Inspection history · 22
27 April 2026
Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8356414
11 March 2026
Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319937
4 September 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8227466
8 July 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8178871
15 July 2024
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7958435
8 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7861778
13 July 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7741477
8 June 2022
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7471864
1 March 2022
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7403659
14 April 2021
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175385
13 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7007588
2 March 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6918603
8 July 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6741332
8 February 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6622263
12 December 2018
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601037
14 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6580411
9 July 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472615
16 March 2018
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6373204
1 March 2018
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392362
12 July 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6207109
22 April 2016
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5859993
1 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5824511
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 April 2026
Resolved
Vessel to which this subchapter applies may not be operated without having a valid U.S. Coast Guard Certificate of Inspection. Subject vessel's COI expired. Rectify prior to pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2026
Resolution: COI inspection complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2026
Resolved
Piping used in vital systems must be composed of ferrous materials. Mis observed bilge piping at suction strainer were made of plastic materialin both P/S #3 voids & lazarette compartments. Replace w/ metal strainers w/in 30 days. 46 cfr 182.710(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2026
Resolution: All bilge suction plastic strainers have been replaced with metal strainers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2026
Resolved
The construction & arrangements of a vessel must allow the safe operation of the vessel ... in case of a sudden casualty. MI's observed port lazarette bilge suction inoperable due to leak in bilge piping system. Rectify to satisfaction of OCMI w/in 30 days.
46 cfr 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2026
Resolution: Bilge pipe cropped and renewed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 April 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate & up-to-date charts of large enough scale to make navigation possible. MI's observed outdated charts and publications. Rectify w/in 14 days. 46 cfr 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2026
Resolution: Navigation charts, Coast Pilot, and publications updated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 September 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel was taking on water in the STBD side raw water intake for their HVAC system. Submit repair proposal for approval to the local OCMI for approval prior to making repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2025
Resolution: Completed in person def check and tested bilge pumping arrangement. Test sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 July 2025
Resolved
Piping must comply with subpart G, part 182 of this chapter. MIs found a leak on the firemain piping above a breaker panel in the stbd engine room, aft end. Implement permanent repairs within 7 days.
Action required: 705 - Other - as specified
Due 15 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 July 2025
Resolved
On vessels carrying >49 passengers, the minimum capacity of the fire pump must be 50 GPM at 60 PSI/ Max pressure reached was 50 PSI during inspection. Take steps to increase pressure within 7 days.
Action required: 705 - Other - as specified
Due 15 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 July 2025
Resolved
An exposed hazard such as gears or rotating machinery, must be protected with a guard. MIs found 3 pieces of rotating machinery unguarded: Forward Engine End belt (both Port and STBD) and diaphragm type bilge pump. Provide guards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2025
Resolved 30 July 2025
Resolution: Guards provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2025
Resolved
A vessel must have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, & MOB conditions. MIs found no such instructions posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 July 2025
Resolved
A vessel must carry a first aid kit that meets the requirements in 46 CFR 199.175(b)(10). MIs found expired medicines in the first aid kit. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2025
Resolved
An adult life jacket must be provided for each person carried. MIs condemned 13 lifejackets. Replace prior to carrying >54 persons.
Action required: 705 - Other - as specified
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2024
Resolved
Each life jacket must be marked with Type 1 retroreflective material approved with 46 CFR 164.018... several lifejackets identified with torn retroreflective material. ensure all life jackets have appropriate retro reflective material.
46 CFR 185.604(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2024
Resolution: Vesel Provided video evidence of both port and starboard exhaust dampeners closing.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 July 2024
Resolved
Provision must be made for closing all supply duct cowls or scops and exhaust duct dscharge openings for a protected space by fixed gas extinguishing system. Port exhaust dampener was not closing. STBD exhaust dampener did not fully close. Repair both exhaust dampeners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2024
Resolution: Operator provided video evidence of proper automatic operation of the fire dampener louvers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 June 2022
Resolved
Two flexible hoses in port lazarette were single hose clamped. Add additional hose clamp to make double hose clamped.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 15 June 2022
Resolution: Recieved Satisfactory photographs of rectification. See deficiencies documents tab for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2022
Resolved
Four small exposed wires identified under wheelhouse. Cover wires to reduce hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 15 June 2022
Resolution: Recieved Satisfactory photographs of rectification. See deficiencies documents tab for details.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2021
Resolved
Floating water light must be approved IAW 161.010 in sub chapter Q. Batteries in water light not IAW manufacturer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 27 April 2021
Resolution: Received photos showing new batteries approved by manufacturer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2021
Resolved
Each life jacket must be marked with type 1 retro reflective material IAW 46CFR164.018. Reflective material on life jackets is worn and peeling off.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
Resolution: Received photos of new SOLS tape installed on lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 November 2018
Resolved
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 July 2018
Resolved
Vessel must have approved fire detection and alarm system in a space containing propulsion machinery. During inspection it was noted that the vessel did not have installed fire detection and alarm system. Vessel must install approved system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2018
Resolution: Attending Marine INspector verified proper installation of detection devices.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 July 2018
Resolved
Vessel must have a device to automatically shut down the engines when the fixed fire extinguishing system is activated. During inspection it was noted that vessel did not have a device to automatically shut down the engine. Vessel must provide means to automatically shut down engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 July 2018
Resolution: Attending Marine inspector witnessed proper operation of the pressure switches which then automatically shut down the engines.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 9 July 2018
Resolved
Emergency instructions must be mounted at the operating station. During inspection it was noted that the vessel did not have emergency instructions. Vessel must provide written emergency instructions and post at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 10 July 2018
Resolution: Attending Marine INspector verified presence of emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 July 2018
Resolved
Vessel must be equipped with a gauge at the fire pump outlet to read psi. During inspection it was noted that pressure gauge was inoperable. Vessel must provide an
operable pressure guage for the fire pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 10 July 2018
Resolution: Vessel received a new gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2018
Resolved
Vessel to provide copies of submitted plans for re-power to this office.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 11 July 2018
Resolution: Sector New York received copies via email.