Records from 2002 to 2026. Most recent: inspection, 22 April 2026.
Inspection history · 25
22 April 2026
Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8343992
17 July 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8160895
4 March 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8087981
7 November 2024
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8031962
31 October 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8027519
21 March 2024
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7879244
15 March 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609108
25 October 2022
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7580651
15 March 2022
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7412998
29 March 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7164940
24 March 2021
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7161584
2 November 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7087203
18 March 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7059224
19 March 2019
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645463
25 October 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6567462
27 July 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6222735
13 April 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123515
11 April 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6122186
3 April 2017
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6116433
6 March 2017
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6099840
6 March 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6099930
18 July 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5944697
14 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5906845
14 March 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5832955
7 March 2016
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5831429
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 July 2025
Resolved
"An inspection for renewal of a certificate of inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations." Vessel does not have hired crew yet. Obtain a properly licensed crew.
46 CFR 176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2026
Resolution: Vessel has a licensed crew.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2024
Resolved
"A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years." Vessel did not complete its next DDX/ISE by its due date of 31OCT2024. Complete a credit DDX/ISE.
46 CFR 176.600(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 January 2025
Resolution: dry dock completed
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 21 March 2024
Resolved
Vessel's crew did not log abandon ship and man overboard drills for the last three months. Vessel crew did not complete man overboard drill. "Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2024
Resolution: Conducted man overboard drill in presence of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2024
Resolved
Starboard main engine loss of power failsafe did not operate under loss of power. "A propulsion engine control system, including pilothouse control, must be designed so that a loss of power to the control system does not result in an increase in shaft speed or propeller pitch."
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2024
Resolution: Vessel demonstrated the capability to be clutched in and simulated a loss of power failsafe test. The engine declutched and dropped to neutral.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 March 2024
Resolved
Printed navigation and electronic charts were not up to date . "As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (a) Citation46 CFR 184.420(a) (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority."
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 April 2024
Resolution: Updated charts with corrections were presented.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 October 2022
Resolved
Identified multiple pits and cracks in Port Side Rudder. STBD Side rudder had a cracked plastic spacer. Provide repair plan and make proper repairs as specified.
Action required: 705 - Other - as specified
Due 25 October 2022
Resolved 28 October 2022
Resolution: Visually inspected rudder repaired and plastic spacer replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 October 2022
Resolved
Incomplete weld found in port side aft compartment bulkhead.
Action required: 705 - Other - as specified
Due 25 October 2022
Resolved 28 October 2022
Resolution: Weld complete.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 March 2021
Resolved
Port side engineroom forward damper does not close fully when activated. Adjust damper to close fully when released.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2021
Resolution: Attending Marine Inspector verified satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2021
Resolved
Multiple bilge pumps were inoperable. Repair bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2021
Resolution: Attending Marine Inspector verified satisfactory repair.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 24 March 2021
Resolved
Carbon monoxide was detected in starboard void #3. Provide causal analysis and technical report identifying cause of carbon monoxide and attesting that repairs/rectification have been completed. Gas free the space and prepare for reinspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2021
Resolution: Attending Marine Inspector verified satisfactory repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 March 2021
Resolved
COI was posted in pilothouse. Post all pages of COI so they can be viewed by passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 April 2021
Resolution: Attending Marine Inspector verified satisfactory repair.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 19 March 2019
Resolved
Vessel did not have a garbage plan.
Action required: 10 - Deficiency Rectified
Resolved 19 March 2019
Resolution: Brought onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 March 2019
Resolved
Didn't have original COD onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: MI satisfaction.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 March 2019
Resolved
Vessel did not have passenger count book.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 March 2019
Resolved
Post safety orientation, stability letter, EAP.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 March 2019
Resolved
Post life jacket placard in main cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 19 March 2019
Resolved
Post MARPOL placards.
Action required: 10 - Deficiency Rectified
Resolved 19 March 2019
Resolution: MI satisfaction.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 March 2019
Resolved
Vessel did not have DAPI crew list.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019
Resolved
Label breakers and post placard for aft. electrical panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2019
Resolved
Label upper deck PFD storage.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2019
Resolved
Label under-seat PFD storage on every row in main cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 March 2019
Resolved
40B:C portable fire fighting extinguishers required in both engine rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: MI satisfaction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019
Resolved
Install bow gate securing arrangement.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019
Resolved
Replace broken light mount in starboard midship void.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: MI satisfaction.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 April 2017
Resolved
Repair/replace damages STBD MDE raw water hose.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 6 April 2017
Resolution: Hose has been replaced.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 April 2017
Resolved
Remove excess water and oil from both engine rooms.
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 6 April 2017
Resolution: Bilges have been cleaned out.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 6 March 2017
Resolved
Prove proper operation of generator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2017
Resolution: Exhaust piping was replaced and generator tested to the satisfaction of Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 March 2017
Resolved
Replace used portable fire extinguishers to comply with amount and type listed on COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2017
Resolution: Fire extinguishers were replaced and stowed in proper location.
Electrical › Electric Generation Source (service) › Generator
Issued 6 March 2017
Resolved
Air intake casing has 4-6" crack and needs repair or replacement.
Due 21 March 2017
Resolved 21 March 2017
Resolution: Casing was replaced and generator tested on load to satisfaction of Marine Inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 June 2016
Resolved
KK02: Repair damaged fuel cut out valves on stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2016
Resolution: Replaced stbd fuel shut off pull to satisfaction of attending CG inspectors.
Stability › Weathertight Integrity › General
Issued 14 June 2016
Resolved
KK01: Repair cracked welds on port forepeak tank.
Due 28 June 2016
Resolved 28 June 2016
Resolution: Received and accepted pictures of new port forepeak tank welds from vessel rep.
Engineering › Fuel Oil Service System › Filter
Issued 7 March 2016
Resolved
Received report vessel lost propulsion on the port engine while underway with passengers. Crew found the aft racor (primary filter) was air bound. Fuel system was primed and engine restarted. Observed underway operational test, port engine max RPM is 2150, at approx. 1875 RPM's port engine starts hunting. Troubleshoot engine, perform underway operational test, submit cause and repair to OCMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2016
Resolved 10 March 2016
Resolution: Port engine aft primary fuel filter was renewed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 March 2016
Resolved
Port engine room has excessive oil in the bilge, remove oil and clean.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2016
Resolved 10 March 2016