Records from 2004 to 2025. Most recent: inspection, 13 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 26
13 November 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8262439
21 May 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8140405
6 November 2024
Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8026847
16 October 2024
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8020716
3 July 2024
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7948588
2 January 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7844292
5 December 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7834146
11 May 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685952
26 April 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676246
1 February 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7602488
9 June 2022
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7472814
8 December 2021
Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7364435
21 October 2021
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7336827
21 January 2021
Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7128063
23 September 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7084252
3 February 2020
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6901503
24 December 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6879217
12 November 2019
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6854245
21 October 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6838461
3 December 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6591029
6 February 2018
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350918
16 November 2017
Hull Examination · Deficiency Check · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339602
26 October 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6295320
8 February 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6084534
7 December 2016
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6054158
6 August 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6035403
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 November 2025
No resolution recorded
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter. (1) No later than the month and year on its servicing sticker affixed under 46 CFR 160.151-57(n). Vessel IBA was found to be out of service due to a lack of servicing as per the recommended schedule. As a result, the vessel's route has been restricted to no more than 1 mile from shore until a currently-serviced liferaft is on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles on board are not made of noncombustible materials.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 26 November 2025
Resolution: Metal trash cans were placed in the boat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections of fire extinguishers not completed and logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 26 November 2025
Resolution: The fire extinguishers and CO2 systems were checked, signed and dated
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 November 2025
Resolved
The master of the vessel shall ensure that the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Did not produce records for EPIRB monthly test.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 26 November 2025
Resolution: The EPIRB was tested and logged
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 November 2025
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Fire fighting drills and training shall be logged or otherwise documented for review by the CG upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Missing description and training topics of drills.
46 CFR 185.520(f)(1)-(2)
46 CFR 185.524(d)(1)-(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 26 November 2025
Resolution: Drills were recorded with all information
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2024
Resolved
Each generator and motor must be: In a location that is accessible, adequately ventilated, and as dry as practicable. MI identified port and STBD generators coated with oil and identified oil-soaked sorbents located underneath the generators. Clean within 7 days.
46 CFR 183.320
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 November 2024
Resolution: Attended vessel and verified port and stbd generators cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2024
Resolved
...Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. MI identified missing visual indicator at the operating station on the electric submersible pumps.
46 CFR 182.520
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 November 2024
Resolution: Vessel will be operating those pumps in manual mode by turning them off at the breaker panel.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 6 November 2024
Resolved
...Have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull. MI identified the longitudinal stiffener was not replaced at the time of a crop and renewal repair. Replace stiffener prior to credit drydock.
46 CFR 176.802(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: Stiffener replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2024
Resolved
...Have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. The Swim platform/ jet protector had a cracked weld. Fix prior to credit drydock.
46 CFR 176.802(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 May 2025
Resolution: Cracked weld repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 July 2024
Resolved
Repairs or alterations to the hull or vessel systems that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Vessel rep reported hull damage, reported to be minimal at initial assessment, above the waterline, due to contact with another vessel while underway in service. Prior to carriage of passengers, provide thorough damage assessment and repair plan proposal to OCMI for review. Upon plan approval, complete any needed repairs to satisfaction of MI's.
46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 May 2023
Resolved
A vessel certificated to operate on a rivers route within one mile of land is not required to carry survival craft.
Vessel has sent IBAs out for servicing. While IBAs are out for service vessel route is limited to rivers, less than 1 mile from shore.
46 CFR 180.208 (c)
Action required: 705 - Other - as specified
Resolved 2 January 2024
Resolution: Sector New York received certificate indicating that IBA has been serviced as required and put back into service on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2023
Resolved
Exhaust piping must be properly supported by non-combustible hangars or blocks. Brackets for exhaust piping in the port engine room were found to be missing securing hardware.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 15 February 2023
Resolution: Satisfactory repairs to support exhaust piping.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 February 2023
Resolved
Cable for power circuits must be UL listed marine cable, meet the applicable criteria of NFPA 70 or 46 CFR sub chapter J. Cable connected to electric heater was not of of an approved type for installation on the vessel.
46 CFR 183.340 (d)-disregard cite below. Correct cite would not populate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 15 February 2023
Resolution: Evidence was provided showing that marine cable was installed in place of non-compliant wiring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 December 2021
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Port/Stbd fore peak could not be draining with bilge system.
46CFR182.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2021
Resolution: Vessels bilge system verified to be fully functional
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 December 2021
Resolved
Flexible hosing designed for use with hose clamps may be installed with two clamps at both ends. Engine cooling supply lines did not have double band clamps on multiple supply hoses. Stbd side. 46CFR182.720(e)(3)(v)(B)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Verified installation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2021
Resolved
Flexible hosing designed for use with hose clamps may be installed with two clamps at both ends. Fuel tank supply line was not double clamped on both ends, stbd side. 46CFR182.720(e)(3)(v)(B)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Verified installation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2021
Resolved
All electrical equipment and circuits bust be clearly marked and identified. CB panel in concessions area needs marking on exterior cabinet identifying the CB panel in it. 46CFR183.220(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Verified installation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2021
Resolved
All electrical equipment and circuits bust be clearly marked and identified. Generator CB in stbd fuel tank space requires labeling. 46CFR183.220(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Verified installation
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 December 2021
Resolved
Portable fire extinguishers require Monthly inspections in accordance with NFPA 10. One fire extinguisher had no inspection since July, all others were only inspected once.46CFR176.810(b)(1)(ii)
Action required: 10 - Deficiency Rectified
Resolved 8 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 February 2020
Resolved
The master of the vessel shall ensure that: The EPIRB's battery is replaced before the date required by FCC regulations. EPIRB’s battery is expired. Service EPIRB and provide report.
46 CFR 185.728 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2020
Resolved 18 February 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 February 2020
Resolved
The VSL must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76. Means to manually acknowledge all alarm and fault signals must be provided at the control panel. The alarm fire panel buttons kept getting stuck and were not operating properly. Replace or perform maintenance on buttons to keep them operational.
46 CFR 181.405 (a)
46 CFR 76.27.10 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2020
Resolved 18 February 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 February 2020
Resolved
Rail courses or the equivalent must be installed between a top rail, and the deck so that no open space exists that is more than 305 millimeters (12 inches). Post quarter bottom deck chain attachment point broken. Weld eye and re-attach chain
46 CFR 177.900 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2020
Resolved 18 February 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 December 2019
Resolved
A subchapter K applicable vessel may not operate without a valid COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 December 2019
Resolved
Outdrive bucket rachet strapped in upward position to mooring cleat on main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 December 2019
Resolved
Missing rails or safety equivalent on stern
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 November 2019
Resolved
THE MASTER SHALL ENSURE THAT SUFFICIENT FIRE AND ABANDON SHIP DRILLS ARE CONDUCTED TO MAKE SURE EACH CREW MEMBER IS FAMILIAR WITH THEIR DUTIES DURING AN EMERGENCY. THE CREW THAT WILL BE OPERATING THE VESSEL SHALL CONDUCT FIRE AND ABOANDON SHIP DRILLS PRIOR TO CARRYING PASSENGERS.
Cite: 45CFR185.524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 November 2019
Resolved
THE MASTER SHALL ENSURE THAT SUFFICIENT FIRE AND ABANDON SHIP DRILLS ARE CONDUCTED TO MAKE SURE EACH CREW MEMBER IS FAMILIAR WITH THEIR DUTIES DURING AN EMERGENCY. THE CREW THAT WILL BE OPERATING THE VESSEL SHALL CONDUCT FIRE AND ABOANDON SHIP DRILLS PRIOR TO CARRYING PASSENGERS.
Cite: 46CFR185.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 November 2019
Resolved
EACH RING LIFE BUOY SHALL BE OF THE TYPE APPROVED BY 46CFR160.050. ONE RING LIFE BUOY SHALL HAVE A LIFELINE 0F AT LEAST 60-FEET, 5/16-INCH THICKNESS, NON-KINKING, BE OF DARK COLOR OR RESISTENT TO DETERIORATION (IF SYNTHETIC), AND HAVE A BREAKING STRENTH OF 1124-LBS. ALL OF THE RING LIFE BUOYS HAD GRAB LINES THAT WERE DETERIORATING; THE LIFE-LINE AND LINE FOR THE FLOATING WATER LIGHT WERE ALSO SUN BLEACHED AND DETERIORATED.
Cite: 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 12 November 2019
Resolved
OPENINGS IN THE HULL OF A VESSEL SHALL BE MADE TO PREVENT THE ENGRESS OF WATER IF A PIPE FRACTURES. THE BAR AREA SINK DRAIN PIPE WAS DETERIORATED AND BROKEN, CREATING AN AVENUE FOR WATER TO ENTER THE WATERTIGHT ENVELOPE OF THE VESSEL.
Cite: 46CFR179.350
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2019
Resolution: The hull penetration was plugged, utilizing a pipe cap to prevent water engress.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 November 2019
Resolved
THE VESSELS HULL SHALL MAINTAIN WATERTIGHT INTEGRITY. THERE WAS AN APPROXIMATELY 6-INCH LONG CRACK DISCOVERED ON THE PORT SIDE AFT DECK (LAZARRETTE SPACE) CONTINUED THROUGH THE HATCH COAMING. HATCH MECHANISM INOP.
Cite: 46CFR176.802
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2019
Resolution: The crack was repaired utilizing a drill stop, vee out, and reweld method. MI verified procedures used and visually inspected weld.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 November 2019
Resolved
VESSEL SHALL HAVE DECK RAILS WITH RAIL COURSES OF NO GREATER THAN 12-INCHES AND CAPABLE OF SUPPORTING 200-LBS. OF FORCE. THE PORT, AFT RAIL, BOTTOM COURSE HAS A BROKEN WELD, RENDERRING THE COURSE NOT CAPABLE OF WITHSTANDING 200-LBS OF FORCE AND THE PORT AFT LADDER HAS SEPARATED IN THE SUPPORT RUN.
Cite: 46CFR177.900
Specification: No passengers on port side aft deck.
Action required: 705 - Other - as specified
Resolved 13 November 2019
Resolution: Repairs made by re-welding the bottom rail at the connection point and by veeing out and re-weldin g the separated section of the ladderway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 November 2019
Resolved
THE VESSEL SHALL BE KEPT IN A CONDITION FREE OF HAZARDOUS AND UNSAFE CONDITIONS. THERE WAS AN ACCUMULATION OF OIL UNDER THE PORT GENERATOR.
Cite: 46CFR176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2019
Resolution: Mi verified that the oil had been cleaned up at the time of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2019
Resolved
PROPULSION MACHINERY SHALL BE CAPABLE OF HANDLING A CONSTANT MARINE LOAD. THE #3 MAIN JET ENGINE'S REVERSE CYLINDER SEAL WAS LEAKING WATER FROM OUTSIDE, INTO THE LAZARRETTE. ADDITIONALLY, THE #4 MAIN ENGINE WAS ALARMING TO THE POINT THAT THE ENGINEER SHUT IT DOWN.
46CFR182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2019
Resolution: Engineer replaced the seal and changed out a breaker, eliminating the water leak and stopping the alarming of the system.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 November 2019
Resolved
VESSELS SHALL HAVE NAV. CHARTS AND PUBLICATIONS AS PER THIS PART. THE VESSEL DID NBOT HAVE NAV. CHARTS AND THE PUBLICATIONS WERE OUTDATED.
46CFR184.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2019
Resolution: Vessel had current charts and publications on board at the time of def check. Pubs were printed versions that were placed into the ships binder.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 November 2019
Resolved
INSTALLATIONS OF EQUIPMENT SHALL BE OF AN APPROVED TYPE. THE VESSEL HAD AN "AMAZON BASICS" POWER STRIP PLUGGED IN, IN A CABINET ON THE BRIDGE. POWER STRIP IS NOT OF AN APPROVED MARINE TYPE.
46CFR175.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2019
Resolution: The power strip was removed from the vessel and the equipment that was plugged into it was plugged into the hardwired outlet in the cabinet.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 November 2019
Resolved
VESSEL HULL SHALL BE MAINTAINED IN THE CONDITION APPROVED. VESSEL HAD A CRACKED WELD IN THE STARBOARD BOW RUB RAIL.
46CFR176.802
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 November 2019
Resolution: Weld repairs were made on rub rail.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 12 November 2019
Resolved
A VESSEL CARRYING 49+ PASSENGERS SHALL BE EQUIPPED WITH AN FCC APPROVED MARINE RADAR. THE RADAR ONBOARD THE VESSEL WAS INOPERABLE.
46CFR184.404
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2019
Resolution: Witnessed on board radar operating
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 November 2019
Resolved
A FIXED-FIRE EXTINGUISHING SYSTEM SHALL BE MAINTAINED IN ACCORDANCE WITH NFPA 10. THE ALARM HORNS FOR THE CO2 SYSTEM IN BOTH ENGINE ROOMS WERE DETERIORATED. SYSTEM WAS SERVICED IN SEP. 2019.
46CFR176.810(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 27 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 November 2019
Resolved
VESSELS SHALL BE MAINTAINED IN GOOD MARINE CONDITION. SEVERAL LIGHTBULBS IN THE VOID SPACES AND ENGINE ROOMS WERE EXTINGUISHED.
46CFR176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 13 November 2019
Resolution: MI verified light bulbs had been replaced at the time of inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 November 2019
Resolved
VESSELS OF AT LEAST 5 NET TONS, ENGAGING IN COASTWISE TRADE SHALL HAVE A CERTIFICATE OF DOCUMENTATION
(C.O.D.). THE VESSELS C.O.D. WAS EXPIRED AND A NEW ONE HAD NOT BEEN APPLIED FOR. 46CFR67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 10 December 2019
Resolution: Vessel has valid COD
Construction/Loadline › Hull › Hull Plating
Issued 6 February 2018
Resolved
Vessel has a small leak below the water line in the STBD aft engine room behind the entrance ladder. Vessel may not carry passengers or move from the current home port area until a CGMI attends the vessel and this office receives a repair plan and gives permission to proceed to a repair facility.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2018
Resolution: Vessel completed repairs to hull plating during an emergency dry dock. All repairs witnessed by MI.
Electrical › Electric Generation Source (service) › Generator
Issued 26 October 2017
Resolved
Prove operation of port generator in the presence of CG marine inspector.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 9 November 2017
Resolution: Confirmed proper operation of port (No. 1) generator.
Lifesaving › Hand Flares › Quantity
Issued 26 October 2017
Resolved
Provide (03) hand red flares and (03) hand orange flares IAW 46 CFR 180.68. Restricted to LBS route.
Action required: 705 - Other - as specified
Resolved 9 November 2017
Resolution: Confirmed twelve (12) unexpired hand flares for Limited Coastwise route.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 December 2016
Resolved
A device must be provided to automatically shut down engines that draw intake air from the protected space prior to the release of the extinguishing agent into the space. Install a pressure switch that will automatically shut down the main engines prior to the release of the CO2.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 9 January 2017
Resolution: The operator appealed the deficiency and the appeal was granted.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 7 December 2016
Resolved
Install an approved fixed fire extinguishing system in the space that contains the oil fired heater.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 9 January 2017
Resolution: Complete
Engineering › Steering Gear System › Actuator
Issued 7 December 2016
Resolved
Replace oil pressure sensor on the #1 jet drive.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Resolution: Complete
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 7 December 2016
Resolved
Renew certificate. Vessel is restricted to 1000 yards from shore.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 9 December 2016
Resolution: Received updated copy of the certificate.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 December 2016
Resolved
Renew Certificate. Vessel is restricted to 1000 yards from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 9 December 2016
Resolution: Recieved updated copy of the certificate.