CG-835 for same.
Condition: Unknown
Due 23 September 2004
Resolved 23 September 2004
Resolution: Stbd MDE replaced in kind.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 20 September 2004
Resolved
Conduct sea trial/operational test of newly installed stbd MDE.
Condition: Unknown
Due 29 September 2004
Resolved 29 September 2004
Resolution: Sea trials conducted.
Construction/Loadline › Hull
Issued 17 May 2004
Resolved
Make permanent repair proposal for stbd (outboard) side shell in lazerette and #1 frame fwd of transome to USCG. LEGACY COMPONENT DESC: Hull Plating
Due 17 May 2004
Resolved 18 May 2004
Resolution: Approved repair proposal.
Construction/Loadline › Hull
Issued 17 May 2004
Resolved
Make permanent repairs, per approved plan in NY01, to the satisfaction of an attending USCG Marine Inspector. LEGACY COMPONENT DESC: Hull Plating
Due 17 May 2004
Resolved 26 May 2004
Resolution: Repairs completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 September 2003
Resolved
Make proper repairs to the fix fire fighting system to cause MDE's to shutdown with system in activated. LEGACY COMPONENT DESC: Operating Controls
Due 2 October 2003
Resolved 2 October 2003
Stability › Watertight Integrity
Issued 31 July 2003
Resolved
Draft repair proposal for cracks found in port and starboard stern and submit to OCMI for approval prior to making any repairs. Vsl restricted from carrying passengers. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 4 August 2003
Engineering › Bilge Water Management System
Issued 22 July 2003
Resolved
Prove proper operation of Bile high level alarm system. Until deficiency is cleared must make 15 min. rounds of all void spaces when conducting commercial ops.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2003
Resolved 13 August 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 July 2003
Resolved
Prove satisfactory test of portable extinguishers and fixed fire extinguishing systems annual servicing. Vsl restricted from conducting commercial ops until cleared. Service due date was June 2003
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Vsl rep faxed a copy of the certificate, completed by ALL FIRE SYSTEMS, INC.
Engineering
Issued 22 July 2003
Resolved
Make permanent repairs to lagging on dry type exhaust system, port engine. LEGACY COMPONENT DESC: Lagging
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 13 August 2003
Electrical
Issued 22 July 2003
Resolved
Make permanent repairs to shipboard end shore tie connection. LEGACY COMPONENT DESC: Shore tie connection
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 13 August 2003
Engineering › Bilge Water Management System
Issued 23 August 2002
Resolved
Provide installed hard piped bilge dewatering system iaw 46 CFR 182.510 & 182.520. Vsl is restricted to a Rivers Route, and must have an additional portable electrical sub pump onboard until this requirement is completed. Altered 9/6 by [name withheld] to remove the 49 pax restriction. LEGACY COMPONENT DESC: Piping
Due 16 September 2002
Resolved 29 August 2002
Resolution: IAW MSC LTR E1-0202466a DTD 29 AUG 02, VESSEL GRANTED EQUIVALENCY FOR ELECTRICAL SUB PUMPS INSTEAD OF FIXED BILGE MANIFOLD SYSTEM. A PORTABLE ELECTRIC BILGE PUMP OF AT LEAST 25 GPM CAPABLE OF DEWATERING ANY SPACE ON THE VESSEL MUST BE PROVIDED.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 August 2002
Resolved
Install automatic shutdowns for main engines and generator upon actuation of the CO2 fixed fire fighting systems. Train crews to manually stop this equipment prior to actuating the CO2 systems until this requirement is complied with. LEGACY COMPONENT DESC: Operating Controls
Due 23 September 2002
Resolved 28 October 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 23 August 2002
Resolved
In accordance with MSC plan approval letter, make fuel fill and vent pipes schedule 80 aluminum. LEGACY COMPONENT DESC: Piping
Due 30 September 2002
Resolved 18 September 2003
Resolution: MSC ltr dtd 18Sep02/E1-02003158 - Sched 40 alum pipe for fill and vent lines acceptable so long as they do no conduct combustible fluids under normal operating conditions.
Fire Fighting › Fire Pumps
Issued 23 August 2002
Resolved
In accordance with MSC plan approval letter, demonstrate that fire pump has 50 gpm capacity and 60 psi pressure. LEGACY COMPONENT DESC: Pressure
Due 9 September 2002
Resolved 10 September 2002
Engineering › Bilge Water Management System
Issued 23 August 2002
Resolved
Attach line to portable electric submersible bilge pump required by MSC ltr E1-0202466a dtd 29 Aug 02. LEGACY COMPONENT DESC: Pump
Due 9 October 2002
Resolved 30 September 2003
Engineering › Bilge Water Management System
Issued 23 August 2002
Resolved
Prove proper operation (self-priming) of bilge pumps. LEGACY COMPONENT DESC: Pump
Due 9 October 2002
Resolved 30 September 2003
Electrical › Electric Supply System (service)
Issued 19 July 2002
Resolved
Lable the 24VDC galley panel with the numbers for breaker identification. LEGACY COMPONENT DESC: Overcurrent Device
Due 30 August 2002
Resolved 10 September 2002
Construction/Loadline › Structures
Issued 19 July 2002
Resolved
Weld the deck plate to the side shell IWO the engine room aft access. LEGACY COMPONENT DESC: Machinery Space Opening
Due 30 August 2002
Resolved 10 September 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 19 July 2002
Resolved
Provide additional PFD's on the upper deck to bring the total to 30. LEGACY COMPONENT DESC: Quantity
Due 30 August 2002
Resolved 10 September 2002
Lifesaving › Lifejacket/PFD (Type IV)
Issued 19 July 2002
Resolved
Provide 60 ft of buoyant line and 3 ft lanyard for the water light. LEGACY COMPONENT DESC: Condition
Due 30 August 2002
Resolved 10 September 2002
Deck/Cargo › Mooring/Anchoring
Issued 19 July 2002
Resolved
Attach the anchor line to the area around the starboard fore peak hatch for easy access. LEGACY COMPONENT DESC: Anchor Cable
Due 30 August 2002
Resolved 10 September 2002
Navigation › Piloting/Steering
Issued 19 July 2002
Resolved
Provide CG Light List LEGACY COMPONENT DESC: Coast Guard Light List
Due 30 August 2002
Resolved 16 August 2002
Resolution: Viewed by [name withheld].
Construction/Loadline › Penetrations
Issued 19 July 2002
Resolved
Provide hold back latches to prevent the hatch from falling. LEGACY COMPONENT DESC: Engine room aft hatches
Due 30 August 2002
Resolved 10 September 2002
Engineering › Shafting/Propeller Arrangements
Issued 19 July 2002
Resolved
Tighten the shaft packing IAW manufacturing specs. LEGACY COMPONENT DESC: Coupling
Due 30 August 2002
Resolved 10 September 2002
Navigation › Piloting/Steering
Issued 19 July 2002
Resolved
Adjust stbd rudder limit switch to allow full rudder movement. LEGACY COMPONENT DESC: Rudder limit switch
Due 30 August 2002
Resolved 10 September 2002
Stability
Issued 19 July 2002
Resolved
Provide approved stability letter. Vessel is not to carry passenger until this requirment is met. LEGACY COMPONENT DESC: Stability letter
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2002
Resolved 5 August 2002
Resolution: MSC sent stability letter via fax.
Engineering › Bilge Water Management System
Issued 19 July 2002
Resolved
Provide check valve between the strainer and the ball valve. LEGACY COMPONENT DESC: Valve
Due 30 August 2002
Resolved 28 October 2003
Construction/Loadline › Structures
Issued 19 July 2002
Resolved
Provide approved plans IAW 46 CFR 177.202. LEGACY COMPONENT DESC: Plans
Due 30 August 2002
Resolved 10 September 2002
Personnel › Training
Issued 19 July 2002
Resolved
Perform satisfactory fire and MOB drills for attending Marine Inspector. LEGACY COMPONENT DESC: Familiarization Training
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2002
Resolved 16 August 2002
Resolution: Drills observed by [name withheld] - sat.