HEAVENS GATE

Built
2003
Last inspected
27 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2613
638239
Flag
UNITED STATES
Maury page id
psix-638239

Documentation record

Registered dimensions (L × B × D)53.3 ft × 18.7 ft × 8.5 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDERECKTOR SHIPYARDS CONN, LLC · BRIDGEPORT, CT, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portBAYONNE, NJ
Endorsements, as the file codes themcw_un
DocumentationValid · issued 7 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

27 April 2026 Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8356414
11 March 2026 Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319937
4 September 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8227466
8 July 2025 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8178871
15 July 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7958435
8 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7861778
13 July 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7741477
8 June 2022 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7471864
1 March 2022 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7403659
14 April 2021 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175385
13 July 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7007588
2 March 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6918603
8 July 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6741332
8 February 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6622263
12 December 2018 Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601037
14 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6580411
9 July 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472615
16 March 2018 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6373204
1 March 2018 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392362
12 July 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6207109
22 April 2016 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5859993
1 March 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5824511

Deficiency record · 23

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 April 2026 Resolved
Vessel to which this subchapter applies may not be operated without having a valid U.S. Coast Guard Certificate of Inspection. Subject vessel's COI expired. Rectify prior to pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2026
Resolution: COI inspection complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2026 Resolved
Piping used in vital systems must be composed of ferrous materials. Mis observed bilge piping at suction strainer were made of plastic materialin both P/S #3 voids & lazarette compartments. Replace w/ metal strainers w/in 30 days. 46 cfr 182.710(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2026
Resolution: All bilge suction plastic strainers have been replaced with metal strainers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2026 Resolved
The construction & arrangements of a vessel must allow the safe operation of the vessel ... in case of a sudden casualty. MI's observed port lazarette bilge suction inoperable due to leak in bilge piping system. Rectify to satisfaction of OCMI w/in 30 days. 46 cfr 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2026
Resolution: Bilge pipe cropped and renewed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 April 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate & up-to-date charts of large enough scale to make navigation possible. MI's observed outdated charts and publications. Rectify w/in 14 days. 46 cfr 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2026
Resolution: Navigation charts, Coast Pilot, and publications updated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 September 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel was taking on water in the STBD side raw water intake for their HVAC system. Submit repair proposal for approval to the local OCMI for approval prior to making repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2025
Resolution: Completed in person def check and tested bilge pumping arrangement. Test sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 July 2025 Resolved
Piping must comply with subpart G, part 182 of this chapter. MIs found a leak on the firemain piping above a breaker panel in the stbd engine room, aft end. Implement permanent repairs within 7 days.
Action required: 705 - Other - as specified
Due 15 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 July 2025 Resolved
On vessels carrying >49 passengers, the minimum capacity of the fire pump must be 50 GPM at 60 PSI/ Max pressure reached was 50 PSI during inspection. Take steps to increase pressure within 7 days.
Action required: 705 - Other - as specified
Due 15 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 July 2025 Resolved
An exposed hazard such as gears or rotating machinery, must be protected with a guard. MIs found 3 pieces of rotating machinery unguarded: Forward Engine End belt (both Port and STBD) and diaphragm type bilge pump. Provide guards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2025
Resolved 30 July 2025
Resolution: Guards provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2025 Resolved
A vessel must have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, & MOB conditions. MIs found no such instructions posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 July 2025 Resolved
A vessel must carry a first aid kit that meets the requirements in 46 CFR 199.175(b)(10). MIs found expired medicines in the first aid kit. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2025 Resolved
An adult life jacket must be provided for each person carried. MIs condemned 13 lifejackets. Replace prior to carrying >54 persons.
Action required: 705 - Other - as specified
Resolved 17 July 2025
Resolution: Visited the vessel and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2024 Resolved
Each life jacket must be marked with Type 1 retroreflective material approved with 46 CFR 164.018... several lifejackets identified with torn retroreflective material. ensure all life jackets have appropriate retro reflective material. 46 CFR 185.604(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2024
Resolution: Vesel Provided video evidence of both port and starboard exhaust dampeners closing.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 July 2024 Resolved
Provision must be made for closing all supply duct cowls or scops and exhaust duct dscharge openings for a protected space by fixed gas extinguishing system. Port exhaust dampener was not closing. STBD exhaust dampener did not fully close. Repair both exhaust dampeners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2024
Resolution: Operator provided video evidence of proper automatic operation of the fire dampener louvers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 June 2022 Resolved
Two flexible hoses in port lazarette were single hose clamped. Add additional hose clamp to make double hose clamped.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 15 June 2022
Resolution: Recieved Satisfactory photographs of rectification. See deficiencies documents tab for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2022 Resolved
Four small exposed wires identified under wheelhouse. Cover wires to reduce hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 15 June 2022
Resolution: Recieved Satisfactory photographs of rectification. See deficiencies documents tab for details.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2021 Resolved
Floating water light must be approved IAW 161.010 in sub chapter Q. Batteries in water light not IAW manufacturer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 27 April 2021
Resolution: Received photos showing new batteries approved by manufacturer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2021 Resolved
Each life jacket must be marked with type 1 retro reflective material IAW 46CFR164.018. Reflective material on life jackets is worn and peeling off.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
Resolution: Received photos of new SOLS tape installed on lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 November 2018 Resolved
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 July 2018 Resolved
Vessel must have approved fire detection and alarm system in a space containing propulsion machinery. During inspection it was noted that the vessel did not have installed fire detection and alarm system. Vessel must install approved system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2018
Resolution: Attending Marine INspector verified proper installation of detection devices.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 July 2018 Resolved
Vessel must have a device to automatically shut down the engines when the fixed fire extinguishing system is activated. During inspection it was noted that vessel did not have a device to automatically shut down the engine. Vessel must provide means to automatically shut down engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 July 2018
Resolution: Attending Marine inspector witnessed proper operation of the pressure switches which then automatically shut down the engines.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 9 July 2018 Resolved
Emergency instructions must be mounted at the operating station. During inspection it was noted that the vessel did not have emergency instructions. Vessel must provide written emergency instructions and post at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 10 July 2018
Resolution: Attending Marine INspector verified presence of emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 July 2018 Resolved
Vessel must be equipped with a gauge at the fire pump outlet to read psi. During inspection it was noted that pressure gauge was inoperable. Vessel must provide an operable pressure guage for the fire pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 10 July 2018
Resolution: Vessel received a new gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2018 Resolved
Vessel to provide copies of submitted plans for re-power to this office.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 11 July 2018
Resolution: Sector New York received copies via email.